  • Wide input, 3.0-5.5 Vdc
  • Programmable output, 0.75 - 3.6 Vdc
  • Under voltage protection
  • Short circuit protection
  • Remote sense
  • Remote On/Off
  • Design for Environment (DfE)
  • European Commission Directive 2002/95/EC (RoHs) compliant E Datasheet DC/DC regulator Input 3.0 - 5.5 V Output 16 A PMB 4518T WP The PMB series of SIL DC/DC regulators (POL) are intended to be used as local distributed power sources in distributed power architec- ture level 4. The single in-line design makes the PMB series suitable for applications where boardspace is limited. The high efficiency and high reliability of the PMB series makes them particularly suited for the communications equipment of today and tomorrow. These products are manufactured using the most advanced technologies and materials to com- ply with environmental requirements. Designed to meet high reliability requirements of systems manufacturers, the PMB responds to world-class specifications. Ericsson Power Modules is an ISO 9001/14001 certified supplier.

Contents

Compatibility with RoHS requirements . . . .28 Sales Offices and Contact Information . . . .29

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet 8,80 [0.346] 7,40 [0.291] 51,80 [2.039] 48,26 [1.900] Recommended footprint (customer board), no components within border. Holes: Ø1,0 [0.04] through plated holes with Ø1,5 [0.06] pads on both sides. Note 1: For other pin lengths, refer to Product program/Ordering information 1 2 3 4 5 6 7 8 9 10 Dimensions in mm [inch] Tolerances (unless specified): x,x +/-0,5 [0.02] E 7,0 [0.27] 8,5 [0.33] max choke 35,56 [1.400] 48,26 [1.900] 13,20 [0.520] 50,8 [2.00] pin length 3,60 [0.142] (Note 1) Mechanical Data Product Program Delivery option M.o.q. Suffix Example Tray 100 pcs /B PMB 4xxxT WP /B

Ordering Information

PO max Ordering No. Comment Output 1 3.0-5.5 V 1.0 V/16 A 16.0 W PMB 4118NA WP On request 3.0-5.5 V 1.2 V/16 A 19.2 W PMB 4118LA WP On request 3.0-5.5 V 1.5 V/16 A 24.0 W PMB 4218H WP On request 3.0-5.5 V 1.8 V/16 A 28.8 W PMB 4218G WP On request 3.0-5.5 V 2.5 V/16 A 40.0 W PMB 4419 WP On request 3.8-5.5 V 3.3 V/16 A 52.8 W PMB 4510 WP On request Option Suffix Example Positive Remote Control logic P PMB 4518T WPP

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Characteristics min typ max Unit Tref Operating Reference Temperature, see pg. 27 -45 +115 ˚C TS Storage temperature -55 +125 ˚C VI Input voltage -0.3 +5.5 Vdc Characteristics Conditions min typ max Unit VI Input voltage range 3.0 5.5 Vdc VIoff Turn-off input voltage Ramp from higher voltage, Vout = 1.0- 2.5 V, Vin = 3.3 V 2.2 Vdc Ramp from higher voltage, Vout = 3.3 V, Vin = 5.0 V 3.4 VIon Turn-on input voltage Ramp from lower voltage, Vout = 1.0- 2.5 V, Vin = 3.3 V 2.7 Vdc Ramp from lower voltage, Vout = 3.3 V, Vin = 5.0 V 3.5 CI Input capacitance 20 µF PIi Input idling power Io = 0 A, VI = 5 V 680 mW PRC Input stand-by power (RC active) Non operation, VI = 5 V 7.5 mW VIac Input ripple 1) 20 Hz ... 5 MHz, Iomax, VI = 5 V 400 mV Input Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified manner. Absolute Maximum Ratings Typ values specified at: Tref = +25 ˚C, VInom, Iomax = 16 A 1) Measured with 2 x 22 µF ceramic capacitors Connections Weight 7.7g Pin Designation Function 1 + Out Positive output 2 + Out Positive output 3 + Sense Positive sense 4 + Out Positive output

5 GND Ground

6 GND Ground

9 Vadj Output voltage adjust

10 RC Remote control

Material: Copper alloy Plating: Matte tin over nickel

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Characteristics Random Vibration IEC 60068-2-64 Frequency Acceleration density 5 ... 500 Hz 0.5 g2/Hz Mechanical shock (half sinus) IEC 60068-2-27 Peak acceleration Duration 50 g 11 ms Lead integrity IEC 60068-2-21 Ub Simultaneous bending All leads Temperature cycling JESD22-A104-BG Temperature Number of cycles -40 ... +125 ˚C 300 Accelerated damp heat JESD22-A101-B Temperature Humidity Duration Bias +85 ˚C 85 % RH 1000 hours max input voltage Solderability IEC 60068-2-54 (Aged according to JESD22-A101- B, 240h no bias) Solder immersion depth Time for onset of wetting Wetting force 2 mm < 2.5 s > 200 mN/m Cold (in operation) IEC 60068-2-1 Temperature Duration -45 ˚C 72 h High temperature storage JESD22-A103-BA Temperature Duration +125 ˚C 1000 h Product Qualification Specification Fundamental Circuit Diagram GNDGND PWM +IN +OUT +SENSE Vadj controller Ref GND Error amplifier RC RC GND Block

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Ericsson Power Modules DC/DC converters and DC/DC regulators are designed in accordance with safety standards IEC/EN/UL 60 950, Safety of Information Technology Equipment. IEC/EN/UL60950 contains requirements to prevent injury or damage due to the following hazards:

  • Electrical shock
  • Energy hazards
  • Fire
  • Mechanical and heat hazards
  • Radiation hazards
  • Chemical hazards On-board DC-DC converters are defined as component power supplies. As components they cannot fully comply with the provisions of any Safety requirements without “Conditions of Acceptability”. It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable Safety standards and Directives for the final product. Component power supplies for general use should comply with the requirements in IEC60950, EN60950 and UL60950 “Safety of information technology equipment”. There are other more product related standards, e.g. IEC61204-7 “Safety standard for power supplies", IEEE802.3af “Ethernet LAN/MAN Data terminal equipment power”, and ETS300132-2 “Power supply interface at the input to telecommunications equipment; part 2: DC”, but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL 60 950 recognized and certified in accordance with EN 60 950. The flammability rating for all construction parts of the products meets UL 94V-0. The products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. Normally the output of the DC/DC converter is considered as SELV (Safety Extra Low Voltage) and the input source must be isolated by minimum Double or Reinforced Insulation from the primary circuit (AC mains) in accordance with IEC/EN/UL 60 950. Safety Specification Isolated DC/DC converters. The input voltage to the DC/DC regulator is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. It is recommended that a slow blow fuse with a rating twice the maximum input current per selected product be used at the input of each DC/DC regulator. Non-isolated DC/DC regulators. 24 V dc systems. The input voltage to the DC/DC converter is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and 60 V dc systems. If the input voltage to Ericsson Power Modules DC/DC converter is 75 V dc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. Single fault testing in the input power supply circuit should be performed with the DC/DC converter connected to demonstrate that the input voltage does not exceed 75 V dc. If the input power source circuit is a DC power system, the source may be treated as a TNV2 circuit and testing has demonstrated compliance with SELV limits and isolation requirements equivalent to Basic Insulation in accordance with IEC/EN/UL 60 950. It is recommended that a fast blow fuse with a rating twice the maximum input current per selected product be used at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem in the input filter or in the DC/DC converter that imposes a short circuit on the input source, this fuse will provide the following functions:
  • Isolate the faulty DC/DC converter from the input power source so as not to affect the operation of other parts of the system.
  • Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. The galvanic isolation is verified in an electric strength test. The test voltage (VISO) between input and output is 1500 Vdc or 2250 Vdc for 60 seconds (refer to product specification). Leakage current is less than 1µA at nominal input voltage. General information.

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Characteristics Conditions Output Unit min typ max VOi Output voltage adjusted setting Tref = +25 °C, VInom, IOmax, Radj 80 kΩ 0.98 1.00 1.02 V VO Idling voltage IO = 0 0.98 1.02 V Line regulation VImin ... VImax, IOmax 11 mV Vtr Load transient dI/dt = 5 A/µs, CO = 150 µF , VI = 3.3 V 100 mV ttr Load transient recovery time 60 µs ts Start-up time From VI connected to VO = 0.9 x VOI, tr Fall time, VO x 0.1 IO = IOmax, VInom 0.2 ms tr Fall time, VO x 0.1 IO = 0 A, VInom 5 s tRCoff RC shut-down time to VO x 0.1 IO = IOmax, VInom 0.2 ms tRCon RC start-up time to VO x 0.9 IO = IOmax, VInom 8 ms IO Output current 0 16 A POmax Max output power At VO = VOnom 16 W Ilim Current limit threshold Tref < Trefmax 22 28 35 A VOac Output ripple 20 Hz ... 5 MHz, IOmax 10 20 mVp-p η Efficiency - 50% load IO = 0.5 x IOmax, VI = 5 V 87.2 % η Efficiency - 100% load IO = IOmax, VI = 5 V 81 83.4 % Pd Power Dissipation IO = IOmax, VI = 5 V 3.1 3.8 W Fo Switching frequency IO = 0 ... 1.0 x IOmax 250 300 350 kHz Isense Remote sense current 8 mA II Static input current VI = 3.0 V, IO = IOmax, Tref = 25 °C 6.7 A MTBF Predicted reliability Tref = 40 °C 6 million hours Typ values specified at: Tref = +25 °C and VInom. IOmax = 16 A. Note: +Sense connected to +Out Adjusted to 1.0 V out - Data

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Output Current Derating at V input Start-Up Output voltage vs. load current. Available load current vs. ambient air temperature and airflow at Vin = 5 V. See conditions on page 27. Start-up at IO = 16 A resistive load at Tref = +25 °C, Vin = 3.3 V. Start enabled by connecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Efficiency Power Dissipation Output Characteristics Adjusted to 1.0 V out - Typical Characteristics Efficiency vs. load current and input voltage at Tref = +25 °C <"> <"> <7> <"> <8> Dissipated power vs. load current and input voltage at Tref = +25 °C General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF Output Current Derating at . V input Available load current vs. ambient air temperature and airflow at Vin = 3.3 V. See conditions on page 27. <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Turn Off Output Ripple Transient with 10 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Transient with 00 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Output voltage ripple (20mV/div.) at Tref=+25 °C, Vin=3.3 V, IO=16 A resistive load. Band width=5MHz. Time scale: 2µs / div. Turn-off at IO=16 A resistive load at Tref=+25 °C, Vin=3.3 V. Turn-off enabled by disconnecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Adjusted to 1.0 V out - Typical Characteristics General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Typ values specified at: Tref = +25 °C and VInom, IOmax = 16 A. Note: +Sense connected to +Out Adjusted to 1. V out - Data Characteristics Conditions Output Unit min typ max VOi Output voltage adjusted setting Tref = +25 °C, VInom, IOmax, Radj 42 kΩ 1.176 1.20 1.224 V VO Idling voltage IO = 0 1.18 1.22 V Line regulation VImin ... VImax, IOmax 11 mV Vtr Load transient dI/dt = 5 A/µs, CO = 150 µF , VI = 3.3 V 120 mV ttr Load transient recovery time 60 µs ts Start-up time From VI connected to VO = 0.9 x VOI, tr Fall time, VO x 0.1 IO = IOmax, VInom 0.2 ms tr Fall time, VO x 0.1 IO = 0 A, VInom 5 s tRCoff RC shut-down time to VO x 0.1 IO = IOmax, VInom 0.2 ms tRCon RC start-up time to VO x 0.9 IO = IOmax, VInom 8 ms IO Output current 0 16 A POmax Max output power At VO = VOnom 19.2 W Ilim Current limit threshold Tref < Trefmax 22 28 35 A VOac Output ripple 20 Hz ... 5 MHz, IOmax 10 20 mVp-p η Efficiency - 50% load IO = 0.5 x IOmax, VI = 5 V 89 % η Efficiency - 100% load IO = IOmax, VI = 5 V 82.7 85.1 % Pd Power Dissipation IO = IOmax, VI = 5 V 3.3 4.0 W Fo Switching frequency IO = 0 ... 1.0 x IOmax 260 300 340 kHz Isense Remote sense current 8 mA II Static input current VI = 3.0 V, IO = IOmax, Tref = 25 °C 7.8 A MTBF Predicted reliability Tref = 40 °C 6 million hours

10 EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet

Output Current Derating at V input Output Characteristic Start-Up Output voltage vs. load current. Available load current vs. ambient air temperature and airflow at Vin = 5 V. See conditions on page 27. Start-up at IO = 16 A resistive load at Tref = +25 °C, Vin = 3.3 V. Start enabled by connecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Efficiency Power Dissipation Adjusted to 1. V - Typical Characteristics Efficiency vs. load current and input voltage at Tre = +25 °C <"> <"> <7> <"> <8> Dissipated power vs. load current and input voltage at Tref = +25 °C General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF Output Current Derating at . V input Available load current vs. ambient air temperature and airflow at Vin = 3.3 V. See conditions on page 27. <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN

11 EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet

Transient with 10 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Transient with 00 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Output voltage ripple (20mV/div.) at Tref=+25 °C, Vin=3.3 V, IO=16 A resistive load. Band width=5MHz. Time scale: 2µs / div. Turn-off at IO=16 A resistive load at Tref=+25 °C, Vin=3.3 V. Turn-off enabled by disconnecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Adjusted to 1. V - Typical Characteristics General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF

1 EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet

Characteristics Conditions Output Unit min typ max VOi Output voltage adjusted setting Tref = +25 °C, VInom, IOmax, Radj 23 kΩ 1.47 1.5 1.53 V VO Idling voltage IO = 0 1.48 1.52 V Line regulation VImin ... VImax, IOmax 11 mV Vtr Load transient dI/dt = 5 A/µs, CO = 150 µF , VI = 3.3 V 120 mV ttr Load transient recovery time 60 µs ts Start-up time From VI connected to VO = 0.9 x VOI, tr Fall time, VO x 0.1 IO = IOmax, VInom 0.2 ms tr Fall time, VO x 0.1 IO = 0 A, VInom 5 s tRCoff RC shut-down time to VO x 0.1 IO = IOmax, VInom 0.2 ms tRCon RC start-up time to VO x 0.9 IO = IOmax, VInom 8 ms IO Output current 0 16 A POmax Max output power At VO = VOnom 24 W Ilim Current limit threshold Tref < Trefmax 22 28 35 A VOac Output ripple 20Hz ... 5MHz, IOmax 10 20 mVp-p η Efficiency - 50% load IO = 0.5 x IOmax, VI = 5 V 91 % η Efficiency - 100% load IO = IOmax, VI = 5 V 85.5 87.7 % Pd Power Dissipation IO = IOmax, VI = 5 V 3.2 4.1 W Fo Switching frequency IO = 0 ... 1.0 x IOmax 260 300 340 kHz Isense Remote sense current 8 mA II Static input current VI = 3.0 V, IO = IOmax, Tref = 25 °C 9.5 A MTBF Predicted reliability Tref = 40 °C 6 million hours Typ values specified at: Tref = +25 °C and VInom. IOmax = 16 A. Note: +Sense connected to +Out Adjusted to 1. V out - Data

Output Current Derating at V input Output Characteristic Start-Up Output voltage vs. load current. Available load current vs. ambient air temperature and airflow at Vin = 5 V. See conditions on page 27. <"> <7> Start-up at IO = 16 A resistive load at Tref = +25 °C, Vin = 3.3 V. Start enabled by connecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Efficiency Power Dissipation Adjusted to 1.V out - Typical Characteristics Efficiency vs. load current and input voltage at Tref = +25 °C <"> <"> <8> Dissipated power vs. load current and input voltage at Tref = +25 °C General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF Output Current Derating at . V input Available load current vs. ambient air temperature and airflow at Vin = 3.3 V. See conditions on page 27. <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN

Transient with 10 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Transient with 00 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Output voltage ripple (20mV/div.) at Tref=+25 °C, Vin=3.3 V, IO=16 A resistive load. Band width=5MHz. Time scale: 2µs / div. Turn-off at IO=16 A resistive load at Tref=+25 °C, Vin=3.3 V. Turn-off enabled by disconnecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Adjusted to 1.V out - Typical Characteristics General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF

Typ values specified at: Tref = +25 °C and VInom. IOmax = 16 A. Note: +Sense connected to +Out Adjusted to 1. V out - Data Characteristics Conditions Output Unit min typ max VOi Output voltage adjusted setting Tref = +25 °C, VInom, IOmax, Radj 15 kΩ 1.764 1.80 1.836 V VO Idling voltage IO = 0 1.78 1.82 V Line regulation VImin ... VImax, IOmax 11 mV Vtr Load transient dI/dt = 5 A/µs, CO = 150 µF , VI = 3.3 V 110 mV ttr Load transient recovery time 60 µs ts Start-up time From VI connected to VO = 0.9 x VOI, tr Fall time, VO x 0.1 IO = IOmax, VInom 0.2 ms tr Fall time, VO x 0.1 IO = 0 A, VInom 5 s tRCoff RC shut-down time to VO x 0.1 IO = IOmax, VInom 0.2 ms tRCon RC start-up time to VO x 0.9 IO = IOmax, VInom 8 ms IO Output current 0 16 A POmax Max output power At VO = VOnom 28.8 W Ilim Current limit threshold Tref < Trefmax 22 28 35 A VOac Output ripple 20 Hz ... 5 MHz, IOmax 14 24 mVp-p η Efficiency - 50% load IO = 0.5 x IOmax, VI = 5 V 92 % η Efficiency - 100% load IO = IOmax, VI = 5 V 88.5 89.8 % Pd Power Dissipation IO = IOmax, VI = 5 V 3.3 3.8 W Fo Switching frequency IO = 0 ... 1.0 x IOmax 260 300 340 kHz Isense Remote sense current 8 mA II Static input current VI = 3.0 V, IO = IOmax, Tref = 25 °C 10.9 A MTBF Predicted reliability Tref = 40 °C 6 million hours

Output Current Derating at . V input Output Current Derating at V input Adjusted to 1. V - Typical Characteristics Output Characteristic Start-Up Output voltage vs. load current. Available load current vs. ambient air temperature and airflow at Vin = 5 V. See conditions on page 27. Efficiency vs. load current and input voltage at Tref = +25 °C <"> <"> <7> Start-up at IO = 16 A resistive load at Tref = +25 °C, Vin = 3.3 V. Start enabled by connecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Available load current vs. ambient air temperature and airflow at Vin = 3.3 V. See conditions on page 27. Power Dissipation <"> <8> Dissipated power vs. load current and input voltage at Tref=+25 °C <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN

Adjusted to 1. V out - Typical Characteristics Transient with 10 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Transient with 00 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Output voltage ripple (20mV/div.) at Tref=+25 °C, Vin=3.3 V, IO=16 A resistive load. Band width=5MHz. Time scale: 2µs / div. Turn-off at IO=16 A resistive load at Tref=+25 °C, Vin=3.3 V. Turn-off enabled by disconnecting Vin. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF

Characteristics Conditions Output Unit min typ max VOi Output voltage adjusted setting Tref = +25 °C, VInom, IOmax, Radj 7 kΩ 2.45 2.5 2.55 V VO Idling voltage IO = 0 2.48 2.52 V Line regulation VImin ... VImax, IOmax 11 mV Vtr Load transient dI/dt = 5 A/µs, CO = 150 µF , VI = 3.3 V 160 mV ttr Load transient recovery time 60 µs ts Start-up time From VI connected to VO = 0.9 x VOI, tr Fall time, VO x 0.1 IO = IOmax, VInom 0.2 ms tr Fall time, VO x 0.1 IO = 0 A, VInom 5 s tRCoff RC shut-down time to VO x 0.1 IO = IOmax, VInom 0.2 ms tRCon RC start-up time to VO x 0.9 IO = IOmax, VInom 8 ms IO Output current 0 16 A POmax Max output power At VO = VOnom 40 W Ilim Current limit threshold Tref < Trefmax 22 28 35 A VOac Output ripple 20 Hz ... 5 MHz, IOmax 20 35 mVp-p η Efficiency - 50% load IO = 0.5 x IOmax, VI = 5 V 94 % η Efficiency - 100% load IO = IOmax, VI = 5 V 90 92 % Pd Power Dissipation IO = IOmax, VI = 5 V 3.4 4.5 W Fo Switching frequency IO = 0 ... 1.0 x IOmax 260 300 340 kHz Isense Remote sense current 8 mA II Static input current VI = 3.0 V, IO = IOmax, Tref = 25 °C 15.1 A MTBF Predicted reliability Tref = 40 °C 6 million hours Typ values specified at: Tref = +25 °C and VInom. IOmax = 16 A. Note: +Sense connected to +Out Adjusted to . V out - Data

Output Current Derating at V input Output Characteristic Start-Up Output voltage vs. load current. Available load current vs. ambient air temperature and airflow at Vin = 5 V. See conditions on page 27. <"> <7> Start-up at IO = 16 A resistive load at Tref = +25 °C, Vin = 3.3 V. Start enabled by connecting Vin. Top trace: output voltage (1 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Efficiency Power Dissipation Adjusted to . V out - Typical Characteristics Efficiency vs. load current and input voltage at Tref = +25 °C <"> <"> <8> Dissipated power vs. load current and input voltage at Tref = +25 °C General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF Output Current Derating at . V input Available load current vs. ambient air temperature and airflow at Vin = 3.3 V. See conditions on page 27. <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN

0 EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet

Transient with 10 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Transient with 00 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 3.3 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Output voltage ripple (20mV/div.) at Tref=+25 °C, Vin=3.3 V, IO=16 A resistive load. Band width=5MHz. Time scale: 2µs / div. Turn-off at IO=16 A resistive load at Tref=+25 °C, Vin=3.3 V. Turn-off enabled by disconnecting Vin. Top trace: output voltage (1 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Adjusted to . V out - Typical Characteristics General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF

Typ values specified at: Tref = +25 °C and VI = 5.0 V. IOmax = 16 A. Note: +Sense connected to +Out Adjusted to . V out - Data Characteristics Conditions Output Unit min typ max VO Idling voltage IO = 0 3.28 3.32 V Line regulation VI = 5 V ... VImax, IOmax 11 mV Vtr Load transient dI/dt = 5 A/µs, CO = 150 µF , VI = 5 V 120 mV ttr Load transient recovery time 60 µs ts Start-up time From VI connected to VO = 0.9 x VOadj, VI = 5 V 4 ms tr Fall time, VO x 0.1 IO = IOmax, VI = 5 V 0.2 ms tr Fall time, VO x 0.1 IO = 0 A, VI = 5 V 5 s tRCoff RC shut-down time to VO x 0.1 IO = IOmax, VI = 5 V 0.2 ms tRCon RC start-up time to VO x 0.9 IO = IOmax, VI = 5 V 8 ms IO Output current 0 16 A POmax Max output power At VO = VOnom 52.8 W Ilim Current limit threshold Tref < Trefmax 22 25 35 A VOac Output ripple 20 Hz ... 5 MHz, IOmax 25 40 mVp-p η Efficiency - 50% load IO = 0.5 x IOmax, VI = 5 V 95.4 % η Efficiency - 100% load IO = IOmax, VI = 5 V 92 94 % Pd Power Dissipation IO = IOmax, VI = 5 V 3.2 4.6 W Fo Switching frequency IO = 0 ... 1.0 x IOmax 260 300 340 kHz Isense Remote sense current 8 mA II Static input current VI = 3.8 V, IO = IOmax, Tref = 25 °C 15.0 A MTBF Predicted reliability Tref = 40 °C 6 million hours

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Output Current Derating at V inputOutput Characteristic Start-Up Output voltage vs. load current. Available load current vs. ambient air temperature and airflow at Vin = 5 V. See conditions on page 27. <"> <7> Start-up at IO = 16 A resistive load at Tref = +25 °C, Vin = 5 V. Start enabled by connecting Vin. Top trace: output voltage (1 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div. Efficiency Power Dissipation Adjusted to . V out - Typical Characteristics Efficiency vs. load current and input voltage at Tref = +25 °C <"> <"> <8> Dissipated power vs. load current and input voltage at Tref = +25 °C General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF <«$> <"> NT MGN NT MGN NT MGN /BU$POW NT MGN NT MGN Turn Off Turn-off at IO=16 A resistive load at Tref=+25 °C, Vin = 5 V. Turn-off enabled by disconnecting Vin. Top trace: output voltage (1 V/div.). Bottom trace: input voltage (2 V/div.). Time scale: 2 ms/div.

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Output Ripple Transient with 10 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref = +25 °C, Vin = 5 V. dI/dt = 5 A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Transient with 00 µF output capacitor Output voltage response to load current step-change (4-12-4 A) at Tref =+25 °C, Vin = 5 V. dI/dt = 5A/µs Top trace: output voltage (ac) (100 mV/div.). Bottom trace: load current (dc) (10 A/div.) Time scale: 0.1 ms/div. Output voltage ripple (20mV/div.) at Tref= +25 °C, Vin = 5 V, IO = 16 A resistive load. Band width = 5 MHz. Time scale: 2 µs / div. Adjusted to . V out - Typical Characteristics General conditions: Input filter 2 x 22 µF , Output filter 1 x 150 µF

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet RC Regulator condition min typ max Unit High level referenced to GND OFF 1.7 5.5 V Open ON EMC Specification Layout Recommendation The radiated EMI performance of the DC/DC regulator will be optimised by including a ground plane in the PCB area under the DC/DC regulator. This approach will return switching noise to ground as directly as possible, with improvements to both emission and susceptibility. Operating Information Remote Control (RC) The RC pin may be used to turn on or turn off the regulator using a suitable open collector function. Turn off is achieved by connecting the RC pin to the input voltage. The regulator will run in normal operation when the RC pin is left open. All PMB 4000 Series DC/DC regulators have a positive re- mote sense pin that can be used to compensate for moder- ate amounts of resistance in the distribution system and al- low for voltage regulation at the load or other selected point. The remote sense line will carry very little current and does not need a large cross sectional area. However, the sense line on the PCB should be located close to a ground trace or ground plane. The remote sense circuitry will compensate for up to 10% voltage drop between the sense voltage and the voltage at the output pins from VOnom. If the remote sense is not needed the sense pin should be left open. Remote Sense 'SFRVFODZ < )[> RC Vi Module Vi GND

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Input And Output Impedance Operating Information Output Voltage Adjust (Vadj) The output voltage can be set by means of an external resistor, connected to the Vadj pin. Nominal output voltage 0.75 V is set by leaving the Vadj pin open. Adjustment can only be made to increase the output voltage setting. To increase: Connect a resistor between (Vadj) and (Gnd). The output voltage increases with decreasing resistor value as shown in the table below. Note that the maximum output voltage 3.63 V may not be exceeded. Rext up (kohm) = (21.007 / (VO - 0.75225)) - 5.1 Circuit configuration for output voltage adjust Increase +Out GND Vadj Load Radj Sense Output Voltage (V) Resistor (ohm)

0.75 Open

1.0 79.691 k 1.2 41.817 k 1.5 22.990 k 1.8 14.949 k 2.5 6.919 k 3.3 3.145 k Current Limit Protection The PMB 4000 Series DC/DC regulators include current limiting circuitry that allows them to withstand continuous overloads or short circuit conditions on the output. The cur- rent limit is of hick-up mode type. The regulator will resume normal operation after removal of the overload. The load distribution system should be designed to carry the maximum output short circuit current specified. Input And Output Impedance The impedance of both the power source and the load will interact with the impedance of the DC/DC regulator. It is most important to have a low characteristic impedance, both at the input and output, as the regulators have a low energy storage capability. Use capacitors across the input if the source inductance is greater than 4.7 µH. Suitable input capacitors are 22 µF - 220 µF low ESR ceramics. Maximum Capacitive Load When powering loads with significant dynamic current requirements, the voltage regulation at the load can be improved by addition of decoupling capacitance at the load. The most effective technique is to locate low ESR ceramic capacitors as close to the load as possible, using several capacitors to lower the total ESR. These ceramic capacitors will handle short duration high-frequency components of dynamic load changes. In addition, higher values of capacitors (electrolytic capacitors) should be used to handle the mid-frequency components. It is equally important to use good design practice when configuring the DC distribution system. Low resistance and low inductance PCB layouts and cabling should be used. Remember that when using remote sensing, all resistance (including the ESR), inductance and capacitance of the distribution system is within the feedback loop of the regulator. This can affect on the regulators compensation and the resulting stability and dynamic response performance. Very low ESR and high capacitance must be used with care. A “rule of thumb” is that the total capacitance must never exceed typically 500-700 µF if only low ESR (< 2 mΩ) ceramic capacitors are used. If more capacitance is needed, a combination of low ESR type and electrolytic capacitors should be used, otherwise the stability will be affected. The PMB 4000 series regulator can accept up to 8 mF of capacitive load on the output at full load. This gives <500 µF/A of IO. When using that large capacitance it is important to consider the selection of output capacitors; the resulting behavior is a combination of the amount of capacitance and ESR. Minimum Required External Capacitors External input capacitors are required to increase the lifetime of the internal capacitors and to further reduce the input ripple. A minimum of 2x22 µF external input capaci-µF external input capaci-F external input capaci- tance with low ESR should be added. A minimum of 150 µF external output capacitance, low ESR,µF external output capacitance, low ESR,F external output capacitance, low ESR, should be added for the converter to operate properly at full load.

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Operating Information Parallel Operation The PMB 4000 Series DC/DC regulators can be connected in parallel with a common input. Paralleling is accomplished by connecting the output voltage pins directly and using a load sharing device on the input. Layout considerations should be made to avoid load imbalance. For more details on parallel- ing, please consult your local applications support. Input Undervoltage Lockout The PMB 4000 Series DC/DC regulators are equipped with a lockout function for low input voltage.When the input voltage is below the undervoltage lockout limit of the regulator it will shut off. When the input voltage increases above the lockout level the regulator will turn on. A combination of low ESR and output capacitance exceeding 8 mF can cause the regulator into over current protection mode (hick-up) due to high start up current. The output filter must therefore be designed without exceeding the above stated capacitance levels if the ESR is lower than 30-40 mΩ.

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Thermal Considerations General The PMB 4000 Series DC/DC regulators are designed to operate in a variety of thermal environments, however sufficient cooling should be provided to help ensure reliable operation. Heat is removed by conduction, convection and radiation to the surrounding environment. Increased airflow enhances the heat transfer via convection. Proper cooling can be verified by measuring the temperature at the reference point (Tref). Calculation of ambient temperature By using the thermal resistance the maximum allowed ambient temperature can be calculated. A. The powerloss is calculated by using the formula ((1/η ) - 1) × output power = power losses. η = efficiency of regulator. Example: 95% = 0.95 B. Find the value of the thermal resistance Rth Tref-A in the dia- gram by using the airflow speed at the module. Take the ther- mal resistance × powerloss to get the temperature increase. Thermal resistance vs. airspeed measured at the regulator. C. Max allowed calculated ambient temperature is: Max Tref of DC/DC regulator - temperature increase. Example: 5V input, 1.8 V output at 1m/s, full load: C. 90 °C - 28.8 °C = max ambient temperature is 61.2 °C The real temperature will be dependent on several factors, like PCB size and type, direction of airflow, air turbulence etc. It is recommended to verify the temperature by testing. 5SFG NBY«$ The PMB 4000 thermal testing is performed with the product mounted on an FR4 board 254 × 254 mm with 8× 254 mm with 8 254 mm with 8 layers of 35 µm copper. Airflow is perpendicular to the Tµm copper. Airflow is perpendicular to the Tm copper. Airflow is perpendicular to the Tref side. <NT> <«$8> 7JO 7PVU 7JO 7PVU 7JO 7PVU 7JO 7PVU 7JO7PVU 25 mm [1 in.] airflow Test board choke

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet The PMB 4000 series DC/DC regulators are intended for manual or wave soldering. The plastic body of the pin connectors resists soldering heat for limited time up to 260 °C.. When hand soldering, care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to avoid melting of the plastic. Soldering Information Delivery Package Information The PMB 4000 series regulators are delivered in antistatic trays with Jedec standard outer dimensions. Tray capacity 25 pcs. Each box contains 4 trays. Reliability The Mean Time Between Failure (MTBF) of the PMB 4000 series DC/DC regulator family is calculated to be greater than 6 million hours at full output power and a reference temperature of +40 °C using TelCordia SR 332. Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products include:

  • Lead in high melting temperature type solder (used to solder the die in semiconductor packages)
  • Lead in glass of electronics components and in electronic ceramic parts (e.g. fill material in chip resistors)
  • Lead as an alloying element in copper alloy containing up to 4% lead by weight (used in connection pins made of Brass)

EN/LZT 146 049 R4A ©Ericsson Power Modules, March 2007PMB 4518T WP Datasheet Sales Offices and Contact Information Company Headquarters Ericsson Power Modules AB LM Ericssons väg 30 SE-126 25 Stockholm Sweden Phone: +46-8-568-69620 Fax: +46-8-568-69599 China Ericsson Simtek Electronics Co.

33 Fuhua Road

Phone: +86-21-5990-3258 Fax: +86-21-5990-0188 North and South America Ericsson Inc. Power Modules 6300 Legacy Dr. Plano, TX 75024 USA Phone: +1-972-583-5254 +1-972-583-6910 Fax: +1-972-583-7839 Hong Kong (Asia Pacific) Ericsson Ltd. 12/F . Devon House

979 King’s Road

Phone: +852-2590-2453 Fax: +852-2590-7152 Italy, Spain (Mediterranean) Ericsson Power Modules AB Via Cadorna 71

20090 Vimodrone (MI)

Phone: +39-02-265-946-07 All other countries Contact Company Headquarters or visit our website: www.ericsson.com/powermodules Information given in this data sheet is believed to be accurate and reliable. No responsibility is assumed for the consequences of its use nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Ericsson Power Modules. These products are sold only according to Ericsson Power Modules’ general conditions of sale, unless otherwise confirmed in writing. Specifications subject to change without notice. Germany, Austria Ericsson Power Modules AB Mühlhauser Weg 18

85737 Ismaning

Phone: +49-89-9500-6905 Fax: +49-89-9500-6911 Japan Ericsson Power Modules AB Kimura Daini Building, 3 FL. 3-29-7 Minami-Oomachi, Shinagawa-ka Tokyo 140-0013 Japan Phone: +81-3-5733-5107 Fax: +81-3-5753-5162