PRODUCT SPECIFICATION 1 (4) Prepared (also subject responsible if other) No. EZHIXZH 1/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) MICJOHN 2011-02-24 C Key Features
- Industry standard Eighth-brick
- Low profile, max 8.10 mm (0.32 in.)
- High efficiency, typ. 90.6 % at half load
- 2250 Vdc input to output isolation
- Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950
- More than 4.7 million hours predicted MTBF at +40ºC ambient temperature General Characteristics
- Suited for narrow board pitch applications (15 mm/0.6 in)
- Output over voltage protection
- Input under voltage shutdown
- Over temperature protection
- Output short-circuit protection
- Remote sense
- Remote control
- Output voltage adjust function
- Highly automated manufacturing ensures quality
- ISO 9001/14001 certified supplier Safety Approvals Design for Environment Meets requirements in high- temperature lead-free soldering processes. Ericsson Internal TABLE OF CONTENTS 1 (2) Prepared (also subject responsible if other) No. EZHIXZH 001 52- EN/LZT 146 394 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) 2009-8-7 E
Contents
Product Program Ordering No. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (4) Prepared (also subject responsible if other) No. EZHIXZH 1/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) MICJOHN 2011-02-24 C General Information
Ordering Information
See Contents for individual product ordering numbers. Option Suffix Ordering No. Isolated Surface mount Positive Remote Control Logic Increased stand-off height Lead length 3.69 mm (0.145 in) Lead length 4.57 mm (0.180 in) SI P M LA LB PKB 4711 SINB PKB 4711 PIPNB PKB 4711 PINBM PKB 4711 PINBLA PKB 4711 PINBLB Note : As an example a positive logic, increased standoff, short pin product would be PKB 4711 PIPNBMLA. Reliability The failure rate (λ) and mean time between failures (MTBF= 1/λ) is calculated at max output power and an operating ambient temperature (TA) of +40°C. Ericsson Power Modules uses Telcordia SR-332 Issue 2 Method 1 to calculate the mean steady-state failure rate and standard deviation (σ). Telcordia SR-332 Issue 2 also provides techniques to estimate the upper confidence levels of failure rates based on the mean and standard deviation. Mean steady-state failure rate, λ Std. deviation, σ 214 nFailures/h 34.5 nFailures/h MTBF (mean value) for the PKB series = 4.7 Mh. MTBF at 90% confidence level = 3.9 Mh Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products are found in the Statement of Compliance document. Ericsson Power Modules fulfills and will continuously fulfill all its obligations under regulation (EC) No 1907/2006 concerning the registration, evaluation, authorization and restriction of chemicals (REACH) as they enter into force and is through product materials declarations preparing for the obligations to communicate information on substances in the products. Quality Statement The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of the products. Warranty Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson Power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’s health or life). © Ericsson AB 2013 The information and specifications in this technical specification is believed to be correct at the time of publication. However, no liability is accepted for inaccuracies, printing errors or for any consequences thereof. Ericsson AB reserves the right to change the contents of this technical specification at any time without prior notice. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (4) Prepared (also subject responsible if other) No. EZHIXZH 1/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) MICJOHN 2011-02-24 C Safety Specification General information Ericsson Power Modules DC/DC converters and DC/DC regulators are designed in accordance with safety standards IEC/EN/UL 60950-1 Safety of Information Technology Equipment. IEC/EN/UL 60950-1 contains requirements to prevent injury or damage due to the following hazards:
- Electrical shock
- Energy hazards
- Fire
- Mechanical and heat hazards
- Radiation hazards
- Chemical hazards On-board DC/DC converters and DC/DC regulators are defined as component power supplies. As components they cannot fully comply with the provisions of any safety requirements without “Conditions of Acceptability”. Clearance between conductors and between conductive parts of the component power supply and conductors on the board in the final product must meet the applicable safety requirements. Certain conditions of acceptability apply for component power supplies with limited stand-off (see Mechanical Information for further information). It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable safety standards and regulations for the final product. Component power supplies for general use should comply with the requirements in IEC 60950-1, EN 60950-1 and UL 60950-1 Safety of Information Technology Equipment. There are other more product related standards, e.g. IEEE 802.3 CSMA/CD (Ethernet) Access Method, and ETS-300132-2 Power supply interface at the input to telecommunications equipment, operated by direct current (dc), but all of these standards are based on IEC/EN/UL 60950-1 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL 60950-1 recognized and certified in accordance with EN 60950-1. The flammability rating for all construction parts of the products meet requirements for V-0 class material according to IEC 60695-11-10, Fire hazard testing, test flames — 50 W horizontal and vertical flame test methods. The products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. Normally the output of the DC/DC converter is considered as SELV (Safety Extra Low Voltage) and the input source must be isolated by minimum Double or Reinforced Insulation from the primary circuit (AC mains) in accordance with IEC/EN/UL 60950-1. Isolated DC/DC converters It is recommended that a slow blow fuse is to be used at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem that imposes a short circuit on the input source, this fuse will provide the following functions:
- Isolate the fault from the input power source so as not to affect the operation of other parts of the system.
- Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. The galvanic isolation is verified in an electric strength test. The test voltage (V iso) between input and output is 1500 Vdc or 2250 Vdc (refer to product specification).
24 V DC systems
The input voltage to the DC/DC converter is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and 60 V DC systems If the input voltage to the DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. Single fault testing in the input power supply circuit should be performed with the DC/DC converter connected to demonstrate that the input voltage does not exceed 75 Vdc. If the input power source circuit is a DC power system, the source may be treated as a TNV-2 circuit and testing has demonstrated compliance with SELV limits in accordance with IEC/EN/UL60950-1. Non-isolated DC/DC regulators The input voltage to the DC/DC regulator is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 1 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 01/74 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B Absolute Maximum Ratings Characteristics min typ max Unit Tref Operating Temperature (see Thermal Consideration section) -40 +120 °C TS Storage temperature -55 +125 °C VI Input voltage -0.5 +80 V Viso Isolation voltage (input to output test voltage) 2250 Vdc Vtr Input voltage transient (t p 100 ms) 100 V Positive logic option -0.5 6 V VRC Remote Control pin voltage (see Operating Information section) Negative logic option -0.5 40 V Vadj Adjust pin voltage (see Operating Information section) -0.5 2xVoi V Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified manner. Fundamental Circuit Diagram Bias supply Isolated Feedback Pri mary Driver + In RC - In + Out Se conda ry Driver Control and S uperv ision + Sense - Sense - Out Vadj Primary Secondary E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. ESECZHW 2/1301-BMR 636 01/E4 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) EZYPING 2009-8-5 A
1.0 V/30 A Electrical Specification PKB 4318N PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 31 32 V VIon Turn-on input voltage Increasing input voltage 33 34 35 V CI Internal input capacitance 2.65 μF PO Output power Output voltage initial setting 0 30 W 50 % of max IO 85.1 max IO 81.6 50 % of max IO, VI = 48 V 85.3 η Efficiency max IO, VI = 48 V 81.3 Pd Power Dissipation max I O 6.9 8.3 W Pli Input idling power IO = 0 A, VI = 53 V 1 W PRC Input standby power VI = 53 V (turned off with RC) 0.12 W fs Switching frequency 0-100 % of max IO 170 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 30 A 0.97 1.00 1.03 V Output adjust range See operating information 0.90 1.10 V Output voltage tolerance band 10-100 % of max I O 0.96 1.04 V Idling voltage IO = 0 A 0.96 1.04 V Line regulation max IO 0.2 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 3 10 mV Vtr Load transient voltage deviation ±120 ±250 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs see Note 1 40 160 μs tr Ramp-up time (from 10−90 % of VOi) 0.1 0.5 2 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 1 2.4 7 ms max IO 0.06 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 8.1 s RC start-up time max IO 2.1 ms max IO 0.06 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 9.1 s IO Output current 0 30 A Ilim Current limit threshold Tref < max Tref 31 36 38 A Isc Short circuit current Tref = 25ºC, see Note 2 38.5 41 A VOac Output ripple & noise See ripple & noise section, max I O, VOi 40 80 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 1.15 1.3 1.6 V Note 1: (Cout used at load transient test; 15*470uF Polymer+1*470uF electrolytic) Note 2: See Operating Information section. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. ESECZHW 2/1301-BMR 636 01/E4 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) EZYPING 2009-8-5 A
1.0 V/30 A Typical Characteristics PKB 4318N PINB
Efficiency Power Dissipation 0 6 12 18 24 30 [A] [% ] 36 V 48 V 53 V 75 V 0 6 12 18 24 30 [A] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 2 04 06 08 0 1 0 0 [ ° C ] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53V. See Thermal Consideration section. Thermal resistance vs. airsp eed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics 0.96 0.98 1.00 1.02 1.04 0 5 10 15 20 25 [A] [V] 36 V 48 V 53 V 75 V 0.00 0.30 0.60 0.90 1.20 1.50 15 21 27 33 39 45 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. ESECZHW 2/1301-BMR 636 01/E4 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) EZYPING 2009-8-5 A Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.5 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 μs/div.). Output voltage response to load current step- change (7.5-22.5-7.5 A) at: Tref =+25°C, VI = 53 V. Top trace: output voltage (100 mV/div.). Bottom trace: load current (30 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: For a desired change of the nominal output voltage, the value of the resistor should be ) ( 1Ω −−= kV V VRadj adj oi adj Where adjV is adjusted output voltage, and oiV is initial output voltage. Vertical bars indicate absolute value. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 01/74 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B
1.2 V/30 A Electrical Specification PKB 4318 PIOBNB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30.6 30.9 31.1 V VIon Turn-on input voltage Increasing input voltage 33.6 34.0 34.2 V CI Internal input capacitance 2.65 μF PO Output power Output voltage initial setting 0 36 W 50 % of max IO 87 max IO 85 50 % of max IO, VI = 48 V 87 η Efficiency max IO, VI = 48 V 85 Pd Power Dissipation max I O 6.4 7.7 W Pli Input idling power IO = 0 A, VI = 53 V 1.2 W PRC Input standby power VI = 53 V (turned off with RC) 0.14 W fs Switching frequency 0-100 % of max IO 170 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 20 A 1.18 1.20 1.22 V Output adjust range See operating information 1.08 1.32 V Output voltage tolerance band 10-100 % of max I O 1.16 1.23 V Idling voltage IO = 0 A 1.16 1.23 V Line regulation max IO 3 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 3 10 mV Vtr Load transient voltage deviation ±260 ±320 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs 50 150 μs tr Ramp-up time (from 10−90 % of VOi) 4 7 10 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 7 13 43 ms max IO 0.04 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 8.1 s RC start-up time max IO 11.4 ms max IO 0.01 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 11 s IO Output current 0 30 A Ilim Current limit threshold Tref < max Tref 32 34 37 A Isc Short circuit current Tref = 25ºC, see Note 1 38.5 39 A VOac Output ripple & noise See ripple & noise section, max I O, VOi 50 80 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 1.4 1.5 1.8 V Note 1: Vo<0.5V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 01/74 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B 1.2V/30 A Typical Characteristics PKB 4318 PIOBNB Efficiency Power Dissipation 0 5 10 15 20 25 30 [A] [%] 36 V 48 V 53 V 75 V 0 5 10 15 20 25 30 [A] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 02 0 4 06 0 8 0 1 0 0 [ ° C ] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. ai rspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics 1.00 1.10 1.20 1.30 1.40 0 5 10 15 20 25 30 [A] [V] 36V 48V 53V 75V 0.00 0.40 0.80 1.20 1.60 15 20 25 30 35 40 45 50 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 01/74 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B 1.2V/30 A Typical Characteristics PKB 4318 PIOBNB Start-up Shut-down Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.1 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 μs/div.). Output voltage response to load current step- change (5.5-17.5-5.5 A) at: T ref =+25°C, VI = 53 V. Top trace: output voltage (200 mV/div.). Bottom trace: load current (10 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Output Voltage Adjust Downwards, Decrease: Example: Increase 4% =>Vout = 1.25 Vdc Decrease 4% =>Vout = 1.15 Vdc 1005.11 2 k 117.5k4 E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. ESHUHAN 2/1301-BMR 636 01/44 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EQUENXU 2008-4-8 A
1.5 V/30 A Electrical Specification PKB 4418 PIOANB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 31 32 V VIon Turn-on input voltage Increasing input voltage 33 34 35 V CI Internal input capacitance 2.65 μF PO Output power Output voltage initial setting 0 45 W 50 % of max IO 88.5 max IO 86.6 50 % of max IO, VI = 48 V 88.8 η Efficiency max IO, VI = 48 V 86.5 Pd Power Dissipation max IO 7.0 8.4 W Pli Input idling power IO = 0 A, VI = 53 V 1.3 W PRC Input standby power VI = 53 V (turned off with RC) 0.11 W fs Switching frequency 0-100 % of max IO 167 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 20 A 1.48 1.50 1.53 V Output adjust range See operating information 1.20 1.65 V Output voltage tolerance band 10-100 % of max IO 1.47 1.54 V Idling voltage IO = 0 A 1.47 1.54 V Line regulation max IO 3 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 3 10 mV Vtr Load transient voltage deviation ±350 ±400 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 3 A/μs 40 130 μs tr Ramp-up time (from 10−90 % of VOi) 1 9 14 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 4 12 22 ms max IO 0.04 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 13.9 s RC start-up time max IO 13.4 ms max IO 0.02 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 17 s IO Output current 0 30 A Ilim Current limit threshold Tref < max Tref 31 33 39 A Isc Short circuit current Tref = 25ºC, see Note 1 38 43 A VOac Output ripple & noise See ripple & noise section, max IO, VOi 50 80 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 1.8 1.9 2.1 V Note 1: Vo<0.5V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. ESHUHAN 2/1301-BMR 636 01/44 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EQUENXU 2008-4-8 A 1.5V/30 A Typical Characteristics PKB 4418 PIOANB Efficiency Power Dissipation 0 5 10 15 20 25 30 [A] [%] 36 V 48 V 53 V 75 V 0 5 10 15 20 25 30 [A] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 2 04 06 08 0 1 0 0 [ ° C ] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. ai rspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics 1.30 1.40 1.50 1.60 1.70 0 5 10 15 20 25 30 [A] [V] 36V 48V 53V 75V 0.00 0.40 0.80 1.20 1.60 15 20 25 30 35 40 45 50 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. ESHUHAN 2/1301-BMR 636 01/44 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EQUENXU 2008-4-8 A 1.5V/30 A Typical Characteristics PKB 4418 PIOANB Start-up Shut-down Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (5 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Top trace: output voltage (0.5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.1 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, IO = 30 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 μs/div.). Output voltage response to load current step- change (7.5-22.5-7. 5 A) at: T ref =+25°C, VI = 53 V. Top trace: output voltage (200 mV/div.). Bottom trace: load current (10 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Output Voltage Adjust Downwards, Decrease: Example: Increase 4% =>Vout = 1.56 Vdc Decrease 4% =>Vout = 1.44 Vdc 1005.11 2 k 117.5k4 E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
2 (5) Prepared (also subject responsible if other) No. EGLANDY 2/1301-BMR 636 01/64 Uen Approved Checked Date Rev Reference SEC/D (ALICE SU) ESECZHW 2008-6-19 A
1.8 V/25 A Electrical Specification PKB 4418 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 µF and Cout = 0 µF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 31 32 V VIon Turn-on input voltage Increasing input voltage 33 34 35 V CI Internal input capacitance 3.35 μF PO Output power Output voltage initial setting 0 45 W 50 % of max IO 90 max IO 89 50 % of max IO, VI = 48 V 89.5 η Efficiency max IO, VI = 48 V 89 Pd Power Dissipation max IO 5.5 7.5 W Pli Input idling power IO = 0 A, VI = 53 V 1.5 W PRC Input standby power VI = 53 V (turned off with RC) 0.12 W fs Switching frequency 0-100 % of max IO 195 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 25 A 1.76 1.8 1.83 V Output adjust range See operating information 1.44 1.98 V Output voltage tolerance band 10-100 % of max IO 1.76 1.84 V Idling voltage IO = 0 A 1.77 1.84 V Line regulation max IO 3 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 3 10 mV Vtr Load transient voltage deviation ±250 ±350 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs 30 100 µs tr Ramp-up time (from 10−90 % of VOi) 3 8 15 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 6 14 25 ms max IO 0.05 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 2.5 s RC start-up time max IO 12 ms max IO 0.04 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 2.5 s IO Output current 0 25 A Ilim Current limit threshold Tref < max Tref 26 30 35 A Isc Short circuit current Tref = 25ºC, see Note 1 35 38 A VOac Output ripple & noise See ripple & noise section, max IO, VOi 30 70 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 2.1 2.2 2.5 V Note 1: Vo<0.5V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
3 (5) Prepared (also subject responsible if other) No. EGLANDY 2/1301-BMR 636 01/64 Uen Approved Checked Date Rev Reference SEC/D (ALICE SU) ESECZHW 2008-6-19 A
1.8 V/25 A Typical Characteristics PKB 4418 PINB
Efficiency Power Dissipation 0 5 10 15 20 25[A] [%] 36 V 48 V 53 V 75 V 0 5 10 15 20 25[A] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 20 40 60 80 100[ °C] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics 1.70 1.75 1.80 1.85 1.90 0 5 10 15 20 25[A] [V] 36 V 48 V 53 V 75 V 0.00 0.50 1.00 1.50 2.00 2.50 15 20 25 30 35 40[A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
4 (5) Prepared (also subject responsible if other) No. EGLANDY 2/1301-BMR 636 01/64 Uen Approved Checked Date Rev Reference SEC/D (ALICE SU) ESECZHW 2008-6-19 A Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 25 A resistive load. Top trace: output voltage (1 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 25 A resistive load. Top trace: output voltage (1 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.1 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, IO = 25 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 µs/div.). Output voltage response to load current step- change (6.25-18.75-6.25 A) at: Tref =+25°C, VI = 53 V. Top trace: output voltage (200 mV/div.). Bottom trace: load current (10 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: ( ) −Δ−Δ × Δ + ×= 22 . 10% 511 % 225 . 1 % 100 8 . 1 11 . 5Radj kΩ Example: Increase 4% =>Vout = 1.872 Vdc ( ) − − + × 22 . 10 511 4 225 . 1 4 100 8 . 1 11 . 5 kΩ = 57.3 kΩ Output Voltage Adjust Downwards, Decrease: − Δ = 2 10011 . 5Radj kΩ Example: Decrease 20% =>Vout =1.44 Vdc −2 10011 . 5 kΩ = 15.3 kΩ E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EXUEFYA 2/1301-BMR 636 01/24 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ECHWANG 2008-5-21 A
2.5 V/25 A Electrical Specification PKB4619 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0µF and Cout = 0µF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 31 32 V VIon Turn-on input voltage Increasing input voltage 33 34 35 V CI Internal input capacitance 3.35 µF PO Output power Output voltage initial setting 0 62.5 W 50 % of max IO 89.6 max IO 89.5 50 % of max IO, VI = 48 V 90.0 η Efficiency max IO, VI = 48 V 89.5 Pd Power Dissipation max IO 7.4 9.4 W Pli Input idling power IO = 0 A, VI = 53 V 2.1 W PRC Input standby power VI = 53 V (turned off with RC) 0.118 W fs Switching frequency 0-100 % of max IO 198 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 15 A 2.45 2.5 2.55 V Output adjust range See operating information 2.00 2.75 V Output voltage tolerance band 10-100 % of max IO 2.40 2.60 V Idling voltage IO = 0 A 2.45 2.55 V Line regulation max IO 3 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 3 10 mV Vtr Load transient voltage deviation ±300 ±400 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/µs 50 200 µs tr Ramp-up time (from 10−90 % of VOi) 3 11 17 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 6 14 21 ms max IO 0.062 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 8 s RC start-up time max IO 12 ms max IO 0.13 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 8 s IO Output current 0 25 A Ilim Current limit threshold Tref < max Tref 27 31 35 A Isc Short circuit current Tref = 25ºC, 37 41 A VOac Output ripple & noise See ripple & noise section, max I O, VOi 40 80 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 2.9 3.1 4.0 V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EXUEFYA 2/1301-BMR 636 01/24 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ECHWANG 2008-5-21 A
2.5 V/25 A Typical Characteristics PKB4619 PINB
Efficiency Power Dissipation 0 5 10 15 20 25 [A] [%] 36 V 48 V 53 V 75 V 0 5 10 15 20 25 [A] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 20 40 60 80 100 [°C] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. ai rspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics 2.40 2.45 2.50 2.55 2.60 0 5 10 15 20 25 [A] [V] 36 V 48 V 53 V 75 V 0.50 1.50 2.50 3.50 25 27 29 31 33 35 37 39 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EXUEFYA 2/1301-BMR 636 01/24 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ECHWANG 2008-5-21 A Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 25 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 25 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.2 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, IO = 25 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 µs/div.). Output voltage response to load current step- change (6.25-18.75-6.25 A) at: T ref =+25°C, VI = 53 V. Top trace: output voltage (200 mV/div.). Bottom trace: load current (10 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: () ⎟ ∆ + ×= 22 . 10% 511 % 225 . 1 % 100 5 . 2 11 . 5Radj kΩ Example: Increase 10% =>Vout =2.75 Vdc () ⎟ ⎛ − −× + × 22 . 1010 511 10 225 . 1 10 100 5 . 2 11 . 5 kΩ = 53.39 kΩ Output Voltage Adjust Downwards, Decrease: ⎛ −∆= 2% 10011 . 5Radj kΩ Example: Decrease 20% =>Vout =2.00 Vdc ⎛ − 220 10011 . 5 kΩ = 15.33 kΩ E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. ECHWANG 2/1301-BMR 636 01/14 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 C
3.3 V/20 A Electrical Specification PKB 4610 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 30.8 32 V VIon Turn-on input voltage Increasing input voltage 33 34.0 35 V CI Internal input capacitance 2.65 μF PO Output power Output voltage initial setting 0 66 W 50 % of max IO 91.3 max IO 90.5 50 % of max IO, VI = 48 V 91.6 η Efficiency max IO, VI = 48 V 90.5 Pd Power Dissipation max IO 6.9 9.2 W Pli Input idling power IO = 0 A, VI = 53 V 1.6 W PRC Input standby power VI = 53 V (turned off with RC) 0.13 W fs Switching frequency 0-100 % of max IO 164 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 25 A 3.23 3.30 3.37 V Output adjust range See operating information 2.64 3.63 V Output voltage tolerance band 10-100 % of max IO 3.20 3.40 V Idling voltage IO = 0 A 3.20 3.40 V Line regulation max IO 0.2 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 0.4 10 mV Vtr Load transient voltage deviation ±320 ±500 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs 32 50 μs tr Ramp-up time (from 10−90 % of VOi) 2 8 30 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 7 12 60 ms max IO 0.08 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 5.2 s RC start-up time max IO 12 ms max IO 0.06 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 5.4 s IO Output current 0 20 A Ilim Current limit threshold Tref < max Tref 22 25 31 A Isc Short circuit current Tref = 25ºC, see Note 1 29 33 A VOac Output ripple & noise See ripple & noise section, max IO, VOi 43 80 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 3.7 4.1 4.7 V Note 1: See Operating Information section. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. ECHWANG 2/1301-BMR 636 01/14 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 C
3.3 V/20A Typical Characteristics PKB 4610 PINB
Efficiency Power Dissipation 0 4 8 12 16 20 [A] [%] 36 V 48 V 53 V 75 V 0 4 8 1 21 62 0 [ A ] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 20 40 60 80 100 [°C] [A] 3. 0 m /s 2. 5 m /s 2. 0 m /s 1. 5 m /s 1. 0 m /s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53V. See Thermal Consideration section. Thermal resistance vs. airsp eed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics 3.25 3.27 3.29 3.31 3.33 3.35 048 1 2 1 6 2 0 [ A ] [V] 36 V 48 V 53 V 75 V 0.00 0.80 1.60 2.40 3.20 4.00 10 14 18 22 26 30 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. ECHWANG 2/1301-BMR 636 01/14 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 C
3.3 V/20 A Typical Characteristics PKB 4610 PINB
Start-up enabled by connecting VI at: TP1 = +25°C, VI = 53 V, IO = 20 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (10 ms/div.). Shut-down enabled by disconnecting V I at: TP1 = +25°C, VI = 53 V, IO = 20 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.1 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: T IO = 20 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 μs/div.). Output voltage response to load current step- change (5-15-5 A) at: T Top trace: output voltage (200 mV/div.). Bottom trace: load current (10 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: () ⎟ ⎛ −Δ−Δ × Δ + ×= 22 . 10% 511 % 225 . 1 % 100 30 . 3 11 . 5Radj kΩ Example: Increase 4% =>Vout = 3.432 Vdc ⎛ − −× +× 22 . 104 511 4 225 . 1 4 100 30 . 3 11 . 5 kΩ = 220 kΩ Output Voltage Adjust Downwards, Decrease: Example: Decrease 4% =>Vout = 3.168Vdc 1005.11 2 k 117.5k4 Active adjust The output voltage may be adjusted using a {current/voltage} applied to the Vadj pin. This {current/voltage} is calculated by using the following equations: ⎛ −× + = 3 . 3 3 . 345 . 2 225 . 1VdesiredVadj V Example: Upwards => 3.40 V ⎛ −× + 3 . 3 Example: Downwards => 3.20 V ⎛ −× + 3 . 3 E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 04/14 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B
3.3 V/25 A Electrical Specification PKB 4810 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 30.9 32 V VIon Turn-on input voltage Increasing input voltage 33 34.1 35 V CI Internal input capacitance 3.35 μF PO Output power Output voltage initial setting 0 82.5 W 50 % of max IO 91.5 max IO 89.6 50 % of max IO, VI = 48 V 91.7 η Efficiency max IO, VI = 48 V 89.4 Pd Power Dissipation max I O 9.6 12 W Pli Input idling power IO = 0 A, VI = 53 V 1.6 W PRC Input standby power VI = 53 V (turned off with RC) 0.12 W fs Switching frequency 0-100 % of max IO 166 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 25 A 3.23 3.30 3.37 V Output adjust range See operating information 2.64 3.63 V Output voltage tolerance band 10-100 % of max I O 3.20 3.40 V Idling voltage IO = 0 A 3.20 3.40 V Line regulation max IO 0.3 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 3 10 mV Vtr Load transient voltage deviation ±265 ±500 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs 35 130 μs tr Ramp-up time (from 10−90 % of VOi) 2 9 30 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 7 12 60 ms max IO 0.06 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 6.2 s RC start-up time max IO 12 ms max IO 0.05 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 6.6 s IO Output current 0 25 A Ilim Current limit threshold Tref < max Tref 26 31 36 A Isc Short circuit current Tref = 25ºC, see Note 1 35 39 A VOac Output ripple & noise See ripple & noise section, max I O, VOi 40 80 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 3.7 4.1 4.7 V Note 1: See Operating Information section. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 04/14 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B
3.3 V/25A Typical Characteristics PKB 4810 PINB
Efficiency Power Dissipation 0 5 10 15 20 25 [A] [%] 36 V 48 V 53 V 75 V 0 5 10 15 20 25 [A] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 20 40 60 80 100 [°C] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53V. See Thermal Consideration section. Thermal resistance vs. airsp eed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics 3.25 3.27 3.29 3.31 3.33 3.35 0 5 10 15 20 25 [A] [V] 36 V 48 V 53 V 75 V 0.00 0.80 1.60 2.40 3.20 4.00 12 16 20 24 28 32 36 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 04/14 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B
3.3 V/25 A Typical Characteristics PKB 4810 PINB
Start-up enabled by connecting VI at: TP1 = +25°C, VI = 53 V, IO = 25 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (10 ms/div.). Shut-down enabled by disconnecting VI at: TP1 = +25°C, VI = 53 V, IO = 25 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.1 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: TP1 = +25°C, VI = 53 V, IO = 25 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 μs/div.). Output voltage response to load current step- change (6.25-18.75-6.25 A) at: T Top trace: output voltage (200 mV/div.). Bottom trace: load current (10 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: ⎛ − Δ Δ × Δ +×= 22 . 10 511 % 225 . 1 % 100 30 . 3 11 . 5Radj kΩ Example: Increase 4% =>Vout = 3.432 Vdc ⎛ − −× +× 22 . 104 511 4 225 . 1 4 100 30 . 3 11 . 5 kΩ = 220 kΩ Output Voltage Adjust Downwards, Decrease: Example: Decrease 4% =>V out = 3.168Vdc 1005.11 2 k 117.5k4 Active adjust The output voltage may be adjusted using a current/voltage applied to the Vadj pin. This current/voltage is calculated by using the following equations: ⎞⎜⎝ ⎛ −× + = 30 . 3 30 . 345 . 2 225 . 1VdesiredVadj V Example: Upwards => 3.40 V ⎞⎜⎝ ⎛ −× + 30 . 3 Example: Downwards => 3.20 V ⎞⎜⎝ ⎛ −× + 30 . 3 E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 01/34 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B
5.0 V/15 A Electrical Specification PKB4711 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0μF and Cout = 0μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 29.9 31.0 32.2 V VIon Turn-on input voltage Increasing input voltage 33.2 34.2 35.0 V CI Internal input capacitance 2.65 μF PO Output power Output voltage initial setting 0 75 W 50 % of max IO 90.5 max IO 89.9 50 % of max IO, VI = 48 V 90.9 η Efficiency max IO, VI = 48 V 89.9 Pd Power Dissipation max I O 8.5 10.9 W Pli Input idling power IO = 0 A, VI = 53 V 2.2 W PRC Input standby power VI = 53 V (turned off with RC) 0.125 W fs Switching frequency 0-100 % of max IO 198 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 15 A 4.90 5.0 5.10 V Output adjust range See operating information 4.00 5.50 V Output voltage tolerance band 10-100 % of max I O 4.97 5.14 V Idling voltage IO = 0 A 4.97 5.14 V Line regulation max IO 1 3.1 mV VO Load regulation VI = 53 V, 0-100 % of max IO 1 2.7 mV Vtr Load transient voltage deviation ±300 490 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs 25 50 μs tr Ramp-up time (from 10−90 % of VOi) 7 10 12 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 10 12 14 ms max IO 0.12 0.14 0.16 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 4.2 4.5 5.2 s RC start-up time max IO 10 ms max IO 0.13 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 4.5 s IO Output current 0 15 A Ilim Current limit threshold Tref < max Tref 19 A Isc Short circuit current Tref = 25ºC, 22 25 A VOac Output ripple & noise See ripple & noise section, max I O, VOi 50 80 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 6 7 V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 01/34 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B
5.0 V/15 A Typical Characteristics PKB4711 PINB
Efficiency Power Dissipation 0 3 6 9 12 15 [A] [%] 36 V 48 V 53 V 75 V 0369 1 2 1 5 [ A ] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 2 04 06 08 0 1 0 0[ ° C ] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. ai rspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics 4.90 4.95 5.00 5.05 5.10 0369 1 2 1 5 [ A ] [V] 36 V 48 V 53 V 75 V 0.50 1.50 2.50 3.50 4.50 5.50 12 15 18 21 24 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EZYPING 2/1301-BMR 636 01/34 Uen Approved Checked Date Rev Reference SEC/D (Betty Wu) ESECZHW 2009-2-9 B Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 15 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 15 A resistive load. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.2 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, IO = 15 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 μs/div.). Output voltage response to load current step- change (3.75-11.25-3.75 A) at: T ref =+25°C, VI = 53 V. Top trace: output voltage (200 mV/div.). Bottom trace: load current (10 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Δ Δ ⋅ +−Δ ⋅ Δ + ⋅= % % 2 100 % 225 . 1 %) 100 (* 11 . 5oVRadj kΩ Example: Increase 4% =>Vout = 5.2 Vdc () ⎟ ⎛ × +− 4 2 100 4 225 . 1 4 100 0 . 5* 11 . 5 kΩ = 404.3 kΩ Output Voltage Adjust Downwards, Decrease: Example: Decrease 4% =>Vout = 4.8Vdc 1005.11 2 k 117.5k4 Active adjust The output voltage may be adjusted using a {current/voltage} applied to the Vadj pin. This {current/voltage} is calculated by using the following equations: ⎛ −× + = 5 545 . 2 225 . 1VdesiredVadj V Example: Upwards => 5.1 V ⎞⎜⎝ ⎛ −× +5 5 1 . 545 . 2 225 . 1V = 1.274 V Example: Downwards => 4.9 V ⎛ −× + 5 5 9 . 445 . 2 225 . 1 V = 1.176 V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EMAOLII 2/1301-BMR 636 01/54 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ESHNMAA 2013-08-20 C
12 V/6 A Electrical Specification PKB 4713 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 31.1 32 V VIon Turn-on input voltage Increasing input voltage 33 34.1 35 V CI Internal input capacitance 3.35 μF PO Output power Output voltage initial setting 0 72 W η Efficiency 50 % of max IO 90.6 max IO 90.7 50 % of max IO, VI = 48 V 91.1 max IO, VI = 48 V 90.8 Pd Power Dissipation max I O 7.5 11 W Pli Input idling power IO = 0 A, VI = 53 V 2.4 W PRC Input standby power VI = 53 V (turned off with RC) 0.12 W fs Switching frequency 0-100 % of max IO 200 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 6 A 11.80 12.0 12.25 V VO Output adjust range See operating information 9.6 13.2 V Output voltage tolerance band 10-100 % of max I O 11.75 12.30 V Idling voltage IO = 0 A 11.75 12.30 V Line regulation max IO 2 20 mV Load regulation VI = 53 V, 0-100 % of max IO 1 10 mV Vtr Load transient voltage deviation VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs ±380 ±500 mV ttr Load transient recovery time 20 100 μs tr Ramp-up time (from 10−90 % of VOi) 10-100 % of max IO 6 9.5 18 ms ts Start-up time (from VI connection to 90 % of VOi) 8 13 20 ms tf VI shut-down fall time (from VI off to 10 % of VO) max IO 0.4 ms IO = 0 A 2.1 s tRC RC start-up time max I O 10.5 ms RC shut-down fall time (from RC off to 10 % of VO) max IO 0.4 ms IO = 0 A 2.1 s IO Output current 0 6 A Ilim Current limit threshold T ref < max Tref 6.6 7.4 9 A Isc Short circuit current Tref = 25ºC, see Note 1 8.2 10 A VOac Output ripple & noise See ripple & noise section, max IO, VOi 70 100 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 14 15 16 V Note 1: See Operating Information section. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EMAOLII 2/1301-BMR 636 01/54 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ESHNMAA 2013-08-20 C
12 V/6 A Typical Characteristics PKB 4713 PINB
Efficiency Power Dissipation 0123456 [ A ] [%] 36 V 48 V 53 V 75 V 0123456 [ A ] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 2 04 06 08 0 1 0 0 [°C] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics 11.90 11.95 12.00 12.05 12.10 0123456 [ A ] [V] 36 V 48 V 53 V 75 V 0.00 3.00 6.00 9.00 12.00 15.00 3456789 [ A ] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EMAOLII 2/1301-BMR 636 01/54 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ESHNMAA 2013-08-20 C Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 6 A resistive load. Top trace: output voltage (5 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: (10 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 6 A resistive load. Top trace: output voltage (5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.5 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: T ref = +25°C, VI = 53 V, IO = 6 A resistive load. Trace: output voltage (20 mV/div.). Time scale: (2 μs/div.). Output voltage response to load current step- change (1.5-4.5-1.5 A) at: T ref =+25°C, VI = 53 V. Top trace: output voltage (500 mV/div.). Bottom trace: load current (2 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: %) 2 100 ( % 225 . 1 % 100 1211 . 5Radj Example: Increase 2% =>Vout = 12.24 Vdc ) 2 * 2 100 ( 2 225 . 1 2 100 1211 . 5Radj k = 2287.2 k Output Voltage Adjust Downwards, Decrease: Example: Decrease 4% =>Vout = 11.52Vdc 1005.11 2 k 117.5k4 Active adjust The output voltage may be adjusted using a {current/voltage} applied to the Vadj pin. This {current/voltage} is calculated by using the following equations: 1245 . 2 225 . 1VdesiredVadj V Example: Upwards => 12.50 V 12 50 . 1245 . 2 225 . 1 V = 1.327 V Example: Downwards => 12.50 V 12 12 50 . 1145 . 2 225 . 1 V = 1.123 V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EMAOLII 2/1301-BMR 636 02/54 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EZHIXZH 2012-07-24 E 12 V/7.5 A Electrical Specification PKB 4913 PINB Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 μF and Cout = 0 μF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 31.7 32 V VIon Turn-on input voltage Increasing input voltage 33 34.0 35 V CI Internal input capacitance 3.35 μF PO Output power Output voltage initial setting 0 90 W 50 % of max IO 90.5 max IO 89.4 50 % of max IO, VI = 48 V 91.2 η Efficiency max IO, VI = 48 V 89.5 Pd Power Dissipation max I O 10.8 W Pli Input idling power IO = 0 A, VI = 53 V 2.4 W PRC Input standby power VI = 53 V (turned off with RC) 0.1 W fs Switching frequency 0-100 % of max IO 200 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 6 A 11.80 12 12.25 V Output adjust range See operating information 9.6 13.2 V Output voltage tolerance band 10-100 % of max I O 11.75 12.30 V Idling voltage IO = 0 A 11.75 12.30 V Line regulation max IO 1.6 20 mV VO Load regulation V I = 53 V, 0-100 % of max IO 1 10 mV Vtr Load transient voltage deviation ±380 ±550 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/μs 20 100 μs tr Ramp-up time (from 10−90 % of VOi) 5 7.7 18 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 7 11.3 20 ms max IO 0.3 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 2.2 s RC start-up time max IO 9 ms max IO 0.3 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 2.2 s IO Output current 0 7.5 A Ilim Current limit threshold Tref < max Tref 7.9 9.6 12 A Isc Short circuit current Tref = 25ºC, see Note 1 10 13 A VOac Output ripple & noise See ripple & noise section, max I O, VOi 50 100 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 14 15 17 V Note 1: See Operating Information section. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EMAOLII 2/1301-BMR 636 02/54 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EZHIXZH 2012-07-24 E 12 V/7.5A Typical Characteristics PKB 4913 PINB Efficiency Power Dissipation 02468 [ A ] [%] 36 V 48 V 53 V 75 V 02468 [ A ] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0.0 1.5 3.0 4.5 6.0 7.5 9.0 0 20 40 60 80 100 [°C] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53V. See Thermal Consideration section. Thermal resistance vs. airsp eed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics 11.90 11.94 11.98 12.02 12.06 12.10 02468 [ A ] [V] 36 V 48 V 53 V 75 V 0.00 3.00 6.00 9.00 12.00 15.00 [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EMAOLII 2/1301-BMR 636 02/54 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EZHIXZH 2012-07-24 E 12 V/7.5 A Typical Characteristics PKB 4913 PINB Start-up Shut-down Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 7.5 A resistive load. Top trace: output voltage 5 V/div.. Bottom trace: input voltage 50 V/div.. Time scale: 5 ms/div.. Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, Io =7.5A resistive load. Top trace: output voltage 5 V/div. Bottom trace: input voltage 50 V/div.. Time scale: 0.5 ms/div.. Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, Io = 7.5 A resistive load. Trace: output voltage 20 mV/div. Time scale: 2 μs/div. Output voltage response to load current step- change 1.875A-5.625A-1.875A at: Tref =+25°C, VI = 53 V. Top trace: output voltage 500 mV/div. Bottom trace: load current 5 A/div). Time scale: 0.1 ms/div.. Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: % %) 2 100 ( % 225 . 1 % 100 1211 . 5Radj Example: Increase 2% =>Vout = 12.24 Vdc 2 ) 2 * 2 100 ( 2 225 . 1 2 100 1211 . 5Radj k = 2287.2 k Output Voltage Adjust Downwards, Decrease: Example: Decrease 4% =>Vout = 11.52Vdc 1005.11 2 k 117.5k4 Active adjust The output voltage may be adjusted using a {current/voltage} applied to the Vadj pin. This {current/voltage} is calculated by using the following equations: 1245 . 2 225 . 1VdesiredVadj V Example: Upwards => 12.50 V 12 12 50 . 1245 . 2 225 . 1 V = 1.327 V Example: Downwards => 11.50 V 12 12 50 . 1145 . 2 225 . 1 V = 1.123 V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EYINGJI 2/1301-BMR 636 01/84 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EXUEFYA 2008-6-6 A
15 V/5 A Electrical Specification PKB 4715 PINB
Tref = -40 to +90ºC, VI = 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions. Typical values given at: Tref = +25°C, VI= 53 VI max IO, unless otherwise specified under Conditions. Additional Cin = 0 µF and Cout = 0 µF. See Operating Information section for selection of capacitor types. Characteristics Conditions min typ max Unit VI Input voltage range 36 75 V VIoff Turn-off input voltage Decreasing input voltage 30 31 32 V VIon Turn-on input voltage Increasing input voltage 33 34 35 V CI Internal input capacitance 3.35 µF PO Output power Output voltage initial setting 0 75 W 50 % of max IO 91.0 max IO 92.0 50 % of max IO, VI = 48 V 91.5 η Efficiency max IO, VI = 48 V 92.1 Pd Power Dissipation max IO 6.7 10 W Pli Input idling power IO = 0 A, VI = 53 V 2.4 W PRC Input standby power VI = 53 V (turned off with RC) 0.15 W fs Switching frequency 0-100 % of max IO 195 kHz VOi Output voltage initial setting and accuracy Tref = +25°C, VI = 53 V, IO = 20 A 14.70 15 15.30 V Output adjust range See operating information 12.00 16.50 V Output voltage tolerance band 10-100 % of max IO 14.55 15.45 V Idling voltage IO = 0 A 14.55 15.45 V Line regulation max IO 3 10 mV VO Load regulation VI = 53 V, 0-100 % of max IO 3 10 mV Vtr Load transient voltage deviation ±400 ±520 mV ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 3 A/µs 10 20 µs tr Ramp-up time (from 10−90 % of VOi) 5 10 15 ms ts Start-up time (from VI connection to 90 % of VOi) 10-100 % of max IO 4 15 80 ms max IO 0.5 ms tf VI shut-down fall time (from VI off to 10 % of VO) IO = 0 A 1.5 s RC start-up time max IO 10 ms max IO 0.5 ms tRC RC shut-down fall time (from RC off to 10 % of VO) IO = 0 A 1.5 s IO Output current 0 5 A Ilim Current limit threshold Tref < max Tref 5.3 6 6.8 A Isc Short circuit current Tref = 25ºC, see Note 1 8.4 8.5 A VOac Output ripple & noise See ripple & noise section, max I O, VOi 70 150 mVp-p OVP Over voltage protection Tref = +25°C, VI = 53 V, 0-100 % of max IO 18 19 20 V Note 1: Vo<0.5V E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EYINGJI 2/1301-BMR 636 01/84 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EXUEFYA 2008-6-6 A
15 V/5 A Typical Characteristics PKB 4715 PINB
Efficiency Power Dissipation 012345 [A] [%] 36 V 48 V 53 V 75 V 012345 [A] [W] 36 V 48 V 53 V 75 V Efficiency vs. load current and input voltage at Tref = +25°C Dissipated power vs. load current and input voltage at Tref = +25°C Output Current Derating Thermal Resistance 0 2 04 06 08 0 1 0 0 [°C] [A] 3.0 m/s 2.5 m/s 2.0 m/s 1.5 m/s 1.0 m/s Nat. Conv. [°C/W] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. ai rspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. VI = 53 V. Output Characteristics Current Limit Characteristics 14.90 14.95 15.00 15.05 15.10 012345 [ A ] [V] 36 V 48 V 53 V 75 V 0.00 3.00 6.00 9.00 12.00 15.00 56789 1 0 [A] [V] 36 V 48 V 53 V 75 V O utput voltage vs. load current at Tref = +25°C Output voltage vs. load current at IO > max IO , Tref = +25°C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EYINGJI 2/1301-BMR 636 01/84 Uen Approved Checked Date Rev Reference SEC/D (Julia You) EXUEFYA 2008-6-6 A Start-up enabled by connecting VI at: Tref = +25°C, VI = 53 V, IO = 5 A resistive load. Top trace: output voltage (5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (5 ms/div.). Shut-down enabled by disconnecting VI at: Tref = +25°C, VI = 53 V, IO = 5 A resistive load. Top trace: output voltage (5 V/div.). Bottom trace: input voltage (50 V/div.). Time scale: (0.2 ms/div.). Output Ripple & Noise Output Load Transient Response Output voltage ripple at: Tref = +25°C, VI = 53 V, IO = 5 A electrical load. Trace: output voltage (20 mV/div.). Time scale: (2 µs/div.). Output voltage response to load current step- change ((1.25-3.75-1.25A) at: T ref =+25°C, VI = 53 V. Top trace: output voltage (2 V/div.). Bottom trace: load current (2 A/div.). Time scale: (0.1 ms/div.). Output Voltage Adjust (see operating information) Passive adjust The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: () Ω⎟ 511 % 225 . 1 % 100 15 11 . 5 Output Voltage Adjust Downwards, Decrease: Example: Increase 4% =>Vout = 15.6 Vdc () Ω= Ω⎟ ⎛ − −× + × kk 90 . 148822 . 104 511 4 225 . 1 4 100 15 11 . 5 Decrease 4% =>Vout = 14.4 Vdc 1005.11 2 k 117.5k4 E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 1 (5) Prepared (also subject responsible if other) No. EJUNGYA 3/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ESHUHAN 2008-1-11 A EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC part 15J (see test set-up). See Design Note 009 for further information. The fundamental switching frequency is 198 kHz for PKB4711 SINB @ VI = 53 V, max IO. Conducted EMI Input terminal value (typ) EMI without filter External filter (class B) Required external input filter in order to meet class B in EN 55022, CISPR 22 and FCC part 15J. Filter components: C1 = 0.68 µF C2,3 = 1.0 µF C4,5 = 2.2 nF C6,7 = 100 µF L1,2 = 0.77 mH EMI with filter Test set-up Layout recommendation The radiated EMI performance of the DC/DC converter will depend on the PCB layout and ground layer design. It is also important to consider the stand-off of the DC/DC converter. If a ground layer is used, it should be connected to the output of the DC/DC converter and the equipment ground or chassis. A ground layer will increase the stray capacitance in the PCB and improve the high frequency EMC performance. Output ripple and noise Output ripple and noise measured according to figure below. See Design Note 022 for detailed information. Output ripple and noise test setup E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 2 (5) Prepared (also subject responsible if other) No. EJUNGYA 3/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ESHUHAN 2008-1-11 A Operating information Input Voltage The input voltage range 36 to 75Vdc meets the requirements of the European Telecom Standard ETS 300 132-2 for normal input voltage range in 48 and 60 Vdc systems, -40.5 to - 57.0 V and 50.0 to -72 V respectively. At input voltages exceeding 75 V, the power loss will be higher than at normal input voltage and T ref must be limited to absolute max +110°C. The absolute maximum continuous input voltage is 80 Vdc. Turn-off Input Voltage The DC/DC converters monitor the input voltage and will turn on and turn off at predetermined levels. The minimum hysteresis between turn on and turn off input voltage is 3V. Remote Control (RC) The products are fitted with a remote control function referenced to the primary negative input connection (- In), with negative and positive logic options available. The RC function allows the converter to be turned on/off by an external device like a semiconductor or mechanical switch. The RC pin has an internal pull up resistor to Vcc pin of controller IC. The maximum required sink current is 1 mA. When the RC pin is left open, the voltage generated on the RC pin is around 6 V. The second option is positive logic remote control, which can be ordered by adding the suffix P to the end of the part number. The converter will turn on when the input voltage is applied with the RC pin open. Turn off is achieved by connecting the RC pin to the - In. To ensure safe turn off the voltage difference between RC pin and the - In pin shall be less than 1V. The converter will restart automatically when this connection is opened. See Design Note 021 for detailed information. Input and Output Impedance The impedance of both the input source and the load will interact with the impedance of the DC/DC converter. It is important that the input source has low characteristic impedance. The converters are designed for stable operation without external capacitors connected to the input or output. The performance in some applications can be enhanced by addition of external capacitance as described under External Decoupling Capacitors. If the input voltage source contains significant inductance, the addition of a 100 µF capacitor across the input of the converter will ensure stable operation. The capacitor is not required when powering the DC/DC converter from an input source with an inductance below 10 µH. External Decoupling Capacitors When powering loads with significant dynamic current requirements, the voltage regulation at the point of load can be improved b y addition of decoupling capacitors at the load. The most effective technique is to locate low ESR ceramic and electrolytic capacitors as close to the load as possible, using several parallel capacitors to lower the effective ESR. The ceramic capacitors will handle high-frequency dynamic load changes while the electrolytic capacitors are used to handle low frequency dynamic load changes. Ceramic capacitors will also reduce any high frequency noise at the load. It is equally important to use low resistance and low inductance PCB layouts and cabling. External decoupling capacitors will become part of the control loop of the DC/DC converter and may affect the stability margins. As a rule of thumb, 100 µF/A of output current can be added without any additional analysis. The ESR of the capacitors is a very important parameter. Power Modules guarantee stable operation with a verified ESR value of >10 mΩ across the output connections. For further information please contact your local Ericsson Power Modules representative. Output Voltage Adjust (Vadj) The DC/DC converters have an Output Voltage Adjust pin (Vadj). This pin can be used to adjust the output voltage above or below Output voltage initial setting. When increasing the output voltage, the voltage at the output pins (including any remote sense compensation ) must be kept below the threshold of the over volta ge protection, (OVP) to prevent the converter from shutting down. At increased output voltages the maximum power rating of the converter remains the same, and the max output current must be decreased correspondingly. To increase the voltage the resistor should be connected between the V adj pin and +Sense pin. The resistor value of the Output voltage adjust function is according to information given under the Output section for the respective product. To decrease the output voltage, the resistor should be connected between the Vadj pin and Sense pin. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 3 (5) Prepared (also subject responsible if other) No. EJUNGYA 3/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ESHUHAN 2008-1-11 A Operating information continued Parallel Operation Two converters may be paralleled for redundancy if the total power is equal or less than PO max. It is not recommended to parallel the converters without using external current sharing circuits. See Design Note 006 for detailed information. Remote Sense The DC/DC converters have remote sense that can be used to compensate for voltage drops between the output and the point of load. The sense traces should be located close to the PCB ground layer to reduce noise susceptibility. The remote sense circuitry will compensate for up to 10% voltage drop between output pins and the point of load. If the remote sense is not needed +Sense should be connected to +Out and -Sense should be connected to -Out. Over Temperature Protection (OTP) The converters are protected from thermal overload by the control IC. When T ref as defined in thermal consideration section exceeds 135°C the converter will shut down. The DC/DC converter will make continuous attempts to start up (non- latching mode) and resume normal operation automatically when the temperature has dropped >10°C below the temperature threshold. Over Voltage Protection (OVP) The converters have output over voltage protection that will shut down the converter in over voltage conditions. The converter will make continuous attempts to start up (non- latching mode) and resume normal operation automatically after removal of the over voltage condition. Over Current Protection (OCP) The converters include current limiting circuitry for protection at continuous overload. The output voltage will decrease towards zero for output currents in excess of max output current (max I O). The converter will resume normal operation after removal of the overload. The load distribution should be designed for the maximum output short circuit current specified. Thermal Consideration General The converters are designed to operate in different thermal environments and sufficient cooling must be provided to ensure reliable operation. Cooling is achieved mainly by conduction, from the pins to the host board, and convection, which is dependant on the airflow across the converter. Increased airflow enhances the cooling of the converter. The Output Current Derating graph found in the Output section for each model provides the available output current vs. ambient air temperature and air velocity at V in = 53 V. The DC/DC converter is tested on a 254 x 254 mm, 35 µm (1 oz), 8-layer test board mounted vertically in a wind tunnel with a cross-section of 305 x 305 mm. Proper cooling of the DC/DC converter can be verified by measuring the temperature at positions P1, P2 and P3. The temperature at these positions should not exceed the max values provided in the table below. Note that the max value is the absolute maximum rating (non destruction) and that the electrical Output data is guaranteed up to T ref +90°C. See Design Note 019 for further information. Position Device Designation max value P1 Pcb 110º C P2 Mosfet 120º C P3 Mosfet Tref 120º C E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPECIFICATION 4 (5) Prepared (also subject responsible if other) No. EJUNGYA 3/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) ESHUHAN 2008-1-11 A Thermal Consideration continued Definition of reference temperature (Tref) The reference temperature is used to monitor the temperature limits of the product. Temperatures above maximum Tref are not allowed and may cause degradation or permanent damage to the product. Tref is also used to define the temperature range for normal operating conditions. Tref is defined by the design and used to guarantee safety margins, proper operation and high reliability of the module. Ambient Temperature Calculation By using the thermal resistance the maximum allowed ambient temperature can be calculated. 1. The power loss is calculated by using the formula ((1/η) - 1) × output power = power losses (Pd). η = efficiency of converter. E.g 89.0 % = 0.89 2. Find the thermal resistance (Rth) in the Thermal Resistance graph found in the Output section for each model. Calculate the temperature increase (∆T). ∆T = Rth x Pd 3. Max allowed ambient temperature is: Max Tref - ∆T. E.g PKB 4711 SINB at 1m/s: 3. 120 °C 58.3°C = max ambient temperature is 61.6°C The actual temperature will be dependent on several factors such as the PCB size, number of layers and direction of airflow. Connections Pin Designation Function 1 +In Positive input
2 RC Remote control
5 -Sen Negative remote sense
6 Vadj Output voltage adjust
7 +Sen Positive remote sense 8 +Out Positive output 0.89 E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPEC. MECHANICAL 1 (3) Prepared (also subject responsible if other) No. EPEIHLI 4/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) See §1 2012-06-21 D Mechanical Information - Surface mount version All component placements – whether shown as physical components or symbolical outline – are for reference only and are subject to change throughout the product’s life cycle, unless explicitly described and dimensioned in this drawing. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PRODUCT SPEC. MECHANICAL 2 (3) Prepared (also subject responsible if other) No. EPEIHLI 4/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D (Julia You) See §1 2012-06-21 D Mechanical Information- Through hole mount version All component placements – whether shown as physical components or symbolical outline – are for reference only and are subject to change throughout the product’s life cycle, unless explicitly described and dimensioned in this drawing. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PROD. SPECIFICATION MECHANICAL 1 (4) Prepared (also subject responsible if other) No. EPANHON 5/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D [Julia You] See §1 2007-10-15 B Soldering Information - Surface Mounting The surface mount version of the product is intended for convection or vapor phase reflow SnPb and Pb-free processes. To achieve a good and reliable soldering result, make sure to follow the recommendations from the solder paste supplier, to use state-of-the-art reflow equipment and reflow profiling techniques as well as the following guidelines. A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board. The cleanin g residues may affect long time reliability and isolation voltage. Minimum Pin Temperature Recommendations Pin number 4 is chosen as reference location for the minimum pin temperature recommendations since this will likely be the coolest solder joint during the reflow process. Pin 4 for measurement of minimum solder joint temperature, TPIN Pin 2 for measurement of maximum peak product reflow temperature, TP SnPb solder processes For SnPb solder processes, a pin temperature (TPIN) in excess of the solder melting temperature, (TL, +183°C for Sn63/Pb37) for more than 30 seconds, and a peak temperature of +210°C is recommended to ensure a reliable solder joint. Lead-free (Pb-free) solder processes For Pb-free solder processes, a pin temperature (TPIN) in excess of the solder melting temperature (TL, +217 to +221°C for Sn/Ag/Cu solder alloys) for more than 30 seconds, and a peak temperature of +235°C on all solder joints is recommended to ensure a reliable solder joint. Peak Product Temperature Requirements Pin number 2 is chosen as reference location for the maximum (peak) allowed product temperature (T P) since this will likely be the warmest part of the product during the reflow process. To avoid damage or performance degradation of the product, the reflow profile should be optimized to avoid excessive heating. A sufficiently extended preheat time is recommended to ensure an even temperature across the host PCB, for both small and large devices. To reduce the risk of excessive heating is also recommended to reduce the time in the reflow zone as much as possible. SnPb solder processes For SnPb solder processes, the product is qualified for MSL 1 according to IPC/JEDEC standard J-STD-020C. During reflow, T P must not exceed +225°C at any time. Lead-free (Pb-free) solder processes For Pb-free solder processes, the product is qualified for MSL 3 according to IPC/JEDEC standard J-STD-020C. During reflow, T P must not exceed +260°C at any time. 25 °C Time Temperature Ramp-down (cooling) Ramp-up Reflow Preheat Time 25 °C to peak TP TL Reflow process specifications Sn/Pb eutectic Pb-free Average ramp-up rate 3°C/s max 3°C/s max Solder melting temperature (typical) TL +183°C +221°C Minimum time above TL 30 s 30 s Minimum pin temperature T PIN +210°C +235°C Peak product temperature T P +225°C +260°C Average ramp-down rate 6°C/s max 6°C/s max Time 25°C to peak 6 minutes max 8 minutes max E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PROD. SPECIFICATION MECHANICAL 2 (4) Prepared (also subject responsible if other) No. EPANHON 5/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D [Julia You] See §1 2007-10-15 B Soldering Information — Through Hole Mounting The through hole mount version of the product is intended for manual or wave soldering. When wave soldering is used, the temperature on the pins is specified to maximum 270°C for maximum 10 seconds. A maximum preheat rate of 4°C/s and a temperature of max +150°C is suggested. When soldering by hand, care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to prevent overheating. A no-clean flux is recommended to avoid entrapment of cleaning fluids in cavities inside the product or between the product and the host board. The cleanin g residues may affect long time reliability and isolation voltage. Delivery Package Information, Surface Mount Version The surface mount versions of the products are delivered in antistatic injection molded trays (Jedec design guide 4.10D standard. Tray Specifications Material PPE, Antistatic Surface resistance 105 < Ohm/square < 1012 Bakability The trays can be baked at maximum 125°C for 48 hours Tray capacity 20 products/tray Tray thickness 13.4 mm [0.528 inch] Box capacity 100 products (5 full trays/box) Tray weight 110 g empty, 530 g full tray Delivery Package Information, Through Hole Mounting Version The products are delivered in antistatic clamshell. Clamshell Specifications Material PET with antistatic coated Surface resistance 106 < Ohm/square < 1012 Bake ability The clamshells are not bake-able. Clamshell capacity 20 products/clamshell Clamshell thickness 20 mm [0.787 inch] Box capacity 100 products (5 full trays/box) Clamshell weight 130 g empty, 530 g full tray Non-Dry Pack Information The through hole mount version of product is delivered in non-dry packing clamshells. Dry Pack Information The surface mount versions of the products are delivered in trays These inner shipment containers are dry packed in standard moisture barrier bags according to IPC/JEDEC standard J-STD-033 (Handling, packing, shipping and use of moisture/reflow sensitivity surface mount devices). Using products in high temperature Pb-free soldering processes requires dry pack storage and handling. In case the products have been stored in an uncontrolled environment and no longer can be considered dry, the modules must be baked according to J-STD-033. E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation
PROD. SPECIFICATION MECHANICAL 3 (4) Prepared (also subject responsible if other) No. EPANHON 5/1301-BMR 636 Uen Approved Checked Date Rev Reference SEC/D [Julia You] See §1 2007-10-15 B Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature (Temperature cycling) IEC 60068-2-14 Na Temperature range Number of cycles Dwell/transfer time -40 to +100°C 1000 15 min/0-1 min Cold (in operation) IEC 60068-2-1 Ad Temperature TA Duration -45°C 72 h Damp heat IEC 60068-2-67 Cy Temperature Humidity Duration +85°C 85 % RH 1000 hours Dry heat IEC 60068-2-2 Bd Temperature Duration +125°C 1000 h Electrostatic discharge susceptibility IEC 61340-3-1, JESD 22-A114 IEC 61340-3-2, JESD 22-A115 Human body model (HBM) Machine Model (MM) Class 2, 2000 V Class 3, 200 V Immersion in cleaning solvents IEC 60068-2-45 XA Method 2 Water Glycol ether Isopropyl alcohol +55°C +35°C +35°C Mechanical shock IEC 60068-2-27 Ea Peak acceleration Duration 100 g 6 ms Moisture reflow sensitivity 1 J-STD-020C Level 1 (SnPb-eutectic) Level 3 (Pb Free) 225°C 260°C Operational life test MIL-STD-202G method 108A Duration 1000 h Resistance to soldering heat 2 IEC 60068-2-20 Tb Method 1A Solder temperature Duration 270°C 10-13 s Robustness of terminations IEC 60068-2-21 Test Ua1 IEC 60068-2-21 Test Ue1 Through hole mount products Surface mount products All leads All leads Solderability IEC 60068-2-58 test Td IEC 60068-2-20 test Ta 2 Preconditioning Temperature, SnPb Eutectic Temperature, Pb-free Preconditioning Temperature, SnPb Eutectic Temperature, Pb-free 150°C dry bake 16 h 215°C 235°C Steam ageing 235°C 245°C Vibration, broad band random IE C 60068-2-64 Fh, method 1 Frequency Spectral density Duration 10 to 500 Hz 0.07 g 2/Hz 10 min in each perpendicular direction Note 1: Only for products intended for reflow soldering (surface mount products) Note 2: Only for products intended for wave soldering (plated through hole products) E PKB 4000 series DC/DC converters, Input 36-75 V, Output 30 A/90 W EN/LZT 146 394 R5D October 2013 © Ericsson AB Technical Specifi cation