PGE60801 ERICSSON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Erbium-Doped Fiber Amplifier for Digital Applications PGE 608 01

Description

The PGE 608 01 is an integrated, output power-locked amplifier. It has optically isolated input and output ports as well as input and output power monitoring. The serial and parallel interface is provided through a DB-25 electrical connector. The modules are based on industry standard platforms and are optimized for single channel SDH/SONET applications. Key Features

  • Operating wavelength window: 1530-1560 nm
  • Saturation output power: +10 dBm
  • Noise figure, typ. <7.0 dB
  • Serial (RS-232) interface with parallel alarms

Applications

  • Single channel digital applications (SDH/SONET)

Electrical and optical characteristics at recommended operating conditions, unless otherwise noted. Parameter Conditions Symbol Min Typ Max Unit Operating wavelength λL 1530 1560 nm Input power P in -6 dBm Output power At 1550 nm, P in = -6 dBm, at RT P out 9.5 10.0 10.5 dBm Input/output return loss Over T c and λL. EDFA turned on. IRL/ORL ≥ 28 dB Pin = -6dBm Noise figure < -6 dBm Input, at RT NF < 7.0 dB Small signal gain 20 dB

Electrical Characteristics

Parameter Conditions Symbol Min Typ Max Unit Operating current Positive Voltage 2 A Negative Voltage 1 A Operating voltage Pins # 12 and 24 4.75 5.00 5.50 V Pins #11 and 23 –5.50 –5.00 –4.75 V Ripple and noise On both Positive and Negative Voltage 2% PP Transients – positive V Max. Duration 75 ms 4.5 6.0 V Transients – negative Max. Duration 75 ms -6.0 -4.5 V Power dissipation Over operating temperature and time 10 W Operating Conditions Parameter Symbol Min Typ Max Unit Operating Case Temperature T Case 06 5 °C Absolute Maximum Ratings Parameter Symbol Min Max Unit Storage Temperature -40 75 ºC CAUTION: Stresses outside those listed in ”Absolute Maximum Ratings” may cause permanent damage to the device.

Ericsson Microelectronics AB SE-164 81 Kista, Sweden Telephone: +46 8 757 50 00 www.ericsson.com/microelectronics For local sales contacts, please refer to our website or call: Int + 46 8 757 47 00, Fax: +46 8 757 47 76 1522-PGE 608 01 Rev. E © Ericsson Microelectronics AB, October 2000 Information given in this data sheet is believed to be accurate and reliable. However no responsibility is assumed for the consequences of its use nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Ericsson Microelectronics. These products are sold only according to Ericsson Microelectronics' general conditions of sale, unless otherwise confirmed in writing. Product specifications subject to change without notice. Handling Precautions This device may be damaged as a result of electrostatic discharge (ESD). Take proper precautions during both han- dling and testing. This typically includes grounded wrist wraps, workbenches and floor mats in ESD controlled areas. Semiconductor devices may be damaged by current surges, use appropriate transient protection. Quality Assurance Ericsson Microelectronics commitment to quality has been proven through a decade of semiconductor device produc- tion and has been confirmed to ISO 9001. Opto product qualification is made according to the intention of applicable Telcordia standards. Connector Options SC/SPC SC/APC (Other connectors available on request) INVISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM DANGERDANGER WAVELENGTH 1300 nm - 1600 nm CLASS 3B LASER