LM135 SS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

www.siliconsupplies.com Die Size (Unsawn) 1500 x 1050 59 x 41 µm mils Minimum Bond Pad Size 104 x 104 4.09 x 4.09 µm mils Die Thickness 350 (±20) 13.78 (±0.79) µm mils Top Metal Composition Al 1%Si 1.1µm Back Metal Composition N/A – Bare Si Analog Temperature Sensor – LM135 Single-supply linear-output temperature sensor in bare die form  Wide temperature range: -55 to +150°C  0.5% typical accuracy at 25°C  Single-point calibration for high precision  Operates from 450μA to 5mA  <1Ω dynamic impedance  Linear output  Intermittent operation capability at 200°C  Small size for high integration Rev 1.1 28/04/20 Features: Supply Formats: Mechanical Specification  Default – Die in Waffle Pack (400 per tray capacity)  Sawn Wafer on Tape – On request  Unsawn Wafer – On request  Die Thickness <> 350µm(14 Mils) – On request  Assembled into Hermetic Package – On request The LM135 precision linear-output temperature sensor is designed for simple calibration and ease of use. Output is derived from an integrated 2-terminal Zener with a breakdown voltage directly proportional to absolute temperature at 10mV/°K. Calibrated at +25°C, the LM135 has an accuracy of 0.5°C over a wide -55°C to 150°C temperature range. With less than 1Ω dynamic impedance, performance is consistent across a current range of 450μA to 5mA. The device suits use as a general purpose sensor where its small size, low impedance and linear output enables simple circuit integration.

Description

The following part suffixes apply:  No suffix - MIL-STD-883 /2010B Visual Inspection  “ H” - MIL-STD-883 /2010B Visual Inspection + MIL-PRF-38534 Class H LAT  “ K” - MIL-STD-883 /2010A Visual Inspection (Space) + MIL-PRF-38534 Class K LAT LAT = Lot Acceptance Test. For further information on LAT process flows see below. www.siliconsupplies.com\\quality\\bare-die-lot-qualification For a higher electrical grade version of this product see LM135A Ordering Information Die Dimensions in µm (mils) 1500 (59) 1050 (41) A ll data sheet.com

www.siliconsupplies.com d Analog Temperature Sensor – LM135 Rev 1.1 28/04/20 COORDINATES (µm) PAD FUNCTION X Y

1 V+ 134 848

2 V- 1281 103

3 ADJ 1268 848

CONNECT CHIP BACK TO V- OR FLOAT Pad Layout and Functions Simplified Schematic 1500µm (59.06 mils) 1050µm (41.34mils) Calibration methodology and schematic 0,0 3 1 VOUT 10mV/°K The LM135 response is proportional to absolute temperature with the extrapolated output of sensor going to 0V at 0°K (-273.15°C). Errors in output voltage versus temperature are only slope. Thus a calibration of the slope at one temperature corrects errors at all temperatures. The circuit output (calibrated or not) is given by the equation: VOUTT + VOUTTo x Where:  T is the unknown temperature  T O is the reference temperature (in °K). Nominally, the output is calibrated at 10mV/°K. T To Application Note: Self-heating can decrease accuracy; LM135 should be operated at low current but sufficient enough to drive the sensor and calibration circuit to the maximum operating temperature. If used in surroundings where the thermal resistance is constant, the errors due to self-heating can be externally calibrated. This is possible if the circuit is biased with a temperature stable current. Heating will then be proportional to Zener voltage and therefore temperature. In this way, the error due to self-heating is proportional to the absolute temperature as scale factor errors. VOUT 10mV/°K 10kΩ* * Calibrated for 2.982V at 25°C A ll data sheet.com

www.siliconsupplies.com Analog Temperature Sensor – LM135 Rev 1.1 28/04/20 PARAMETER SYMBOL MIN MAX UNITS Continuous -55 150 Temperature Intermittent TA -55 200 Forward Current IF 0.45 5 mA Recommended Operating Conditions Absolute Maximum Ratings1 LIMITS PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Output Voltage VOUT TJ = 25°C, IR = 1mA 2.95 2.98 3.01 V ΔT1 TA = 25°C, IR = 1mA - 1 3 °C Un-calibrated Temperature Error ΔT2 -55˚C≤ TA≤ +150˚C,IR = 1mA - 2 5 °C ΔT3 -55˚C≤ TA≤ +150˚C,IR = 1mA - 0.5 1.5 °C 25°C Calibrated Temperature Error ΔT4 TA = 200˚C, Intermittent - 2 - °C Non-linearity ΔT5 -55˚C≤ TA≤ +150˚C,IR = 1mA - 0.3 1 °C Temperature Parameters2 (TA = 25°C unless otherwise specified) 1. Operation above the absolute maximum rating may cause device failure. Operation at the absolute maximum ratings, for extended periods, may reduce device reliability. PARAMETER SYMBOL VALUE UNIT Reverse Current IR 15 mA Forward Current IF 10 mA Continuous -55 to +150 Operating Temperature TOPER Intermittent -55 to +200 Storage Temperature TSTG -65 to +150 °C LIMITS PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Output voltage change with current ΔVOUT 450µA ≤ IR ≤ 5mA, Constant temperature - 2.5 10 mV Dynamic impedance ΔR1 TJ = 25°C, IR = 1mA - 0.5 - Ω Temperature coefficient of output voltage TC TJ = 25°C, IR = 1mA - +10 - mV/°C Still air - 80 - Air 0.5m/s - 10 - Time constant τТ Stirred oil - 1 - s Time stability TSTAB T J = 125°C - 0.2 - °C/1000h Electrical Parameters2 (TA = 25°C unless otherwise specified) 2. Accuracy measurements are made in a well-stirred oil bath. For other conditions, self-heating must be considered. A ll data sheet.com

www.siliconsupplies.com DISCLAIMER: The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics. With respect to any examples or hints given herein, any typical values stated herein and/or any information regarding the application of the device, Silicon Supplies Ltd hereby disclaims any and all warranties and liabilities of any kind. LIFE SUPPORT POLICY: Silicon Supplies Ltd components may be used in life support devices or systems only with the express written approval of Silicon Supplies Ltd, if a failure of such components can reasonably be expected to cause the failure of that life support device or system or to affect the safety or effectiveness of that device or system. Life support devices or systems are intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. Analog Temperature Sensor – LM135 Rev 1.1 28/04/20Circuit schematic pF pF A ll data sheet.com