Features

❏ Operating voltage of to up to 80V ❏ HVCMOS technology for high performance ❏ High speed source driver ❏ Up to 3.3MHz data input rate ❏ 5.0V CMOS logic circuitry ❏ Excellent noise immunity ❏ Flexible high voltage supplies

Symbol Parameter Min Typ Max Units Conditions IDSS Output leakage current -5.0 -15 µAV OUT = 0V, TA = +70°C HVOH Output voltage 78 78.5 V IOUT = -25mA, VPP = 80V TA = +25°C HVOH Output Voltage 77 78 V IOUT = -25mA, VPP = 80V TA = +125°C HVOL Output Voltage V DD = 5V 1.5 3.0 V I OUT = 1.0mA, TA = +25°C HVOL Output Voltage V DD = 5V 2.3 4.0 V I OUT = 1.0mA, TA = +125°C ISINK Output pull-down current V DD = 5V 2.0 3.5 mA V OUT = 5.0V to VPP VIH Logic input voltage V DD = 5V 3.5 5.3 V VIL Logic input voltage -0.3 0.8 V IIH Logic input current V DD = 5V 0.05 0.5 µAV IN = VDD IIL Logic input current V DD = 5V -0.05 -0.5 µAV IN = 0.8V VOH Serial data out V DD = 5V 4.5 4.7 V I OUT = -200µA VOL Serial data out V DD = 5V 200 250 mV I OUT = 200µA fCLK Maximum clock frequency V DD = 5V 8.0 MHz T J = +25°C VDD = 5V 5.0 MHz T J = +125°C IDDQ Supply current V DD = 5V 100 300 µA All outputs high VDD = 5V 100 300 µA All outputs low IPPQ Supply current 10 100 µA Outputs high, no Load 10 100 µA Outputs low, no Load

Electrical Characteristics

DC Characteristics (Over recommended operating conditions, TA = 25°C, unless otherwise noted) Symbol Parameter Min Nom Max Units VDD Supply voltage 4.5 5.5 V VPP Supply voltage 20 80 V TJ Operating junction temperature -40 +125 °C Power-up sequence should be the following: 1. Connect ground. 2. Apply V DD. 3. Set all inputs (Data, CLK, etc.) to a known state. 4. Apply V PP. 5. The V PP should not drop below VDD or float during operation. Power-down sequence should be the reverse of the above. Recommended Operating Conditions

Symbol Parameter Min Typ Max Units Conditions tPHL Blanking to output delay V DD = 5V 2000 ns C L = 30pF, 50% to 50% tPLH Blanking to output delay V DD = 5V 1000 ns C L = 30pF, 50% to 50% tf Output fall time V DD = 5V 1450 ns C L = 30pF, 90% to 10% tr Output rise time V DD = 5V 650 ns C L = 30pF, 10% to 90% tsu Data set-up time 75 ns See timing diagram th Data hold time 75 ns See timing diagram tpwd Minimum data pulse width 150 ns See timing diagram tpwclk Minimum clock pulse width 150 ns See timing diagram tcks Minimum time between clock activation 300 ns See timing diagram and strobe tpws Minimum strobe pulse width 100 ns See timing diagram tsto Typical time between strobe activation 500 ns See timing diagram and output transition AC Characteristics (TA = 25°C, over operating conditions unless otherwise noted) Input and Output Equivalent Circuits VDD Input GND VPP L/T GND HVOUT Logic Inputs GND Data Out Logic Data Output High Voltage Outputs VDD

Serial Clock Shift Register Contents Serial Strobe Latch Content Blanking Output Content Data Input Data Input HL to H H R 1 R2 ... RN-2 RN-1 RN-1 LL to H L R 1 R2 ... RN-2 RN-1 RN-1 XH to L R 1 R2 R3 ... RN-1 RN RN Note: L = Low Logic Level H = High Logic Level X = Irrelevant P= Present State R = Previous State Timing Diagram CLK Data In Strobe Blanking HVOUT tpwclk tpws tPHL tftr tPLH tsu 50% 50% 50% 90% 90% 10% 50% 10% th tpwd tcks tsto

2 Data Out

10 HV OUT13

11 HV OUT12

12 HV OUT11

13 Blank

14 GND

15 Clock

16 Strobe

18 HV OUT9

19 HV OUT8

20 HV OUT7

21 HV OUT6

22 HV OUT5

23 HV OUT4

24 HV OUT3

25 HV OUT2

26 HV OUT1

27 Data In

28-pin PLCC, 28-pin DIP, and SOW-28 25 19 24 23 22 21 20 5 116789 1 0 top view 28-pin PLCC top view 28-pin DIP and SOW-28 Package Outlines

1235 Bordeaux Drive, Sunnyvale, CA 94089

TEL: (408) 744-0100 • FAX: (408) 222-4895 www.supertex.com 11/12/01 ©2001 Supertex Inc. All rights reserved. Unauthorized use or reproduction prohibited.