UGE0421AY4 IXYS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 16

Technical content

Reg. Nr. 2743-02 Edition 97

2 ª 1997 IXYS All rights reserved Symbols and Definitions a Acceleration IF(AV)M Maximum mean forward current IF(RMS) Maximum RMS forward current IFSM Surge forward current IR Repetitive peak reverse current M d Mounting torque PRSM Maximum surge reverse power dissipation rT Forward slope resistance (for power loss calculations only) Tamb Ambient temperature or temperature of the cooling medium Tstg Storage temperature T(vj) Viritual junction temperature VdT DC voltage at VV(RMS) arithmetic mean VF Forward voltage VRRM Maximum repetitive peak reverse voltage VV(RMS) Supply voltage, RMS value VTO Threshold voltage (for power loss calculations only) a Rüttelfestigkeit IF(AV)M Maximaler Durchlaßstrom-Mittelwert IF(RMS) Höchstzulässiger Effektiv-Durchlaßstrom IFSM Maximaler Stoßstrom IR Sperrstrom M d Anzugsdrehmoment PRSM Maximale Stoßsperrverlustleistung rT Ersatzwiderstand (nur zur Berechnung der Verlustleistung) Tamb Umgebungstemperatur oder Kühlmitteltemperatur Tstg Lagertemperatur T(vj) Sperrschichttemperatur VdT Typgleichspannung bei VV(RMS) arithm. Mittelwert VF Durchlaßspannung VRRM Höchstzul. periodische Spitzensperrspannung VV(RMS) Typische Anschlußspannung (Effektivwert) VTO Schleusenspannung (nur zur Berechnung der Verlustleistung) Kurzzeichen und Begriffe Example: UGE 0421 AY4 U High Voltage rectifier, U-Series G Uncontrolled rectifier E One way circuit B One phase bridge circuit D Three phase bridge circuit Code, number of power semiconductors 0 1- 4 1 5- 6 2 7-12 4 Code, max. average forward current in A 1 < 3 A; 2 < 12 A; 3 < 16 A; 4 < 33 A etc.

2 Code, type of built in power

1 Code, max. RMS voltage 1 > 1 KV; 2 > 2 KV; 3 > 3 KV etc. A Letter, A = avalanche diode Y4Version (see dimension drawing) Y4 = round housing, A-N = plastic housing Nomenclature for High Voltage Rectifiers Beispiel: UGE 0421 AY4 U Hochspannungs-Gleichrichter, Baureihe U G Ungesteuerter Gleichrichter E Einwegschaltung B Einphasen-Brückenschaltung D Dreiphasen-Brückenschaltung Kennziffer, Anzahl der Leistungshalbleiter 0 1- 4 1 5- 6 2 7-12

4 Kennziffer, Dauergrenzstrom in A

1 < 3 A; 2 < 12 A; 3 < 16 A; 4 < 33 A usw.

2 Kennziffer, Art der eingebauten Dioden

1 Kennziffer, Anschlußspannung

1 > 1 KV; 2 > 2 KV; 3 > 3 KV usw. A Buchstabe, A = Avalanche-Diode Y4Gehäusebauform (siehe Maßbild) Y4 = runder Becher, A-N = Kunststoff- becher

3IXYS reserve the right to change limits, test conditions and dimensions. Contents/Inhalt Page Seite Symbols and Definitions / Kurzzeichen und Begriffe 2 Typ V RRM VV(RMS) IF(AV)M IFSM T(vj)m Weight Dimensions 45°°°°°C Gewicht Maßbild 10 ms VV A A °°°°°C UGB 3132 AD 4800 2250 1.3 60 150 150 1 UGB 6124 AG 10500 5000 1.0 50 150 300 1 UGD 6123 AG 7200 3300 1.8 50 150 300 2 UGD 8124 AG 10500 5000 1.2 50 150 300 2 Typ a b c d e f g h i k UGB 3132 AD 80 70 57 58.5 260 6 15 15 15 UGB 6124 AG 135 125 112 58.5 260 11 32.5 25 32.5 UGB 6123 AG 135 125 112 58.5 260 8 30 18 18 30 UGB 8124 AG 135 125 112 58.5 260 8 30 18 18 30 Type V RRM VV(RMS) IF(AV)M IFSM Typ 45°C 10 ms VVA A UGB 3132 AD 4800 2250 1.3 60 3 UGB 6124 AG 10500 5000 1.0 50 3 UGD 6123 AG 7200 3300 1.8 50 3 UGD 8124 AG 10500 5000 1.2 50 3 UGE 0421 AY4 3200 1125 23/7.4 300 4 - 5 UGE 0221 AY4 4800 1750 10/3.8 180 6 - 7 UGE 1112 AY4 8000 3000 4.2/2.0 120 8 - 9 UGE 3126 AY4 24000 9000 2.0/0.8 70 10 - 11 UGB Circuit configuration Schaltbild Technical data, application notes / Technische Daten, Applikationshinweise 12 - 13 Mounting instructions / Montagehinweise 15 - 15 IXYS International Sales Representatives 16 UGD 1~ / 3~ High Voltage Rectifier Modules Hochspannungs-Gleichrichter-Module

Dimensions in mm (1 mm = 0.0394") Anode Kathode

Features

  • Hermetically sealed Epoxy
  • Use in oil
  • Avalanche characteristics

Applications

  • X-Ray equipment
  • Electrostatic dust precipitators
  • Electronic beam welding
  • Lasers
  • Cable test equipment Advantages
  • Simple mounting
  • Improved temperature and power cycling
  • Reduced protection circuits
  • Series and parallel operation ª 1997 IXYS All rights reserved Data according to IEC 747-2 Symbol Test Conditions Ratings IF(RMS) 40 A IF(AV)M air self cooling, Tamb = 45°C - without cooling plate 7.4 A - with colling plate 10.9 A forced air cooling: v = 3 m/s, T amb = 35°C - without cooling plate 14.2 A - with cooling plate 18.8 A oil cooling, T amb = 35°C - without cooling plate 19.7 A - with cooling plate 22.9 A P RSM T(vj)= 150°C; t p = 10 µs 7 kW IFSM non repetitive, 50 c/s (for 60 c/s add 10%) T(vj)= 45°C; t p = 10 ms 300 A T(vj)= 150°C; t p = 10 ms 250 A Tamb -40...+150 °C Tstg -40...+150 °C T(vj) 150 °C Weight 115 g Symbol Test Conditions Characteristic Values IR T(vj) = 150°C; V R = VRRM ≤ 2 mA VF IF = 55 A 2.72 V T(vj) = 25°C VTO T(vj) = 150°C 1.7 V rT T(vj) = 150°C 16 m Ω a f = 50Hz 5 x 9,81 m/s 2 M d 8N m High Voltage Rectifiers V RRM = 3200 V Hochspannungsgleichrichter V dT = 500 V IF(AV)M = 22.9 A VRRM VV(RMS) VdT Standard Power Designation V V V Types 3200 1125 500 UGE 0421 AY4 Si-E 1125 / 500-6 UGE 0421 AY4

5IXYS reserve the right to change limits, test conditions and dimensions. Fig. 1: Forward characteristics Instantaneous forward current IF as a function of instantaneous forward voltage drop VF for junction temperature T(vj) = 25°C and T(vj) = 150°C a = Mean value characteristic b = Limit value characteristic Fig. 2: Characteristics of maximum permissible current The curves show the non repetitive peak one cycle surge forward current I FSM as a function of time t and serve for rating protective devices. a = Initial state T (vj) = 45°C b = Initial state T(vj) = 150°C Fig. 3: Power loss Non repetitive peak reverse power loss PRSM as a function of time t, T(vj) = 150°C Fig. 4: Load diagramm Mean forward current IF(AV) of one module for a sine half wave for various cooling modes as a function of the cooling medium temperature Tamb for a resistive load (horizontal mounting). Cooling modes 1 = air self cooling without cooling plate 2 = air self cooling with cooling plate 3 = forced air cooling without cooling plate 4 = forced air coolingwith cooling plate 5 = oil cooling w ithout cooling plate 6 = oil cooling with cooling plate 10-6 10-5 10-4 10-3 10-2 102 103 104 s t W PRSM 100 V VF A IF ab 10-3 10-2 10-1 100 101 100 150 200 250 300 s t A IFSM 0 20 40 60 80 100 120 140 TA A IF(AV) 180° IFAV T(vj) = 150°C T(vj) = 25°C b a UGE 0421 AY4

Dimensions in mm (1 mm = 0.0394") Anode Kathode

  • Hermetically sealed Epoxy
  • Use in oil
  • Avalanche characteristics
  • X-Ray equipment
  • Electrostatic dust precipitators
  • Electronic beam welding
  • Lasers
  • Cable test equipment Advantages
  • Simple mounting
  • Improved temperature and power cycling
  • Reduced protection circuits
  • Series and parallel operation ª 1997 IXYS All rights reserved Data according to IEC 747-2 Symbol Test Conditions Ratings IF(RMS) 16 A IF(AV)M air self cooling, Tamb = 45°C - without cooling plate 3.8 A - with colling plate 5.4 A forced air cooling: v = 3 m/s, T amb = 35°C - without cooling plate 7.0 A - with cooling plate 10.2 A oil cooling, T amb = 35°C - without cooling plate 10.2 A - with cooling plate 10.2 A P RSM T(vj)= 150°C; t p = 10 µs 3.4 kW IFSM non repetitive, 50 c/s (for 60 c/s add 10%) T(vj)= 45°C; t p = 10 ms 180 A T(vj)= 150°C; t p = 10 ms 140 A Tamb -40...+150 °C Tstg -40...+150 °C T(vj) 150 °C Weight 120 g Symbol Test Conditions Characteristic Values IR T(vj) = 150°C; V R = VRRM ≤ 2 mA VF IF = 30 A 4.8 V T(vj) = 25°C VTO T(vj) = 150°C 2.55 V rT T(vj) = 150°C 90 m Ω a f = 50Hz 5 x 9,81 m/s 2 M d 8N m High Voltage Rectifiers V RRM = 4800 V Hochspannungsgleichrichter V dT = 775 V IF(AV)M = 10.2 A VRRM VV(RMS) VdT Standard Power Designation V V V Types 4800 1750 775 UGE 0221 AY4 Si-E 1750 / 775-4 UGE 0221 AY4

7IXYS reserve the right to change limits, test conditions and dimensions. Fig. 1: Forward characteristics Instantaneous forward current IF as a function of instantaneous forward voltage drop VF for junction temperature T(vj) = 25°C and T(vj) = 150°C a = Mean value characteristic b = Limit value characteristic Fig. 2: Characteristics of maximum permissible current The curves show the non repetitive peak one cycle surge forward current I FSM as a function of time t and serve for rating protective devices. a = Initial state T (vj) = 45°C b = Initial state T(vj) = 150°C Fig. 3: Power loss Non repetitive peak reverse power loss PRSM as a function of time t, T(vj) = 150°C Fig. 4: Load diagramm Mean forward current IF(AV) of one module for a sine half wave for various cooling modes as a function of the cooling medium temperature Tamb for a resistive load (horizontal mounting). Cooling modes 1 = air self cooling without cooling plate 2 = air self cooling with cooling plate 3 = forced air cooling without cooling plate 4 = forced air coolingwith cooling plate 5 = oil cooling w ithout cooling plate 6 = oil cooling with cooling plate 0 30 60 90 120 150 TA A IF(AV) V VF A IF 10-3 10-2 10-1 100 101 100 150 200 s t A IFSM a b a b 10-6 10-5 10-4 10-3 10-2 102 103 104 s t W PRSM 180° IFAV T(vj) = 150°C T(vj) = 25°C UGE 0221 AY4

Dimensions in mm (1 mm = 0.0394") Anode Kathode

  • Hermetically sealed Epoxy
  • Use in oil
  • Avalanche characteristics
  • X-Ray equipment
  • Electrostatic dust precipitators
  • Electronic beam welding
  • Lasers
  • Cable test equipment Advantages
  • Simple mounting
  • Improved temperature and power cycling
  • Reduced protection circuits
  • Series and parallel operation ª 1997 IXYS All rights reserved Data according to IEC 747-2 Symbol Test Conditions Ratings IF(RMS) 7A IF(AV)M air self cooling, Tamb = 45°C - without cooling plate 2.0 A - with colling plate 2.5 A forced air cooling: v = 3 m/s, T amb = 35°C - without cooling plate 3.2 A - with cooling plate 4.1 A oil cooling, T amb = 35°C - without cooling plate 4.2 A - with cooling plate 4.2 A P RSM T(vj)= 150°C; t p = 10 µs 2.5 kW IFSM non repetitive, 50 c/s (for 60 c/s add 10%) T(vj)= 45°C; t p = 10 ms 120 A T(vj)= 150°C; t p = 10 ms 100 A Tamb -40...+150 °C Tstg -40...+150 °C T(vj) 150 °C Weight 122 g Symbol Test Conditions Characteristic Values IR T(vj) = 150°C; V R = VRRM ≤ 1 mA VF IF = 7 A 6.25 V T(vj) = 25°C VTO T(vj) = 150°C 4.25 V rT T(vj) = 150°C 0.215 m Ω a f = 50Hz 5 x 9,81 m/s 2 M d 8N m High Voltage Rectifiers V RRM = 8000 V Hochspannungsgleichrichter V dT = 1300 V IF(AV)M = 4.2 A VRRM VV(RMS) VdT Standard Power Designation V V V Types 8000 3000 1300 UGE 1112 AY4 Si-E 3000 / 1300-2.5 UGE 1112 AY4

9IXYS reserve the right to change limits, test conditions and dimensions. Fig. 1: Forward characteristics Instantaneous forward current IF as a function of instantaneous forward voltage drop VF for junction temperature T(vj) = 25°C and T(vj) = 150°C a = Mean value characteristic b = Limit value characteristic Fig. 2: Characteristics of maximum permissible current The curves show the non repetitive peak one cycle surge forward current I FSM as a function of time t and serve for rating protective devices. a = Initial state T (vj) = 45°C b = Initial state T(vj) = 150°C Fig. 3: Power loss Non repetitive peak reverse power loss PRSM as a function of time t, T(vj) = 150°C Fig. 4: Load diagramm Mean forward current IF(AV) of one module for a sine half wave for various cooling modes as a function of the cooling medium temperature Tamb for a resistive load (horizontal mounting). Cooling modes 1 = air self cooling without cooling plate 2 = air self cooling with cooling plate 3 = forced air cooling without cooling plate 4 = forced air coolingwith cooling plate 5 = oil cooling w ithout cooling plate 6 = oil cooling with cooling plate 0 30 60 90 120 150 TA A IF(AV) V VF A IF 10-3 10-2 10-1 100 101 100 120 s t A IFSM 10-6 10-5 10-4 10-3 10-2 101 102 103 104 s t W PRSM a T(vj) = 150°C T(vj) = 25°C b a b 180° IFAV5+6 UGE 1112 AY4

Dimensions in mm (1 mm = 0.0394") Anode Kathode

  • Hermetically sealed Epoxy
  • Use in oil
  • Avalanche characteristics
  • X-Ray equipment
  • Electrostatic dust precipitators
  • Electronic beam welding
  • Lasers
  • Cable test equipment Advantages
  • Simple mounting
  • Improved temperature and power cycling
  • Reduced protection circuits
  • Series and parallel operation ª 1997 IXYS All rights reserved Data according to IEC 747-2 Symbol Test Conditions Ratings IF(RMS) 5A IF(AV)M air self cooling, Tamb = 45°C - without cooling plate 0.8 A - with colling plate 1.0 A forced air cooling: v = 3 m/s, T amb = 35°C - without cooling plate 1.4 A - with cooling plate 1.7 A oil cooling, T amb = 35°C - without cooling plate 2.0 A - with cooling plate 2.0 A P RSM T(vj)= 150°C; t p = 10 µs 1.6 kW IFSM non repetitive, 50 c/s (for 60 c/s add 10%) T(vj)= 45°C; t p = 10 ms 70 A T(vj)= 150°C; t p = 10 ms 60 A Tamb -40...+150 °C Tstg -40...+150 °C T(vj) 150 °C Weight 127 g Symbol Test Conditions Characteristic Values IR T(vj) = 150°C; V R = VRRM ≤ 1 mA VF IF =3 A 1 8 V T(vj) = 25°C VTO T(vj) = 150°C 12 V rT T(vj) = 150°C 1.8 m Ω a f = 50Hz 5 x 9,81 m/s 2 M d 8N m High Voltage Rectifiers V RRM = 24000 V Hochspannungsgleichrichter V dT = 4000 V IF(AV)M = 2.0 A VRRM VV(RMS) VdT Standard Power Designation V V V Types 24000 9000 4000 UGE 1112 AY4 Si-E 9000 / 4000-0.7 UGE 3126 AY4 Data according to IEC 747-2

11IXYS reserve the right to change limits, test conditions and dimensions. Fig. 1: Forward characteristics Instantaneous forward current IF as a function of instantaneous forward voltage drop VF for junction temperature T(vj) = 25°C and T(vj) = 150°C a = Mean value characteristic b = Limit value characteristic Fig. 2: Characteristics of maximum permissible current The curves show the non repetitive peak one cycle surge forward current I FSM as a function of time t and serve for rating protective devices. a = Initial state T (vj) = 45°C b = Initial state T(vj) = 150°C Fig. 3: Power loss Non repetitive peak reverse power loss PRSM as a function of time t, T(vj) = 150°C Fig. 4: Load diagramm Mean forward current IF(AV) of one module for a sine half wave for various cooling modes as a function of the cooling medium temperature Tamb for a resistive load (horizontal mounting). Cooling modes 1 = air self cooling without cooling plate 2 = air self cooling with cooling plate 3 = forced air cooling without cooling plate 4 = forced air coolingwith cooling plate 5 = oil cooling w ithout cooling plate 6 = oil cooling with cooling plate 0 30 60 90 120 150 TA A IF(AV) 10-3 10-2 10-1 100 101 100 s t A IFSM 0 2 4 6 8 10 12 14 16 18 20 22 24 V VF A IF 10-6 10-5 10-4 10-3 10-2 10-1 100 101 102 103 104 s t W PRSM T(vj) = 150°C T(vj) = 25°C a b b a 180° IFAV UGE 3126 AY4

12 ª 1997 IXYS All rights reserved 1. General remarks The high-voltage retifier modules of the UGE series function as single-leg half-wave rectifiers (abbreviation = E). They are used for high-voltage DC supply, e.g. in – high frequency generators – X-ray equipment – dust precipitators. The construction of the module plastic case with screw connection simplifies mechanical arrangement of the desired rectifier circuit. The user's individual input voltage and current requirements can be satisfied by selection of the appropriate modules, by mounting with or without a cooling plate or by series connection of modules. 2. Design

2.1 Electrical

High-voltage rectifier modules consist of an internally integrated series connection of avalanche diodes. Electric terminals of the module screw connection: Anode (A) = Threaded hole Cathode (K) = Threaded bolt

2.2 Mechanical

(for dimensions see dimension diagram) The avalanche diodes are embedded in an epoxy resin pot with axial metal terminals. The materials used guarantee good insulation and resistance to corrosion. 3. Technical data The operating reliability of high-voltage rectifier modules is mainly influenced by the safety margin between the specified limit values and the operating data. Table on page 3 gives rated voltage values - recommended voltages with a frequency of 40 to 60 Hz and a maximum voltage variation of 10% - for the single leg circuit configuration. When other rectifier circuits are arranged with these modules V dT becomes: – bridge circuit, B VdT = 0,9 x VV(RMS) – three phase bridge circuit, DB VdT = 1,35 = VV(RMS) 1. Allgemeines Die Hochspannungsgleichrichter-Module der Serie UGE sind in ihrer elektrischen Funktion Einweggleichrichter in Einzweig- schaltung (Kurzbezeichnung = E). Sie werden zur Hoch- spannungs-Gleichstromversorgung eingesetzt, z.B. in – Hochfrequenz-Generatoren – Röntgenanlagen – elektrostatischen Staubfilteranlagen. Die Modulkonstruktion - Kunststoffgehäuse mit Schraub- verbindung - ermöglicht einen einfachen mechanischen Auf- bau der gewünschten Gleichrichterschaltung. Anwendungsspezifische Anschlußspannungen und Ströme können durch Auswahl der geeigneten Bausteine, Montage ohne und mit Kühlblech bei verschiedenen Kühlarten oder durch Serienschaltung verwirklicht werden. 2. Aufbau

2.1 Elektrisch

Hochspannungsgleichrichter-Module bestehen aus einer in- tegrierten Reihenschaltung von Avalanche-Dioden. Elektrische Anschlüsse der Modul-Schraubverbindung: Anode (A) = Gewindebohrung Kathode (K) = Gewindebolzen.

2.2 Mechanisch

(Abmessungen siehe Maßbild) In einem Epoxydharzbecher mit axial angeordneten Metallan- schlüssen sind die Avalanche-Dioden in Gießharz eingebettet. Die verwendeten Materialien garantieren eine gute Isolations- fähigkeit und Korrosionsbeständigkeit. 3. Technische Daten Die Betriebszuverlässigkeit von Hochspannungsgleichrichter- Modulen wird wesentlich durch den Sicherheitsabstand zwi- schen den angegebenen Grenzwerten und den Einsatzdaten beeinflußt. Für die spannungsmäßige Beanspruchung in Ein- zweigschaltung sind in der Tabelle Seite 3 Nennwerte - das sind empfohlene Betriebsdaten, die für sinusförmige Ver- sorgungsspannung von 40 bis 60 Hz und maximal 10% Spannungsschwankung gelten - angegeben. Bei Aufbau von anderen Gleichrichterschaltungen mit diesen Modulen ergibt sich V dT entsprechen: – Brückenschaltung, B VdT = 0,9 x VV(RMS) – Drehstrom-Brückenschaltung, DB VdT = 1,35 = VV(RMS)

13IXYS reserve the right to change limits, test conditions and dimensions. 100 The current reduction factors apply for air self cooling and horizontal mounting (with respect to module axis). Die Stromreduzierungsfaktoren gelten bei Luftselbstkühlung nur für waagrechte Ein- baulage (bezogen auf Modulachse). Table 2: Current reduction factor Sn Tabelle 2:Stromreduzierungsfaktor Sn 8.4 5.4 120 4. Current reduction for series connections When several modules are connected in series (screwed to one another), the allowed mean forward current I FAV should be reduced as a function of the number of modules and cooling mode used. Cooling modes 1 = Convection cooling without cooling plate 2 = Convection cooling with cooling plate 3 = Forced air cooling without cooling plate 4 = Forced air cooling with cooling plate 5= Oil cooling without cooling plate 6 = Oil cooling with cooling plate 4. Stromreduktion bei Reihenschaltung Bei Serienschaltung (Aneinanderschrauben) mehrerer Modu- le ist der zulässige Dauergrenzstrom IFAV in Abhängigkeit von der Anzahl der Module und Kühlart zu reduzieren. Definition der Kühlarten 1 = Luftselbstkühlung ohne Kühlblech 2 = Luftselbstkühlung mit Kühlblech 3 = Verstärkte Luftkühlung ohne Kühlblech 4 = Verstärkte Luftkühlung mit Kühlblech 5 = Ölkühlung ohne Kühlblech 6 = Ölkühlung mit Kühlblech 3 mm thick aluminium plate, chamfer all edges. Aluminium-Blech, 3 mm dick, alle Kanten brechen. no further reduction keine weitere Reduktion Cooling mode Number of modules Kühlart Anzahl Module 2 3 4 5 6 Sn 1 0,75 0,65 0,6 0,55 0,5 2 0,85 0,8 0,78 0,75 3 0,85 0,8 0,78 0,77 4 0,95 0,92 0,9 0,88 5 0,92 0,88 0,86 6 0,96 0,94

14 ª 1997 IXYS All rights reserved Insulation class Isolationsgruppe A B C Construction without with without with without with Cooling plate Cooling plate Cooling plate Aufbauart ohne mit ohne mit ohne mit Kühlblech Kühlblech Kühlblech Allowed supply voltage based creepage distance [V] [V] [V] [V] [V] [V] Zulässige Anschlußspannung 9000 7600 6900 4900 5000 3400 aufgrund des Kriechwegs Table 3 Tabelle 3 not included in scope of delivery gehört nicht zum Lieferumfang Spring washer B 8 DIN 137 A 2 g Federscheibe B 8 DIN 137 A 2 g Washer A 8,5 ∅ DIN 125 – ST -A4G Scheibe A 8,5 ∅ DIN 125 – ST -A4G Apply thermal grease DC 340 here when mounting with cooling plates Bei Montage mit Kühlblechen hier Wärmeleitpaste DC 340 auftragen M Fig. 7: Mounting of modules Bild 7: Montage der Module Torque M = 800 Ncm Drehmoment M = 800 Ncm 5. Mounting instructions

5.1 Mounting of modules

without cooling plate (Fig. 7): 5. Montagehinweise

5.1 Darstellung der Montage:

Montage ohne Kühlblech (Bild 7)

5.2 Mounting of modules

with cooling plate: as shown in Fig. 7, however, the cooling plate ist mounted with thermal grease instead of with washer A 8.5 ∅ DIN 125. To satisfy VDE specification 0110, voltage limits are prescribed - depending on the creepage distance of the pot shape (61 mm for mounting without cooling plate, 42 mm for mounting with cooling plate). In case of air cooling care should be taken that the proper class of insulation is chosen for the respective supply voltage (see table 3).

5.2 Montage:

Module mit Kühlblech wie in Bild 7 skizziert, jedoch anstelle der Scheibe A 8,5 ∅ DIN 125 wird das Kühlblech mit Wärmeleitpaste eingesetzt. Zur Einhaltung der VDE-Vorschrift 0110 sind - bedingt durch den Kriechweg der Bechergeometrie (61 mm bei Montage ohne Kühlblech, 42 mm bei Montage mit Kühlblech) - Spannungs- grenzen vorgeschrieben. Zu beachten ist bei Betrieb in Luft, daß sich die zulässige Anschlußspannung nach der vorgese- henen Isolationsgruppe richtet (siehe Tabelle 3).

5.3 Distance to adjacent parts

The distance to adjacent g metal parts should be at least 25 mm. This also applies to mounting with cooling plates (see Fig. 8). A protective circuit in accordance with Table 4 should be provided in order to prevent unpermissible capacitive earth currents from flowing through the first diode. This can be done by arranging the modules in groups for voltages of Vp ~ 30 kV each (see Fig. 9).

5.3 Abstände zur Umgebung

Der Abstand zu umgebenden geerdeten Metall-T eilen sollte minimal 25 mm betragen. Dies gilt auch bei Aufbau mit Kühl- blechen (siehe Bild 8). Zur Vermeidung von unzulässigen kapazitiven Erdströmen über die erste Diode ist eine Schutzbeschaltung nach Tabelle 4 vor- zusehen. Es sind dabei jeweils Modulgruppen für Teilspannun- gen von Vp ~ 30 kV zu bilden (siehe Bild 9).

15IXYS reserve the right to change limits, test conditions and dimensions. Fig. 9: Circuit for protection of modules against capacitive earth currents Bild 9: Schutzbeschaltung der Module gegen kapazitive Erdströme CI (nF) UGE 0421 AY4 5.6 UGE 0221 AY4 2.2 UGE 1112 AY4 0.87 UGE 3126 AY4 0.15 Table 4: Protective circuit capacitances for avoidance of too high capacitive ground currents from 30 kVRMS Tabelle 4: Schutzbeschaltungskapazitäten zur Vermeidung zu großer kapazitiver Erdströme ab 30 kVRMS Fig. 8: Minimum distance for mounting Bild 8: Mindestabstände bei Montage UGE .... C 1 C 1 C 1 ~ 30 kV ~ 30 kV ~ 30 kV UGE ....

Edisonstr. 15, D-68623 Lampertheim Telefon: +49-6206-503-0, Fax: +49-6206-503627 e-mail: custserv@ixys.de IXYS Corporation

3540 Bassett Street, Santa Clara CA 95054

Phone: (408) 982-0700, Fax: 408-496-0670 http://www.ixys.com e-mail: sales@ixys.com Publication D 97008 DE Printed in Germany (09.97 • 2 • DP) Technical advice and further information IXYS International Sales Representatives Germany (Reps) Asia, Australia, Africa North Hubert Schroeter KG Saseler Bogen 1

22393 Hamburg

Phone: 040/6 00 006-0 Fax: 040/6 00 006-30 West Erhard Mannheim KG Industrievertretungen Heidestraße 4

42579 Heiligenhaus

Phone: 02056/9 83 60 Fax: 02056/5 74 37 Southwest Wolfgang Trautmann Reutlinger Str. 4

78054 VS-Schwenningen

Phone: 07720/12 03 Fax: 07720/3 34 42 Germany (Distris) Kluxen GmbH Nordkanal 52

20097 Hamburg 1

Phone: 040/23 70 15 29 Fax: 040/23 03 85 Dietrich Schuricht GmbH & Co. KG Richtweg 32

28195 Bremen

Phone: 0421/36 54 54 Fax: 0421/36 54 291 BETRONIK Handelsgesellschaft für elektronische Bauelemente mbH Grunewaldstr. 39a

12165 Berlin

Phone: 030/79 09 97 - 0 Fax: 030/79 09 97 51 Ingenieurbüro Rainer König Giesendorfer Str. 11 a

12207 Berlin

Phone: 030/76 89 09 16 Fax: 030/76 89 09 30 MSC Vertriebs GmbH Industriestraße 16

76297 Stutensee

Phone: 07249/910-0 Fax: 07249/79 93 Future Electronics Deutschland GmbH Münchner Straße 18

85774 Unterföhring

Phone: 089/95 72 70 Fax: 089/95 72 71 29 Sparepart-Service ABB Industrietechnik AG Geschäftsbereich Service Edisonstr. 15

68623 Lampertheim

Phone: 06206/503 272 Fax: 06206/503 620 IXYS Semiconductor GmbH Edisonstr. 15 Phone: 06206/503 394 Fax: 06206/503 627 Europe Austria ABB Serienprodukte Ges.m.b.H. Abt. SERTQ Wienerbergstraße 11 B P.O. Box 184

1101 Wien

Phone: 01-60 10 9-6153 Fax: 01-60 10 9-8600 Denmark C-88 AS Kokkedal Industripark 101

2980 Kokkedal

Phone: +45-70 10 48 88 Fax: +45-70 10 48 89 Finland Energel Oy Atomitie 1

00370 Helsinki

Phone: 0-586 2066 Fax: 0-586 2046 France Eurocomposant S.A.

144 Avenue Joseph Kessel

78960 Voisins le Bretonneux

Phone: 1-30 64 95 15 Fax: 1-30 43 68 27 Greece Markides Michelis & Co 8, Markris Str., Aegaleo 122 41 Athens Phone: 1-5 98 01 45 Fax: 1-5 90 98 33 Great Britain IXYS Semiconductor GmbH Providence House Forest Road, Binfield Bracknell, Berkshire RG 12 5HP Phone: 01344-48 28 20 Fax: 01344-48 28 10 Great Britain GD Rectifiers Ltd. Victoria Gardens Burgess Hill West Sussex RH159NB Phone: 01444-24 34 52 Fax: 01444-87-07-22 Great Britain Larontrol Ltd. Unit K4 Brookside Avenue Rustington Trading Estate Littlehampton West Sussex BN16 3LF Phone: 01903-77 11 60 Fax: 01903-77 20 73 Great Britain Future Electronics Poyle Road, Colnbrook Berkshire SL3 OEZ Phone: 01753-68 70 00 Fax: 01753-68 91 00 Italy ABB DACOM SpA Viale Edison, 50

20099 Sesto San Giovanni (MI)

Phone: 02-26 232.125 Fax: 02-26 232.144 Australia Braemac PTY. Ltd. 1/59-61 Burrows Road Alexandria NSW 2015 Phone: (02) 9550 6600 Fax: (02) 9550 6370 China KARIN Electronic Supplies Room 1095, Pana Tower

36 Hai Dian Road

Hai Dian District, Beijing Phone: 8610-6262 9049 Fax: 8610-6264 8830 China KARIN Electronic Supplies Room 305, A Section, Yin Hai Bldg., 250 Cao Xi Rd. Shanghai Phone: 8621-6482 3543 Fax: 8632-6482 3542 China KARIN Electronic Supplies Room 1503, Oriental Plaza

39 Janshe Rd, Shenzhen

Phone: 86755-220 9219 Fax: 86755-228 4992 China Sunguard Electronics Ltd. Room 112, No. 12B Zhong Guan Chun Road Hai Dian District, Beijing Phone: 10-264-5210, 10-264-5212 + 10-254-2870 Fax: 10-254-2870 China Sunguard Electronics Ltd. Room 805, 8/F., Sufa Building, Block 306 ZhenHua Road, Shenzhen Phone: 0755-3230 748 (658) 0755-3237 349 Fax: 0755-3237 394 Hongkong KARIN Electronic Supplies Co. Ltd., Div. 8 KARIN Building, 5F 166 Wai Yip St., Kwun Tong Kowloon, Hong Kong Phone: 852-2763 3100 Fax: 852-2343 6479 Hongkong Rêvel Electronics Co. Ltd. Unit 11, 12/Floor, Ricky Centre

36 Chong Yip Street, Kwun Tong

Kowloon, Hong Kong Phone: 23 89-88 91 Fax: 23 89-24 48 Hongkong Sunguard Electronics Ltd. 907-10 Yat Chau, International Plaza

118 Connaught Road West

Phone: (852) 2811 8230 Fax: (852) 2960 1239, 2960 1216 India Chadda Power Semiconductors 501, Savera Apts. Versova Road, Andheri (West) Bombay-400 061 Phone: 022-6 26 06 78 Fax: 022-6 31 63 84 Netherlands ABB Componenten B.V. Lylantse Baan 9

2908 LG Capelle a/d IJssel

Phone: 010-2 58 22 50 Fax: 010-4 58 65 59 Norway Henaco A/S Trondheimsveien 436 Po. box 126, Kalbakken

0902 Oslo 9

Phone: 2-216 21 10 Fax: 2-225 77 80 Sweden Pelcon Electronics AB Girovägen 13 Box 6023

17562 Järfälla

Phone: 8-7 95 98 70 Fax: 8-7 60 76 85 Switzerland ABB Normelec AG Badenerstr. 790

8048 Zürich-Altstetten

Phone: 1-4 35 66 66 Fax: 1-4 35 66 06 Spain ABI Semiconductores Dalia 387 Ch 6

28109 El Soto (Alcobendas)

Phone: 91-6 50 76 51 Fax: 91-6 50 03 49 Spain AQL electrónica, s.a. General Palanca, 26

28045 Madrid

Phone: 91-4 67 75 12 Fax: 91-5 30 29 34 Spain Rectificadores Guasch S.A. Componentes y Electronica de Potencia Alaba, 60-62

08005 Barcelona

Phone: 93-3 09 88 91 Fax: 93-3 00 18 41 Turkey Özdisan Elektronik Pazarlama San. VE TIC. A.S. Bereketzade Mahallesl Galata Kulesi Sokak No: 34/3 Karaköy/Istanbul Phone: 212-243 40 34, 251 29 41 Fax: 212-244 59 43 Israel Gallium Electronics Ltd. 11 Hasadna St. P.O.B. 2552 IL 43650 RA’ANANA Phone: 972 9 74 82 182 Fax: 972 9 74 84 046 Japan Unidux Inc. 5-1-21 Kyonan-cho, Musashino-shi, Tokyo 180 Phone: 0422-32-4500 Fax: 0422-31-2050 Japan Systems Marketing, Inc. Fukui Bldg. 2-2-12 Sotokanda, Chiyoda-Ku Tokyo 101 Phone: 03-32 54 27 51 Fax: 03-32 54 32 88 Japan Trancy INC New Heights Aoyama 203 1-1-10 Shibuya, Shibuya-Ku Tokyo 150 Phone: +81-3-3486-7211 Fax: +81-3-3486-7214 Korea Asea Brown Boveri Ltd. Oksan Bldg. 5-9 Fl. 157, Samsung-Dong, Kangnam-Ku, Seoul 135-090 Phone: 2-52 83 062 Fax: 2-52 83 091 Korea Kisung International Co. Ltd. A-7-121, 604-1 Kuro-Dong, Kuro-Ku, Seoul Phone: 02-679 7348 Fax: 02-675 1404 Korea Daan Electronic Co., Ltd. Daan Bldg, 4F 22-1 Singye-Dong, Yongsan-Ku, Seoul Phone: 02-822-718-8033 Fax: 02-822-718 1160+1161 Singapore Practical Electronics Pte. Ltd.

1 Rochor Canal Rd

# 02-57, Sim Lim Square Singapore 0718 Phone: 3-38 73 88 Fax: 3-38 16 88 South Africa ABB Industry (Pty) Ltd. Drives P.O. Box 11494, Randhart 1457 Phone: 011-8 64 53 40 Fax: 011-9 08 20 61 South Africa Avnet Kopp (Pty) Ltd P. O. Box 3853, Rivonia, 2128 South Africa. Phone: +27 11 444 2333 Fax: +27 11 444 7778 Taiwan Industrade Co., Ltd. 6F, No. 64, Section 2 Chung Cheng Road Shihlin, Taipei, Taiwan 111 Phone: 886-2-836 90 11 Fax: 886-2-835 30 37 Sept. 97