Intel® Server Board S2600WT Technical Product Specification (TPS) Revision 1.9 February 2020 Intel® Server Boards and Systems
Intel® Server Board S2600WT Technical Product Specification ii <Blank Page>
Intel® Server Board S2600WT Technical Product Specification
Revision History
August 2014 1..0 1st External Public Release December 2014 1.01 Changes from previous release: Removed content references to PCIx Riser Card support Added Appendix F – Statement of Volatility July 2015 1.1 Changes from previous release: Chapter 7.1.2. Updated to “Fan speed control with SDR” Chapter 7.3.10. Updated to “Power supply inlet temperature Chapter 7.3.10.2. Updated content references to “Processor DTS-Spec Margin Sensor(s) Chapter 7.3.10.6. Updated content references to “Inlet Temperature Sensor” Chapter 7.3.14.5. Updated “buffer DIMMs” to “DIMMs with teperature sensors” November 2015 1.2 Chapter 6.1. Updated BIOS Setup Utility Security Options Menu Chapter 11.6. BIOS Updated BIOS recovery jumper April 2016 1.3 Updated to include Refresh SKUs. Added TPM (2.0) Added E5-2600 v4 Processor famility support Updated DIMMs support table July 2016 1.4 Table 68: Added Intel® PCI Express 8-Lane, 4-Port Fan-Out Switch card Table 4: Updated Memory supported Table 1: Updated Memory supported Chapter 4.5 added NVDIMM support Chapter 3.5.1 updated Processor cores features Chapter 4.4 Updated Supported Memory Chapter 5.10 Added description os code sopported in serial port B Table 24: Added RMM4Lite2 (RoHS free) Table 61: Updated MRC Progress Codes Chapter 11.6 Added note “iflash –css” feature October 2016 1.5 NVDIMMs population Rules, updated December 2016 1.6 Note added: PSOC of HSBP downgrades or upgradesdepending of the BMC PSOC has. November 2017 1.7 Table 6. DIMM Population Matrix updated November 1.8 Table 6. DIMM Population Matrix updated February 2020 1.9 Added Appendix H – Product Regulatory Information, including EU Lot 9 product collateral efficiency support links
Intel® Server Board S2600WT Technical Product Specification Disclaimers Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, lifesaving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES, SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Intel® Server Board S2600WT may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. This document and the software described in it are furnished under license and may only be used or copied in accordance with the terms of the license. The information in this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or any software that may be provided in association with this document. Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the express written consent of Intel Corporation. Copies of documents which have an order number and are referenced in this document, or other Intel® Literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/Literature.htm. Intel and Xeon are trademarks or registered trademarks of Intel Corporation. *Other brands and names may be claimed as the property of others. Copyright © Intel Corporation. All rights reserved.
Intel® Server Board S2600WT Technical Product Specification Table of Contents
Intel® Server Board S2600WT Technical Product Specification
Intel® Server Board S2600WT Technical Product Specification
Intel® Server Board S2600WT Technical Product Specification
Intel® Server Board S2600WT Technical Product Specification
Intel® Server Board S2600WT Technical Product Specification <This page is intentionally left blank.>
Intel® Server Board S2600WT Technical Product Specification 1. Introduction This Technical Product Specification (TPS) provides board-specific information detailing the features, functionality, and high-level architecture of the Intel® Server Board S2600WT. Design-level information related to specific server board components and subsystems can be obtained by ordering External Product Specifications (EPS) or External Design Specifications (EDS) related to this server generation. EPS and EDS documents are made available under NDA with Intel and must be ordered through your local Intel representative. See the Reference Documents section for a list of available documents.
1.1 Chapter Outline
This document is divided into the following chapters: Chapter 1 – Introduction Chapter 2 – Product Features Overview Chapter 3 – Processor Support Chapter 4 – System Memory Chapter 5 – System I/O Chapter 6 – System Security Chapter 7 – Platform Management Chapter 8 – Intel® Intelligent Power Node Manager (NM) Support Overview Chapter 9 – Basic and Advanced Server Management Features Chapter 10 – On-Board Connector and Header Overview Chapter 11 – Reset and Recovery Jumpers Chapter 12 – Light-Guided Diagnostics Chapter 13 – Power Supply Specification Guidelines Appendix A – Integration and Usage Tips Appendix B – Integrated BMC Sensor Tables Appendix C – Management Engine Generated SEL Event Messages Appendix D – POST Code Diagnostic LED Decoder Appendix E – POST Code Errors Appendix F – Statement of Volatility Appendix G – Supported Intel® Server Systems
1.2 Server Board Use Disclaimer
Intel Corporation server boards support add-in peripherals and contain a number of high-density VAVAGO and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.
- Product Features Overview
- Intel® Ethernet Controller X540, supporting 10 GbE (Intel Server Board Product Code - S2600WTTR)
- Intel® Ethernet Controller I350, supporting 1 GbE (Intel Server Board Product Code – S2600WT2R) All other onboard features will be identical.
Table 1. Intel® Server Board S2600WT Feature Set
- Two LGA2011-3 (Socket R3) processor sockets
- Support for one or two Intel® Xeon® processors E5-2600 v3, v4 product family
- Maximum supported Thermal Design Power (TDP) of up to 145 W Memory
- 24 DIMM slots – 3 DIMMs/Channel – 4 memory channels per processor
- Registered DDR4 (RDIMM), Load Reduced DDR4 (LRDIMM)
- Memory data transfer rates Intel® Xeon® processors E5-2600 v3: o DDR4 RDIMM: 1600 MT/s (3DPC), 1866 MT/s (2DPC), 2133 MT/s (2DPC) and 2400 MT/s (1DPC) o DDR4 LRDIMM: 1866 Mt/s (3DPC), 2400 MT/s (2DPC) o DDR4 LRDIMM3DS: 1866 Mt/s (3DPC), 2400 MT/s (2DPC) o NVDIMM: 2133 Mt/s (1DPC)
- Memory data transfer rates Intel® Xeon® processors E5-2600 v4: o DDR4 RDIMM: 1600 MT/s (3DPC), 2133 MT/s (2DPC) and 2400 MT/s (1DPC) o DDR4 LRDIMM: 1866 Mt/s (3DPC), 2400 MT/s (1DPC/2DPC) o DDR4 LRDIMM3DS: 1866 Mt/s (3DPC), 2400 MT/s (1DPC/2DPC) o NVDIMM: 2133 Mt/s (1DPC)
- DDR4 standard I/O voltage of 1.2V Chipset Intel® C612 chipset External (Back Panel) I/O connections
- DB-15 Video connector
- RJ-45 Serial Port A connector
- Dual RJ-45 Network Interface connectors supporting either : o 10 GbE RJ-45 connectors (Intel Server Board Product Code – S2600WTTR) or o 1 GbE RJ-45 connectors (Intel Server Board Product Code – S2600WT2R)
- Dedicated RJ-45 server management port
- Three USB 2.0 / 3.0 ports Internal I/O connectors/headers
- One Type-A USB 2.0 connector
- One 2x5 pin connector providing front panel support for two USB 2.0 ports
- One 2x10 pin connector providing front panel support for two USB 2.0 / 3.0 ports
- One 2x15 pin SSI-EEB compliant Standard Front Panel header
- One 2x15 high density Storage Front Panel connector
- One 2x7pin Front Panel Video connector
- One 1x7pin header for optional Intel® Local Control Panel support
- One DH-10 Serial Port B connector
Intel® Server Board S2600WT Technical Product Specification Feature Description PCIe* Support • PCIe* 3.0 (2.5, 5, 8 GT/s) – backwards compatible with PCIe* Gen 1 and Gen 2 devices 1U Server – Riser Card Support
- Server board includes two PCIe* 3.0 compatible riser card only slots o Riser #1 – PCIe* 3.0 x24 – 1 PCIe* Full Height / Half Length add-in card support in 1U o Riser #2 – PCIe* 3.0 x24 – 1 PCIe* Full Height / Half Length add-in card support in 1U 2U Server – Riser Card Support
- Server board includes three PCIe* 3.0 compatible riser card only slots: o Riser #1 – PCIe* 3.0 x24 – up to 3 PCIe* slots in 2U o Riser #2 – PCIe* 3.0 x24 – up to 3 PCIe* slots in 2U o Riser #3 – PCIe* 3.0 x8 + DMI x4 (PCIe* 2.0 compatible) – up to 2 PCIe* slots in 2U
- With three riser cards installed, up to 8 possible add-in cards can be supported: o 4 Full Height / Full Length + 2 Full Height / Half Length add-in cards via Risers #1 and #2 o 2 low profile add-in cards via Riser #3 Available I/O Module Options The server board includes a proprietary on-board connector allowing for the installation of a variety of available I/O modules. An installed I/O module can be supported in addition to standard on-board features and add-in PCIe* cards.
- AXX4P1GBPWLIOM – Quad port RJ45 1 GbE based on Intel® Ethernet Controller I350
- AXX10GBTWLIOM3 – Dual port RJ-45 10GBase-T I/O Module based on Intel® Ethernet Controller x540
- AXX10GBNIAIOM – Dual port SFP+ 10 GbE module based on Intel® 82599 10 GbE controller
- AXX1FDRIBIOM – Single port QSFP FDR 56 GT/S speed InfiniBand* module
- AXX2FDRIBIOM – Dual port QSFP FDR 56 GT/S speed infiniband* module
- AXX1P40FRTIOM – Single port QSFP+ 40 GbE module
- AXX2P40FRTIOM – Dual port QSFP+ 40 GbE module System Fan Support
- Six system fans supported in two different connector formats: hot swap (2U) and cabled (1U) o Six 10-pin managed system fan headers (Sys_Fan 1-6) – Used for 1U system configuration o Six 6-pin hot swap capable managed system fan connectors (Sys_Fan 1-6) – Used for 2U system configuration Video
- Integrated 2D Video Controller
- 16 MB DDR3 Memory On-board storage controllers and options
- 10x SATA 6Gbps ports (6Gb/s, 3 Gb/s and 1.5Gb/s transfer rates are supported) o Two 7-pin single port SATA connectors capable of supporting up to 6 Gb/sec o Two 4-port mini-SAS HD (SFF-8643) connectors capable of supporting up to 6 Gb/sec SATA
- One eUSB 2x5 pin connector to support 2mm low-profile eUSB solid state devices
- Optional SAS IOC/ROC support via on-board Intel® Integrated RAID module connector
- Embedded Software SATA RAID o Intel® Rapid Storage RAID Technology (RSTe) 4.1 o Intel® Embedded Server RAID Technology 2 (ESRT2) 1.41 with optional RAID 5 key support Security • Intel® Trusted Platform Module (TPM) - AXXTPME5 (1.2), AXXTPME6 (v2.0) and AXXTPME7 (v2.0) (Accessory Option) Server Management
- Integrated Baseboard Management Controller, IPMI 2.0 compliant
- Support for Intel® Server Management Software
- On-board RJ45 management interface
- Intel® Remote Management Module 4 Lite support (Accessory Option)
2.1 Server Board Component/Feature Identification
Figure 1. Server Board Component/Features Identification
Figure 4. Intel® Light Guided Diagnostic LED Identification
Figure 5. Jumper Block Identification See Chapter 11 - Reset & Recovery Jumpers for additional details.
2.2 Product Architecture Overview
Controllers I350 1 GbE or X540 10 GbE, and the Emulex* Pilot-III Baseboard Management Controller. interconnects of each of the major sub-system components. Figure 6. Intel® Server Board S2600WT Architectural Block Diagram
1 GbE or
1 GbE
6 Gbps
Intel® Server Board S2600WT Technical Product Specification
2.3 System Software Overview
The server board includes an embedded software stack to enable, configure, and support various system functions. This software stack includes the System BIOS, Baseboard Management Controller (BMC) Firmware, Management Engine (ME) Firmware, and management support data including Field Replaceable Unit (FRU) data, and Sensor Data Record (SDR) data. The system software is pre-programmed on the server board during factory assembly, making the server board functional at first power on after system integration. Typically, as part of the initial system integration process, FRU and SDR data will have to be installed onto the server board by the system integrator to ensure the embedded platform management subsystem is able to provide best performance and cooling for the final system configuration. It is also not uncommon for the system software stack to be updated to later revisions to ensure the most reliable system operation. Intel makes periodic system software updates available for download at the following Intel website: http://downloadcenter.intel.com System updates can be performed in a number of operating environments, including the uEFI Shell using the uEFI only System Update Package (SUP), or under different operating systems using the Intel® One Boot Flash Update Utility (OFU). Reference the following Intel documents for more in-depth information about the system software stack and their functions: Intel® Server System BIOS External Product Specification for Intel® Servers Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family Intel® Server System BMC Firmware External Product Specification for Intel® Servers Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family
2.3.1 System BIOS
The system BIOS is implemented as firmware that resides in flash memory on the server board. The BIOS provides hardware-specific initialization algorithms and standard compatible basic input/output services, and standard Intel® Server Board features. The flash memory also contains firmware for certain embedded devices. This BIOS implementation is based on the Extensible Firmware Interface (EFI), according to the Intel® Platform Innovation Framework for EFI architecture, as embodied in the industry standards for Unified Extensible Firmware Interface (UEFI). The implementation is compliant with all Intel® Platform Innovation Framework for EFI architecture specifications, as further specified in the Unified Extensible Firmware Interface Reference Specification, Version 2.3.1. In the UEFI BIOS design, there are three primary components: the BIOS itself, the Human Interface Infrastructure (HII) that supports communication between the BIOS and external programs, and the Shell which provides a limited OS-type command-line interface. This BIOS system implementation complies with HII Version 2.3.1, and includes a Shell.
2.3.1.1 BIOS Revision Identification
The BIOS Identification string is used to uniquely identify the revision of the BIOS being used on the server. The BIOS ID string is displayed on the Power-On Self -Test (POST) Diagnostic Screen and in the <F2> BIOS Setup Main Screen, as well as in System Management BIOS (SMBIOS) structures.
Intel® Server Board S2600WT Technical Product Specification The BIOS ID string for S2600 series server boards is formatted as follows: Where:
- BoardFamilyID = String name to identify board family. “SE5C610” is used to identify BIOS builds for Intel® S2600 series Server Boards, based on the Intel® Xeon® Processor E5-2600 v3, v4 product families and the Intel® C612 chipset.
- OEMID = Three-character OEM BIOS Identifier, to identify the board BIOS “owner”. “86B” is used for Intel PCSD Commercial BIOS Releases.
- MajorVer = Major Version, two decimal digits 01-99 which are changed only to identify major hardware or functionality changes that affect BIOS compatibility between boards. “01” is the starting BIOS Major Version for all platforms.
- MinorVer = Minor Version, two decimal digits 00-99 which are changed to identify less significant hardware or functionality changes which do not necessarily cause incompatibilities but do display differences in behavior or in support of specific functions for the board.
- RelNum = Release Number, four decimal digits which are changed to identify distinct BIOS Releases. BIOS Releases are collections of fixes and/or changes in functionality, built together into a BIOS Update to be applied to a Server Board. However, there are “Full Releases” which may introduce many new fixes/functions, and there are “Point Releases” which may be built to address very specific fixes to a Full Release. The Release Numbers for Full Releases increase by 1 for each release. For Point Releases, the first digit of the Full Release number on which the Point Release is based is increased by 1. That digit is always 0 (zero) for a Full Release.
- BuildDateTime = Build timestamp – date and time in MMDDYYYYHHMM format: MM = Two-digit month. DD = Two-digit day of month. YYYY = Four-digit year. HH = Two-digit hour using 24-hour clock. MM = Two-digit minute. An example of a valid BIOS ID String is as follows: The BIOS ID string is displayed on the POST diagnostic screen for BIOS Major Version 01, Minor Version 01, Full Release 0003 that is generated on August 13, 2011 at 8:56 AM. The BIOS version in the <F2> BIOS Setup Utility Main Screen is displayed without the time/date timestamp, which is displayed separately as “Build Date”: SE5C610.86B.01.01.0003
2.3.1.2 Hot Keys Supported During POST
Certain “Hot Keys” are recognized during POST. A Hot Key is a key or key combination that is recognized as an unprompted command input, that is, the operator is not prompted to press the Hot Key and typically the Hot Key will be recognized even while other processing is in progress.
responsibility of the OS and the OS defines its own set of recognized Hot Keys. The following table provides a list of available POST Hot Keys along with a description for each. Table 2. POST Hot-Keys
2.3.1.3 POST Logo/Diagnostic Screen
Screen will be displayed, overriding the default Intel Logo Screen. which transfers data in a mode that is not graphics-compatible.
2.3.1.4 BIOS Boot Pop-Up Menu
devices from which the system can be booted, and allows a manual selection of the desired boot device. password allows only booting in the order previously defined by the Administrator.
2.3.1.5 Entering BIOS Setup
boot time when the OEM or Intel Logo Screen or the POST Diagnostic Screen is displayed.
Intel® Server Board S2600WT Technical Product Specification Note: With a USB keyboard, it is important to wait until the BIOS “discovers” the keyboard and beeps – until the USB Controller has been initialized and the USB keyboard activated, key presses will not be read by the system. When the Setup Utility is entered, the Main screen is displayed initially. However, in the event a serious error occurs during POST, the system will enter the BIOS Setup Utility and display the Error Manager screen instead of the Main screen. Reference the following Intel document for additional BIOS Setup information: Intel® Server System BIOS Setup Guide for Intel® Servers Systems supporting the Intel® Xeon® processor E5-
2600 V3, v4 product family
2.3.1.6 BIOS Update Capability
In order to bring BIOS fixes or new features into the system, it will be necessary to replace the current installed BIOS image with an updated one. The BIOS image can be updated using a standalone IFLASH32 utility in the uEFI shell, or can be done using the OFU utility program under a supported operating system. Full BIOS update instructions are provided when update packages are downloaded from the Intel web site.
2.3.1.7 BIOS Recovery
If a system is completely unable to boot successfully to an OS, hangs during POST, or even hangs and fails to start executing POST, it may be necessary to perform a BIOS Recovery procedure, which can replace a defective copy of the Primary BIOS. The BIOS provides three mechanisms to start the BIOS recovery process, which is called Recovery Mode:
- Recovery Mode Jumper – this jumper causes the BIOS to boot in Recovery Mode
- The Boot Block detects partial BIOS update and automatically boots in Recovery Mode
- The BMC asserts Recovery Mode GPIO in case of partial BIOS update and FRB2 time-out The BIOS Recovery takes place without any external media or Mass Storage device as it utilizes a Backup BIOS image inside the BIOS flash in Recovery Mode. The Recovery procedure is included here for general reference. However, if in conflict, the instructions in the BIOS Release Notes are the definitive version. When the BIOS Recovery Jumper is set (See Figure 5. Jumper Block Identification), the BIOS begins by logging a ‘Recovery Start’ event to the System Event Log (SEL). It then loads and boots with a Backup BIOS image residing in the BIOS flash device. This process takes place before any video or console is available. The system boots to the embedded uEFI shell, and a ‘Recovery Complete’ event is logged to the SEL. From the uEFI Shell, the BIOS can then be updated using a standard BIOS update procedure, defined in Update Instructions provided with the system update package downloaded from the Intel web site. Once the update has completed, the recovery jumper is switched back to its default position and the system is power cycled. If the BIOS detects a partial BIOS update or the BMC asserts Recovery Mode GPIO, the BIOS will boot up with Recovery Mode. The difference is that the BIOS boots up to the Error Manager Page in the BIOS Setup utility. In the BIOS Setup utility, boot device, Shell or Linux for example, could be selected to perform the BIOS update procedure under Shell or OS environment.
2.3.2 Field Replaceable Unit (FRU) and Sensor Data Record (SDR) Data
As part of the initial system integration process, the server board/system must have the proper FRU and SDR data loaded. This ensures that the embedded platform management system is able to monitor the appropriate sensor data and operate the system with best cooling and performance. The BMC supports automatic configuration of the manageability subsystem after changes have been made to the system’s hardware configuration. Once the system integrator has performed an initial SDR/CFG package update,
Intel® Server Board S2600WT Technical Product Specification subsequent auto-configuration occurs without the need to perform additional SDR updates or provide other user input to the system when any of the following components are added or removed.
- Processors
- I/O Modules (dedicated slot modules)
- Storage modules, such as a SAS module (dedicated slot modules)
- Power supplies
- Fans
- Fan options (e.g. upgrade from non-redundant cooling to redundant cooling)
- Intel® Xeon Phi™ co-processor cards
- Hot Swap Backplane
- Front Panel NOTE: The system may not operate with best performance or best/appropriate cooling if the proper FRU and SDR data is not installed.
2.3.2.1 Loading FRU and SDR Data
The FRU and SDR data can be updated using a standalone FRUSDR utility in the uEFI shell, or can be done using the OFU utility program under a supported operating system. Full FRU and SDR update instructions are provided with the appropriate system update package (SUP) or OFU utility which can be downloaded from the Intel web site.
2.3.3 Baseboard Management Controller (BMC) & Management Engine (ME) Firmware
See Chapters 7, 8, and 9 for features and functions associated with the BMC firmware and ME firmware.
Supported Thermal Design Power (TDP) of up to 145W. Visit http://www.intel.com/support for a complete list of supported processors.
3.1 Processor Socket Assembly
Figure 7. Processor Socket Assembly Figure 8. LGA2011-3 ILM (Narrow)
Intel® Server Board S2600WT Technical Product Specification
3.2 Processor Thermal Design Power (TDP) Support
To allow optimal operation and long-term reliability of Intel processor-based systems, the processor must remain within the defined minimum and maximum case temperature (TCASE) specifications. Thermal solutions not designed to provide sufficient thermal capability may affect the long-term reliability of the processor and system. The server board described in this document is designed to support the Intel® Xeon® Processor E5- 2600 v3, v4 product family TDP guidelines up to and including 145W. Disclaimer Note: Intel Corporation server boards contain a number of high-density VAVAGO and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.
3.3 Processor Population Rules
Note: The server board may support dual-processor configurations consisting of different processors that meet the defined criteria below, however, Intel does not perform validation testing of this configuration. In addition, Intel does not guarantee that a server system configured with unmatched processors will operate reliably. The system BIOS will attempt to operate with processors which are not matched but are generally compatible. For optimal system performance in dual-processor configurations, Intel recommends that identical processors be installed. When using a single processor configuration, the processor must be installed into the processor socket labeled “CPU_1”. Note: Some board features may not be functional without having a second processor installed. See Figure 6. Intel® Server Board S2600WT Architectural Block Diagram. When two processors are installed, the following population rules apply: Both processors must be of the same processor family Both processors must have the same number of cores Both processors must have the same cache sizes for all levels of processor cache memory Processors with different core frequencies can be mixed in a system, given the prior rules are met. If this condition is detected, all processor core frequencies are set to the lowest common denominator (highest common speed) and an error is reported. Processors which have different Intel® Quickpath (QPI) Link Frequencies may operate together if they are otherwise compatible and if a common link frequency can be selected. The common link frequency would be the highest link frequency that all installed processors can achieve. Processor stepping within a common processor family can be mixed as long as it is listed in the processor specification updates published by Intel Corporation. Mixing of steppings is only validated and supported between processors that are plus or minus one stepping from each other.
3.4 Processor Initialization Error Summary
and an error is logged to the System Event Log (SEL) with the POST Error Code. failure condition has occurred. to SEL. Operator intervention is required to continue booting the system. the system will continue to boot. Table 3. Mixed Processor Configurations Error Summary Halts with 3 long beeps and 1 short beep. Logs the POST Error Code into the System Event Log (SEL). Alerts the BMC to set the System Status LED to steady Amber. Halts with 3 long beeps and 1 short beep.
Intel® Server Board S2600WT Technical Product Specification Error Severity System Action Processor cache or home agent not identical Fatal The BIOS detects the error condition and responds as follows: Halts at POST Code 0xE5. Halts with 3 long beeps and 1 short beep. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor frequency (speed) not identical Fatal The BIOS detects the processor frequency difference, and responds as follows: Adjusts all processor frequencies to the highest common frequency. No error is generated – this is not an error condition. Continues to boot the system successfully. If the frequencies for all processors cannot be adjusted to be the same, then this is an error, and the BIOS responds as follows: Logs the POST Error Code into the SEL. Alerts the BMC to set the System Status LED to steady Amber. Does not disable the processor. Displays “0197: Processor speeds unable to synchronize” message in the Error Manager. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor Intel® QuickPath Interconnect link frequencies not identical Fatal The BIOS detects the QPI link frequencies and responds as follows: Adjusts all QPI interconnect link frequencies to highest common frequency. No error is generated – this is not an error condition. Continues to boot the system successfully. If the link frequencies for all QPI links cannot be adjusted to be the same, then this is an error, and the BIOS responds as follows: Logs the POST Error Code into the SEL. Alerts the BMC to set the System Status LED to steady Amber. Does not disable the processor. Displays “0195: Processor Intel(R) QPI link frequencies unable to synchronize” message in the Error Manager. Takes Fatal Error action (see above) and will not boot until the fault condition is remedied. Processor microcode update failed Major The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the SEL. Displays “816x: Processor 0x unable to apply microcode update” message in the Error Manager or on the screen. Takes Major Error action. The system may continue to boot in a degraded state, depending on the setting of POST Error Pause in Setup, or may halt with the POST Error Code in the Error Manager waiting for operator intervention. Processor microcode update missing Minor The BIOS detects the error condition and responds as follows: Logs the POST Error Code into the SEL. Displays “818x: Processor 0x microcode update not found” message in the Error Manager or on the screen. The system continues to boot in a degraded state, regardless of the setting of POST Error Pause in the Setup.
Intel® Server Board S2600WT Technical Product Specification
3.5 Processor Function Overview
The Intel® Xeon® processor E5-2600 v3, v4 product family combines several key system components into a single processor package, including the CPU cores, Integrated Memory Controller (IMC), and Integrated IO Module (IIO). In addition, each processor package includes two Intel® QuickPath Interconnect point-to-point links capable of up to 9.6 GT/s, up to 40 lanes of PCI express 3.0 links capable of 8.0 GT/s, and 4 lanes of DMI2/PCI express 2.0 interface with a peak transfer rate of 4.0 GT/s. The processor supports up to 46 bits of physical address space and 48 bits of virtual address space. The following sections will provide an overview of the key processor features and functions that help to define the architecture, performance, and supported functionality of the server board. Available features may vary between different processor models.
3.5.1 Processor Core Features:
Up to 18 execution cores (Intel® Xeon® processor E5-2600 v3 product family) and Up to 22 execution cores (Intel® Xeon® processor E5-2600 v4 product family) When enabled, each core can support two threads (Intel® Hyper-Threading Technology) 46-bit physical addressing and 48-bit virtual addressing 1 GB large page support for server applications A 32 KB instruction and 32 KB data first-level cache (L1) for each core A 256 KB shared instruction/data mid-level (L2) cache for each core Intel® Xeon® processor E5-2600 v3 Up to 2.5 MB per core instruction/data last level cache (LLC)
3.5.2 Supported Technologies:
Intel® Virtualization Technology (Intel® VT) for Intel® 64 and IA-32 Intel® Architecture (Intel® VT-x) Intel® Virtualization Technology for Directed I/O (Intel® VT-d) Intel® Trusted Execution Technology for servers (Intel® TXT) Execute Disable Advanced Encryption Standard (AES) Intel® Hyper-Threading Technology Intel® Turbo Boost Technology Enhanced Intel® Speed Step Technology Intel® Advanced Vector Extensions 2 (Intel® AVX2) Intel® Node Manager 3.0 Intel® Secure Key Intel® OS Guard Intel® Quick Data Technology Trusted Platform Module (TPM) 1.2, 2.0
3.5.2.1 Intel® Virtualization Technology (Intel® VT) for Intel® 64 and IA-32 Intel® Architecture (Intel®
VT-x) Hardware support in the core, to improve performance and robustness for virtualization. Intel VT-x specifications and functional descriptions are included in the Intel® 64 and IA-32 Architectures Software Developer’s Manual.
Intel® Server Board S2600WT Technical Product Specification
3.5.2.2 Intel® Virtualization Technology for Directed I/O (Intel® VT-d)
Hardware support in the core and uncore implementations to support and improve I/O virtualization performance and robustness.
3.5.2.3 Intel® Trusted Execution Technology for servers (Intel® TXT)
Intel TXT defines platform-level enhancements that provide the building blocks for creating trusted platforms. The Intel TXT platform helps to provide the authenticity of the controlling environment such that those wishing to rely on the platform can make an appropriate trust decision. The Intel TXT platform determines the identity of the controlling environment by accurately measuring and verifying the controlling software.
3.5.2.4 Execute Disable Bit
Intel's Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system. This allows the processor to classify areas in memory by where application code can execute and where it cannot. When malicious code attempts to insert code in the buffer, the processor disables code execution, preventing damage and further propagation.
3.5.2.5 Advanced Encryption Standard (AES)
These instructions enable fast and secure data encryption and decryption, using the Advanced Encryption Standard (AES)
3.5.2.6 Intel
® Hyper-Threading Technology The processor supports Intel® Hyper-Threading Technology (Intel® HT Technology), which allows an execution core to function as two logical processors. While some execution resources such as caches, execution units, and buses are shared, each logical processor has its own architectural state with its own set of general-purpose registers and control registers. This feature must be enabled via the BIOS and requires operating system support.
3.5.2.7 Intel® Turbo Boost Technology
Intel® Turbo Boost Technology is a feature that allows the processor to opportunistically and automatically run faster than its rated operating frequency if it is operating below power, temperature, and current limits. The result is increased performance in multi-threaded and single threaded workloads. It should be enabled in the BIOS for the processor to operate with maximum performance.
3.5.2.8 Enhanced Intel® SpeedStep Technology
The processor supports Enhanced Intel SpeedStep Technology (EIST) as an advanced means of enabling very high performance while also meeting the power conservation needs of the platform. Enhanced Intel SpeedStep Technology builds upon that architecture using design strategies that include the following: Separation between Voltage and Frequency changes. By stepping voltage up and down in small increments separately from frequency changes, the processor is able to reduce periods of system unavailability (which occur during frequency change). Thus, the system is able to transition between voltage and frequency states more often, providing improved power/performance balance. Clock Partitioning and Recovery. The bus clock continues running during state transition, even when the core clock and Phase-Locked Loop are stopped, which allows logic to remain active. The core clock is also able to restart more quickly under Enhanced Intel SpeedStep Technology.
Intel® Server Board S2600WT Technical Product Specification
3.5.2.9 Intel® Advanced Vector Extensions 2 (Intel® AVX2)
Intel® Advanced Vector Extensions 2.0 (Intel® AVX2) is the latest expansion of the Intel instruction set. Intel® AVX2 extends the Intel® Advanced Vector Extensions (Intel® AVX) with 256-bit integer instructions, floating- point fused multiply add (FMA) instructions and gather operations. The 256-bit integer vectors benefit math, codec, image and digital signal processing software. FMA improves performance in face detection, professional imaging, and high performance computing. Gather operations increase vectorization opportunities for many applications. In addition to the vector extensions, this generation of Intel processors adds new bit manipulation instructions useful in compression, encryption, and general purpose software. 3.5.2.10 Intel® Node Manager 3.0 Intel® Node Manager 3.0 enables the PTAS-CUPS (Power Thermal Aware Scheduling - Compute Usage per Second) feature of the Intel Server Platform Services 3.0 Intel ME FW. This is a grouping of separate platform functionalities that provide Power, Thermal, and Utilization data that together offer an accurate, real time characterization of server workload. These functionalities include the following: Computation of Volumetric Airflow New synthesized Outlet Temperature sensor CPU, memory, and I/O utilization data (CUPS). This PTAS-CUPS data can then be used in conjunction with the Intel® Server Platform Services 3.0 Intel® Node Manager power monitoring/controls and a remote management application (such as the Intel® Data Center Manager [Intel® DCM]) to create a dynamic, automated, closed-loop data center management and monitoring system.
3.5.2.11 Intel® Secure Key
The Intel® 64 and IA-32 Architectures instruction RDRAND and its underlying Digital Random Number Generator (DRNG) hardware implementation is useful for providing large entropy random numbers for which high quality keys for cryptographic protocols are created.
3.5.2.12 Intel® OS Guard
Protects a supported operating system (OS) from applications that have been tampered with or hacked by preventing an attack from being executed from application memory. Intel OS Guard also protects the OS from malware by blocking application access to critical OS vectors.
3.5.2.13 Trusted Platform Module (TPM)
Trusted Platform Module is bound to the platform and connected to the PCH via the LPC bus or SPI bus. The TPM provides the hardware-based mechanism to store or ‘seal’ keys and other data to the platform. It also provides the hardware mechanism to report platform attestations
memory population rules, and supported memory RAS features.
4.1 Memory Sub-system Architecture
Figure 9. Memory Sub-system Block Diagram technologies are not supported on this generation server board.
Intel® Server Board S2600WT Technical Product Specification
4.2 IMC Modes of operation
A memory controller can be configured to operate in one of two modes, and each IMC operates separately. Independent Mode: This is also known as performance mode. In this mode each DDR channel is addressed individually via burst lengths of 8 bytes. All processors support SECDED ECC with x8 DRAMs in independent mode. All processors support SDDC with x4 DRAMs in independent mode. Lockstep mode: This is also known as RAS mode. Each pair of channels shares a Write Push Logic unit to enable lockstep. The memory controller handles all cache lines across two interfaces on an IMC. The DRAM controllers in the same IMC share a common address decode and DMA engines for the mode. The same address is used on both channels, such that an address error on any channel is detectable by bad ECC. All processors support SDDC with x4 or x8 DRAMs in lockstep mode. For Lockstep Channel Mode and Mirroring Mode, processor channels are paired together as a “Domain”. CPU1 Mirroring/Lockstep Domain 1 = Channel A + Channel B CPU1 Mirroring/Lockstep Domain 2 = Channel C + Channel D CPU2 Mirroring/Lockstep Domain 1 = Channel E + Channel F CPU2 Mirroring/Lockstep Domain 2 = Channel G + Channel H The schedulers within each channel of a domain will operate in lockstep, they will issue requests in the same order and time and both schedulers will respond to an error in either one of the channels in a domain. Lockstep refers to splitting cache lines across channels. The same address is used on both channels, such that an address error on any channel is detectable by bad ECC. The ECC code used by the memory controller can correct 1/18th of the data in a code word. For x8 DRAMs, since there are 9 x8 DRAMs on a DIMM, a code word must be split across 2 DIMMs to allow the ECC to correct all the bits corrupted by an x8 DRAM failure. For RAS modes that require matching populations, the same slot positions across channels must hold the same DIMM type with regards to number of ranks, number of banks, number of rows, and number of columns. DIMM timings do not have to match but timings will be set to support all DIMMs populated (that is, DIMMs with slower timings will force faster DIMMs to the slower common timing modes).
4.3 Memory RASM Features
DRAM Single Device Data Correction (SDDC): SDDC provides error checking and correction that protects against a single x4 DRAM device failure (hard-errors) as well as multibit faults in any portion of a single DRAM device on a DIMM (require lockstep mode for x8 DRAM device based DIMM). Memory Disable and Map out for FRB: Allows memory initialization and booting to OS even when a memory fault occurs. Data Scrambling with Command and Address: Scrambles the data with address and command in "write cycle" and unscrambles the data in "read cycle". This feature addresses reliability by improving signal integrity at the physical layer, and by assisting with detection of an address bit error. DDR4 Command/Address Parity Check and Retry: DDR4 technology based CMD/ADDR parity check and retry with following attributes: CMD/ADDR Parity error address logging CMD/ADDR Retry
enabled, only half of the memory capacity of both memory channels is available. system memory, repairing correctable errors. It prevents accumulation of single-bit errors. and improving the reliability of the system. as spare ranks. Memory mirroring is not supported when memory sparing is enabled.
4.4 Supported Memory
Table 4. DDR4 RDIMM & LRDIMM Support E5-2600v3
3 Slots per Channel
1 DPC 2 DPC 3 DPC
Table 5. DDR4 RDIMM & LRDIMM Support E5-2600v4
4.5 NVDIMM Support
failure and across power cycles or platform resets. NVDIMMs are a combination of DRAM and NAND flash. supported with BIOS verions greater than R0015.
4.5.1 Supported NVDIMMs
Intel® Server Board S2600WT Technical Product Specification
4.5.2 NVDIMMs population Rules
Normal DIMM population rules still apply (ex RDIMMs and LRDIMMs can’t be mixed) NVDIMMs of same capacity may be mixed with RDIMMs in same channel NVDIMMs from different vendors may be mixed in the same system and even the same channel. How the DIMMs are installed in a system will affect performance, please refer to Intel® Grantley Platform Design Guide CDI Document #506549 for more DIMM population rules details. For enhanced performance, install equal capacity DIMMs across all memory channels. For highest performance, install identical DIMMs.
4.5.3 Supercab configurations
A custom form factor supercap will be available for Intel® Server systems (Vendor specific). This supercap will enable the maximum configuration (supercap per chassis). Chassis NVDIMM & Customized SuperCap 2U 2 NVDIMM + 2 Supercap 1U 1 NVDIMM + 1 Supercap
4.6 Memory Slot Identification and Population Rules
Note: Although mixed DIMM configurations may be functional, Intel only supports and performs platform validation on systems that are configured with identical DIMMs installed. Each installed processor provides four channels of memory. On the Intel® Server Board S2600WT each memory channel supports three memory slots, for a total possible 24 DIMMs installed. System memory is organized into physical slots on DDR4 memory channels that belong to processor sockets. The memory channels from processor socket 1 are identified as Channel A, B, C and D. The memory channels from processor socket 2 are identified as Channel E, F, G, and H. Each memory slot on the server board is identified by channel and slot number within that channel. For example, DIMM_A1 is the first slot on Channel A on processor 1; DIMM_E1 is the first DIMM socket on Channel E on processor 2. The memory slots associated with a given processor are unavailable if the corresponding processor socket is not populated. A processor may be installed without populating the associated memory slots, provided a second processor is installed with associated memory. In this case, the memory is shared by the processors. However, the platform suffers performance degradation and latency due to the remote memory. Processor sockets are self-contained and autonomous. However, all memory subsystem support (such as Memory RAS, Error Management,) in the BIOS setup are applied commonly across processor sockets. The BLUE memory slots on the server board identify the first memory slot for a given memory channel. DIMM population rules require that DIMMs within a channel be populated starting with the BLUE DIMM slot or DIMM farthest from the processor in a “fill-farthest” approach. In addition, when populating a Quad-rank DIMM with a Single- or Dual-rank DIMM in the same channel, the Quad-rank DIMM must be populated farthest from the processor. Intel MRC will check for correct DIMM placement.
Intel® Server Board S2600WT Technical Product Specification The following are the DIMM population requirements All DIMMs must be DDR4 DIMMs Only Error Correction Code (ECC) enabled RDIMMs, LRDIMMs and LRDIMM 3DS are supported Only RDIMMs, LRDIMMs and LRDIMM3DS with integrated on die thermal sensors (TROD) are supported DIMM slots on any memory channel must be filled following the “farthest fill first” rule. The DIMM slot farthest away from the processor socket must be filled first on any channel. This will always be designated on the board as Slot 1 for the channel. When one DIMM is used, it must be populated in the BLUE DIMM slot (farthest away from the CPU) of a given channel. A maximum of 8 ranks can be installed on any one channel, counting all ranks in each DIMM on the channel. DIMM types (RDIMM, LRDIMM and LRDIMM3DS) must not be mixed within or across processor sockets. This is a Fatal Error Halt in Memory Initialization. Mixing DIMMs of different frequencies and latencies is not supported within or across processor sockets. If a mixed configuration is encountered, the BIOS will attempt to operate at the highest common frequency and the lowest latency possible. LRDIMM Rank Multiplication Mode and Direct Map Mode must not be mixed within or across processor sockets. This is a Fatal Error Halt in Memory Initialization. In order to install 3 QR LRDIMMs on the same channel, they must be operated with Rank Multiplication as RM = 2. This will make each LRDIMM appear as a DR DIMM with ranks twice as large. RAS Modes Lockstep, Rank Sparing, and Mirroring are mutually exclusive in this BIOS. Only one operating mode may be selected, and it will be applied to the entire system. If a RAS Mode has been configured, and the memory population will not support it during boot, the system will fall back to Independent Channel Mode and log and display errors. Rank Sparing Mode is only possible when all channels that are populated with memory meet the requirement of having at least 2 SR or DR DIMM installed, or at least one QR DIMM installed, on each populated channel. Lockstep or Mirroring Modes require that for any channel pair that is populated with memory, the memory population on both channels of the pair must be identically sized.
Table 7. DIMM Population Matrix
1 X N
2 X X N
2 X X Y
3 X X X N
4 X X X X Y
4 X X X X N
5 X X X X X N
6 X X X X X X N
6 X X X X X X
8 X X X X X X X X Y
8 X X X X X X X X N
12 X X X X X X X X X X X X Y
12 X X X X X X X X X X X X N
16 X X X X X X X X X X X X X X X X Y
16 X X X X X X X X X X X X X X X X N
24 X X X X X X X X X X X X X X X X X X X X X X X X Y
M – Indicates whether the configuration supports the Mirrored Channel Mode of operation.
4.6.1 Memory Interleaving Support
across different memory channels, to allow for overlapping memory access. by the OS. The actual locality is described in ACPI Tables.
Intel® Server Board S2600WT Technical Product Specification
4.6.2 NUMA Configuration Support
This BIOS includes support for Non-Uniform Memory Access (NUMA) when more than one processor is installed in a board or one Cluster-on-Die (COD) capable processor installed. When NUMA support is enabled, interleaving is intra socket only, and the SRAT and SLIT ACPI tables are provided that show the locality of systems resources, especially memory, which allows a “NUMA Aware” OS to optimize which processor threads are used by processes which can benefit by having the best access to those resources. NUMA support and COD support are enabled/disabled (enabled by default) by an option on the Memory RAS and Performance screen in BIOS setup.
4.7 System Memory Sizing and Publishing
The address space configured in a system depends on the amount of actual physical memory installed, on the RAS configuration, and on the PCIe* configuration. RAS configurations reduce the memory space available in return for the RAS features. PCIe* devices which require address space for Memory Mapped IO (MMIO) with 32-bit or 64- bit addressing, increase the address space in use, and introduce discontinuities in the correspondence between physical memory and memory addresses. The discontinuities in addressing physical memory revolve around the 4GB 32-bit addressing limit. Since the system reserves memory address space just below the 4GB limit, and 32-bit MMIO is allocated just below that, the addresses assigned to physical memory go up to the bottom of the PCI allocations, then “jump” to above the 4GB limit into 64-bit space. See the comments below about Memory reservations.
4.7.1 Effects of Memory Configuration on Memory Sizing
The system BIOS supports 4 memory configurations – Independent Channel Mode and 3 different RAS Modes. In some modes, memory reserved for RAS functions reduce the amount of memory available. Independent Channel mode: In Independent Channel Mode, the amount of installed physical memory is the amount of effective memory available. There is no reduction. Lockstep Mode: For Lockstep Mode, the amount of installed physical memory is the amount of effective memory available. There is no reduction. Lockstep Mode only changes the addressing to address two channels in parallel. Rank Sparing Mode: In Rank Sparing mode, the largest rank on each channel is reserved as a spare rank for that channel. This reduces the available memory size by the sum of the sizes of the reserved ranks. Example: if a system has 2 16GB Quad Rank DIMMS on each of 4 channels on each of 2 processor sockets, the total installed memory will be (((2 * 16GB) * 4 channels) * 2 CPU sockets) = 256GB. For a 16GB QR DIMM, each rank would be 4GB. With one rank reserved on each channel, that would 32GB reserved. So the available effective memory size would be 256GB - 32GB, or 224GB. Mirroring Mode: Mirroring creates a duplicate image of the memory that is in use, which uses half of the available memory to mirror the other half. This reduces the available memory size to half of the installed physical memory. Example: if a system has 2 16GB Quad Rank DIMMS on each of 4 channels on each of 2 processor sockets, the total installed memory will be (((2 * 16GB) * 4 channels) * 2 CPU sockets) = 256GB. In Mirroring Mode, since half of the memory is reserved as a mirror image, the available memory size would be 128GB.
Intel® Server Board S2600WT Technical Product Specification
4.7.2 Publishing System Memory
There are a number of different situations in which the memory size and/or configuration are displayed. Most of these displays differ in one way or another, so the same memory configuration may appear to display differently, depending on when and where the display occurs. The BIOS displays the “Total Memory” of the system during POST if Quiet Boot is disabled in BIOS setup. This is the total size of memory discovered by the BIOS during POST, and is the sum of the individual sizes of installed DDR4 DIMMs in the system. The BIOS displays the “Effective Memory” of the system in the BIOS Setup. The term Effective Memory refers to the total size of all DDR4 DIMMs that are active (not disabled) and not used as redundant units (see Note below). The BIOS provides the total memory of the system in the main page of BIOS setup. This total is the same as the amount described by the first bullet above. If Quiet Boot is disabled, the BIOS displays the total system memory on the diagnostic screen at the end of POST. This total is the same as the amount described by the first bullet above. The BIOS provides the total amount of memory in the system by supporting the EFI Boot Service function, GetMemoryMap(). The BIOS provides the total amount of memory in the system by supporting the INT 15h, E820h function. For details, see the Advanced Configuration and Power Interface Specification. Note: Some server operating systems do not display the total physical memory installed. What is displayed is the amount of physical memory minus the approximate memory space used by system BIOS components. These BIOS components include but are not limited to: ACPI (may vary depending on the number of PCI devices detected in the system and the size of memory included on them) ACPI NVS table Processor microcode Memory Mapped I/O (MMIO) Manageability Engine (ME) BIOS flash
4.8 Memory Initialization
Memory Initialization at the beginning of POST includes multiple functions, including: DIMM discovery Channel training DIMM population validation check Memory controller initialization and other hardware settings Initialization of RAS configurations (as applicable) There are several errors which can be detected in different phases of initialization. During early POST, before system memory is available, serious errors that would prevent a system boot with data integrity will cause a System Halt with a beep code and a memory error code to be displayed via the POST Code Diagnostic LEDs. Less fatal errors will cause a POST Error Code to be generated as a Major Error. This POST Error Code will be displayed in the BIOS Setup Error Manager screen, and will also be logged to the System Event Log (SEL).
Intel® Server Board S2600WT Technical Product Specification
4.8.1 DIMM Discovery
Memory initialization begins by determining which DIMM slots have DIMMs installed in them. By reading the Serial Presence Detect (SPD) information from an SEEPROM on the DIMM, the type, size, latency, and other descriptive parameters for the DIMM can be acquired. Potential Error Cases: Memory is locked by Intel® TXT and is inaccessible – This will result in a Fatal Error Halt 0xE9. DIMM SPD does not respond – The DIMM will not be detected, which could result in a “No usable memory installed” Fatal Error Halt 0xE8 if there are no other detectable DIMMs in the system. The undetected DIMM could result later in an invalid configuration if the “no SPD” DIMM is in Slot 1 or 2 ahead of other DIMMs on the same channel. DIMM SPD read error – This DIMM will be disabled. POST Error Codes 856x “SPD Error” and 854x “DIMM Disabled” will be generated. If all DIMMs are failed, this will result in a Fatal Error Halt 0xE8. All DIMMs on the channel in higher-numbered sockets behind the disabled DIMM will also be disabled with a POST Error Code 854x “DIMM Disabled” for each. This could also result in a “No usable memory installed” Fatal Error Halt 0xE8. No usable memory installed – If no usable (not failed or disabled) DIMMs can be detected as installed in the system, this will result in a Fatal Error Halt 0xE8. Other error conditions which cause DIMMs to fail or be disabled so they are mapped out as unusable may result in causing this error when no usable DIMM remains in the memory configuration.
4.8.2 DIMM Population Validation Check
Once the DIMM SPD parameters have been read they are checked to verify that the DIMMs on the given channel are installed in a valid configuration. This includes checking for DIMM type, DRAM type and organization, DRAM rank organization, DIMM speed and size, ECC capability, and in which memory slots the DIMMs are installed. An invalid configuration may cause the system to halt. Potential Error Cases: Invalid DIMM (type, organization, speed, size) – If a DIMM is found that is not a type supported by the system, the following error will be generated: POST Error Code 8501 “DIMM Population Error”, and a “Population Error- Fatal Error Halt 0xED”. Invalid DIMM Installation – The DIMMs are installed incorrectly on a channel, not following the “Fill Farthest First” rule (Slot 1 must be filled before Slot 2, Slot 2 before Slot 3). This will result in a POST Error Code 8501 “DIMM Population Error” with the channel being disabled, and all DIMMs on the channel will be disabled with a POST Error Code 854x “DIMM Disabled” for each. This could also result in a “No usable memory installed” Fatal Error Halt 0xE8. Invalid DIMM Population – A QR LRDIMM in Direct Map mode which is installed in Slot3 on a 3 DIMM per channel server board is not allowed. This will result in a POST Error Code 8501 “DIMM Population Error” and a “Population Error” Fatal Error Halt 0xED. Mixed DIMM Types – A mixture of RDIMMs and/or LRDIMMs is not allowed. A mixture of LRDIMMs operating in Direct Map mode and Rank Multiplication mode is also not allowed. This will result in a POST Error Code 8501 “DIMM Population Error” and “Population Error” Fatal Error Halt 0xED. Mixed DIMM Parameters – Within an RDIMM or LRDIMM configuration, mixtures of valid DIMM technologies, sizes, speeds, latencies, etc., although not supported, will be initialized and operated on a best effort basis, if possible. No usable memory installed – If no enabled and available memory remains in the system, this will result in a Fatal Error Halt 0xE8.
Intel® Server Board S2600WT Technical Product Specification
4.8.3 Channel Training
The Integrated Memory Controller registers are programmed at the controller level and the memory channel level. Using the DIMM operational parameters, read from the SPD of the DIMMs on the channel, each channel is trained for optimal data transfer between the integrated memory controller (IMC) and the DIMMs installed on the given channel. Potential Error Cases: Channel Training Error – If the Data/Data Strobe timing on the channel cannot be set correctly so that the DIMMs can become operational, this results in a momentary Error Display 0xEA, and the channel is disabled. All DIMMs on the channel are marked as disabled, with POST Error Code 854x “DIMM Disabled” for each. If there are no populated channels which can be trained correctly, this becomes a Fatal Error Halt 0xEA.
4.8.3.1 Thermal (CLTT) and power throttling
Potential Error Cases:
- CLTT Structure Error – The CLTT initialization fails due to an error in the data structure passed in by the BIOS. This results in a Fatal Error Halt 0xEF. See chapter 7 for information describing CLTT.
4.8.3.2 Built-In Self Test (BIST)
Once the memory is functional, a memory test is executed. This is a hardware-based Built In Self Test (BIST) which confirms minimum acceptable functionality. Any DIMMs which fail are disabled and removed from the configuration. Potential Error Cases:
- Memory Test Error – The DIMM has failed BIST and is disabled. POST Error Codes 852x “Failed test/initialization” and 854x “DIMM Disabled” will be generated for each DIMM that fails. Any DIMMs installed on the channel behind the failed DIMM will be marked as disabled, with POST Error Code 854x “DIMM Disabled”. This results in a momentary Error Display 0xEB, and if all DIMMs have failed, this will result in a Fatal Error Halt 0xE8.
- No usable memory installed – If no enabled and available memory remains, this will result in a Fatal Error Halt 0xE8. The ECC functionality is enabled after all of memory has been cleared to zeroes to make sure that the data bits and the ECC bits are in agreement.
4.8.3.3 RAS Mode Initialization
If configured, the DIMM configuration is validated for the specified RAS mode. If the enabled DIMM configuration is compliant for the RAS mode selected, then the appropriate register settings are set and the RAS mode is started. Potential Error Cases:
- RAS Configuration Failure – If the DIMM configuration is not valid for the RAS mode which was selected, then the operating mode falls back to Independent Channel Mode, and a POST Error Code 8500 “Selected RAS Mode could not be configured” is generated. In addition, a “RAS Configuration Disabled” SEL entry for “RAS Configuration Status” (BIOS Sensor 02/Type 0Ch/Generator ID 01) is logged.
within the Emulex* Pilot-III Management Controller.
5.1 PCIe* Support
express* interface for general purpose PCI express* devices at up to PCI express* 3.0 speeds.
- All processors support a x4 DMI2 lane which can be connected to a PCH, or operate as a x4 PCIe* 2.0 port. The following tables provide the PCIe* port routing information:
**Table 8. PCIe* Port Routing CPU #1**
**Table 9. PCIe* Port Routing – CPU #2** Note: See section 5.4.1 for details of root port to PCIe* slot mapping for each supported riser card.
5.2 PCIe* Enumeration and Allocation
Scanning continues on the secondary side of the bridge until all subordinate buses are assigned numbers. never change during the pre-boot phase.
Intel® Server Board S2600WT Technical Product Specification up to match the behavior of the legacy BIOS after booting to a legacy OS. Legacy code cannot make any assumption about the scan order of devices or the order in which resources are allocated to them The BIOS automatically assigns IRQs to devices in the system for legacy compatibility. A method is not provided to manually configure the IRQs for devices.
5.3 PCIe* Non-Transparent Bridge (NTB)
PCI express* Non-Transparent Bridge (NTB) acts as a gateway that enables high performance, low overhead communication between two intelligent subsystems, the local and the remote subsystems. The NTB allows a local processor to independently configure and control the local subsystem, provides isolation of the local host memory domain from the remote host memory domain while enabling status and data exchange between the two domains. The PCI express* Port 3A of Intel® Xeon® Processor E5-2600 v3, v4 Product Families can be configured to be a transparent bridge or an NTB with x4/x8/x16 link width and Gen1/Gen2/Gen3 link speed. This NTB port could be attached to another NTB port or PCI express* Root Port on another subsystem. NTB supports three 64bit BARs as configuration space or prefetchable memory windows that can access both 32bit and 64bit address space through 64bit BARs. There are 3 NTB supported configurations:
- NTB Port to NTB Port Based Connection (Back-to-Back)
- NTB Port to Root Port Based Connection – Symmetric Configuration. The NTB port on the first system is connected to the root port of the second. The second system’s NTB port is connected to the root port on the first system making this a fully symmetric configuration.
- NTB Port to Root Port Based Connection – Non-Symmetric Configuration. The root port on the first system is connected to the NTB port of the second system. It is not necessary for the first system to be an Intel® Xeon® Processor E5-2600 v3, v4 Product Families system. Note: When NTB is enabled, Spread Spectrum Clocking (SSC) is required to be disabled at each NTB link. Additional NTB support information is available in the following Intel document: Intel® Server System BIOS External Product Specification.
5.4 Add-in Card Support
Figure 12. On-board Add-in Card Support
5.4.1 Riser Card Support
The server board provides three riser card slots identified as: Riser Slot #1, Riser Slot #2, and Riser Slot #3. following tables provide the PCIe* bus routing for all supported risers cards. bottom add-in card slot for 2U riser cards installed in Riser Slot #1.
**Table 10. Riser Card #1 - PCIe* Root Port Mapping** **Table 11. Riser Card #2 - PCIe* Root Port Mapping** **Table 12. Riser Slot #3 - PCIe* Root Port Mapping**
5.4.2 Intel® I/O Module Support
Figure 17. Server Board Layout - I/O Module Connector Table 13. Supported Intel® I/O Module Options
5.4.3 Intel® Integrated RAID Option
signals from the IIO module of the CPU 1 processor. Figure 18. Server Board Layout – Intel® Integrated RAID Module Option Placement
5.5 Serial ATA (SATA) Support
providing for up to ten 6 Gb/sec Serial ATA (SATA) ports.
- Four SATA ports from the Mini-SAS HD (SFF-8643) connector labeled “SATA Ports 0-3” on the server board
- Two SATA ports accessed via two white single port connectors labeled “SATA-4” and “SATA-5” on the server board The AHCI sSATA controller provides support for up to four SATA ports on the server board
- Four SATA ports from the Mini-SAS HD (SFF-8643) connector labeled “sSATA Ports 0-3” on the server board The following diagram identifies the location of all on-board SATA features.
Figure 19. Onboard SATA Features following table identifies supported setup options. Table 14. SATA and sSATA Controller BIOS Utility Setup Options
Table 15. SATA and sSATA Controller Feature Support
6 Gb/s Transfer Rate Capable of data transfers up to 6 Gb/s Supported Supported
5.5.1 Staggered Disk Spin-Up
startup than for normal operations. means that the drives are started up separately, with a certain delay between disk drives starting. Setup Mass Storage Controller Configuration screen found in the <F2> BIOS Setup Utility.
5.6 Embedded SATA SW-RAID support
Intel® Server Board S2600WT Technical Product Specification Intel® Embedded Server RAID Technology 2 (ESRT2) based on AVAGO* MegaRAID SW RAID technology 1.41 Using the <F2> BIOS Setup Utility, accessed during system POST, options are available to enable/disable SW RAID, and select which embedded software RAID option to use. Note: RAID partitions created using either RSTe or ESRT2 cannot span across the two embedded SATA controllers. Only drives attached to a common SATA controller can be included in a RAID partition. 5.6.1 Intel® Rapid Storage Technology (RSTe) 4.1 Intel® Rapid Storage Technology offers several options for RAID (Redundant Array of Independent Disks) to meet the needs of the end user. AHCI support provides higher performance and alleviates disk bottlenecks by taking advantage of the independent DMA engines that each SATA port offers in the chipset. RAID Level 0 – Non-redundant striping of drive volumes with performance scaling of up to 6 drives, enabling higher throughput for data intensive applications such as video editing. Data security is offered through RAID Level 1, which performs mirroring. RAID Level 10 provides high levels of storage performance with data protection, combining the fault- tolerance of RAID Level 1 with the performance of RAID Level 0. By striping RAID Level 1 segments, high I/O rates can be achieved on systems that require both performance and fault-tolerance. RAID Level 10 requires 4 hard drives, and provides the capacity of two drives. RAID Level 5 provides highly efficient storage while maintaining fault-tolerance on 3 or more drives. By striping parity, and rotating it across all disks, fault tolerance of any single drive is achieved while only consuming 1 drive worth of capacity. That is, a 3 drive RAID 5 has the capacity of 2 drives, or a 4 drive RAID 5 has the capacity of 3 drives. RAID 5 has high read transaction rates, with a medium write rate. RAID 5 is well suited for applications that require high amounts of storage while maintaining fault tolerance. Note: RAID configurations cannot span across the two embedded AHCI SATA controllers. By using Intel® RSTe, there is no loss of PCI resources (request/grant pair) or add-in card slot. Intel® RSTe functionality requires the following: The SW-RAID option must be enable in <F2> BIOS Setup Intel® RSTe option must be selected in <F2> BIOS Setup Intel® RSTe drivers must be loaded for the installed operating system At least two SATA drives needed to support RAID levels 0 or 1 At least three SATA drives needed to support RAID levels 5 At least four SATA drives needed to support RAID levels 10 With Intel® RSTe SW-RAID enabled, the following features are made available: A boot-time, pre-operating system environment, text mode user interface that allows the user to manage the RAID configuration on the system. Its feature set is kept simple to keep size to a minimum, but allows the user to create and delete RAID volumes and select recovery options when problems occur. The user interface can be accessed by pressing the <CTRL-I> keys during system POST. Provides boot support when using a RAID volume as a boot disk. It does this by providing Int13 services when a RAID volume needs to be accessed by MS-DOS applications (such as NTLDR) and by exporting the RAID volumes to the System BIOS for selection in the boot order At each boot up, provides the user with a status of the RAID volumes
enabling higher throughput for data intensive applications such as video editing. Data security is offered through RAID Level 1, which performs mirroring. Figure 20. SATA RAID 5 Upgrade Key Note: RAID configurations cannot span across the two embedded AHCI SATA controllers.
5.7 Network Interface
Figure 21. Network Interface Connectors The LED at the right of the connector indicates link speed as defined in the following table. Figure 22. External RJ45 NIC Port LED Definition controller option is present. See section 5.7.1 for details on available onboard network controller options.
5.7.1 Intel® Ethernet Controller Options
- Intel® Ethernet Controller X540 10 GbE (Server board product code - S2600WTTR)
- Intel® Ethernet Controller I350 1 GbE (Server board product code - S2600WT2R) Refer to the respective product data sheets for a complete list of supported Ethernet Controller features. LED Color LED State NIC State Left Green Off LAN link not established On LAN link is established Blinking Transmit / Receive Activity Right Off Lowest supported data rate Amber On Mid-range supported data rate Green On Highest supported data rate
5.7.2 Factory Programmed MAC Address Assignments
- NIC # 1 MAC address = Base #
- NIC # 2 MAC address = Base # + 1
- BMC LAN channel 0 MAC address = Base # + 2
- BMC LAN channel 1 MAC address = Base # + 3
- Dedicated On-board Management Port MAC address = Base # + 4 The following MAC address assignments are used for FCoE support on server boards with an on-board Intel® Ethernet Controller X540:
- NIC #1 SAN MAC address = Base # + 5
- NIC #2 SAN MAC address = Base # + 6 The base MAC address will be printed on a label and affixed to the server board and/or Intel server system. Factory programmed MAC addresses can also be viewed in the <F2> BIOS Setup Utility.
5.8 Video Support
Table 16. Video Modes result in lower video resolutions.
Intel® Server Board S2600WT Technical Product Specification connector. Attaching a monitor to the front panel video connector will disable the primary external video connector on the back edge of the board.
5.8.1 Dual Video and Add-In Video Adapters
There are enable/disable options in the <F2> BIOS Setup PCI Configuration screen for “Add-in Video Adapter” and “Onboard Video”.
- When Onboard Video is Enabled, and Add-in Video Adapter is also Enabled, then both video displays can be active. The onboard video is still the primary console and active during BIOS POST; the add-in video adapter would be active under an OS environment with the video driver support.
- When Onboard Video is Enabled, and Add-in Video Adapter is Disabled, then only the onboard video would be active.
- When Onboard Video is Disabled, and Add-in Video Adapter is Enabled, then only the add-in video adapter would be active. Configurations with add-in video cards can get more complicated on server boards that have two or more CPU sockets. Some multi-socket boards have PCIe* slots capable of hosting an add-in video card which are attached to the IIOs of CPU sockets other than CPU Socket 1. However, only one CPU Socket can be designated as “Legacy VGA Socket” as required in POST. To provide for this, there is another PCI Configuration option to control “Legacy VGA Socket”. The rules for this are:
- This option appears only on boards which have the possibility of an add-in video adapter in a PCIe* slot on a CPU socket other than socket 1.
- When present, the option is grayed out and unavailable unless an add-in video card is actually installed in a PCIe* slot connected to the other socket.
- Because the Onboard Video is “hardwired” to CPU Socket 1, whenever Legacy VGA Socket is set to a CPU Socket other than Socket 1 that disables both Onboard Video ports.
5.8.1.1 Dual Monitor Video
The BIOS supports single and dual video on the S2600 family of Server Board when add-in video adapters are installed. Although there is no enable/disable option in BIOS screen for Dual Video, it works when both “Onboard video” and “Add-in Video Adapter” are enabled. In the single video mode, the onboard video controller or the add-in video adapter is detected during the POST. In the dual video mode, the onboard video controller is enabled and is the primary video device while the add-in video adapter is allocated resources and is considered the secondary video device.
5.8.1.2 Configuration Cases – Multi-CPU Socket Boards and Add-In Video Adapters
Because this combination of CPU Socket and PCIe* topology is complicated and somewhat confusing, the following set of “Configuration Cases” was generated to clarify the design.
- When there are no add-in video cards installed... Case 1: Onboard Video only active display. Onboard Video = Enabled (grayout, can't change) Legacy VGA Socket = CPU Socket 1 (grayout, can't change) Add-in Video Adapter = Disabled (grayout, can't change)
- When there is one add-in video card connected to CPU Socket 1... Case 2: Onboard video active display, add-in video doesn't display. Onboard Video = Enabled
Intel® Server Board S2600WT Technical Product Specification Legacy VGA Socket = CPU Socket 1 (grayout, can't change) Add-in Video Adapter = Disabled Case 3: Add-in video active display, onboard video doesn't display. Onboard Video = Disabled, Legacy VGA Socket = CPU Socket 1 (grayout, can't change) Add-in Video Adapter = Enabled Case 4: Both onboard video and add-in video are active displays. But only onboard could be the active display during BIOS POST (Dual Monitor). Onboard Video = Enabled Legacy VGA Socket = CPU Socket 1 (grayout, can't change) Add-in Video Adapter = Enabled
- When there is one add-in video card connected to CPU Socket 2... Case 5: Onboard video active display, add-in doesn't display. Onboard Video = Enabled Legacy VGA Socket = CPU Socket 1 Add-in Video Adapter = Disabled (grayout, can't change) Case 6: Add-in video active display, onboard video doesn't display. Onboard Video = Disabled (grayout, can't change) Legacy VGA Socket = CPU Socket 2 Add-in Video Adapter = Enabled (grayout, can't change)
- When there are add-in video cards connected to both CPU Socket 1 & 2... Case 7: Onboard video active display, add-in video on Socket 1 and Add-in video on Socket 2 don’t actively display. Onboard Video = Enabled Legacy VGA Socket = CPU Socket 1 Add-in Video Adapter = Disabled Case 8: Add-in video on Socket 1 active display, onboard video and Add-in video on Socket 2 don’t actively display. Onboard Video = Disabled Legacy VGA Socket = CPU Socket 1 Add-in Video Adapter = Enabled Case 9: Both onboard video active and CPU Socket 1 add-in video active display. But only onboard could actively display during BIOS POST. Onboard Video = Enabled Legacy VGA Socket = CPU Socket 1 Add-in Video Adapter = Enabled Case 10: Only CPU Socket 2 add-in video active display, neither onboard video nor CPU Socket 1 add-in video display. Onboard Video = Disabled (grayout, can't change) Legacy VGA Socket = CPU Socket 2 Add-in Video Adapte = Enabled (grayout, can't change)
5.8.2 Setting Video Configuration Options using the BIOS Setup Utility
Figure 23. BIOS Setup Utility - Video Configuration Options on-board video controller becomes the primary video device. Comments: This option must be enabled to use an add-in card as a primary POST Legacy Video device. option set to CPU Socket 1, this option is set to Disabled and grayed out and unavailable. option set to CPU Socket 2, this option is set to Disabled and grayed out and unavailable. Enabled, the onboard video device works as primary video device while add-in video adapter as secondary.
Intel® Server Board S2600WT Technical Product Specification On-board video controller. Warning: System video is completely disabled if this option is disabled and an add-in video adapter is not installed. Comments: When disabled, the system requires an add-in video card for the video to be seen. When there is no add-in video card installed, Onboard Video is set to Enabled and grayed out so it cannot be changed. If there is an add-in video card installed in a PCIe* slot connected to CPU Socket 1, and the Legacy VGA Socket option is set to CPU Socket 1, then this Onboard Video option is available to be set and default as Disabled. If there is an add-in video card installed on a PCIe* slot connected to CPU Socket 2, and the Legacy VGA Socket option is set to CPU Socket 2, this option is grayed out and unavailable, with a value set to Disabled. This is because the Onboard Video is connected to CPU Socket 1, and is not functional when CPU Socket 2 is the active path for video. When Legacy VGA Socket is set back to CPU Socket 1, this option becomes available again and is set to its default value of Enabled. 3. Legacy VGA Socket Option Values: CPU Socket 1 CPU Socket 2 Help Text: Determines whether Legacy VGA video output is enabled for PCIe* slots attached to Processor Socket 1 or 2. Socket 1 is the default. Comments: This option is necessary when using an add-in video card on a PCIe* slot attached to CPU Socket 2, due to a limitation of the processor IIO. The Legacy video device can be connected through either socket but there is a setting that must be set on only one of the two. This option allows the switch to using a video card in a slot connected to CPU Socket 2. This option does not appear unless the BIOS is running on a board which has one processor installed on CPU Socket 2 and can potentially have a video card installed in a PCIe* slot connected to CPU Socket 2. This option is grayed out as unavailable and set to CPU Socket 1 unless there is a processor installed on CPU Socket 2 and a video card installed in a PCIe* slot connected to CPU Socket 2. When this option is active and is set to CPU Socket 2, then both Onboard Video and Dual Monitor Video are set to Disabled and grayed out as unavailable. This is because the Onboard Video is a PCIe* device connected to CPU Socket 1, and is unavailable when the Legacy VGA Socket is set to Socket 2.
5.9 USB Support
The server board provides support for both USB 2.0 (up to 480 Mb/sec) and USB 3.0 (up to 5 Gb/sec). Figure 24. Onboard USB Port Support Intel® Server Board S2600WT cannot be USB 3.0 certified with USB 3.0 ports cabled to a front panel.
5.9.1 Low Profile eUSB SSD Support
Figure 25. Low Profile eUSB SSD Support
- 2 wire small form factor Universal Serial Bus 2.0 (Hi-Speed USB) interface to host
- Read Speed up to 35 MB/s and write Speed up to 24 MB/s.
- Capacity range from 256 MB to 32 GB.
- Support USB Mass Storage Class requirements for Boot capability. Please visit the Intel® Server Configurator Tool at the following website for a list of supported eUSB SSD devices. https://serverconfigurator.intel.com
5.10 Serial Ports
connector located on the back edge of the server board. The Serial A connector has the following pin-out configuration. Table 17. Serial A Connector Pin-out the connector, from pins 1-2 (default) to pins 2-3.
from previous generation S2600GL/GZ which uses AMI EDK-I code. The Serial B connector has the following pin-out. Table 18. Serial-B Connector Pin-out
Intel® Server Board S2600WT Technical Product Specification 6. System Security The server board supports a variety of system security options designed to prevent unauthorized system access or tampering of server settings. System security options supported include:
- Password Protection
- Front Panel Lockout
- Trusted Platform Module (TPM) support
- Intel® Trusted Execution Technology
6.1 BIOS Setup Utility Security Options Menu
The <F2> BIOS Setup Utility, accessed during POST, includes a Security tab where options to configure passwords, front panel lockout, and TPM settings, can be found. Security Administrator Password Status <Installed/Not Installed> User Password Status <Installed/Not Installed> Set Administrator Password [123aBcDeFgH$#@] Set User Password [123aBcDeFgH$#@] Power On Password Enabled/Disabled Front Panel Lockout Enabled/Disabled TPM State <Displays current TPM Device State> TPM Administrative Control No Operation/Turn On/Turn Off/Clear Ownership
6.1.1 Password Setup
The BIOS uses passwords to prevent unauthorized access to the server. Passwords can restrict entry to the BIOS Setup utility, restrict use of the Boot Device popup menu during POST, suppress automatic USB device re-ordering, and prevent unauthorized system power on. It is strongly recommended that an Administrator Password be set. A system with no Administrator password set allows anyone who has access to the server to change BIOS settings. An Administrator password must be set in order to set the User password.
Intel® Server Board S2600WT Technical Product Specification The maximum length of a password is 14 characters and can be made up of a combination of alphanumeric (a-z, A-Z, 0-9) characters and any of the following special characters: Passwords are case sensitive. The Administrator and User passwords must be different from each other. An error message will be displayed and a different password must be entered if there is an attempt to enter the same password for both. The use of “Strong Passwords” is encouraged, but not required. In order to meet the criteria for a strong password, the password entered must be at least 8 characters in length, and must include at least one each of alphabetic, numeric, and special characters. If a weak password is entered, a warning message will be displayed, and the weak password will be accepted. Once set, a password can be cleared by changing it to a null string. This requires the Administrator password, and must be done through BIOS Setup. Clearing the Administrator password will also clear the User password. Passwords can also be cleared by using the Password Clear jumper on the server board. See Chapter 10 – Reset and Recovery Jumpers. Resetting the BIOS configuration settings to default values (by any method) has no effect on the Administrator and User passwords. As a security measure, if a User or Administrator enters an incorrect password three times in a row during the boot sequence, the system is placed into a halt state. A system reset is required to exit out of the halt state. This feature makes it more difficult to guess or break a password. In addition, on the next successful reboot, the Error Manager displays a Major Error code 0048, which also logs a SEL event to alert the authorized user or administrator that a password access failure has occurred. Note: When BIOS admin password is set, and user is updating the BIOS with a customized by the ITK tool the command requires to append password=”[AdminPassword]” to the commands of Iflash32. Example: Iflash32.efi /u /ni “[Bios File.cap]” password=”[AdminPassword]”
6.1.2 System Administrator Password Rights
When the correct Administrator password is entered when prompted, the user has the ability to perform the following:
- Access the <F2> BIOS Setup Utility
- Configure all BIOS setup options in the <F2> BIOS Setup Utility
- Clear both the Administrator and User passwords
- Access the <F6> Boot Menu during POST
- If the Power On Password function is enabled in BIOS Setup, the BIOS will halt early in POST to request a password (Administrator or User) before continuing POST.
6.1.3 Authorized System User Password Rights and Restrictions
When the correct User password is entered, the user has the ability to perform the following:
- Access the <F2> BIOS Setup Utility
- View, but not change, any BIOS Setup options in the <F2> BIOS Setup Utility
- Modify System Time and Date in the BIOS Setup Utility
- If the Power On Password function is enabled in BIOS Setup, the BIOS will halt early in POST to request a password (Administrator or User) before continuing POST Configuring an Administrator password imposes restrictions on booting the system, and configures most Setup fields to read-only if the Administrator password is not provided. The F6 Boot popup menu requires
Intel® Server Board S2600WT Technical Product Specification the Administrator password to function, and the USB Reordering is suppressed as long as the Administrator password is enabled. Users are restricted from booting in anything other than the Boot Order defined in Setup by an Administrator.
6.1.4 Front Panel Lockout
If enabled in BIOS setup, this option disables the following front panel features:
- The OFF function of the Power button
- System Reset button
- NMI Diagnostic Interrupt button If [Enabled] is selected, system power off and reset must be controlled via a system management interface.
6.2 Trusted Platform Module (TPM) Support
The server board has the option to support a Trusted Platform Module (TPM) which plugs into a high density 14-pin connector labeled “TPM”. A TPM is a hardware-based security device that addresses the growing concern on boot process integrity and offers better data protection. TPM protects the system start-up process by ensuring it is tamper-free before releasing system control to the operating system. A TPM device provides secured storage to store data, such as security keys and passwords. In addition, a TPM device has encryption and hash functions. The server board implements TPM as per TPM PC Client specifications revision 1.2 and 2.0 by the Trusted Computing Group (TCG). A TPM device is secured from external software attacks and physical theft. A pre-boot environment, such as the BIOS and operating system loader, uses the TPM to collect and store unique measurements from multiple factors within the boot process to create a system fingerprint. This unique fingerprint remains the same unless the pre-boot environment is tampered with. Therefore, it is used to compare to future measurements to verify the integrity of the boot process. After the system BIOS completes the measurement of its boot process, it hands off control to the operating system loader and in turn to the operating system. If the operating system is TPM-enabled, it compares the BIOS TPM measurements to those of previous boots to make sure the system was not tampered with before
Intel® Server Board S2600WT Technical Product Specification continuing the operating system boot process. Once the operating system is in operation, it optionally uses TPM to provide additional system and data security.
6.2.1 TPM security BIOS
The BIOS TPM support conforms to the TPM PC Client Implementation Specification for Conventional BIOS, the TPM Interface Specification, and the Microsoft Windows BitLocker* Requirements. The role of the BIOS for TPM security includes the following: Measures and stores the boot process in the TPM microcontroller to allow a TPM enabled operating system to verify system boot integrity. Produces EFI and legacy interfaces to a TPM-enabled operating system for using TPM. Produces ACPI TPM device and methods to allow a TPM-enabled operating system to send TPM administrative command requests to the BIOS. Verifies operator physical presence. Confirms and executes operating system TPM administrative command requests. Provides BIOS Setup options to change TPM security states and to clear TPM ownership. For additional details, refer to the TCG PC Client Specific Implementation Specification, the TCG PC Client Specific Physical Presence Interface Specification, and the Microsoft BitLocker* Requirement documents.
6.2.2 Physical Presence
Administrative operations to the TPM require TPM ownership or physical presence indication by the operator to confirm the execution of administrative operations. The BIOS implements the operator presence indication by verifying the setup Administrator password. A TPM administrative sequence invoked from the operating system proceeds as follows: 1. User makes a TPM administrative request through the operating system’s security software. 2. The operating system requests the BIOS to execute the TPM administrative command through TPM ACPI methods and then resets the system. 3. The BIOS verifies the physical presence and confirms the command with the operator. 4. The BIOS executes TPM administrative command(s), inhibits BIOS Setup entry and boots directly to the operating system which requested the TPM command(s).
6.2.3 TPM Security Setup Options
The BIOS TPM Setup allows the operator to view the current TPM state and to carry out rudimentary TPM administrative operations. Performing TPM administrative options through the BIOS setup requires TPM physical presence verification. TPM administrative options are only shown in the Security Menu screen when a TPM is physically installed on the board. Using BIOS TPM Setup, the operator can turn ON or OFF TPM functionality and clear the TPM ownership contents. After the requested TPM BIOS Setup operation is carried out, the option reverts to No Operation. The BIOS TPM Setup also displays the current state of the TPM, whether TPM is enabled or disabled and activated or deactivated. Note that while using TPM, a TPM-enabled operating system or application may change the TPM state independent of the BIOS setup. When an operating system modifies the TPM state, the BIOS Setup displays the updated TPM state. The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to take control of the system with TPM. You use this option to clear security settings for a newly initialized system or to clear a system for which the TPM ownership security key was lost. TPM Setup Options using the BIOS Setup Utility
Table 19. TPM Setup Utility – Security Configuration Screen Fields Shows the current TPM device state. allowed if not present already. [Turn On] - Enables and activates TPM. TPM to a factory default state.
6.3 Intel® Trusted Execution Technology
information without compromising the usability of the platform. Trusted Computing Group TPM PC Client Specifications, Revision 1.2 or 2.0.
Intel® Server Board S2600WT Technical Product Specification 7. Platform Management Platform management is supported by several hardware and software components integrated on the server board that work together to support the following: Control systems functions – power system, ACPI, system reset control, system initialization, front panel interface, system event log Monitor various board and system sensors, regulate platform thermals and performance in order to maintain (when possible) server functionality in the event of component failure and/or environmentally stressed conditions Monitor and report system health Provide an interface for Server Management Software applications This chapter provides a high level overview of the platform management features and functionality implemented on the server board. The Intel® Server System BMC Firmware External Product Specification (EPS) and the Intel® Server System BIOS External Product Specification (EPS) for Intel® Server products based on the Intel® Xeon® processor E5- 2600 v3, v4 product families should be referenced for more in-depth and design level platform management information.
7.1 Management Feature Set Overview
The following sections outline features that the integrated BMC firmware can support. Support and utilization for some features is dependent on the server platform in which the server board is integrated and any additional system level components and options that may be installed. 7.1.1 IPMI 2.0 Features Overview Baseboard management controller (BMC) IPMI Watchdog timer Messaging support, including command bridging and user/session support Chassis device functionality, including power/reset control and BIOS boot flags support Event receiver device: The BMC receives and processes events from other platform subsystems. Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access to system FRU devices using IPMI FRU commands. System Event Log (SEL) device functionality: The BMC supports and provides access to a SEL including SEL Severity Tracking and the Extended SEL Sensor Data Record (SDR) repository device functionality: The BMC supports storage and access of system SDRs. Sensor device and sensor scanning/monitoring: The BMC provides IPMI management of sensors. It polls sensors to monitor and report system health. IPMI interfaces o Host interfaces include system management software (SMS) with receive message queue support, and server management mode (SMM) o IPMB interface o LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+) Serial-over-LAN (SOL) ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the BIOS.
Intel® Server Board S2600WT Technical Product Specification BMC self-test: The BMC performs initialization and run-time self-tests and makes results available to external entities. See also the Intelligent Platform Management Interface Specification Second Generation v2.0.
7.1.2 Non IPMI Features Overview
The BMC supports the following non-IPMI features. In-circuit BMC firmware update Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality. Chassis intrusion detection (dependent on platform support) Fan speed control with SDR Fan redundancy monitoring and support Enhancements to fan speed control. Power supply redundancy monitoring and support Hot-swap fan support Acoustic management: Support for multiple fan profiles Signal testing support: The BMC provides test commands for setting and getting platform signal states. The BMC generates diagnostic beep codes for fault conditions. System GUID storage and retrieval Front panel management: The BMC controls the system status LED and chassis ID LED. It supports secure lockout of certain front panel functionality and monitors button presses. The chassis ID LED is turned on using a front panel button or a command. Power state retention Power fault analysis Intel® Light-Guided Diagnostics Power unit management: Support for power unit sensor. The BMC handles power-good dropout conditions. DIMM temperature monitoring: New sensors and improved acoustic management using closed-loop fan control algorithm taking into account DIMM temperature readings. Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on embedded NICs). Dynamic Host Configuration Protocol (DHCP): The BMC can act as a DHCP client on all on-board LAN interfaces Platform environment control interface (PECI) thermal management support E-mail alerting Support for embedded web server UI in Basic Manageability feature set. Enhancements to embedded web server o Human-readable SEL o Additional system configurability o Additional system monitoring capability o Enhanced on-line help Integrated KVM (with Intel® RMM4 Lite option installed) Enhancements to KVM redirection (with Intel® RMM4 Lite option installed) o Support for higher resolution
that prevents a user from updating the BMC. o BMC System Management Health Monitoring.
7.2 Platform Management Features and Functions
7.2.1 Power Sub-system
Table 20. Server Board Power Control Sources
7.2.2 Advanced Configuration and Power Interface (ACPI)
Table 21. ACPI Power States The front panel power LED is on (not controlled by the BMC). The fans spin at the normal speed, as determined by sensor inputs. Front panel buttons work normally. The front panel buttons are not locked. The power-up process goes through the normal boot process. The power, reset, front panel NMI, and ID buttons are unlocked.
7.2.3 System Initialization
During system initialization, both the BIOS and the BMC initialize the following items.
7.2.3.1 Processor Tcontrol Setting
BMC uses these values as part of the fan-speed-control algorithm.
7.2.3.2 Fault Resilient Booting (FRB)
that the BIOS is using the timer for the FRB2 phase of the boot operation. watchdog timer with the new timeout interval. system, assuming the BIOS-selected reset as the watchdog timeout action.
Intel® Server Board S2600WT Technical Product Specification The FRB2 failure does not affect the front panel LEDs.
7.2.3.3 Post Code Display
The BMC, upon receiving standby power, initializes internal hardware to monitor port 80h (POST code) writes. Data written to port 80h is output to the system POST LEDs. The BMC deactivates POST LEDs after POST had completed. Refer to Appendix D for a complete list of supported POST Code Diagnostic LEDs.
7.2.4 Watchdog Timer
The BMC implements a fully IPMI 2.0-compatible watchdog timer. For details, see the Intelligent Platform Management Interface Specification Second Generation v2.0. The NMI/diagnostic interrupt for an IPMI 2.0 watchdog timer is associated with an NMI. A watchdog pre-timeout SMI or equivalent signal assertion is not supported.
7.2.5 System Event Log (SEL)
The BMC implements the system event log as specified in the Intelligent Platform Management Interface Specification, Version 2.0. The SEL is accessible regardless of the system power state through the BMC's in- band and out-of-band interfaces. The BMC allocates 95231 bytes (approximately 93 KB) of non-volatile storage space to store system events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be stored at a time. Because the SEL is circular, any command that results in an overflow of the SEL beyond the allocated space will overwrite the oldest entries in the SEL, while setting the overflow flag.
7.3 Sensor Monitoring
The BMC monitors system hardware and reports system health. The information gathered from physical sensors is translated into IPMI sensors as part of the “IPMI Sensor Model”. The BMC also reports various system state changes by maintaining virtual sensors that are not specifically tied to physical hardware. This section describes general aspects of BMC sensor management as well as describing how specific sensor types are modeled. Unless otherwise specified, the term “sensor” refers to the IPMI sensor-model definition of a sensor.
7.3.1 Sensor Scanning
The value of many of the BMC’s sensors is derived by the BMC FW periodically polling physical sensors in the system to read temperature, voltages, and so on. Some of these physical sensors are built in to the BMC component itself and some are physically separated from the BMC. Polling of physical sensors for support of IPMI sensor monitoring does not occur until the BMC’s operational code is running and the IPMI FW subsystem has completed initialization. IPMI sensor monitoring is not supported in the BMC boot code. Additionally, the BMC selectively polls physical sensors based on the current power and reset state of the system and the availability of the physical sensor when in that state. For example, non-standby voltages are not monitored when the system is in a S5 power state.
7.3.2 Sensor Rearm Behavior
7.3.2.1 Manual versus Re-arm Sensors
Sensors can be either manual or automatic re-arm. An automatic re-arm sensor will "re-arm" (clear) the assertion event state for a threshold or offset if that threshold or offset is de-asserted after having been asserted. This allows a subsequent assertion of the threshold or an offset to generate a new event and associated side-effect. An example side-effect would be boosting fans due to an upper critical threshold crossing of a temperature sensor. The event state and the input state (value) of the sensor track each other. Most sensors are auto-rearm.
Intel® Server Board S2600WT Technical Product Specification A manual re-arm sensor does not clear the assertion state even when the threshold or offset becomes de- asserted. In this case, the event state and the input state (value) of the sensor do not track each other. The event assertion state is "sticky". The following methods can be used to re-arm a sensor:
- Automatic re-arm – Only applies to sensors that are designated as “auto-rearm”.
- IPMI command Re-arm Sensor Event
- BMC internal method – The BMC may re-arm certain sensors due to a trigger condition. For example, some sensors may be re-armed due to a system reset. A BMC reset will re-arm all sensors.
- System reset or DC power cycle will re-arm all system fan sensors.
7.3.2.2 Re-arm and Event Generation
All BMC-owned sensors that show an asserted event status generate a de-assertion SEL event when the sensor is re-armed, provided that the associated SDR is configured to enable a de-assertion event for that condition. This applies regardless of whether the sensor is a threshold/analog sensor or a discrete sensor. To manually re-arm the sensors, the sequence is outlined below: 1. A failure condition occurs, and the BMC logs an assertion event. 2. If this failure condition disappears, the BMC logs a de-assertion event (if so configured.) 3. The sensor is re-armed by one of the methods described in the previous section. 4. The BMC clears the sensor status. 5. The sensor is put into "reading-state-unavailable" state until it is polled again or otherwise updated. 6. The sensor is updated and the “reading-state-unavailable” state is cleared. A new assertion event will be logged if the fault state is once again detected. All auto-rearm sensors that show an asserted event status generate a de-assertion SEL event at the time the BMC detects that the condition causing the original assertion is no longer present; and the associated SDR is configured to enable a de-assertion event for that condition.
7.3.3 BIOS Event-Only Sensors
BIOS-owned discrete sensors are used for event generation only and are not accessible through IPMI sensor commands like the Get Sensor Reading command. Note that in this case the sensor owner designated in the SDR is not the BMC. An example of this usage would be the SELs logged by the BIOS for uncorrectable memory errors. Such SEL entries would identify a BIOS-owned sensor ID.
7.3.4 Margin Sensors
There is sometimes a need for an IPMI sensor to report the difference (margin) from a non-zero reference offset. For the purposes of this document, these type sensors are referred to as margin sensors. For instance, for the case of a temperature margin sensor, if the reference value is 90 degrees and the actual temperature of the device being monitored is 85 degrees, the margin value would be -5.
7.3.5 IPMI Watchdog Sensor
The BMC supports a Watchdog Sensor as a means to log SEL events due to expirations of the IPMI 2.0 compliant Watchdog Timer.
7.3.6 BMC Watchdog Sensor
The BMC supports an IPMI sensor to report that a BMC reset has occurred due to action taken by the BMC Watchdog feature. A SEL event will be logged whenever either the BMC FW stack is reset or the BMC CPU itself is reset.
Intel® Server Board S2600WT Technical Product Specification
7.3.7 BMC System Management Health Monitoring
The BMC tracks the health of each of its IPMI sensors and report failures by providing a “BMC FW Health” sensor of the IPMI 2.0 sensor type Management Subsystem Health with support for the Sensor Failure offset. Only assertions should be logged into the SEL for the Sensor Failure offset. The BMC Firmware Health sensor asserts for any sensor when 10 consecutive sensor errors are read. These are not standard sensor events (that is, threshold crossings or discrete assertions), these are BMC Hardware Access Layer (HAL) errors. This means the BMC is unable to get a reading from the sensor. If a successful sensor read is completed, the counter resets to zero.
7.3.8 VR Watchdog Timer
The BMC FW monitors that the power sequence for the board VR controllers is completed when a DC power- on is initiated. Incompletion of the sequence indicates a board problem, in which case the FW powers down the system. The BMC FW supports a discrete IPMI sensor for reporting and logging this fault condition.
7.3.9 System Airflow Monitoring
This sensor is only available on systems at Intel® chassis. BMC provides an IPMI sensor to report the volumetric system airflow in CFM (cubic feet per minute). The air flow in CFM is calculated based on the system fan Pulse Width Modulation (PWM) values. The specific PWM or PWMs, used to determine the CFM is SDR configurable. The relationship between PWM and CFM is based on a lookup table in an OEM SDR. The airflow data is used in the calculation for exit air temperature monitoring. It is exposed as an IPMI sensor to allow a datacenter management application to access this data for use in rack-level thermal management.
7.3.10 Thermal Monitoring
The BMC provides monitoring of component and board temperature sensing devices. This monitoring capability is instantiated in the form of IPMI analog/threshold or discrete sensors, depending on the nature of the measurement. For analog/threshold sensors, with the exception of Processor Temperature sensors, critical and non-critical thresholds (upper and lower) are set through SDRs and event generation enabled for both assertion and de- assertion events. For discrete sensors, both assertion and de-assertion event generation are enabled. Mandatory monitoring of platform thermal sensors includes:
- Inlet temperature (physical sensor is typically on system front panel or HDD back plane)
- Board ambient thermal sensors
- Processor temperature
- Memory (DIMM) temperature
- CPU VRD Hot monitoring
- Power supply inlet temperature (only supported for PMBus*-compliant PSUs) Additionally, the BMC FW may create “virtual” sensors that are based on a combination of aggregation of multiple physical thermal sensors and application of a mathematical formula to thermal or power sensor readings.
7.3.10.1 Absolute Value versus Margin Sensors
Thermal monitoring sensors fall into three basic categories:
- Absolute temperature sensors – These are analog/threshold sensors that provide a value that corresponds to an absolute temperature value.
Intel® Server Board S2600WT Technical Product Specification
- Thermal margin sensors – These are analog/threshold sensors that provide a value that is relative to some reference value.
- Thermal fault indication sensors – These are discrete sensors that indicate a specific thermal fault condition.
7.3.10.2 Processor DTS-Spec Margin Sensor(s)
Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family incorporate a DTS based thermal spec. This allows a much more accurate control of the thermal solution and will enable lower fan speeds and lower fan power consumption. The main usage of this sensor is as an input to the BMC’s fan control algorithms. The BMC implements this as a threshold sensor. There is one DTS sensor for each installed physical processor package. Thresholds are not set and alert generation is not enabled for these sensors. DTS 2.0 is implemented on new Intel board generation DTS 2.0 incorporates platform-visible thermal data interfaces and internal algorithms for calculating the relevant thermal data. As the major difference between the DTS1.0 and DTS 2.0 is that allows the CPUs to automatically calculate thermal gap/margin to DTS profile as input for Fan Speed Control. , DTS2.0 helps to further optimize system acoustics. Please refer to iBL #455822(Platform Digital Thermal Sensor (DTS) Based Thermal Specifications and Overview – Rev. 1.5) for more details about DTS2.0.
7.3.10.3 Processor Thermal Margin Sensor(s)
Each processor supports a physical thermal margin sensor per core that is readable through the PECI interface. This provides a relative value representing a thermal margin from the core’s throttling thermal trip point. Assuming that temperature controlled throttling is enabled; the physical core temperature sensor reads ‘0’, which indicates the processor core is being throttled. The BMC supports one IPMI processor (margin) temperature sensor per physical processor package. This sensor aggregates the readings of the individual core temperatures in a package to provide the hottest core temperature reading. When the sensor reads ‘0’, it indicates that the hottest processor core is throttling. Due to the fact that the readings are capped at the core’s thermal throttling trip point (reading = 0), thresholds are not set and alert generation is not enabled for these sensors.
7.3.10.4 Processor Thermal Control Monitoring (Prochot)
The BMC FW monitors the percentage of time that a processor has been operationally constrained over a given time window (nominally six seconds) due to internal thermal management algorithms engaging to reduce the temperature of the device. When any processor core temperature reaches its maximum operating temperature, the processor package PROCHOT# (processor hot) signal is asserted and these management algorithms, known as the Thermal Control Circuit (TCC), engage to reduce the temperature, provided TCC is enabled. TCC is enabled by BIOS during system boot. This monitoring is instantiated as one IPMI analog/threshold sensor per processor package. The BMC implements this as a threshold sensor on a per- processor basis. Under normal operation, this sensor is expected to read ‘0’ indicating that no processor throttling has occurred. The processor provides PECI-accessible counters, one for the total processor time elapsed and one for the total thermally constrained time, which are used to calculate the percentage assertion over the given time window.
7.3.10.5 Processor Voltage Regulator (VRD) Over-Temperature Sensor
The BMC monitors processor VRD_HOT# signals. The processor VRD_HOT# signals are routed to the respective processor PROCHOT# input in order to initiate throttling to reduce processor power draw, therefore indirectly lowering the VRD temperature.
Intel® Server Board S2600WT Technical Product Specification There is one processor VRD_HOT# signal per CPU slot. The memory VRD_HOT# signals are routed to the respective processor MEMHOT# inputs in order to throttle the associated memory to effectively lower the temperature of the VRD feeding that memory. For Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family there are 2 memory VRD_HOT# signals per CPU slot. The BMC instantiates one discrete IPMI sensor for each processor and memory VRD_HOT# signal.
7.3.10.6 Inlet Temperature Sensor
Each platform supports a thermal sensor for monitoring the inlet temperature. In most cases, ME firmware will issue Get Sensor Reading IPMI command to the BMC to get the Inlet temperature. ME firmware determines which of the BMC thermal sensors to use for inlet temperature. For Intel® chassis, the inlet temperature sensor is on HSBP with address 21h. For 3rd chassis, sensor 20h which is on the front edge of baseboard can be used as inlet temperature sensor with several degrees offset from actual inlet temperature.
7.3.10.7 Baseboard Ambient Temperature Sensor(s)
The server baseboard provides one or more physical thermal sensors for monitoring the ambient temperature of a board location. This is typically to provide rudimentary thermal monitoring of components that lack internal thermal sensors.
7.3.10.8 Server South Bridge (SSB) Thermal Monitoring
The BMC monitors the SSB temperature. This is instantiated as an analog (threshold) IPMI thermal sensor.
7.3.10.9 Exit Air Temperature Monitoring
This sensor is only available on systems in an Intel® chassis. BMC synthesizes a virtual sensor to approximate system exit air temperature for use in fan control. This is calculated based on the total power being consumed by the system and the total volumetric air flow provided by the system fans. Each system shall be characterized in tabular format to understand total volumetric flow versus fan speed. The BMC calculates an average exit air temperature based on the total system power, front panel temperature, and the volumetric system air flow (cubic feet per meter or CFM). The Exit Air temp sensor is only available when PMBus* power supplies are installed.
7.3.10.10 Ethernet Controller Thermal Monitoring
The Intel® Ethernet Controller I350-AM4 and Intel® Ethernet Controller 10 Gigabit X540 support an on-die thermal sensor. For baseboard Ethernet controllers that use these devices, the BMC will monitor the sensors and use this data as input to the fan speed control. The BMC will instantiate an IPMI temperature sensor for each device on the baseboard.
7.3.10.11 Memory VRD-Hot Sensor(s)
The BMC monitors memory VRD_HOT# signals. The memory VRD_HOT# signals are routed to the respective processor MEMHOT# inputs in order to throttle the associated memory to effectively lower the temperature of the VRD feeding that memory. For Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family there are 2 memory VRD_HOT# signals per CPU slot. The BMC instantiates one discrete IPMI sensor for each memory VRD_HOT# signal.
7.3.10.12 Add-in Module Thermal Monitoring
Some boards have dedicated slots for an IO module and/or a SAS module. For boards that support these slots, the BMC will instantiate an IPMI temperature sensor for each slot. The modules themselves may or may
Intel® Server Board S2600WT Technical Product Specification not provide a physical thermal sensor (a TMP75 device). If the BMC detects that a module is installed, it will attempt to access the physical thermal sensor and, if found, enable the associated IPMI temperature sensor.
7.3.10.13 Processor ThermTrip
When a Processor ThermTrip occurs, the system hardware will automatically power down the server. If the BMC detects that a ThermTrip occurred, then it will set the ThermTrip offset for the applicable processor status sensor.
7.3.10.14 Server South Bridge (SSB) ThermTrip Monitoring
The BMC supports SSB ThermTrip monitoring that is instantiated as an IPMI discrete sensor. When a SSB ThermTrip occurs, the system hardware will automatically power down the server and the BMC will assert the sensor offset and log an event.
7.3.10.15 DIMM ThermTrip Monitoring
The BMC supports DIMM ThermTrip monitoring that is instantiated as one aggregate IPMI discrete sensor per CPU. When a DIMM ThermTrip occurs, the system hardware will automatically power down the server and the BMC will assert the sensor offset and log an event. This is a manual re-arm sensor that is rearmed on system resets and power-on (AC or DC power on transitions).
7.3.11 Processor Sensors
The BMC provides IPMI sensors for processors and associated components, such as voltage regulators and fans. The sensors are implemented on a per-processor basis. Table 22. Processor Sensors
Description
Processor Status Yes Processor presence and fault state Digital Thermal Sensor Yes Relative temperature reading by means of PECI Processor VRD Over-Temperature Indication Yes Discrete sensor that indicates a processor VRD has crossed an upper operating temperature threshold Processor Voltage Yes Threshold sensor that indicates a processor power- good state Processor Thermal Control (PROCHOT#) Yes Percentage of time a processor is throttling due to thermal conditions
7.3.11.1 Processor Status Sensors
The BMC provides an IPMI sensor of type processor for monitoring status information for each processor slot. If an event state (sensor offset) has been asserted, it remains asserted until one of the following happens: 1. A Rearm Sensor Events command is executed for the processor status sensor. 2. AC or DC power cycle, system reset, or system boot occurs. The BMC provides system status indication to the front panel LEDs for processor fault conditions as listed in following table. CPU Presence status is not saved across AC power cycles and therefore will not generate a de-assertion after cycling AC power.
Table 23. Processor Status Sensor Implementation
0 Internal error (IERR) Not Supported
1 Thermal trip BMC
2 FRB1/BIST failure Not Supported
3 FRB2/Hang in POST failure BIOS1
4 FRB3/Processor startup/initialization failure (CPU fails to start) Not Supported
5 Configuration error (for DMI) BIOS1
6 SMBIOS uncorrectable CPU-complex error Not Supported
7 Processor presence detected BMC
8 Processor disabled Not Supported
9 Terminator presence detected Not Supported
- Fault is not reflected in the processor status sensor.
7.3.11.2 Processor Population Fault (CPU Missing) Sensor
processor sockets are not populated as required by the platform HW to allow power-on of the system. beep code is generated if this fault is detected.
- Install a processor into the CPU _1 socket
7.3.11.3 ERR2 Timeout Monitoring
condition prevents the BIOS from running. detection of this condition.
7.3.11.4 CATERR Sensor
The BMC supports a CATERR sensor for monitoring the system CATERR signal.
- high (no event)
- pulsed low (possibly fatal may be able to recover)
- low (fatal).
Intel® Server Board S2600WT Technical Product Specification All processors in a system have their CATERR pins tied together. The pin is used as a communication path to signal a catastrophic system event to all CPUs. The BMC has direct access to this aggregate CATERR signal. The BMC only monitors for the “CATERR held low” condition. A pulsed low condition is ignored by the BMC. If a CATERR-low condition is detected, the BMC logs an error message to the SEL against the CATERR sensor and the default action after logging the SEL entry is to reset the system. The BIOS setup utility provides an option to disable or enable system reset by the BMC for detection of this condition. The sensor is rearmed on power-on (AC or DC power on transitions). It is not rearmed on system resets in order to avoid multiple SEL events that could occur due to a potential reset loop if the CATERR keeps recurring, which would be the case if the CATERR was due to an MSID mismatch condition. When the BMC detects that this aggregate CATERR signal has asserted, it can then go through PECI to query each CPU to determine which one was the source of the error and write an OEM code identifying the CPU slot into an event data byte in the SEL entry. If PECI is non-functional (functionality is not guaranteed in this situation), then the OEM code should indicate that the source is unknown. Event data byte 2 and byte 3 for CATERR sensor SEL events ED1 – 0xA1 ED2 - CATERR type. 0: Unknown 1: CATERR 2: CPU Core Error (not supported on Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4product family) 3: MSID Mismatch 4: CATERR due to CPU 3-strike timeout ED3 - CPU bitmap that causes the system CATERR. [0]: CPU1 [1]: CPU2 [2]: CPU3 [3]: CPU4 When a CATERR Timeout event is determined to be a CPU 3-strike timeout, The BMC shall log the logical FRU information (e.g. bus/dev/func for a PCIe* device, CPU, or DIMM) that identifies the FRU that caused the error in the extended SEL data bytes. In this case, Ext-ED0 will be set to 0x70 and the remaining ED1-ED7 will be set according to the device type and info available.
7.3.11.5 MSID Mismatch Sensor
The BMC supports a MSID Mismatch sensor for monitoring for the fault condition that will occur if there is a power rating incompatibility between a baseboard and a processor. The sensor is rearmed on power-on (AC or DC power on transitions).
7.3.12 Voltage Monitoring
The BMC provides voltage monitoring capability for voltage sources on the main board and processors such that all major areas of the system are covered. This monitoring capability is instantiated in the form of IPMI analog/threshold sensors.
Intel® Server Board S2600WT Technical Product Specification
7.3.12.1 Discrete Voltage Sensors
The discrete voltage sensor monitors multiple voltages from sensors around the baseboard and then asserts a bit in the SEL event data for each sensor that is out of range. The sensor name for the asserted bit can be retrieved via the Get Voltage Name IPMI function.
7.3.13 Fan Monitoring
BMC fan monitoring support includes monitoring of fan speed (RPM) and fan presence.
7.3.13.1 Fan Tach Sensors
Fan Tach sensors are used for fan failure detection. The reported sensor reading is proportional to the fan’s RPM. This monitoring capability is instantiated in the form of IPMI analog/threshold sensors. Most fan implementations provide for a variable speed fan, so the variations in fan speed can be large. Therefore, the threshold values must be set sufficiently low as to not result in inappropriate threshold crossings. Fan tach sensors are implemented as manual re-arm sensors because a lower-critical threshold crossing can result in full boosting of the fans. This in turn may cause a failing fan’s speed to rise above the threshold and can result in fan oscillations. As a result, fan tach sensors do not auto-rearm when the fault condition goes away but rather are rearmed for either of the following occurrences: a. The system is reset or power-cycled. b. The fan is removed and either replaced with another fan or re-inserted. This applies to hot- swappable fans only. This re-arm is triggered by change in the state of the associated fan presence sensor. After the sensor is rearmed, if the fan speed is detected to be in a normal range, the failure conditions shall be cleared and a de-assertion event shall be logged.
7.3.13.2 Fan Presence Sensors
Some chassis and server boards provide support for hot-swap fans. These fans can be removed and replaced while the system is powered on and operating normally. The BMC implements fan presence sensors for each hot swappable fan. These are instantiated as IPMI discrete sensors. Events are only logged for fan presence upon changes in the presence state after AC power is applied (no events logged for initial state).
7.3.13.3 Fan Redundancy Sensor
The BMC supports redundant fan monitoring and implements fan redundancy sensors for products that have redundant fans. Support for redundant fans is chassis-specific. A fan redundancy sensor generates events when its associated set of fans transition between redundant and non-redundant states, as determined by the number and health of the component fans. The definition of fan redundancy is configuration dependent. The BMC allows redundancy to be configured on a per fan- redundancy sensor basis through OEM SDR records. There is a fan redundancy sensor implemented for each redundant group of fans in the system. Assertion and de-assertion event generation is enabled for each redundancy state.
7.3.13.4 Power Supply Fan Sensors
Monitoring is implemented through IPMI discrete sensors, one for each power supply fan. The BMC polls each installed power supply using the PMBus* fan status commands to check for failure conditions for the
Intel® Server Board S2600WT Technical Product Specification power supply fans. The BMC asserts the “performance lags” offset of the IPMI sensor if a fan failure is detected. Power supply fan sensors are implemented as manual re-arm sensors because a failure condition can result in boosting of the fans. This in turn may cause a failing fan’s speed to rise above the “fault” threshold and can result in fan oscillations. As a result, these sensors do not auto-rearm when the fault condition goes away but rather are rearmed only when the system is reset or power-cycled, or the PSU is removed and replaced with the same or another PSU. After the sensor is rearmed, if the fan is no longer showing a failed state, the failure condition in the IPMI sensor shall be cleared and a de-assertion event shall be logged.
7.3.13.5 Monitoring for “Fans Off” Scenario
On Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family, it is likely that there will be situations where specific fans are turned off based on current system conditions. BMC Fan monitoring will comprehend this scenario and not log false failure events. The recommended method is for the BMC FW to halt updates to the value of the associated fan tach sensor and set that sensor’s IPMI sensor state to “reading-state-unavailable” when this mode is active. Management software must comprehend this state for fan tach sensors and not report these as failure conditions. The scenario for which this occurs is that the BMC Fan Speed Control (FSC) code turns off the fans by setting the PWM for the domain to 0. This is done when based on one or more global aggregate thermal margin sensor readings dropping below a specified threshold. By default the fans-off feature will be disabled. There is a BMC command and BIOS setup option to enable/disable this feature. The SmaRT/CLST system feature will also momentarily gate power to all the system fans to reduce overall system power consumption in response to a power supply event (for example, to ride out an AC power glitch). However, for this scenario, the fan power is gated by HW for only 100ms, which should not be long enough to result in triggering a fan fault SEL event.
7.3.14 Standard Fan Management
The BMC controls and monitors the system fans. Each fan is associated with a fan speed sensor that detects fan failure and may also be associated with a fan presence sensor for hot-swap support. For redundant fan configurations, the fan failure and presence status determines the fan redundancy sensor state. The system fans are divided into fan domains, each of which has a separate fan speed control signal and a separate configurable fan control policy. A fan domain can have a set of temperature and fan sensors associated with it. These are used to determine the current fan domain state. A fan domain has three states:
- The sleep and boost states have fixed (but configurable through OEM SDRs) fan speeds associated with them.
- The nominal state has a variable speed determined by the fan domain policy. An OEM SDR record is used to configure the fan domain policy. The fan domain state is controlled by several factors. They are listed below in order of precedence, high to low: Boost o Associated fan is in a critical state or missing. The SDR describes which fan domains are boosted in response to a fan failure or removal in each domain. If a fan is removed when the system is in ‘Fans-off’ mode it will not be detected and there will not be any fan boost till system comes out of ‘Fans-off; mode.
Intel® Server Board S2600WT Technical Product Specification o Any associated temperature sensor is in a critical state. The SDR describes which temperature threshold violations cause fan boost for each fan domain. o The BMC is in firmware update mode, or the operational firmware is corrupted. o If any of the above conditions apply, the fans are set to a fixed boost state speed. Nominal o A fan domain’s nominal fan speed can be configured as static (fixed value) or controlled by the state of one or more associated temperature sensors.
7.3.14.1 Hot-Swap Fans
Hot-swap fans are supported. These fans can be removed and replaced while the system is powered on and operating. The BMC implements fan presence sensors for each hot-swappable fan. When a fan is not present, the associated fan speed sensor is put into the reading/unavailable state, and any associated fan domains are put into the boost state. The fans may already be boosted due to a previous fan failure or fan removal. When a removed fan is inserted, the associated fan speed sensor is rearmed. If there are no other critical conditions causing a fan boost condition, the fan speed returns to the nominal state. Power cycling or resetting the system re-arms the fan speed sensors and clears fan failure conditions. If the failure condition is still present, the boost state returns once the sensor has re-initialized and the threshold violation is detected again.
7.3.14.2 Fan Redundancy Detection
The BMC supports redundant fan monitoring and implements a fan redundancy sensor. A fan redundancy sensor generates events when it’s associated set of fans transitions between redundant and non-redundant states, as determined by the number and health of the fans. The definition of fan redundancy is configuration dependent. The BMC allows redundancy to be configured on a per fan redundancy sensor basis through OEM SDR records. A fan failure or removal of hot-swap fans up to the number of redundant fans specified in the SDR in a fan configuration is a non-critical failure and is reflected in the front panel status. A fan failure or removal that exceeds the number of redundant fans is a non-fatal, insufficient-resources condition and is reflected in the front panel status as a non-fatal error. Redundancy is checked only when the system is in the DC-on state. Fan redundancy changes that occur when the system is DC-off or when AC is removed will not be logged until the system is turned on.
7.3.14.3 Fan Domains
System fan speeds are controlled through pulse width modulation (PWM) signals, which are driven separately for each domain by integrated PWM hardware. Fan speed is changed by adjusting the duty cycle, which is the percentage of time the signal is driven high in each pulse. The BMC controls the average duty cycle of each PWM signal through direct manipulation of the integrated PWM control registers. The same device may drive multiple PWM signals.
7.3.14.4 Nominal Fan Speed
A fan domain’s nominal fan speed can be configured as static (fixed value) or controlled by the state of one or more associated temperature sensors. OEM SDR records are used to configure which temperature sensors are associated with which fan control domains and the algorithmic relationship between the temperature and fan speed. Multiple OEM SDRs can
Intel® Server Board S2600WT Technical Product Specification reference or control the same fan control domain; and multiple OEM SDRs can reference the same temperature sensors. The PWM duty-cycle value for a domain is computed as a percentage using one or more instances of a stepwise linear algorithm and a clamp algorithm. The transition from one computed nominal fan speed (PWM value) to another is ramped over time to minimize audible transitions. The ramp rate is configurable by means of the OEM SDR. Multiple stepwise linear and clamp controls can be defined for each fan domain and used simultaneously. For each domain, the BMC uses the maximum of the domain’s stepwise linear control contributions and the sum of the domain’s clamp control contributions to compute the domain’s PWM value, except that a stepwise linear instance can be configured to provide the domain maximum. Hysteresis can be specified to minimize fan speed oscillation and to smooth fan speed transitions. If a Tcontrol SDR record does not contain a hysteresis definition, for example, an SDR adhering to a legacy format, the BMC assumes a hysteresis value of zero.
7.3.14.5 Thermal and Acoustic Management
This feature refers to enhanced fan management to keep the system optimally cooled while reducing the amount of noise generated by the system fans. Aggressive acoustics standards might require a trade-off between fan speed and system performance parameters that contribute to the cooling requirements, primarily memory bandwidth. The BIOS, BMC, and SDRs work together to provide control over how this trade-off is determined. This capability requires the BMC to access temperature sensors on the individual memory DIMMs. Additionally, closed-loop thermal throttling is only supported with DIMMs with temperature sensors.
7.3.14.6 Thermal Sensor Input to Fan Speed Control
The BMC uses various IPMI sensors as input to the fan speed control. Some of the sensors are IPMI models of actual physical sensors whereas some are “virtual” sensors whose values are derived from physical sensors using calculations and/or tabular information. The following IPMI thermal sensors are used as input to fan speed control:
- Front Panel Temperature Sensor1
- CPU Margin Sensors2,4,5
- DIMM Thermal Margin Sensors2,4
- Exit Air Temperature Sensor1, 7, 9
- PCH Temperature Sensor3,5
- On-board Ethernet Controller Temperature Sensors3, 5
- Add-In Intel SAS Module Temperature Sensors3, 5
- PSU Thermal Sensor3, 8
- CPU VR Temperature Sensors3, 6
- DIMM VR Temperature Sensors3, 6
- BMC Temperature Sensor3, 6
- Global Aggregate Thermal Margin Sensors 7
- Hot Swap Backplane Temperature Sensors
- I/O Module Temperature Sensor (With option installed)
- Intel® SAS Module (With option installed)
- Riser Card Temperature Sensors
- Intel® Xeon Phi™ coprocessor (With option installed)
- For fan speed control in Intel chassis
- Temperature margin from throttling threshold
- PECI value or margin value
- Available only when PSU has PMBus
control structure creates the resulting fan speeds. Figure 26. High-level Fan Speed Control Process used as an input to the fan speed control. overview of this management capability from a BMC perspective.
Intel® Server Board S2600WT Technical Product Specification Memory Thermal Throttling The system only supports thermal management through closed loop thermal throttling (CLTT) on system that installed with DDR4 memory with temperature sensors. Throttling levels are changed dynamically to cap throttling based on memory and system thermal conditions as determined by the system and DIMM power and thermal parameters. Support for CLTT on mixed-mode DIMM populations (that is, some installed DIMMs have valid temp sensors and some do not) is not supported. The BMC fan speed control functionality is related to the memory throttling mechanism used. The following terminology is used for the various memory throttling options:
- Static Closed Loop Thermal Throttling (Static-CLTT): CLTT control registers are configured by BIOS MRC during POST. The memory throttling is run as a closed-loop system with the DIMM temperature sensors as the control input. Otherwise, the system does not change any of the throttling control registers in the embedded memory controller during runtime.
- Dynamic Closed Loop Thermal Throttling (Dynamic-CLTT): CLTT control registers are configured by BIOS MRC during POST. The memory throttling is run as a closed-loop system with the DIMM temperature sensors as the control input. Adjustments are made to the throttling during runtime based on changes in system cooling (fan speed). Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family introduce a new type of CLTT which is referred to as Hybrid CLTT for which the Integrated Memory Controller estimates the DRAM temperature in between actual reads of the TSODs. Hybrid CLTT shall be used on all Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family that have DIMMs with thermal sensors. Therefore, the terms Dynamic-CLTT and Static-CLTT are really referring to this ‘hybrid’ mode. Note that if the IMC’s polling of the TSODs is interrupted, the temperature readings that the BMC gets from the IMC shall be these estimated values. DIMM Temperature Sensor Input to Fan Speed Control A clamp algorithm is used for controlling fan speed based on DIMM temperatures. Aggregate DIMM temperature margin sensors are used as the control input to the algorithm. Dynamic (Hybrid) CLTT The system will support dynamic (memory) CLTT for which the BMC FW dynamically modifies thermal offset registers in the IMC during runtime based on changes in system cooling (fan speed). For static CLTT, a fixed offset value is applied to the TSOD reading to get the die temperature; however this is does not provide results as accurate when the offset takes into account the current airflow over the DIMM, as is done with dynamic CLTT. In order to support this feature, the BMC FW will derive the air velocity for each fan domain based on the PWM value being driven for the domain. Since this relationship is dependent on the chassis configuration, a method must be used which supports this dependency (for example, through OEM SDR) that establishes a lookup table providing this relationship. BIOS will have an embedded lookup table that provides thermal offset values for each DIMM type and air velocity range (3 ranges of air velocity are supported). During system boot BIOS will provide 3 offset values (corresponding to the 3 air velocity ranges) to the BMC for each enabled DIMM. Using this data the BMC FW constructs a table that maps the offset value corresponding to a given air velocity range for each DIMM. During runtime the BMC applies an averaging algorithm to determine the target offset value corresponding to the current air velocity and then the BMC writes this new offset value into the IMC thermal offset register for the DIMM. Autoprofile The server board implemented autoprofile feature to improve upon previous platform configuration- dependent FSC and maintain competitive acoustics within the market. This feature is not available for third party customization.
Intel® Server Board S2600WT Technical Product Specification BIOS and BMC will handshake to automatically understand configuration details and automatically select the optimal fan speed control profile in the BMC. Customers will only select a performance or an acoustic profile selection from the BIOS menu for EPSD system and the fan speed control will be optimal for the configuration loaded. Users can still choose performance or acoustic profile in BIOS setting. Default is acoustic. Performance option is recommend if customer installed MICs or any other high power add-in cards (higher than 75W) or PCI-e add-in cards which requires excessive cooling. ASHRAE Compliance Auto-profile algorithm will be implemented for PCSD products from Grantley generation. There will be no manual selection of profiles at different altitudes, but altitude impact will be well covered by auto-profile.
7.3.14.7 Power Supply Fan Speed Control
This section describes the system level control of the fans internal to the power supply over the PMBus*. Some, but not all, Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family will require that the power supplies be included in the system level fan speed control. For any system that requires either of these capabilities, the power supply must be PMBus*-compliant. System Control of Power Supply Fans Some products require that the BMC control the speed of the power supply fans, as is done with normal system (chassis) fans, except that the BMC cannot reduce the power supply fan any lower than the internal power supply control is driving it. For these products the BMC FW must have the ability to control and monitor the power supply fans through PMBus* commands. The power supply fans are treated as a system fan domain for which fan control policies are mapped, just as for chassis system fans, with system thermal sensors (rather than internal power supply thermal sensors) used as the input to a clamp algorithm for the power supply fan control. This domain has both piecewise clipping curves and clamped sensors mapped into the power supply fan domain. All the power supplies can be defined as a single fan domain. Use of Power Supply Thermal Sensors as Input to System (Chassis) Fan Control Some products require that the power supply internal thermal sensors are used as control inputs to the system (chassis) fans, in the same manner as other system thermal sensors are used for this purpose. The power supply thermal sensors are included as clamped sensors into one or more system fan domains, which may include the power supply fan domain.
7.3.14.8 Fan Boosting due to Fan Failures
® Server Systems supporting the Intel® Xeon® processor E5-2600 v3, v4 product family introduce additional capabilities for handling fan failure or removal as described in this section. Each fan failure shall be able to define a unique response from all other fan domains. An OEM SDR table defines the response of each fan domain based on a failure of any fan, including both system and power supply fans (for PMBus*-compliant power supplies only). This means that if a system has six fans, then there will be six different fan fail reactions.
7.3.14.9 Programmable Fan PWM Offset
The system provides a BIOS Setup option to boost the system fan speed by a programmable positive offset or a “Max” setting. Setting the programmable offset causes the BMC to add the offset to the fan speeds to which it would otherwise be driving the fans. The Max setting causes the BMC to replace the domain minimum speed with alternate domain minimums that also are programmable through SDRs. This capability is offered to provide system administrators the option to manually configure fan speeds in instances where the fan speed optimized for a given platform may not be sufficient when a high end add-in adapter is configured into the system. This enables easier usage of the fan speed control to support Intel as well as third party chassis and better support of ambient temperatures higher than 35°C.
Intel® Server Board S2600WT Technical Product Specification
7.3.15 Power Management Bus (PMBus*)
The Power Management Bus (“PMBus*”) is an open standard protocol that is built upon the SMBus* 2.0 transport. It defines a means of communicating with power conversion and other devices using SMBus*- based commands. A system must have PMBus*-compliant power supplies installed in order for the BMC or ME to monitor them for status and/or power metering purposes. For more information on PMBus*, please see the System Management Interface Forum Web site http://www.powersig.org/.
7.3.16 Power Supply Dynamic Redundancy Sensor
The BMC supports redundant power subsystems and implements a Power Unit Redundancy sensor per platform. A Power Unit Redundancy sensor is of sensor type Power Unit (09h) and reading type Availability Status (0Bh). This sensor generates events when a power subsystem transitions between redundant and non-redundant states, as determined by the number and health of the power subsystem’s component power supplies. The BMC implements Dynamic Power Supply Redundancy status based upon current system load requirements as well as total Power Supply capacity. This status is independent of the Cold Redundancy status. This prevents the BMC from reporting Fully Redundant Power supplies when the load required by the system exceeds half the power capability of all power supplies installed and operational. Dynamic Redundancy detects this condition and generates the appropriate SEL event to notify the user of the condition. Power supplies of different power ratings may be swapped in and out to adjust the power capacity and the BMC will adjust the Redundancy status accordingly. The definition of redundancy is power subsystem dependent and sometimes even configuration dependent. This sensor is configured as a manual-rearm sensor in order to avoid the possibility of extraneous SEL events that could occur under certain system configuration and workload conditions. The sensor shall rearm for the following conditions:
- PSU hot-add
- system reset
- AC power cycle
- DC power cycle System AC power is applied but on standby - Power unit redundancy is based on OEM SDR power unit record and number of PSU present. System is (DC) powered on - The BMC calculates Dynamic Power Supply Redundancy status based upon current system load requirements as well as total Power Supply capacity. The BMC allows redundancy to be configured on a per power-unit-redundancy sensor basis by means of the OEM SDR records.
7.3.17 Component Fault LED Control
Several sets of component fault LEDs are supported on the server board. See Figure 3. Intel® Light Guided Diagnostics - DIMM Fault LEDs and Figure 4. Intel® Light Guided Diagnostic LED Identification. Some LEDs are owned by the BMC and some by the BIOS.
Table 24. Component Fault LEDs
- Fan fault LEDs – A fan fault LED is associated with each fan. The BMC lights a fan fault LED if the associated fan-tach sensor has a lower critical threshold event status asserted. Fan-tach sensors are manual re-arm sensors. Once the lower critical threshold is crossed, the LED remains lit until the sensor is rearmed. These sensors are rearmed at system DC power-on and system reset.
- DIMM fault LEDs – The BMC owns the hardware control for these LEDs. The LEDs reflect the state of BIOS-owned event-only sensors. When the BIOS detects a DIMM fault condition, it sends an IPMI OEM command (Set Fault Indication) to the BMC to instruct the BMC to turn on the associated DIMM Fault LED. These LEDs are only active when the system is in the ‘on’ state. The BMC will not activate or change the state of the LEDs unless instructed by the BIOS.
- Hard Disk Drive Status LEDs – The HSBP PSoC* owns the HW control for these LEDs and detection of the fault/status conditions that the LEDs reflect.
- CPU Fault LEDs. The BMC owns control for these LEDs. An LED is lit if there is an MSID mismatch (that is, CPU power rating is incompatible with the board) Note: When a system has an older version of BMC than a HSBP that is being installed, the HSBP PSOC will be downgraded to the BMC PSOC version after next AC power cycle. Intel suggest to keep the latest system update package installed.
7.3.18 NMI (Diagnostic Interrupt) Sensor
- The front panel NMI (diagnostic interrupt) button is pressed
- The BMC receives an IPMI command Chassis Control command that requests this action Note that the BMC may also generate this interrupt due to an IPMI Watchdog Timer pre-timeout interrupt; however an event for this occurrence is already logged against the Watchdog Timer sensor so it will not log an NMI sensor event.
7.3.19 LAN Leash Event Monitoring
BMC embedded LAN channels. It does not monitor the state of any optional NICs.
Intel® Server Board S2600WT Technical Product Specification The LAN Leash Lost offset asserts when one of the two BMC LAN channels loses a previously established link. It de-asserts when at least one LAN channel has a new link established after the previous assertion. No action is taken if a link has never been established. LAN Leash events do not affect the front panel system status LED.
7.3.20 Add-in Module Presence Sensor
Some server boards provide dedicated slots for add-in modules/boards (for example, SAS, IO, PCIe*-riser). For these boards the BMC provides an individual presence sensor to indicate if the module/board is installed.
7.3.21 CMOS Battery Monitoring
The BMC monitors the voltage level from the CMOS battery, which provides battery backup to the chipset Real Time Clock. This is monitored as an auto-rearm threshold sensor. Unlike monitoring of other voltage sources for which the Emulex* Pilot III component continuously cycles through each input, the voltage channel used for the battery monitoring provides a SW enable bit to allow the BMC FW to poll the battery voltage at a relatively slow rate in order to conserve battery power.
Intel® Server Board S2600WT Technical Product Specification 8. Intel® Intelligent Power Node Manager (NM) Support Overview Power management deals with requirements to manage processor power consumption and manage power at the platform level to meet critical business needs. Node Manager (NM) is a platform resident technology that enforces power capping and thermal-triggered power capping policies for the platform. These policies are applied by exploiting subsystem knobs (such as processor P and T states) that can be used to control power consumption. NM enables data center power management by exposing an external interface to management software through which platform policies can be specified. It also implements specific data center power management usage models such as power limiting, and thermal monitoring. The NM feature is implemented by a complementary architecture utilizing the ME, BMC, BIOS, and an ACPI- compliant OS. The ME provides the NM policy engine and power control/limiting functions (referred to as Node Manager or NM) while the BMC provides the external LAN link by which external management software can interact with the feature. The BIOS provides system power information utilized by the NM algorithms and also exports ACPI Source Language (ASL) code used by OS-Directed Power Management (OSPM) for negotiating processor P and T state changes for power limiting. PMBus*-compliant power supplies provide the capability to monitoring input power consumption, which is necessary to support NM. The NM architecture applicable to this generation of servers is defined by the NPTM Architecture Specification v2.0. NPTM is an evolving technology that is expected to continue to add new capabilities that will be defined in subsequent versions of the specification. The ME NM implements the NPTM policy engine and control/monitoring algorithms defined in the Node Power and Thermal Manager (NPTM) specification.
8.1 Hardware Requirements
NM is supported only on platforms that have the NM FW functionality loaded and enabled on the Management Engine (ME) in the SSB and that have a BMC present to support the external LAN interface to the ME. NM power limiting features requires a means for the ME to monitor input power consumption for the platform. This capability is generally provided by means of PMBus*-compliant power supplies although an alternative model using a simpler SMBus* power monitoring device is possible (there is potential loss in accuracy and responsiveness using non-PMBus* devices). The NM SmaRT/CLST feature does specifically require PMBus*-compliant power supplies as well as additional hardware on the baseboard.
8.2 Features
NM provides feature support for policy management, monitoring and querying, alerts and notifications, and an external interface protocol. The policy management features implement specific IT goals that can be specified as policy directives for NM. Monitoring and querying features enable tracking of power consumption. Alerts and notifications provide the foundation for automation of power management in the data center management stack. The external interface specifies the protocols that must be supported in this version of NM.
8.3 ME System Management Bus (SMBus*) interface
The ME uses the SMLink0 on the SSB in multi-master mode as a dedicated bus for communication with the BMC using the IPMB protocol. The BMC FW considers this a secondary IPMB bus and runs at 400 kHz. The ME uses the SMLink1 on the SSB in multi-master mode bus for communication with PMBus* devices in the power supplies for support of various NM-related features. This bus is shared with the BMC, which polls these PMBus* power supplies for sensor monitoring purposes (for example, power
Intel® Server Board S2600WT Technical Product Specification supply status, input power, and so on). This bus runs at 100 KHz. The Management Engine has access to the “Host SMBus*”. 8.4 PECI 3.0 The BMC owns the PECI bus for all Intel server implementations and acts as a proxy for the ME when necessary.
8.5 NM “Discovery” OEM SDR
A NM “discovery” OEM SDR must be loaded into the BMC’s SDR repository if and only if the NM feature is supported on that product. This OEM SDR is used by management software to detect if NM is supported and to understand how to communicate with it. Since PMBus* compliant power supplies are required in order to support NM, the system should be probed when the SDRs are loaded into the BMC’s SDR repository in order to determine whether or not the installed power supplies do in fact support PMBus*. If the installed power supplies are not PMBus* compliant then the NM “discovery” OEM SDR should not be loaded. Please refer to the Intel® Intelligent Power Node Manager 2.0 External Architecture Specification using IPMI for details of this interface.
8.6 SmaRT/CLST
The power supply optimization provided by SmaRT/CLST relies on a platform HW capability as well as ME FW support. When a PMBus*-compliant power supply detects insufficient input voltage, an overcurrent condition, or an over-temperature condition, it will assert the SMBAlert# signal on the power supply SMBus* (such as, the PMBus*). Through the use of external gates, this results in a momentary assertion of the PROCHOT# and MEMHOT# signals to the processors, thereby throttling the processors and memory. The ME FW also sees the SMBAlert# assertion, queries the power supplies to determine the condition causing the assertion, and applies an algorithm to either release or prolong the throttling, based on the situation. System power control modes include: 1. SmaRT: Low AC input voltage event; results in a one-time momentary throttle for each event to the maximum throttle state 2. Electrical Protection CLST: High output energy event; results in a throttling hiccup mode with fixed maximum throttle time and a fix throttle release ramp time. 3. Thermal Protection CLST: High power supply thermal event; results in a throttling hiccup mode with fixed maximum throttle time and a fix throttle release ramp time. When the SMBAlert# signal is asserted, the fans will be gated by HW for a short period (~100ms) to reduce overall power consumption. It is expected that the interruption to the fans will be of short enough duration to avoid false lower threshold crossings for the fan tach sensors; however, this may need to be comprehended by the fan monitoring FW if it does have this side-effect. ME FW will log an event into the SEL to indicate when the system has been throttled by the SmaRT/CLST power management feature. This is dependent on ME FW support for this sensor. Please reference the ME FW EPS for SEL log details.
8.6.1 Dependencies on PMBus*-compliant Power Supply Support
The SmaRT/CLST system feature depends on functionality present in the ME NM SKU. This feature requires power supplies that are compliant with the PMBus specification.
Intel® Server Board S2600WT Technical Product Specification Note: For additional information on Intel® Intelligent Power Node Manager usage and support, please visit the following Intel Website: http://www.intel.com/content/www/us/en/data-center/data-center-management/node-manager- general.html?wapkw=node+manager
- Basic and Advanced Server Management Features
optionally installed Remote Management Module 4 Lite/Lite2 (RMM4 Lite/Lite2) key. Table 25. Intel® Remote Management Module 4 (RMM4) Options Intel® RMM4 Lite is successful, then the BMC activates the advanced features. The following table identifies both Basic and Advanced server management features. Table 26. Basic and Advanced Server Management Features Overview
On the server board the Intel® RMM4 Lite/Lite2 key is installed at the following location. Figure 27. Intel® RMM4 Lite Activation Key Installation
9.1 Dedicated Management Port
without the RMM4 Lite/Lite2 key installed.
9.2 Embedded Web Server
- Microsoft Internet Explorer 9.0*
- Microsoft Internet Explorer 10.0*
- Mozilla Firefox 24*
- Mozilla Firefox 25* The embedded web user interface supports strong security (authentication, encryption, and firewall support) since it enables remote server configuration and control. The user interface presented by the embedded web user interface shall authenticate the user before allowing a web session to be initiated. Encryption using 128- bit SSL is supported. User authentication is based on user id and password. Intel® RMM4 Lite Key RJ45 – Dedicated Management Port
Intel® Server Board S2600WT Technical Product Specification The GUI presented by the embedded web server authenticates the user before allowing a web session to be initiated. It presents all functions to all users but grays out those functions that the user does not have privilege to execute. For example, if a user does not have privilege to power control, then the item shall be displayed in greyed out font in that user’s UI display. The web GUI also provides a launch point for some of the advanced features, such as KVM and media redirection. These features are grayed out in the GUI unless the system has been updated to support these advanced features. The embedded web server only displays US English or Chinese language output. Additional features supported by the web GUI include:
- Present all the Basic features to the users
- Power on/Power off/reset the server and view current power state
- Display BIOS, BMC, ME and SDR version information
- Display overall system health.
- Configuration of various IPMI over LAN parameters for both IPV4 and IPV6
- Configuration of alerting (SNMP and SMTP)
- Display system asset information for the product, board, and chassis.
- Display BMC-owned sensors (name, status, current reading, enabled thresholds), including color- code status of sensors.
- Provide ability to filter sensors based on sensor type (Voltage, Temperature, Fan and Power supply related)
- Automatic refresh of sensor data with a configurable refresh rate
- Online help
- Display/clear SEL (display is in easily understandable human readable format)
- Support major industry-standard browsers (Microsoft Internet Explorer* and Mozilla Firefox*)
- The GUI session automatically times out after a user-configurable inactivity period. By default, this inactivity period is 30 minutes.
- Embedded Platform Debug feature - Allow the user to initiate a “debug dump” to a file that can be sent to Intel ® for debug purposes.
- Virtual Front Panel. The Virtual Front Panel provides the same functionality as the local front panel. The displayed LEDs match the current state of the local panel LEDs. The displayed buttons (for example, power button) can be used in the same manner as the local buttons.
- Display of ME sensor data. Only sensors that have associated SDRs loaded will be displayed.
- Ability to save the SEL to a file
- Ability to force HTTPS connectivity for greater security. This is provided through a configuration option in the UI.
- Display of processor and memory information that is available over IPMI over LAN.
- Ability to get and set Node Manager (NM) power policies
- Display of power consumed by the server
- Ability to view and configure VLAN settings
- Warn user the reconfiguration of IP address will cause disconnect.
- Capability to block logins for a period of time after several consecutive failed login attempts. The lock-out period and the number of failed logins that initiates the lock-out period are configurable by the user.
Intel® Server Board S2600WT Technical Product Specification
- Server Power Control - Ability to force into Setup on a reset
- System POST results – The web server provides the system’s Power-On Self Test (POST) sequence for the previous two boot cycles, including timestamps. The timestamps may be displayed as a time relative to the start of POST or the previous POST code.
- Customizable ports - The web server provides the ability to customize the port numbers used for SMASH, http, https, KVM, secure KVM, remote media, and secure remote media.. For additional information, reference the Intel® Remote Management Module 4 and Integrated BMC Web Console Users Guide.
9.3 Advanced Management Feature Support (RMM4 Lite/Lite2)
The integrated baseboard management controller has support for advanced management features which are enabled when an optional Intel® Remote Management Module 4 Lite (RMM4 Lite/Lite2) is installed. The Intel RMM4 add-on offers convenient, remote KVM access and control through LAN and internet. It captures, digitizes, and compresses video and transmits it with keyboard and mouse signals to and from a remote computer. Remote access and control software runs in the integrated baseboard management controller, utilizing expanded capabilities enabled by the Intel RMM4 hardware. Key Features of the RMM4 add-on are:
- KVM redirection from either the dedicated management NIC or the server board NICs used for management traffic; up to two KVM sessions
- Media Redirection – The media redirection feature is intended to allow system administrators or users to mount a remote IDE or USB CDROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server allowing system administrators or users to install software (including operating systems), copy files, update BIOS, or boot the server from this device.
- KVM – Automatically senses video resolution for best possible screen capture, high performance mouse tracking and synchronization. It allows remote viewing and configuration in pre-boot POST and BIOS setup.
9.3.1 Keyboard, Video, Mouse (KVM) Redirection
The BMC firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This feature is available remotely from the embedded web server as a Java applet. This feature is only enabled when the Intel® RMM4 Lite is present. The client system must have a Java Runtime Environment (JRE) version 6.0 or later to run the KVM or media redirection applets. The BMC supports an embedded KVM application (Remote Console) that can be launched from the embedded web server from a remote console. USB1.1 or USB 2.0 based mouse and keyboard redirection are supported. It is also possible to use the KVM-redirection (KVM-r) session concurrently with media-redirection (media-r). This feature allows a user to interactively use the keyboard, video, and mouse (KVM) functions of the remote server as if the user were physically at the managed server. KVM redirection console supports the following keyboard layouts: English, Dutch, French, German, Italian, Russian, and Spanish. KVM redirection includes a “soft keyboard” function. The “soft keyboard” is used to simulate an entire keyboard that is connected to the remote system. The “soft keyboard” functionality supports the following layouts: English, Dutch, French, German, Italian, Russian, and Spanish. The KVM-redirection feature automatically senses video resolution for best possible screen capture and provides high-performance mouse tracking and synchronization. It allows remote viewing and configuration in pre-boot POST and BIOS setup, once BIOS has initialized video.
Intel® Server Board S2600WT Technical Product Specification 100 Other attributes of this feature include: Encryption of the redirected screen, keyboard, and mouse Compression of the redirected screen. Ability to select a mouse configuration based on the OS type. Support user definable keyboard macros. KVM redirection feature supports the following resolutions and refresh rates: 640x480 at 60Hz, 72Hz, 75Hz, 85Hz, 100Hz 800x600 at 60Hz, 72Hz, 75Hz, 85Hz 1024x768 at 60Hx, 72Hz, 75Hz, 85Hz 1280x960 at 60Hz 1280x1024 at 60Hz 1600x1200 at 60Hz 1920x1080 (1080p) 1920x1200 (WUXGA) 1650x1080 (WSXGA+)
9.3.2 Remote Console
The Remote Console is the redirected screen, keyboard and mouse of the remote host system. To use the Remote Console window of your managed host system, the browser must include a Java* Runtime Environment plug-in. If the browser has no Java support, such as with a small handheld device, the user can maintain the remote host system using the administration forms displayed by the browser. The Remote Console window is a Java Applet that establishes TCP connections to the BMC. The protocol that is run over these connections is a unique KVM protocol and not HTTP or HTTPS. This protocol uses ports #7578 for KVM, #5120 for CDROM media redirection, and #5123 for Floppy/USB media redirection. When encryption is enabled, the protocol uses ports #7582 for KVM, #5124 for CDROM media redirection, and #5127 for Floppy/USB media redirection. The local network environment must permit these connections to be made, that is, the firewall and, in case of a private internal network, the NAT (Network Address Translation) settings have to be configured accordingly.
9.3.3 Performance
The remote display accurately represents the local display. The feature adapts to changes to the video resolution of the local display and continues to work smoothly when the system transitions from graphics to text or vice-versa. The responsiveness may be slightly delayed depending on the bandwidth and latency of the network. Enabling KVM and/or media encryption will degrade performance. Enabling video compression provides the fastest response while disabling compression provides better video quality. For the best possible KVM performance, a 2Mb/sec link or higher is recommended. The redirection of KVM over IP is performed in parallel with the local KVM without affecting the local KVM operation.
9.3.4 Security
The KVM redirection feature supports multiple encryption algorithms, including RC4 and AES. The actual algorithm that is used is negotiated with the client based on the client’s capabilities.
Intel® Server Board S2600WT Technical Product Specification 101
9.3.5 Availability
The remote KVM session is available even when the server is powered off (in stand-by mode). No restart of the remote KVM session shall be required during a server reset or power on/off. An BMC reset (for example, due to an BMC Watchdog initiated reset or BMC reset after BMC FW update) will require the session to be re- established. KVM sessions persist across system reset, but not across an AC power loss.
9.3.6 Usage
As the server is powered up, the remote KVM session displays the complete BIOS boot process. The user is able interact with BIOS setup, change and save settings as well as enter and interact with option ROM configuration screens. At least two concurrent remote KVM sessions are supported. It is possible for at least two different users to connect to the same server and start remote KVM sessions
9.3.7 Force-enter BIOS Setup
KVM redirection can present an option to force-enter BIOS Setup. This enables the system to enter F2 setup while booting which is often missed by the time the remote console redirects the video.
9.3.8 Media Redirection
The embedded web server provides a Java applet to enable remote media redirection. This may be used in conjunction with the remote KVM feature, or as a standalone applet. The media redirection feature is intended to allow system administrators or users to mount a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server. Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device. The following capabilities are supported: The operation of remotely mounted devices is independent of the local devices on the server. Both remote and local devices are usable in parallel. Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the server. It is possible to boot all supported operating systems from the remotely mounted device and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See the Tested/supported Operating System List for more information. Media redirection supports redirection for both a virtual CD device and a virtual Floppy/USB device concurrently. The CD device may be either a local CD drive or else an ISO image file; the Floppy/USB device may be either a local Floppy drive, a local USB device, or else a disk image file. The media redirection feature supports multiple encryption algorithms, including RC4 and AES. The actual algorithm that is used is negotiated with the client based on the client’s capabilities. A remote media session is maintained even when the server is powered off (in standby mode). No restart of the remote media session is required during a server reset or power on/off. An BMC reset (for example, due to an BMC reset after BMC FW update) will require the session to be re-established The mounted device is visible to (and usable by) managed system’s OS and BIOS in both pre-boot and post-boot states. The mounted device shows up in the BIOS boot order and it is possible to change the BIOS boot order to boot from this remote device. It is possible to install an operating system on a bare metal server (no OS present) using the remotely mounted device. This may also require the use of KVM-r to configure the OS during install.
Intel® Server Board S2600WT Technical Product Specification 102 USB storage devices will appear as floppy disks over media redirection. This allows for the installation of Device drivers during OS installation. If either a virtual IDE or virtual floppy device is remotely attached during system boot, both the virtual IDE and virtual floppy are presented as bootable devices. It is not possible to present only a single-mounted device type to the system BIOS.
9.3.8.1 Availability
The default inactivity timeout is 30 minutes and is not user-configurable. Media redirection sessions persist across system reset but not across an AC power loss or BMC reset.
9.3.8.2 Network Port Usage
The KVM and media redirection features use the following ports: 5120 – CD Redirection 5123 – FD Redirection 5124 – CD Redirection (Secure) 5127 – FD Redirection (Secure) 7578 – Video Redirection 7582 – Video Redirection (Secure) For additional information, reference the Intel® Remote Management Module 4 and Integrated BMC Web Console Users Guide.
- On-board Connector/Header Overview
10.1 Power Connectors
The server board includes several power connectors that are used to provide DC power to various devices.
10.1.1 Main Power
on the server board. The server board provides no option to support power supplies with cable harnesses. tables provide the pin-out for both “MAIN PWR 1” and “MAIN PWR 2” connectors. Table 27. Main Power (Slot 1) Connector Pin-out (“MAIN PWR 1”)
Table 28. Main Power (Slot 2) Connector Pin-out ("MAIN PWR 2”)
10.1.2 Hot Swap Backplane Power Connector
Table 29. Hot Swap Backplane Power Connector Pin-out (“HSBP PWR")
10.1.3 Peripheral Drive Power Connector
as “Peripheral_ PWR”. The following table provides the pin-out for this connector.
Table 30. Peripheral Drive Power Connector Pin-out ("Peripheral_PWR")
10.1.4 Riser Card Supplemental 12V Power Connectors
limited by available power provided by the power supply and the total power draw of the rest of the system. is available to support any high power add-in cards. Table 31. Riser Slot Auxiliary Power Connector Pin-out ("OPT_12V_PWR”) orderable accessory kit from Intel using the following Intel product code: AXXGPGPUCABLE. Figure 28. High Power Add-in Card 12V Auxiliary Power Cable Option
10.2 Front Panel Headers and Connectors
provides a functional description and pin-out for each connector.
10.2.1 Front Panel Button and LED Support
- Standard 30-pin header “FRONT_PANEL” - SSI compatible
- Custom 30-pin high density “STORAGE_FP” – Used on storage models of Intel server systems with a rack handle mounted front panel Each connector provides an interface supporting system control buttons and LEDs. The following table identifies the supported button and LED features supported from each front panel connector.
Table 32. Front Panel Features The pinout is identical for both front panel connectors. Table 33. Front Panel Connector Pin-out ("Front Panel” and “Storage FP”)
10.2.2 Front Panel LED and Control Button Features Overview
10.2.2.1 Power/Sleep Button and LED Support
of supporting different indicator states as defined in the following table. Table 34. Power/Sleep LED Functional States
10.2.2.2 System ID Button and LED Support
using the IPMI “Chassis Identify” command which will cause the LED to blink for 15 seconds.
10.2.2.3 System Reset Button Support
10.2.2.4 NMI Button Support
cause an event to be logged in the SEL. Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action enabled. The following table describes behavior regarding NMI signal generation and event logging by the BMC. Table 35. NMI Signal Generation and Event Logging Power-off Non-ACPI Off System power is off, and the BIOS has not initialized the chipset. S0 ACPI Steady on System and the operating system are up and running.
10.2.2.5 NIC Activity LED Support
occurs at a rate that is consistent with the amount of network activity that is occurring.
10.2.2.6 Storage Device Activity LED Support
giving access to this LED for add-in controllers.
10.2.2.7 System Status LED Support
platform management sub-system. See section 12.2 for a list of supported System Status LED states. of the server board near the I/O module connector. The following table provides the connector pin-out. Note: The numbers 5 & 6 in the silk screen label identify the USB ports routed to this connector. Table 36. Front Panel USB 2.0 Connector Pin-out ("FP_USB_2.0_5-6 ")
10 TP_USB2_FP_10
the Main Power #1 connector. The following table provides the connector pin-out.
1 P5V_USB_FP
compliant USB 3.0 devices may not be supported from these ports.
10.2.5 Front Panel Video Connector
table provides the pin-out for this connector. Table 38. Front Panel Video Connector Pin-out ("FP VIDEO")
10.2.6 Intel® Local Control Panel Connector
the right edge of the server board. The following table provides the pin-out for this connector. Table 39. Intel Local Control Panel Connector Pin-out ("LCP")
10.3 On-Board Storage Option Connectors
functional overview and pin-out of each connector.
10.3.1 Single Port SATA Only Connectors
provides the pin-out for both connectors. Table 40. Single Port SATA Connector Pin-out ("SATA 4" & "SATA 5")
10.3.1.1 SATA SGPIO Connector
Table 41. SATA SGPIO Connector Pin-out ("SATA_SGPIO")
10.3.2 Internal Type-A USB Connector
Riser Slot #1. The following table provides the pin-out for this connector. Table 42. Internal Type-A USB Connector Pin-out ("USB 2.0")
10.3.3 Internal 2mm Low Profile eUSB SSD Connector
provides the pin-out for this connector. Table 43. Internal eUSB Connector Pin-out ("eUSB SSD")
10.4 System Fan Connectors
Figure 29. System Fan Connector Pin-outs location of each system fan connector on the server board. Figure 30. System Fan Connector Placement
10.5 Other Connectors and Headers
10.5.1 Chassis Intrusion Header
the server board, this header is labeled “CHAS_INTR” and is located on the right edge of the server board. The header has the following pin-out. Table 44. Chassis Intrusion Header Pin-out ("CHAS_INTR")
Chassis Intrusion offset (00h). The BMC detects chassis intrusion and logs a SEL event when the system is in the on, sleep, or standby state. Chassis intrusion is not detected when the system is in an AC power-off (AC lost) state. the chassis cover is open, and takes the appropriate actions. System fans can be set to boost to maintain proper system cooling when a chassis intrusion is detected.
10.5.2 Storage Device Activity LED Header
server board. The header has the following pin-out. Table 45. Hard Drive Activity Header Pin-out ("HDD_LED")
10.5.3 Intelligent Platform Management Bus (IPMB) Connector
connector has the following pin-out. Table 46. IPMB Connector Pin-out
10.5.4 Hot Swap Backplane I2C* Connectors
connectors have the following pin-out. **Table 47. Hot-Swap Backplane I2C* Connector Pin-out**
10.5.5 SMBus Connector
embedded server management bus. Table 48. SMBus Connector Pin-out
- Reset and Recovery Jumpers
Figure 31. Reset and Recovery Jumper Block Location The following sections describe how each jumper block is used.
11.1 BIOS Default Jumper Block
- Power down the server and unplug the power cord(s)
- Remove the system top cover and move the “BIOS DFLT” jumper from pins 1 - 2 (default) to pins 2 - 3
- Wait 5 seconds then move the jumper back to pins 1 - 2
- Re-install the system top cover
- Re-Install system power cords
Note: The system will automatically power on after AC is applied to the system.
- During POST, access the <F2> BIOS Setup utility to configure and save desired BIOS options
- 0012 System RTC date/time not set
- 5220 BIOS Settings reset to default settings
Intel® Server Board S2600WT Technical Product Specification 116 Note: also, that the system time and date may need to be reset.
11.2 Serial Port ‘A’ Configuration Jumper
See section 5.10 for details
11.3 Password Clear Jumper Block
This jumper causes both the User password and the Administrator password to be cleared if they were set. The operator should be aware that this creates a security gap until passwords have been installed again through the <F2> BIOS Setup utility. This is the only method by which the Administrator and User passwords can be cleared unconditionally. Other than this jumper, passwords can only be set or cleared by changing them explicitly in BIOS Setup or by similar means. No method of resetting BIOS configuration settings to default values will affect either the Administrator or User passwords. 1. Power down the server. For safety, unplug the power cord(s) 2. Remove the system top cover 3. Move the “Password Clear” jumper from pins 1 - 2 (default) to pins 2 - 3 (password clear position) 4. Re-install the system top cover and re-attach the power cords 5. Power up the server and access the <F2> BIOS Setup utility 6. Verify the password clear operation was successful by viewing the Error Manager screen. Two errors should be logged:
- 5221 Passwords cleared by jumper
- 5224 Password clear jumper is set 7. Exit the BIOS Setup utility and power down the server. For safety, remove the AC power cords 8. Remove the system top cover and move the “Password Clear” jumper back to pins 1 - 2 (default) 9. Re-install the system top cover and reattach the AC power cords. 10. Power up the server 11. Strongly recommended: Boot into <F2> BIOS Setup immediately, go to the Security tab and set the Administrator and User passwords if you intend to use BIOS password protection
11.4 Management Engine (ME) Firmware Force Update Jumper Block
When the ME Firmware Force Update jumper is moved from its default position, the ME is forced to operate in a reduced minimal operating capacity. This jumper should only be used if the ME firmware has gotten corrupted and requires re-installation. The following procedure should be followed. Note: System Update files are included in the System Update Packages (SUP) posted to Intel’s Download center web site. http://downloadcenter.intel.com 1. Turn off the system. 2. Remove the AC power cords Note: If the ME FRC UPD jumper is moved with AC power applied to the system, the ME will not operate properly. 3. Remove the system top cover 4. Move the “ME FRC UPD” Jumper from pins 1 - 2 (default) to pins 2 - 3 (Force Update position) 5. Re-install the system top cover and re-attach the AC power cords 6. Power on the system 7. Boot to the EFI shell 8. Change directories to the folder containing the update files
Intel® Server Board S2600WT Technical Product Specification 117 9. Update the ME firmware using the following command: iflash32 /u /ni <version#>_ME.cap 10. When the update has successfully completed, power off the system 11. Remove the AC power cords 12. Remove the system top cover 13. Move the “ME FRC UPD” jumper back to pins 1-2 (default) 14. Re-attach the AC power cords 15. Power on system
11.5 BMC Force Update Jumper Block
The BMC Force Update jumper is used to put the BMC in Boot Recovery mode for a low-level update. It causes the BMC to abort its normal boot process and stay in the boot loader without executing any Linux code. This jumper should only be used if the BMC firmware has gotten corrupted and requires re-installation. The following procedure should be followed: Note: System Update files are included in the System Update Packages (SUP) posted to Intel’s Download center web site. http://downloadcenter.intel.com 1. Turn off the system. 2. Remove the AC power cords Note: If the BMC FRC UPD jumper is moved with AC power applied to the system, the BMC will not operate properly. 3. Remove the system top cover 4. Move the “BMC FRC UPD” Jumper from pins 1 - 2 (default) to pins 2 - 3 (Force Update position) 5. Re-install the system top cover and re-attach the AC power cords 6. Power on the system 7. Boot to the EFI shell 8. Change directories to the folder containing the update files 9. Update the BMC firmware using the following command: FWPIAUPD -u -bin -ni -b -o -pia -if=usb <file name.BIN> 10. When the update has successfully completed, power off the system 11. Remove the AC power cords 12. Remove the system top cover 13. Move the “BMC FRC UPD” jumper back to pins 1-2 (default) 14. Re-attach the AC power cords 15. Power on system 16. Boot to the EFI shell 17. Change directories to the folder containing the update files 18. Re-install the board/system SDR data by running the FRUSDR utility 19. After the SDRs have been loaded, reboot the server
Intel® Server Board S2600WT Technical Product Specification 118
11.6 BIOS Recovery Jumper
When the BIOS Recovery jumper block is moved from its default pin position (pins 1-2), the system will boot using a backup BIOS image to the uEFI shell, where a standard BIOS update can be performed. See the BIOS update instructions that are included with System Update Packages (SUP) downloaded from Intel’s download center web site. This jumper is used when the system BIOS has become corrupted and is non- functional, requiring a new BIOS image to be loaded on to the server board. Note: The BIOS Recovery jumper is ONLY used to re-install a BIOS image in the event the BIOS has become corrupted. This jumper is NOT used when the BIOS is operating normally and you need to update the BIOS from one version to another. The following procedure should be followed. Note: System Update Packages (SUP) can be downloaded from Intel’s download center web site. http://downloadcenter.intel.com 1. Turn off the system. 2. For safety, remove the AC power cords 3. Remove the system top cover 4. Move the “BIOS Recovery” jumper from pins 1 - 2 (default) to pins 2 - 3 (BIOS Recovery position) 5. Re-install the system top cover and re-attach the AC power cords 6. Power on the system 7. The system will automatically boot to the EFI shell. Update the BIOS using the standard BIOS update instructions provided with the system update package 8. After the BIOS update has successfully completed, power off the system. For safety, remove the AC power cords from the system 9. Remove the system top cover 10. Move the BIOS Recovery jumper back to pins 1-2 (default) 11. Re-install the system top cover and re-attach the AC power cords 12. Power on the system and access the <F2> BIOS Setup utility. 13. Configure desired BIOS settings 14. Hit the <F10> key to save and exit the utility. Note: Warning When Upgrading to BIOS R0009 this will upgrade both the Primary and Backup BIOS due to new security features added in this BIOS, going to previous BIOS Below R0009 is not recommended and may cause board fault. Note: If a BIOS image was flashed with a BIOS .cap file that was customized using Intel® Integrator Tool Kit (ITK), the user must to run the command run ‘iflash32 -ccs' to clear ITK customization settings and get loaded defaults. After reboot the to BIOS setup user needs to press “F9’ to load default settings. This cealning feature Only is available in the iflash32 V13.1 build 8 which was integrated in the R016 SUP and later SUPs.
- Light Guided Diagnostics
The server board includes several on-board LED indicators to aid troubleshooting various board level faults. The following diagram shows the location for each LED. Figure 32. On-Board Diagnostic LED Placement
Figure 33. DIMM Fault LED Placement
12.1 System ID LED
among many other similar servers. There are two options available for illuminating the System ID LED.
- The front panel ID LED Button is pushed, which causes the LED to illuminate to a solid on state until
- An IPMI “Chassis Identify” command is remotely entered, which causes the LED to blink
The System ID LED on the server board is tied directly to the System ID LED on system front panel if present.
12.2 System Status LED
server. Possible LED states include solid green, blinking green, blinking amber, and solid amber. and retains the sensor and front panel status LED state established before the power-down event. errors, the status LED will change to solid green.
Table 49. System Status LED State Definitions Not ready • System is powered off (AC and/or DC).
- System is in EuP Lot6 Off Mode.
- System is in S5 Soft-Off State. Green Solid on Ok Indicates that the System is running (in S0 State) and its status is ‘Healthy’. The system is not exhibiting any errors. AC power is present and BMC has booted and manageability functionality is up and running. After a BMC reset, and in conjuction with the Chassis ID solid ON, the BMC is booting Linux*. Control has been passed from BMC uBoot to BMC Linux* itself. It will be in this state for ~10-~20 seconds Green ~1 Hz blink Degraded - system is operating in a degraded state although still functional, or system is operating in a redundant state but with an impending failure warning System degraded:
- Redundancy loss such as power-supply or fan. Applies only if the associated platform sub-system has redundancy capabilities.
- Fan warning or failure when the number of fully operational fans is less than minimum number needed to cool the system.
- Non-critical threshold crossed – Temperature (including HSBP temp), voltage, input power to power supply, output current for main power rail from power supply and Processor Thermal Control (Therm Ctrl) sensors.
- Power supply predictive failure occurred while redundant power supply configuration was present.
- Unable to use all of the installed memory (more than 1 DIMM installed).
- Correctable Errors over a threshold and migrating to a spare DIMM (memory sparing). This indicates that the system no longer has spared DIMMs (a redundancy lost condition). Corresponding DIMM LED lit.
- In mirrored configuration, when memory mirroring takes place and system loses memory redundancy.
- Battery failure.
- BMC executing in uBoot. (Indicated by Chassis ID blinking at 3Hz). System in degraded state (no manageability). BMC uBoot is running but has not transferred control to BMC Linux*. Server will be in this state 6-8 seconds after BMC reset while it pulls the Linux* image into flash.
- BMC Watchdog has reset the BMC.
- Power Unit sensor offset for configuration error is asserted.
- HDD HSC is off-line or degraded.
- Hard drive fault
Intel® Server Board S2600WT Technical Product Specification 122 Color State Criticality Description Amber ~1 Hz blink Non-critical - System is operating in a degraded state with an impending failure warning, although still functioning Non-fatal alarm – system is likely to fail:
- Critical threshold crossed – Voltage, temperature (including HSBP temp), input power to power supply, output current for main power rail from power supply and PROCHOT (Therm Ctrl) sensors.
- VRD Hot asserted.
- Minimum number of fans to cool the system not present or failed
- Hard drive fault
- Power Unit Redundancy sensor – Insufficient resources offset (indicates not enough power supplies present)
- In non-sparing and non-mirroring mode if the threshold of correctable errors is crossed within the window Amber Solid on Critical, non- recoverable – System is halted Fatal alarm – system has failed or shutdown:
- CPU CATERR signal asserted
- MSID mismatch detected (CATERR also asserts for this case).
- CPU 1 is missing
- CPU Thermal Trip
- No power good – power fault
- DIMM failure when there is only 1 DIMM present and hence no good memory present.
- Runtime memory uncorrectable error in non-redundant mode.
- DIMM Thermal Trip or equivalent
- SSB Thermal Trip or equivalent
- CPU ERR2 signal asserted
- BMC/Video memory test failed. (Chassis ID shows blue/solid-on for this condition)
- Both uBoot BMC FW images are bad. (Chassis ID shows blue/solid-on for this condition)
- 240VA fault
- Fatal Error in processor initialization: o Processor family not identical o Processor model not identical o Processor core/thread counts not identical o Processor cache size not identical o Unable to synchronize processor frequency o Unable to synchronize QPI link frequency
- Uncorrectable memory error in a non-redundant mode
12.3 BMC Boot/Reset Status LED Indicators
Table 50. BMC Boot/Reset Status LED Indicators information on replacing this motherboard. information on replacing this motherboard. while it pulls the Linux image into flash. will be in this state for ~10-~20 seconds. End of BMC boot/reset process. up and running. Fault/Status LEDs operate as per usual.
12.4 Post Code Diagnostic LEDs
12.5 Fan Fault LEDs
12.6 Memory Fault LEDs
BMC will not activate or change the state of the LEDs unless instructed by the BIOS.
Intel® Server Board S2600WT Technical Product Specification 124
12.7 CPU Fault LEDs
The server board includes a CPU fault LED for each CPU socket. The CPU Fault LED is lit if there is an MSID mismatch error is detected (that is, CPU power rating is incompatible with the board).
- Power Supply Specification Guidelines
platform with stable operating power requirements. supply for custom server platform designs that utilize the server board detailed in this document.
13.1 Power Supply DC Output Connector
card connector 10035388-102LF). Table 51. Power Supply DC Power Output Connector Pinout
13.2 Power Supply DC Output Specification
13.2.1 Output Power/Currents
static and dynamic voltage regulation requirements for all conditions. Table 52. Minimum Load Ratings
- 12Vstby must provide 4.0A with two power supplies in parallel. The Fan may start to work when stby
- Peak combined power for all outputs shall not exceed 850W.
- Length of time peak power can be supported is based on thermal sensor and assertion of the
SMBAlert# signal at maximum operating temperature.
13.2.2 Standby Output
13.2.3 Voltage Regulation
measured at the output connectors. Table 53. Voltage Regulation Limits
13.2.4 Dynamic Loading
occur anywhere within the MIN load to the MAX load conditions. Table 54. Transient Load Requirements Note: For dynamic condition +12V MIN loading is 1A.
13.2.5 Capacitive Loading
The power supply shall be stable and meet all requirements with the following capacitive loading ranges. Table 55. Capacitive Loading Conditions
13.2.6 Grounding
should be well designed to ensure passing the max allowed Common Mode Noise levels. connected to protective earth ground. Resistance of the ground returns to chassis shall not exceed 1.0 mΩ. This path may be used to carry DC current.
13.2.7 Closed loop stability
required. Closed-loop stability must be ensured at the maximum and minimum loads as applicable.
13.2.8 Residual Voltage Immunity in Standby mode
simultaneously. It also should not trip the protection circuits during turn on. voltage is applied and the PSON# signal is de-asserted.
13.2.9 Common Mode Noise
13.2.10 Soft Starting
overstress of the AC line or any power supply components at any specified AC line or load conditions.
13.2.11 Zero Load Stability Requirements
power subsystem is subsequently loaded, it must begin to regulate and source current without fault.
13.2.12 Hot Swap Requirements
13.2.13 Forced Load Sharing
supplies must be able to load share in parallel and operate in a hot-swap/redundant 1+1 configurations. redundant power supply does not cause these outputs to go out of regulation in the system.
13.2.14 Ripple/Noise
capacitor in parallel with a 0.1µF ceramic capacitor is placed at the point of measurement. Table 56. Ripples and Noise
13.2.15 Timing Requirements
Table 57. Timing Requirements voltages being within regulation. limits to PWOK asserted at turn on. voltages dropping out of regulation limits. being in regulation at AC turn on. regulation after loss of AC.
Figure 34. Turn On/Off Timing (Power Supply Signals)
Intel® Server Board S2600WT TPS 130 Appendix A. Integration and Usage Tips When adding or removing components or peripherals from the server board, power cords must be disconnected from the server. With power applied to the server, standby voltages are still present even though the server board is powered off. This server board supports the Intel® Xeon® Processor E5-2600 v3, v4 product family with a Thermal Design Power (TDP) of up to and including 145 Watts. Previous generations of the Intel® Xeon® processors are not supported. Server systems using this server board may or may not meet the TDP design limits of the server board. Validate the TDP limits of the server system before selecting a processor. Processors must be installed in order. CPU 1 must be populated for the server board to operate The bottom add-in card slot of the 2U 3-slot riser card and Riser Card Slots #2 and #3 on the server board can only be used in dual processor configurations The riser card slots are specifically designed to support riser cards only. Attempting to install a PCIe* add-in card directly into a riser card slot on the server board may damage the server board, the add-in card, or both. This server board only supports DDR4 ECC RDIMM – Registered (Buffered) DIMMS and DDR4 ECC LRDIMM – Load Reduced DIMMs For the best performance, the number of DDR4 DIMMs installed should be balanced across both processor sockets and memory channels On the back edge of the server board are eight diagnostic LEDs that display a sequence of amber POST codes during the boot process. If the server board hangs during POST, the LEDs display the last POST event run before the hang. The System Status LED will be set to a steady Amber color for all Fatal Errors that are detected during processor initialization. A steady Amber System Status LED indicates that an unrecoverable system failure condition has occurred RAID partitions created using either RSTe or ESRT2 cannot span across the two embedded SATA controllers. Only drives attached to a common SATA controller can be included in a RAID partition
Intel® Server Board S2600WT Technical Product Specification 131 Appendix B. Integrated BMC Sensor Tables This appendix provides BMC core sensor information common to all Intel server boards within this generation of product. Specific server boards and/or server platforms may only implement a sub-set of sensors and/or may include additional sensors. The actual sensor name associated with a sensor number may vary between server boards or systems. Sensor Type The Sensor Type values are the values enumerated in the Sensor Type Codes table in the IPMI specification. The Sensor Type provides the context in which to interpret the sensor, such as the physical entity or characteristic that is represented by this sensor. Event/Reading Type The Event/Reading Type values are from the Event/Reading Type Code Ranges and Generic Event/Reading Type Codes tables in the IPMI specification. Digital sensors are a specific type of discrete sensor, which have only two states. Event Offset/Triggers Event Thresholds are event-generating thresholds for threshold types of sensors. - [u,l][nr,c,nc]: upper non-recoverable, upper critical, upper non-critical, lower non-recoverable, lower critical, lower non-critical - uc, lc: upper critical, lower critical Event Triggers are supported event-generating offsets for discrete type sensors. The offsets can be found in the Generic Event/Reading Type Codes or Sensor Type Codes tables in the IPMI specification, depending on whether the sensor event/reading type is generic or a sensor-specific response. Assertion/De-assertion Enables Assertion and de-assertion indicators reveal the type of events the sensor generates: - As: Assertions - De: De-assertion Readable Value/Offsets - Readable Value indicates the type of value returned for threshold and other non-discrete type sensors. - Readable Offsets indicate the offsets for discrete sensors that are readable with the Get Sensor Reading command. Unless otherwise indicated, all event triggers are readable; Readable Offsets consist of the reading type offsets that do not generate events. Event Data Event data is the data that is included in an event message generated by the sensor. For threshold- based sensors, the following abbreviations are used: - R: Reading value - T: Threshold value
Intel® Server Board S2600WT Technical Product Specification 132 Rearm Sensors The rearm is a request for the event status for a sensor to be rechecked and updated upon a transition between good and bad states. Rearming the sensors can be done manually or automatically. This column indicates the type supported by the sensor. The following abbreviations are used to describe a sensor: - A: Auto-rearm - M: Manual rearm Default Hysteresis The hysteresis setting applies to all thresholds of the sensor. This column provides the count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis). Criticality Criticality is a classification of the severity and nature of the condition. It also controls the behavior of the Control Panel Status LED. Standby Some sensors operate on standby power. These sensors may be accessed and/or generate events when the main (system) power is off, but AC power is present.
Table 58. BMC Core Sensors
Intel® Server Board S2600WT Technical Product Specification 134 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by 03 - Power cycle 08 - Timer interrupt Physical Security (Physical Scrty) 04h Chassis Intrusion is chassis- specific Physical Security 05h Sensor Specific 6Fh 00 - Chassis intrusion Degraded OK As and De – Trig Offset A X 04 - LAN leash lost FP Interrupt (FP NMI Diag Int) 05h Chassis - specific Critical Interrupt 13h Sensor Specific 6Fh 00 - Front panel NMI/diagnostic interrupt OK As – Trig Offset A – SMI Timeout (SMI Timeout) 06h All SMI Timeout F3h Digital Discrete 03h 01 – State asserted Fatal As and De – Trig Offset A – System Event Log (System Event Log) 07h All Event Logging Disabled 10h Sensor Specific 6Fh 02 - Log area reset/cleared OK As – Trig Offset A X System Event (System Event) 08h All System Event 12h Sensor Specific 6Fh 04 – PEF action OK As - Trig Offset A X Button Sensor (Button) 09h All Button/Switch 14h Sensor Specific 6Fh 00 – Power Button 02 – Reset Button OK AS _ Trig Offset A X BMC Watchdog 0Ah All Mgmt System Health 28h Digital Discrete 03h 01 – State Asserted Degraded As – Trig Offset A - Voltage Regulator Watchdog (VR Watchdog) 0Bh All Voltage 02h Digital Discrete 03h 01 – State Asserted Fatal As and De – Trig Offset M X Fan Redundancy (Fan Redundancy) 0Ch Chassis- specific Fan 04h Generic 0Bh 00 - Fully redundant OK As and De – Trig Offset A – 01 - Redundancy lost Degraded 02 - Redundancy degraded Degraded
Intel® Server Board S2600WT Technical Product Specification 135 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by 03 - Non-redundant: Sufficient resources. Transition from redundant Degraded 04 - Non-redundant: Sufficient resources. Transition from insufficient. Degraded 05 - Non-redundant: insufficient resources. Non-Fatal 06 – Non-Redundant: degraded from fully redundant. Degraded 07 - Redundant degraded from non- redundant Degraded SSB Thermal Trip (SSB Therm Trip) 0Dh All Temperature 01h Digital Discrete 03h 01 – State Asserted Fatal As and De – Trig Offset M X IO Module Presence (IO Mod Presence) 0Eh Platform- specific Module/Board 15h Digital Discrete 08h 01 – Inserted/Present OK As and De – Trig Offset M - SAS Module Presence (SAS Mod Presence) 0Fh Platform- specific Module/Board 15h Digital Discrete 08h 01 – Inserted/Present OK As and De – Trig Offset M X BMC Firmware Health (BMC FW Health) 10h All Mgmt Health 28h Sensor Specific 6Fh 04 – Sensor Failure Degraded As - Trig Offset A X System Airflow (System Airflow) 11h All Other Units 0Bh Threshold 01h FW Update Status 12h All Version Change 2Bh OEM defined 70h 00h – Update started 01h – Update completed successfully. 02h – Update failure OK As _ Trig Offset A _
Intel® Server Board S2600WT Technical Product Specification 136 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by IO Module2 Presence (IO Mod2 Presence) 13h Platform- specific Module/Board 15h Digital Discrete 08h 01 – Inserted/Present OK As and De – Trig Offset M - Baseboard Temperature 5 (Platform Specific) 14h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Baseboard Temperature 6 (Platform Specific) 15h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X IO Module2 Temperature (I/O Mod2 Temp) 16h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X PCI Riser 3 Temperature (PCI Riser 3 Temp) 17h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X PCI Riser 4 Temperature (PCI Riser 4 Temp) 18h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Baseboard +1.05V Processor3 Vccp (BB +1.05Vccp P3) 19h Platform- specific Voltage 02h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Baseboard +1.05V Processor4 Vccp (BB +1.05Vccp P4) 1Ah Platform- specific Voltage 02h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Baseboard Temperature 1 (Platform Specific) 20h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Front Panel Temperature (Front Panel Temp) 21h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X SSB Temperature (SSB Temp) 22h All Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X
Intel® Server Board S2600WT Technical Product Specification 137 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by Baseboard Temperature 2 (Platform Specific) 23h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Baseboard Temperature 3 (Platform Specific) 24h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Baseboard Temperature 4 (Platform Specific) 25h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X IO Module Temperature (I/O Mod Temp) 26h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X PCI Riser 1 Temperature (PCI Riser 1 Temp) 27h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X IO Riser Temperature (IO Riser Temp) 28h Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Hot-swap Backplane 1 Temperature (HSBP 1 Temp) 29h Chassis- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Hot-swap Backplane 2 Temperature (HSBP 2 Temp) 2Ah Chassis- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Hot-swap Backplane 3 Temperature (HSBP 3 Temp) 2Bh Chassis- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X PCI Riser 2 Temperature (PCI Riser 2 Temp) 2Ch Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X SAS Module Temperature (SAS Mod Temp) 2Dh Platform- specific Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X
Intel® Server Board S2600WT Technical Product Specification 138 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by Exit Air Temperature (Exit Air Temp) 2Eh Chassis and Platform Specific Temperature 01h Threshold 01h This sensor does not generate any events. nc = Degraded c = Non-fatal As and De Analog R, T A X Network Interface Controller Temperature (LAN NIC Temp) 2Fh All Temperature 01h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Fan Tachometer Sensors (Chassis specific sensor names) 30h– 3Fh Chassis and Platform Specific Fan 04h Threshold 01h [l] [c,nc] nc = Degraded c = Non- fatalNote3 As and De Analog R, T M - Fan Present Sensors (Fan x Present) 40h– 4Fh Chassis and Platform Specific Fan 04h Generic 08h 01 - Device inserted OK As and De - Triggered Offset Auto - Power Supply 1 Status (PS1 Status) 50h Chassis- specific Power Supply 08h Sensor Specific 6Fh 00 - Presence OK As and De – Trig Offset A X 01 - Failure Degraded 02 – Predictive Failure Degraded 03 - A/C lost Degraded 06 – Configuration error OK Power Supply 2 Status (PS2 Status) 51h Chassis- specific Power Supply 08h Sensor Specific 6Fh 00 - Presence OK As and De – Trig Offset A X 01 - Failure Degraded 02 – Predictive Failure Degraded 03 - A/C lost Degraded 06 – Configuration error OK Power Supply 1 AC Power Input (PS1 Power In) 54h Chassis- specific Other Units 0Bh Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Power Supply 2 AC Power Input (PS2 Power In) 55h Chassis- specific Other Units 0Bh Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X
Intel® Server Board S2600WT Technical Product Specification 139 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by Power Supply 1 +12V % of Maximum Current Output (PS1 Curr Out %) 58h Chassis- specific Current 03h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Power Supply 2 +12V % of Maximum Current Output (PS2 Curr Out %) 59h Chassis- specific Current 03h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Power Supply 1 Temperature (PS1 Temperature) 5Ch Chassis- specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Power Supply 2 Temperature (PS2 Temperature) 5Dh Chassis- specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A X Hard Disk Drive 15 - 23 Status (HDD 15 - 23 Status) 60h 68h Chassis- specific Drive Slot 0Dh Sensor Specific 6Fh 00 - Drive Presence OK As and De – Trig Offset A X X 01- Drive Fault Degraded 07 - Rebuild/Remap in progress Degraded Processor 1 Status (P1 Status) 70h All Processor 07h Sensor Specific 6Fh 01 - Thermal trip Fatal As and De – Trig Offset M X 07 - Presence OK Processor 2 Status (P2 Status) 71h All Processor 07h Sensor Specific 6Fh 01 - Thermal trip Fatal As and De – Trig Offset M X 07 - Presence OK Processor 3 Status (P3 Status) 72h Platform- specific Processor 07h Sensor Specific 6Fh 01 - Thermal trip Fatal As and De – Trig Offset M X 07 - Presence OK Processor 4 Status (P4 Status) 73h Platform- specific Processor 07h Sensor Specific 6Fh 01 - Thermal trip Fatal As and De – Trig Offset M X 07 - Presence OK Processor 1 Thermal Margin (P1 Therm Margin) 74h All Temperature 01h Threshold 01h - - - Analog R, T A – Processor 2 Thermal Margin (P2 Therm Margin) 75h All Temperature 01h Threshold 01h - - - Analog R, T A – Processor 3 Thermal Margin (P3 Therm Margin) 76h Platform- specific Temperature 01h Threshold 01h - - - Analog R, T A –
Intel® Server Board S2600WT Technical Product Specification 140 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by Processor 4 Thermal Margin (P4 Therm Margin) 77h Platform- specific Temperature 01h Threshold 01h - - - Analog R, T A – Processor 1 Thermal Control % (P1 Therm Ctrl %) 78h All Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog Trig Offset A – Processor 2 Thermal Control % (P2 Therm Ctrl %) 79h All Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog Trig Offset A – Processor 3 Thermal Control % (P3 Therm Ctrl %) 7Ah Platform- specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog Trig Offset A – Processor 4 Thermal Control % (P4 Therm Ctrl %) 7Bh Platform- specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog Trig Offset A – Processor ERR2 Timeout (CPU ERR2) 7Ch All Processor 07h Digital Discrete 03h 01 – State Asserted Fatal As and De – Trig Offset A – Catastrophic Error (CATERR) 80h All Processor 07h Digital Discrete 03h 01 – State Asserted Fatal As and De – Trig Offset M – MTM Level Change (MTM Lvl Change) 81h All Mgmt Health 28h Digital Discrete 03h 01 – State Asserted - As and De – Trig Offset A - Processor Population Fault (CPU Missing) 82h All Processor 07h Digital Discrete 03h 01 – State Asserted Fatal As and De – Trig Offset M – Processor 1 DTS Thermal Margin (P1 DTS Therm Mgn) 83h All Temperature 01h Threshold 01h - - - Analog R, T A – Processor 2 DTS Thermal Margin (P2 DTS Therm Mgn) 84h All Temperature 01h Threshold 01h - - - Analog R, T A – Processor 3 DTS Thermal Margin (P3 DTS Therm Mgn) 85h Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A –
Intel® Server Board S2600WT Technical Product Specification 141 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by Processor 4 DTS Thermal Margin (P4 DTS Therm Mgn) 86h Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Auto Config Status (AutoCfg Status) 87h All Mgmt Health 28h Digital Discrete 03h 01 – State Asserted - As and De – Trig Offset A - Processor 1 VRD Temperature (VRD Hot) 90h All Temperature 01h Digital Discrete 05h 01 - Limit exceeded Non-fatal As and De – Trig Offset A – Power Supply 1 Fan Tachometer 1 (PS1 Fan Tach 1) A0h Chassis- specific Fan 04h Generic – digital discrete 03h 01 – State Asserted Non-fatal As and De - Trig Offset A - Power Supply 1 Fan Tachometer 2 (PS1 Fan Tach 2) A1h Chassis- specific Fan 04h Generic – digital discrete 03h 01 – State Asserted Non-fatal As and De - Trig Offset A - MIC 1 Status (GPGPU1 Status) A2h Platform Specific Status C0h OEM Defined 70h - - - - - - - MIC 2 Status (GPGPU2 Status) A3h Platform Specific Status C0h OEM Defined 70h - - - - - - - Power Supply 2 Fan Tachometer 1 (PS2 Fan Tach 1) A4h Chassis- specific Fan 04h Generic – digital discrete 03h 01 – State Asserted Non-fatal As and De - Trig Offset M - Power Supply 2 Fan Tachometer 2 (PS2 Fan Tach 2) A5h Chassis- specific Fan 04h Generic – digital discrete 03h 01 – State Asserted Non-fatal As and De - Trig Offset M - MIC 3 Status (GPGPU3 Status) A6h Platform Specific Status C0h OEM Defined 70h - - - - - - -
Intel® Server Board S2600WT Technical Product Specification 142 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by MIC 4 Status (GPGPU4 Status) A7h Platform Specific Status C0h OEM Defined 70h - - - - - - - Processor 1 DIMM Aggregate Thermal Margin 1 (P1 DIMM Thrm Mrgn1) B0h All Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Processor 1 DIMM Aggregate Thermal Margin 2 (P1 DIMM Thrm Mrgn2) B1h All Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Processor 2 DIMM Aggregate Thermal Margin 1 (P2 DIMM Thrm Mrgn1) B2h All Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Processor 2 DIMM Aggregate Thermal Margin 2 (P2 DIMM Thrm Mrgn2) B3h All Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Processor 3 DIMM Aggregate Thermal Margin 1 (P3 DIMM Thrm Mrgn1) B4h Platform Specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Processor 3 DIMM Aggregate Thermal Margin 2 (P3 DIMM Thrm Mrgn2) B5h Platform Specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Processor 4 DIMM Aggregate Thermal Margin 1 (P4 DIMM Thrm Mrgn1) B6h Platform Specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Processor 4 DIMM Aggregate Thermal Margin 2 (P4 DIMM Thrm Mrgn2) B7h Platform Specific Temperature 01h Threshold 01h [u] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Node Auto-Shutdown Sensor (Auto Shutdown) B8h Multi- Node Specific Power Unit 09h Generic – digital discrete 03h 01 – State Asserted Non-fatal As and De - Trig Offset A - Fan Tachometer Sensors (Chassis specific sensor names) BAh– BFh Chassis and Platform Specific Fan 04h Threshold 01h [l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T M -
Intel® Server Board S2600WT Technical Product Specification 143 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by Processor 1 DIMM Thermal Trip (P1 Mem Thrm Trip) C0h All Memory 0Ch Sensor Specific 6Fh 0A- Critical overtemperature Fatal As and De – Trig Offset M - Processor 2 DIMM Thermal Trip (P2 Mem Thrm Trip) C1h All Memory 0Ch Sensor Specific 6Fh 0A- Critical overtemperature Fatal As and De – Trig Offset M - Processor 3 DIMM Thermal Trip (P3 Mem Thrm Trip) C2h Platform Specific Memory 0Ch Sensor Specific 6Fh 0A- Critical overtemperature Fatal As and De – Trig Offset M X Processor 4 DIMM Thermal Trip (P4 Mem Thrm Trip) C3h Platform Specific Memory 0Ch Sensor Specific 6Fh 0A- Critical overtemperature Fatal As and De – Trig Offset M X MIC 1 Temp (GPGPU1 Core Temp) C4h Platform Specific Temperature 01h Threshold 01h - - - - - - - MIC 2 Temp (GPGPU2 Core Temp) C5h Platform Specific Temperature 01h Threshold 01h - - - - - - - MIC 3 Temp (GPGPU3 Core Temp) C6h Platform Specific Temperature 01h Threshold 01h - - - - - - - MIC 4 Temp (GPGPU4 Core Temp) C7h Platform Specific Temperature 01h Threshold 01h - - - - - - - Global Aggregate Temperature Margin 1 (Agg Therm Mrgn 1) C8h Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Global Aggregate Temperature Margin 2 (Agg Therm Mrgn 2) C9h Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Global Aggregate Temperature Margin 3 (Agg Therm Mrgn 3) CAh Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Global Aggregate Temperature Margin 4 (Agg Therm Mrgn 4) CBh Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A –
Intel® Server Board S2600WT Technical Product Specification 144 Full Sensor Name (Sensor name in SDR) Sensor Platform Applicabil ity Sensor Type Event/Rea ding Type Event Offset Triggers Contrib. To System Status Assert /De- assert Readabl e Value/ Offsets Event Data Rearm Stand- by Global Aggregate Temperature Margin 5 (Agg Therm Mrgn 5) CCh Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Global Aggregate Temperature Margin 6 (Agg Therm Mrgn 6) CDh Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Global Aggregate Temperature Margin 7 (Agg Therm Mrgn 7) CEh Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Global Aggregate Temperature Margin 8 (Agg Therm Mrgn 8) CFh Platform Specific Temperature 01h Threshold 01h - - - Analog R, T A – Baseboard +12V (BB +12.0V) D0h All Voltage 02h Threshold 01h [u,l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Voltage Fault (Voltage Fault) D1h All Voltage 02h Discrete 03h 01 – Asserted - - - - A - Baseboard CMOS Battery (BB +3.3V Vbat) DEh All Voltage 02h Threshold 01h [l] [c,nc] nc = Degraded c = Non-fatal As and De Analog R, T A – Hard Disk Drive 0 -14 Status (HDD 0 - 14 Status) F0h FEh Chassis- specific Drive Slot 0Dh Sensor Specific 6Fh 00 - Drive Presence OK As and De – Trig Offset A X 01- Drive Fault Degraded 07 - Rebuild/Remap in progress Degraded
Table 59. Server Platform Services Firmware Health Event =1 - Image execution failed. Recovery Image loaded because operational image is corrupted. This may be either caused by Flash device corruption or failed upgrade procedure. procedure must be started again. Repair action: The Flash device must be replaced. Repair action: The Flash device must be replaced (if error is persistent). =4 – Internal error. Error during firmware execution.
Table 60. Node Manager Health Event
the back edge of the server board. run prior to the error occurring, helping to isolate the possible cause of the hang condition. Figure 35. POST Diagnostic LED Location Table 61. POST Progress Code LED Example
Intel® Server Board S2600WT Technical Product Specification 148 Early POST Memory Initialization MRC Diagnostic Codes Memory Initialization at the beginning of POST includes multiple functions, including: discovery, channel training, validation that the DIMM population is acceptable and functional, initialization of the IMC and other hardware settings, and initialization of applicable RAS configurations. The MRC Progress Codes are displayed to the Diagnostic LEDs that show the execution point in the MRC operational path at each step. Table 62. MRC Progress Codes 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h MRC Progress Codes B0h 1 0 1 1 0 0 0 0 Detect DIMM population B1h 1 0 1 1 0 0 0 1 Set DDR4 frequency B2h 1 0 1 1 0 0 1 0 Gather remaining SPD data 0xB3 1 0 1 1 0 0 1 1 Program registers on the memory controller level 0xB4 1 0 1 1 0 1 0 0 Evaluate RAS modes and save rank information 0xB5 1 0 1 1 0 1 0 1 Program registers on the channel level 0xB6 1 0 1 1 0 1 1 0 Perform the JEDEC defined initialization sequence 0xB7 1 0 1 1 0 1 1 1 Train DDR4 ranks 0x01 0 0 0 0 0 0 0 1 0x02 0 0 0 0 0 0 1 0 0x03 0 0 0 0 0 0 1 1 0x04 0 0 0 0 0 1 0 0 0x05 0 0 0 0 0 1 0 1 0xB8 1 0 1 1 1 0 0 0 Initialize CLTT/OLTT 0xB9 1 0 1 1 1 0 0 1 Hardware memory test and init 0xBA 1 0 1 1 1 0 1 0 Execute software memory init 0xBB 1 0 1 1 1 0 1 1 Program memory map and interleaving 0xBC 1 0 1 1 1 1 0 0 Program RAS configuration 0xBF 1 0 1 1 1 1 1 1 MRC is done Should a major memory initialization error occur, preventing the system from booting with data integrity, a beep code is generated, the MRC will display a fatal error code on the diagnostic LEDs, and a system halt command is executed. Fatal MRC error halts do NOT change the state of the System Status LED, and they do NOT get logged as SEL events. The following table lists all MRC fatal errors that are displayed to the Diagnostic LEDs. NOTE: Fatal MRC errors will display POST error codes that may be the same as BIOS POST progress codes displayed later in the POST process. The fatal MRC codes can be distinguished from the BIOS POST progress codes by the accompanying memory failure beep code of 3 long beeps as identified in Table 59.
Intel® Server Board S2600WT Technical Product Specification 149 Table 63. MRC Fatal Error Codes 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h MRC Fatal Error Codes E8h 1 1 1 0 1 0 0 0 No usable memory error 01h = No memory was detected from SPD read, or invalid config that causes no operable memory. 02h = Memory DIMMs on all channels of all sockets are disabled due to hardware memtest error. 03h = No memory installed. All channels are disabled. E9h 1 1 1 0 1 0 0 1 Memory is locked by Intel Trusted Execution Technology and is inaccessible EAh 1 1 1 0 1 0 1 0 DDR3 channel training error 01h = Error on read DQ/DQS (Data/Data Strobe) init 02h = Error on Receive Enable 03h = Error on Write Leveling 04h = Error on write DQ/DQS (Data/Data Strobe EBh 1 1 1 0 1 0 1 1 Memory test failure 01h = Software memtest failure. 02h = Hardware memtest failed. 03h = Hardware Memtest failure in Lockstep Channel mode requiring a channel to be disabled. This is a fatal error which requires a reset and calling MRC with a different RAS mode to retry. EDh 1 1 1 0 1 1 0 1 DIMM configuration population error 01h = Different DIMM types (UDIMM, RDIMM, LRDIMM) are detected installed in the system. 02h = Violation of DIMM population rules. 03h = The 3rd DIMM slot cannot be populated when QR DIMMs are installed. 04h = UDIMMs are not supported in the 3rd DIMM slot. 05h = Unsupported DIMM Voltage. EFh 1 1 1 0 1 1 1 1 Indicates a CLTT table structure error
Intel® Server Board S2600WT Technical Product Specification 150 BIOS POST Progress Codes The following table provides a list of all POST progress codes. Table 64. POST Progress Codes 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h SEC Phase 01h 0 0 0 0 0 0 0 1 First POST code after CPU reset 02h 0 0 0 0 0 0 1 0 Microcode load begin 03h 0 0 0 0 0 0 1 1 CRAM initialization begin 04h 0 0 0 0 0 1 0 0 PEI Cache When Disabled 05h 0 0 0 0 0 1 0 1 SEC Core At Power On Begin. 06h 0 0 0 0 0 1 1 0 Early CPU initialization during Sec Phase. 07h 0 0 0 0 0 1 1 1 Early SB initialization during Sec Phase. 08h 0 0 0 0 1 0 0 0 Early NB initialization during Sec Phase. 09h 0 0 0 0 1 0 0 1 End Of SEC Phase. 0Eh 0 0 0 0 1 1 1 0 Microcode Not Found. 0Fh 0 0 0 0 1 1 1 1 Microcode Not Loaded. PEI Phase 10h 0 0 0 1 0 0 0 0 PEI Core 11h 0 0 0 1 0 0 0 1 CPU PEIM 15h 0 0 0 1 0 1 0 1 NB PEIM 19h 0 0 0 1 1 0 0 1 SB PEIM MRC Process Codes – MRC Progress Code Sequence is executed - See Table 61. MRC Progress Codes PEI Phase continued… 31h 0 0 1 1 0 0 0 1 Memory Installed 32h 0 0 1 1 0 0 1 0 CPU PEIM (CPU Init) 33h 0 0 1 1 0 0 1 1 CPU PEIM (Cache Init) DXE Phase 60h 0 1 1 0 0 0 0 0 DXE Core started 61h 0 1 1 0 0 0 0 1 DXE NVRAM Init 62h 0 1 1 0 0 0 1 0 SB RUN Init 63h 0 1 1 0 0 0 1 1 DXE CPU Init 68h 0 1 1 0 1 0 0 0 DXE PCI Host Bridge Init 69h 0 1 1 0 1 0 0 1 DXE NB Init 6Ah 0 1 1 0 1 0 1 0 DXE NB SMM Init 70h 0 1 1 1 0 0 0 0 DXE SB Init 71h 0 1 1 1 0 0 0 1 DXE SB SMM Init 72h 0 1 1 1 0 0 1 0 DXE SB devices Init 78h 0 1 1 1 1 0 0 0 DXE ACPI Init 79h 0 1 1 1 1 0 0 1 DXE CSM Init 80h 1 0 0 0 0 0 0 0 DXE BDS Started 81h 1 0 0 0 0 0 0 1 DXE BDS connect drivers
Intel® Server Board S2600WT Technical Product Specification 151 Checkpoint Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h 82h 1 0 0 0 0 0 1 0 DXE PCI Bus begin 83h 1 0 0 0 0 0 1 1 DXE PCI Bus HPC Init 84h 1 0 0 0 0 1 0 0 DXE PCI Bus enumeration 85h 1 0 0 0 0 1 0 1 DXE PCI Bus resource requested 86h 1 0 0 0 0 1 1 0 DXE PCI Bus assign resource 87h 1 0 0 0 0 1 1 1 DXE CON_OUT connect 88h 1 0 0 0 0 0 0 0 DXE CON_IN connect 89h 1 0 0 0 1 0 0 0 DXE SIO Init 8Ah 1 0 0 0 1 0 1 0 DXE USB start 8Bh 1 0 0 0 1 0 1 1 DXE USB reset 8Ch 1 0 0 0 1 1 0 0 DXE USB detect 8Dh 1 0 0 0 1 1 0 1 DXE USB enable 91h 1 0 0 1 0 0 0 1 DXE IDE begin 92h 1 0 0 1 0 0 1 0 DXE IDE reset 93h 1 0 0 1 0 0 1 1 DXE IDE detect 94h 1 0 0 1 0 1 0 0 DXE IDE enable 95h 1 0 0 1 0 1 0 1 DXE SCSI begin 96h 1 0 0 1 0 1 1 0 DXE SCSI reset 97h 1 0 0 1 0 1 1 1 DXE SCSI detect 98h 1 0 0 1 1 0 0 0 DXE SCSI enable 99h 1 0 0 1 1 0 0 1 DXE verifying SETUP password 9Bh 1 0 0 1 1 0 1 1 DXE SETUP start 9Ch 1 0 0 1 1 1 0 0 DXE SETUP input wait 9Dh 1 0 0 1 1 1 0 1 DXE Ready to Boot 9Eh 1 0 0 1 1 1 1 0 DXE Legacy Boot 9Fh 1 0 0 1 1 1 1 1 DXE Exit Boot Services A1h 1 0 1 0 0 0 0 1 Collect info such as SBSP, Boot Mode, Reset type etc A3h 1 0 1 0 0 0 1 1 Setup minimum path between SBSP & other sockets A7h 1 0 1 0 0 1 1 1 Topology discovery and route calculation A8h 1 0 1 0 1 0 0 0 Program final route A9h 1 0 1 0 1 0 0 1 Program final IO SAD setting AAh 1 0 1 0 1 0 1 0 Protocol layer and other uncore settings ABh 1 0 1 0 1 0 1 1 Transition links to full speed operation ACh 1 0 1 0 1 1 0 0 Phy layer setting ADh 1 0 1 0 1 1 0 1 Link layer settings AEh 1 0 1 0 1 1 1 0 Coherency settings AFh 1 0 1 0 1 1 1 1 QPI initialization done B0h 1 0 1 1 0 0 0 0 RT Set Virtual Address Map Begin B1h 1 0 1 1 0 0 0 1 RT Set Virtual Address Map End B2h 1 0 1 1 0 0 1 0 DXE Legacy Option ROM init B3h 1 0 1 1 0 0 1 1 DXE Reset system
Intel® Server Board S2600WT Technical Product Specification 152 Checkpoint Diagnostic LED Decoder 1 = LED On, 0 = LED Off Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h B4h 1 0 1 1 0 1 0 0 DXE USB Hot plug B5h 1 0 1 1 0 1 0 1 DXE PCI BUS Hot plug B6h 1 0 1 1 0 1 1 0 DXE NVRAM cleanup B7h 1 0 1 1 0 1 1 1 DXE Configuration Reset C0h 1 1 0 0 0 0 0 0 RT Set Virtual Address Map Begin C2h 1 1 0 0 0 0 0 1 DXE Legacy Option ROM init C3h 1 1 0 0 0 0 1 0 DXE Reset system C4h 1 1 0 0 0 0 1 1 DXE USB Hot plug C5h 1 1 0 0 0 0 0 0 DXE PCI BUS Hot plug C6h 1 1 0 0 0 1 1 0 DXE NVRAM cleanup C7h 1 1 0 0 0 1 1 1 DXE ACPI Enable 00h 0 0 0 0 0 0 0 0 Clear POST Code S3 Resume 40h 0 1 0 0 0 0 0 0 S3 Resume PEIM (S3 started) 41h 0 1 0 0 0 0 0 1 S3 Resume PEIM (S3 boot script) 42h 0 1 0 0 0 0 2 0 S3 Resume PEIM (S3 Video Repost) 43h 0 1 0 0 0 0 1 1 S3 Resume PEIM (S3 OS wake) BIOS Recovery 46h 0 1 0 0 0 1 1 0 PEIM which detected forced Recovery condition 47h 0 1 0 0 0 1 1 1 PEIM which detected User Recovery condition 48h 0 1 0 0 1 0 0 0 Recovery PEIM (Recovery started) 49h 0 1 0 0 1 0 0 1 Recovery PEIM (Capsule found) 4Ah 0 1 0 0 1 0 1 0 Recovery PEIM (Capsule loaded) BIOS Recovery F0h 1 1 1 1 0 0 0 0 PEIM which detected forced Recovery condition
System Management applications, including Remote and Out of Band (OOB) management. initialization of processors and memory, and they are handed by a Diagnostic LED display with a system halt. unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error. display the error code on the Error Manager screen. Fatal: The system halts during POST at a blank screen with the text “Unrecoverable fatal error found. option setting in the BIOS setup does not have any effect with this class of error. resolved. The user needs to replace the faulty part and restart the system. Table 65. POST Error Codes and Messages
0012 System RTC date/time not set Major
0048 Password check failed Major
0140 PCI component encountered a PERR error Major
0141 PCI resource conflict Major
0146 PCI out of resources error Major
0191 Processor core/thread count mismatch detected Fatal
0192 Processor cache size mismatch detected Fatal
0194 Processor family mismatch detected Fatal
0195 Processor Intel(R) QPI link frequencies unable to synchronize Fatal
0196 Processor model mismatch detected Fatal
0197 Processor frequencies unable to synchronize Fatal
5220 BIOS Settings reset to default settings Major
Intel® Server Board S2600WT Technical Product Specification 154 Error Code Error Message Response
5221 Passwords cleared by jumper Major
5224 Password clear jumper is set Major
8130 Processor 01 disabled Major
8131 Processor 02 disabled Major
8160 Processor 01 unable to apply microcode update Major
8161 Processor 02 unable to apply microcode update Major
8170 Processor 01 failed Self Test (BIST) Major
8171 Processor 02 failed Self Test (BIST) Major
8180 Processor 01 microcode update not found Minor
8181 Processor 02 microcode update not found Minor
8190 Watchdog timer failed on last boot Major
8198 OS boot watchdog timer failure Major
8300 Baseboard management controller failed Self Test Major
8305 Hot Swap Controller failure Major
83A0 Management Engine (ME) failed Self Test Major 83A1 Management Engine (ME) failed to respond. Major 84F2 Baseboard management controller failed to respond Major 84F3 Baseboard management controller in update mode Major 84F4 Sensor data record empty Major 84FF System event log full Minor
8500 Memory component could not be configured in the selected RAS mode Major
8501 DIMM Population Error Major
8520 DIMM_A1 failed test/initialization Major
8521 DIMM_A2 failed test/initialization Major
8522 DIMM_A3 failed test/initialization Major
8523 DIMM_B1 failed test/initialization Major
8524 DIMM_B2 failed test/initialization Major
8525 DIMM_B3 failed test/initialization Major
8526 DIMM_C1 failed test/initialization Major
8527 DIMM_C2 failed test/initialization Major
8528 DIMM_C3 failed test/initialization Major
8529 DIMM_D1 failed test/initialization Major
852A DIMM_D2 failed test/initialization Major 852B DIMM_D3 failed test/initialization Major 852C DIMM_E1 failed test/initialization Major 852D DIMM_E2 failed test/initialization Major 852E DIMM_E3 failed test/initialization Major 852F DIMM_F1 failed test/initialization Major
8530 DIMM_F2 failed test/initialization Major
8531 DIMM_F3 failed test/initialization Major
8532 DIMM_G1 failed test/initialization Major
8533 DIMM_G2 failed test/initialization Major
8534 DIMM_G3 failed test/initialization Major
8535 DIMM_H1 failed test/initialization Major
8536 DIMM_H2 failed test/initialization Major
Intel® Server Board S2600WT Technical Product Specification 155 Error Code Error Message Response
8537 DIMM_H3 failed test/initialization Major
8538 DIMM_J1 failed test/initialization Major
8539 DIMM_J2 failed test/initialization Major
853A DIMM_J3 failed test/initialization Major 853B DIMM_K1 failed test/initialization Major 853C DIMM_K2 failed test/initialization Major 853D DIMM_K3 failed test/initialization Major 853E DIMM_L1 failed test/initialization Major 853F (Go to 85C0) DIMM_L2 failed test/initialization Major
8540 DIMM_A1 disabled Major
8541 DIMM_A2 disabled Major
8542 DIMM_A3 disabled Major
8543 DIMM_B1 disabled Major
8544 DIMM_B2 disabled Major
8545 DIMM_B3 disabled Major
8546 DIMM_C1 disabled Major
8547 DIMM_C2 disabled Major
8548 DIMM_C3 disabled Major
8549 DIMM_D1 disabled Major
854A DIMM_D2 disabled Major 854B DIMM_D3 disabled Major 854C DIMM_E1 disabled Major 854D DIMM_E2 disabled Major 854E DIMM_E3 disabled Major 854F DIMM_F1 disabled Major
8550 DIMM_F2 disabled Major
8551 DIMM_F3 disabled Major
8552 DIMM_G1 disabled Major
8553 DIMM_G2 disabled Major
8554 DIMM_G3 disabled Major
8555 DIMM_H1 disabled Major
8556 DIMM_H2 disabled Major
8557 DIMM_H3 disabled Major
8558 DIMM_J1 disabled Major
8559 DIMM_J2 disabled Major
855A DIMM_J3 disabled Major 855B DIMM_K1 disabled Major 855C DIMM_K2 disabled Major 855D DIMM_K3 disabled Major 855E DIMM_L1 disabled Major 855F (Go to 85D0) DIMM_L2 disabled Major
8560 DIMM_A1 encountered a Serial Presence Detection (SPD) failure Major
8561 DIMM_A2 encountered a Serial Presence Detection (SPD) failure Major
8562 DIMM_A3 encountered a Serial Presence Detection (SPD) failure Major
Intel® Server Board S2600WT Technical Product Specification 156 Error Code Error Message Response
8563 DIMM_B1 encountered a Serial Presence Detection (SPD) failure Major
8564 DIMM_B2 encountered a Serial Presence Detection (SPD) failure Major
8565 DIMM_B3 encountered a Serial Presence Detection (SPD) failure Major
8566 DIMM_C1 encountered a Serial Presence Detection (SPD) failure Major
8567 DIMM_C2 encountered a Serial Presence Detection (SPD) failure Major
8568 DIMM_C3 encountered a Serial Presence Detection (SPD) failure Major
8569 DIMM_D1 encountered a Serial Presence Detection (SPD) failure Major
856A DIMM_D2 encountered a Serial Presence Detection (SPD) failure Major 856B DIMM_D3 encountered a Serial Presence Detection (SPD) failure Major 856C DIMM_E1 encountered a Serial Presence Detection (SPD) failure Major 856D DIMM_E2 encountered a Serial Presence Detection (SPD) failure Major 856E DIMM_E3 encountered a Serial Presence Detection (SPD) failure Major 856F DIMM_F1 encountered a Serial Presence Detection (SPD) failure Major
8570 DIMM_F2 encountered a Serial Presence Detection (SPD) failure Major
8571 DIMM_F3 encountered a Serial Presence Detection (SPD) failure Major
8572 DIMM_G1 encountered a Serial Presence Detection (SPD) failure Major
8573 DIMM_G2 encountered a Serial Presence Detection (SPD) failure Major
8574 DIMM_G3 encountered a Serial Presence Detection (SPD) failure Major
8575 DIMM_H1 encountered a Serial Presence Detection (SPD) failure Major
8576 DIMM_H2 encountered a Serial Presence Detection (SPD) failure Major
8577 DIMM_H3 encountered a Serial Presence Detection (SPD) failure Major
8578 DIMM_J1 encountered a Serial Presence Detection (SPD) failure Major
8579 DIMM_J2 encountered a Serial Presence Detection (SPD) failure Major
857A DIMM_J3 encountered a Serial Presence Detection (SPD) failure Major 857B DIMM_K1 encountered a Serial Presence Detection (SPD) failure Major 857C DIMM_K2 encountered a Serial Presence Detection (SPD) failure Major 857D DIMM_K3 encountered a Serial Presence Detection (SPD) failure Major 857E DIMM_L1 encountered a Serial Presence Detection (SPD) failure Major 857F (Go to 85E0) DIMM_L2 encountered a Serial Presence Detection (SPD) failure Major 85C0 DIMM_L3 failed test/initialization Major 85C1 DIMM_M1 failed test/initialization Major 85C2 DIMM_M2 failed test/initialization Major 85C3 DIMM_M3 failed test/initialization Major 85C4 DIMM_N1 failed test/initialization Major 85C5 DIMM_N2 failed test/initialization Major 85C6 DIMM_N3 failed test/initialization Major 85C7 DIMM_P1 failed test/initialization Major 85C8 DIMM_P2 failed test/initialization Major 85C9 DIMM_P3 failed test/initialization Major 85CA DIMM_R1 failed test/initialization Major 85CB DIMM_R2 failed test/initialization Major 85CC DIMM_R3 failed test/initialization Major 85CD DIMM_T1 failed test/initialization Major 85CE DIMM_T2 failed test/initialization Major 85CF DIMM_T3 failed test/initialization Major
Intel® Server Board S2600WT Technical Product Specification 157 Error Code Error Message Response 85D0 DIMM_L3 disabled Major 85D1 DIMM_M1 disabled Major 85D2 DIMM_M2 disabled Major 85D3 DIMM_M3 disabled Major 85D4 DIMM_N1 disabled Major 85D5 DIMM_N2 disabled Major 85D6 DIMM_N3 disabled Major 85D7 DIMM_P1 disabled Major 85D8 DIMM_P2 disabled Major 85D9 DIMM_P3 disabled Major 85DA DIMM_R1 disabled Major 85DB DIMM_R2 disabled Major 85DC DIMM_R3 disabled Major 85DD DIMM_T1 disabled Major 85DE DIMM_T2 disabled Major 85DF DIMM_T3 disabled Major 85E0 DIMM_L3 encountered a Serial Presence Detection (SPD) failure Major 85E1 DIMM_M1 encountered a Serial Presence Detection (SPD) failure Major 85E2 DIMM_M2 encountered a Serial Presence Detection (SPD) failure Major 85E3 DIMM_M3 encountered a Serial Presence Detection (SPD) failure Major 85E4 DIMM_N1 encountered a Serial Presence Detection (SPD) failure Major 85E5 DIMM_N2 encountered a Serial Presence Detection (SPD) failure Major 85E6 DIMM_N3 encountered a Serial Presence Detection (SPD) failure Major 85E7 DIMM_P1 encountered a Serial Presence Detection (SPD) failure Major 85E8 DIMM_P2 encountered a Serial Presence Detection (SPD) failure Major 85E9 DIMM_P3 encountered a Serial Presence Detection (SPD) failure Major 85EA DIMM_R1 encountered a Serial Presence Detection (SPD) failure Major 85EB DIMM_R2 encountered a Serial Presence Detection (SPD) failure Major 85EC DIMM_R3 encountered a Serial Presence Detection (SPD) failure Major 85ED DIMM_T1 encountered a Serial Presence Detection (SPD) failure Major 85EE DIMM_T2 encountered a Serial Presence Detection (SPD) failure Major 85EF DIMM_T3 encountered a Serial Presence Detection (SPD) failure Major
8604 POST Reclaim of non-critical NVRAM variables Minor
8605 BIOS Settings are corrupted Major
8606 NVRAM variable space was corrupted and has been reinitialized Major
Recovery boot has been initiated. Note: The Primary BIOS image may be corrupted or the system may hang during POST. A BIOS update is required. Fatal 92A3 Serial port component was not detected Major 92A9 Serial port component encountered a resource conflict error Major A000 TPM device not detected. Minor A001 TPM device missing or not responding. Minor A002 TPM device failure. Minor A003 TPM device failed self test. Minor A100 BIOS ACM Error Major A421 PCI component encountered a SERR error Fatal
Table 66. POST Error Beep Codes
1 USB device action N/A Short beep sounded whenever USB device is discovered in
POST, or inserted or removed during runtime. detected a potential violation of system security.
3 Memory error Multiple System halted because a fatal error related to the memory
family/core/cache mismatch was detected. The following Beep Codes are sounded during BIOS Recovery. 2 Recovery started N/A Recovery boot has been initiated. recovery is initiated that it sounds like a 2-4 beep code. each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Table 67. Integrated BMC Beep Codes CPU1 must be populated before CPU2. board that has incompatible power capabilities.
Intel® Server Board S2600WT Technical Product Specification 159 Appendix F. Statement of Volatility The following table is used to identify the volatile and non-volatile memory components of the Intel® Server Board S2600WT (Intel Product Codes S2600WTTR & S2600WT2R) server board assembly. Component Type Size Board Location User Data Name Non-Volatile 128Mbit U4F1 No(BIOS) BIOS Flash Non-Volatile 128Mbit U2D2 No(FW) BMC Flash Non-Volatile 16Mbit U5L2 No
10 GB NIC EEPROM
(S2600WTTR) Non-Volatile 256K bit U5L3 No 1 GB NIC EEPROM (S2600WT2R) Non-Volatile N/A U1E1 No CPLD Non-Volatile N/A U1C1 No IPLD Volatile 128 MB U1D2 No BMC SDRAM Note: The previous table does not identify volatile and non-volatile memory components for devices which may be installed onto or may be used with the server board. These may include: system boards used inside a server system, processors, memory, storage devices, or add-in cards. The table provides the following data for each identified component. Component Type Three types of memory components are used on the server board assembly. These include: Non-volatile: Non-volatile memory is persistent, and is not cleared when power is removed from the system. Non-Volatile memory must be erased to clear data. The exact method of clearing these areas varies by the specific component. Some areas are required for normal operation of the server, and clearing these areas may render the server board inoperable. Volatile: Volatile memory is cleared automatically when power is removed from the system. Battery powered RAM: Battery powered RAM is similar to volatile memory, but is powered by a battery on the server board. Data in Battery powered Ram is persistent until the battery is removed from the server board. Size The size of each component includes sizes in bits, Kbits, bytes, kilobytes (KB) or megabytes (MB). Board Location The physical location of each component is specified in the Board Location column. The board location information corresponds to information on the server board silkscreen. User Data The flash components on the server boards do not store user data from the operating system. No operating system level data is retained in any listed components after AC power is removed. The persistence of information written to each component is determined by its type as described in the table.
Intel® Server Board S2600WT Technical Product Specification 160 Each component stores data specific to its function. Some components may contain passwords that provide access to that device’s configuration or functionality. These passwords are specific to the device and are unique and unrelated to operating system passwords. The specific components that may contain password data are: BIOS: The server board BIOS provides the capability to prevent unauthorized users from configuring BIOS settings when a BIOS password is set. This password is stored in BIOS flash, and is only used to set BIOS configuration access restrictions. BMC: The server boards support an Intelligent Platform Management Interface (IPMI) 2.0 conformant baseboard management controller (BMC). The BMC provides health monitoring, alerting and remote power control capabilities for the Intel® server board. The BMC does not have access to operating system level data. The BMC supports the capability for remote software to connect over the network and perform health monitoring and power control. This access can be configured to require authentication by a password. If configured, the BMC will maintain user passwords to control this access. These passwords are stored in the BMC flash.
Figure 36. Intel® Server System R1000WT Table 68. Intel® Server System R1000WT Product Family Feature Set
- Intel® Server Board S2600WT w/Dual 10GbE ports – S2600WTTR Processor Support
- Two LGA2011-3 (Socket R3) processor sockets
- Support for one or two Intel® Xeon® processors E5-2600 v3, v4 product family
- Maximum supported Thermal Design Power (TDP) of up to 145 W.
Intel® Server Board S2600WT Technical Product Specification 162 Feature Description Memory
- 24 DIMM slots – 3 DIMMs/Channel – 4 memory channels per processor
- Registered DDR4 (RDIMM), Load Reduced DDR4 (LRDIMM)
- Memory data transfer rates Intel® Xeon® processors E5-2600 v3: o DDR4 RDIMM: 1600 MT/s (3DPC), 1866 MT/s (2DPC), 2133 MT/s (2DPC) and 2400 MT/s (1DPC) o DDR4 LRDIMM: 1866 Mt/s (3DPC), 2400 MT/s (2DPC) o DDR4 LRDIMM3DS: 1866 Mt/s (3DPC), 2400 MT/s (2DPC) o NVDIMM: 2133 Mt/s (1DPC)
- Memory data transfer rates Intel® Xeon® processors E5-2600 v4: o DDR4 RDIMM: 1600 MT/s (3DPC), 2133 MT/s (2DPC) and 2400 MT/s (1DPC) o DDR4 LRDIMM: 1866 Mt/s (3DPC), 2400 MT/s (1DPC/2DPC) o DDR4 LRDIMM3DS: 1866 Mt/s (3DPC), 2400 MT/s (1DPC/2DPC) o NVDIMM: 2133 Mt/s (1DPC)
- DDR4 standard I/O voltage of 1.2V Chipset Intel® C612 chipset External I/O connections
- DB-15 Video connectors o Front and Back on non-storage systems o Back only on storage systems (12 x 3.5” and 24 x 2.5” drive support)
- RJ-45 Serial Port A connector
- Dual RJ-45 Network Interface connectors supporting either : o 10 GbE RJ-45 connectors (Intel Server Board Product Code – S2600WTTR) or o 1 GbE RJ-45 connectors (Intel Server Board Product Code – S2600WT2R)
- Dedicated RJ-45 server management port
- Three USB 2.0 / 3.0 connectors on back panel
- Two USB 2.0 / 3.0 ports on front panel (non-storage models only) Internal I/O connectors / headers
- One Type-A USB 2.0 connector
- One 2x5 pin connector providing front panel support for two USB 2.0 ports
- One 2x10 pin connector providing front panel support for two USB 2.0 / 3.0 ports
- One 2x15 pin SSI-EEB compliant front panel header
- One 2x7 pin Front Panel Video connector
- One 1x7 pin header for optional Intel® Local Control Panel (LCP) support
- One DH-10 Serial Port B connector I/O Module Accessory Options The server board includes a proprietary on-board connector allowing for the installation of a variety of available I/O modules. An installed I/O module can be supported in addition to standard on-board features and add-in PCIe* cards.
- AXX4P1GBPWLIOM – Quad port RJ45 1 GbE based on Intel® Ethernet Controller I350
- TBD – Dual port RJ-45 10GBase-T I/O Module based on Intel® Ethernet Controller x540
- AXX10GBNIAIOM – Dual port SFP+ 10 GbE module based on Intel® 82599 10 GbE controller
- AXX1FDRIBIOM – Single port QSFP FDR 56 GT/S speed InfiniBand* module
- AXX2FDRIBIOM – Dual port QSFP FDR 56 GT/S speed infiniband* module
- AXX1P40FRTIOM – Single port QSFP+ 40 GbE module
- AXX2P40FRTIOM – Dual port QSFP+ 40 GbE module System Fans
- Six dual rotor managed system fans
- One power supply fan for each installed power supply module Riser Card Support Concurrent support for two PCIe* riser cards. Each riser card slot has support for the following riser card options:
- Single add-in card slot – PCIe* x16, x16 mechanical
Intel® Server Board S2600WT Technical Product Specification 163 Feature Description Video
- Integrated 2D Video Controller
- 16 MB DDR3 Memory On-board storage controllers and options
- 10 x SATA 6Gbps ports (6Gb/s, 3 Gb/s and 1.5Gb/s transfer rates are supported)
- Two single port SATA connectors capable of supporting up to 6 Gb/sec
- Two 4-port mini-SAS HD (SFF-8643) connectors capable of supporting up to 6 Gb/sec SATA
- One eUSB 2x5 pin connector to support 2mm low-profile eUSB solid state devices
- Optional SAS IOC/ROC support via on-board Intel® Integrated RAID module connector
- Embedded Software SATA RAID o Intel® Rapid Storage RAID Technology (RSTe) 4.0 o Intel® Embedded Server RAID Technology 2 (ESRT2) with optional RAID 5 key support Security • Intel® Trusted Platform Module (TPM) - AXXTPME5 (v1.2), AXXTPME6 (v2.0) and AXXTPME7 (v2.0) (Accessory Option) Server Management
- Integrated Baseboard Management Controller, IPMI 2.0 compliant
- Support for Intel® Server Management Software
- On-board RJ45 management port
- Advanced Server Management via an Intel® Remote Management Module 4 Lite (Accessory Option) Power Supply Options The server system can have up to two power supply modules installed, providing support for the following power configurations: 1+0, 1+1 Redundant Power, and 2+0 Combined Power Three power supply options:
- AC 750W Platinum
- DC 750W Gold
- AC 1100W Platinum Storage Options 12Gb/sec Hot Swap Backplane Options:
- 8x – 2.5” SATA/SAS
- 4x - 2.5” SATA/SAS + 4x - 2.5” PCIe NVM Express* (Not Hot Swappable)
- 4x – 3.5” SATA/SAS Storage Bay Options:
- 4x – 3.5” SATA/SAS Hot Swap Hard Drive Bays + Optical Drive support
- 8x – 2.5” SATA/SAS Hot Swap Hard Drive Bays + Optical Drive support (capable)
- 4x - 2.5” SATA/SAS + 4x - 2.5” PCIe* SSD Supported Rack Mount Kit Accessory Options
- AXXPRAIL – Tool-less rack mount rail kit – 800mm max travel length
- AXXELVRAIL – Enhanced value rack mount rail kit - 424mm max travel length
- AXX1U2UCMA – Cable Management Arm – (*supported with AXXPRAIL only)
- AXX2POSTBRCKT – 2-post fixed mount bracket kit
Figure 37. Intel® Server System R2000WT Table 69. Intel® Server System R2000WT Product Family Feature Set
- Intel® Server Board S2600WT w/Dual 1GbE ports – S2600WT2R
- Intel® Server Board S2600WT w/Dual 10GbE ports – S2600WTTR Processor Support
- Two LGA2011-3 (Socket R3) processor sockets
- Support for one or two Intel® Xeon® processors E5-2600 v3, v4 product family
- Maximum supported Thermal Design Power (TDP) of up to 145 W. Memory
- 24 DIMM slots – 3 DIMMs/Channel – 4 memory channels per processor
- Registered DDR4 (RDIMM), Load Reduced DDR4 (LRDIMM)
- Memory data transfer rates Intel® Xeon® processors E5-2600 v3: o DDR4 RDIMM: 1600 MT/s (3DPC), 1866 MT/s (2DPC), 2133 MT/s (2DPC) and 2400 MT/s (1DPC) o DDR4 LRDIMM: 1866 Mt/s (3DPC), 2400 MT/s (2DPC) o DDR4 LRDIMM3DS: 1866 Mt/s (3DPC), 2400 MT/s (2DPC) o NVDIMM: 2133 Mt/s (1DPC)
- Memory data transfer rates Intel® Xeon® processors E5-2600 v4: o DDR4 RDIMM: 1600 MT/s (3DPC), 2133 MT/s (2DPC) and 2400 MT/s (1DPC) o DDR4 LRDIMM: 1866 Mt/s (3DPC), 2400 MT/s (1DPC/2DPC) o DDR4 LRDIMM3DS: 1866 Mt/s (3DPC), 2400 MT/s (1DPC/2DPC) o NVDIMM: 2133 Mt/s (1DPC)
- DDR4 standard I/O voltage of 1.2V Chipset Intel® C612 chipset
Intel® Server Board S2600WT Technical Product Specification 165 Feature Description External I/O connections
- DB-15 Video connectors o Front and Back on non-storage systems o Back only on storage systems (12 x 3.5” and 24 x 2.5” drive support)
- RJ-45 Serial Port A connector
- Dual RJ-45 Network Interface connectors supporting either : o 10 GbE RJ-45 connectors (Intel Server Board Product Code – S2600WTTR) or o 1 GbE RJ-45 connectors (Intel Server Board Product Code – S2600WT2R)
- Dedicated RJ-45 server management port
- Three USB 2.0 / 3.0 connectors on back panel
- Two USB 2.0 / 3.0 ports on front panel (non-storage models only)
- One USB 2.0 port on rack handle (storage models only) Internal I/O connectors / headers
- One Type-A USB 2.0 connector
- One 2x5 pin connector providing front panel support for two USB 2.0 ports
- One 2x10 pin connector providing front panel support for two USB 2.0 / 3.0 ports
- One 2x15 pin SSI-EEB compliant front panel header
- One 2x7pin Front Panel Video connector
- One 1x7pin header for optional Intel® Local Control Panel (LCP) support
- One DH-10 Serial Port B connector I/O Module Accessory Options The server board includes a proprietary on-board connector allowing for the installation of a variety of available I/O modules. An installed I/O module can be supported in addition to standard on-board features and add-in PCIe* cards.
- AXX4P1GBPWLIOM – Quad port RJ45 1 GbE based on Intel® Ethernet Controller I350
- TBD – Dual port RJ-45 10GBase-T I/O Module based on Intel® Ethernet Controller x540
- AXX10GBNIAIOM – Dual port SFP+ 10 GbE module based on Intel® 82599 10 GbE controller
- AXX1FDRIBIOM – Single port QSFP FDR 56 GT/S speed InfiniBand* module
- AXX2FDRIBIOM – Dual port QSFP FDR 56 GT/S speed infiniband* module
- AXX1P40FRTIOM – Single port QSFP+ 40 GbE module
- AXX2P40FRTIOM – Dual port QSFP+ 40 GbE module System Fans • Six managed hot swap system fans
- One power supply fan for each installed power supply module Riser Card Support Support for three riser cards.
- Riser #1 – PCIe* Gen3 x24 – up to 3 PCIe* slots
- Riser #2 – PCIe* Gen3 x24 – up to 3 PCIe* slots
- Riser #3 – PCIe* Gen3 x8 + DMI x4 (operating in PCIe* mode) – up to 2 PCIe* slots (Optional) With three riser cards installed, up to 8 possible add-in cards can be supported:
- 4 Full Height / Full Length + 2 Full Height / Half Length add-in cards via Risers #1 and #2
- 2 low profile add-in cards via Riser #3 (option)
- See Chapter 10 for available riser card options. Video
- Integrated 2D Video Controller
- 16 MB DDR3 Memory
Intel® Server Board S2600WT Technical Product Specification 166 Feature Description On-board storage controllers and options
- 10 x SATA 6Gbps ports (6Gb/s, 3 Gb/s and 1.5Gb/s transfer rates are supported)
- Two single port SATA connectors capable of supporting up to 6 Gb/sec
- Two 4-port mini-SAS HD (SFF-8643) connectors capable of supporting up to 6 Gb/sec /SATA
- One eUSB 2x5 pin connector to support 2mm low-profile eUSB solid state devices
- Optional SAS IOC/ROC support via on-board Intel® Integrated RAID module connector
- Embedded Software SATA RAID o Intel® Rapid Storage RAID Technology (RSTe) 4.0 o Intel® Embedded Server RAID Technology 2 (ESRT2) with optional RAID 5 key support Security • Intel® Trusted Platform Module (TPM) - AXXTPME5 (v1.2), AXXTPME6 (v2.0) and AXXTPME7 (v2.0) (Accessory Option) Server Management
- Integrated Baseboard Management Controller, IPMI 2.0 compliant
- Support for Intel® Server Management Software
- On-board RJ45 management port
- Advanced Server Management via an Intel® Remote Management Module 4 Lite (Accessory Option) Power Supply Options The server system can have up to two power supply modules installed, providing support for the following power configurations: 1+0, 1+1 Redundant Power, and 2+0 Combined Power Three power supply options:
- AC 750W Platinum
- DC 750W Gold
- AC 1100W Platinum Storage Options 12Gb/sec Hot Swap Backplane Options:
- 8 x 2.5” SATA/SAS
- 8 x 2.5” Combo Backplane - SATA/SAS + up to 4 x PCIe NVM Express* (Not Hot Swappable)
- 8 x 2.5” Combo Backplane - SATA/SAS + up to 4 x PCIe NVM Express* (Not Hot Swappable)
- 8 x 2.5” Dual Port SATA/SAS
- 8 x 3.5” SATA/SAS
- 12 x 3.5” SATA/SAS
12 Gb/sec 24 port SAS Expander Support (Accessory Options)
- Internal mount Intel® PCI Express 8-Lane, 4-Port Fan-Out Switch card
- 4 PCIe NVMe Express x 2.5” (Not Hot Swappable). Ideal to increase th number of NVMe SSDs in a system. System can support 2 Intel® PCI Express 8-Lane, 4-Port Fan- Out Switch cards, giving up to 8 NVMEs drives. Speed supported up to 8.0GT/s. Storage Bay Options:
- 8 x 3.5” SATA/SAS Hot Swap Drive Bays + Optical Drive support + front panel I/O
- 12 x 3.5” SATA/SAS Hot Swap Drive Bays (Storage model)
- 8 x 2.5” SATA/SAS Hot Swap Drive Bays + Optical Drive support + front panel I/O
- 16 x 2.5” SATA/SAS Hot Swap Drive Bays + Optical Drive support + front panel I/O
- 24 x 2.5” SATA/SAS Hot Swap Drive Bays (Storage model)
- 2 x 2.5” SATA SSD Back of Chassis Hot Swap Drive Bays (Accessory Option)
- 2 x internal fixed mount 2.5” SSDs ( All SKUs) Supported Rack Mount Kit Accessory Options
- AXXPRAIL – Tool-less rack mount rail kit – 800mm max travel length
- AXXELVRAIL – Enhanced value rack mount rail kit - 424mm max travel length
- AXX1U2UCMA – Cable Management Arm – (*supported with AXXPRAIL only)
- AXX2POSTBRCKT – 2-post fixed mount bracket kit (not supported with 12 and 24 drive storage SKUs)
Intel® Server Board S2600WT Technical Product Specification 167 Appendix H. Product Regulatory Information This product has been evaluated and certified as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product certification categories and/or environments (such as: medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment, etc.), other than an ITE application, will require further evaluation and may require additional regulatory approvals. Intel has verified that all L3, L6, and L9 server products1 as configured and sold by Intel to its customers comply with the requirements for all regulatory certifications defined in the following table. It is the Intel customer’s responsibility to ensure their final server system configurations are tested and certified to meet the regulatory requirements for the countries to which they plan to ship and or deploy server systems into. Intel® Server S2600WT Family NOTES “Wildcat Pass” Intel Project Code Name L3 Board L6 / L9 System Product Integration Level S2600WT R1000WT Intel® Server System R1000WT Family R2000WT Intel® Server System R2000WT Family Regulatory Certification RCM DoC Australia & New Zealand CB Certification & Report (International - report to include all CB country national deviations) China CCC Certification CU Certification (Russia/Belarus/Kazakhstan) Europe CE Declaration of Conformity FCC Part 15 Emissions Verification (USA & Canada) Germany GS Certification India BIS Certification Only applicable to select OEM defined SKUs International Compliance – CISPR32 & CISPR24 Japan VCCI Certification Korea KC Certification Mexico Certification NRTL Certification (USA & Canada) South Africa Certification Taiwan BSMI Certification (DOC) Ukraine Certification Table Key Not Tested / Not Certified Tested / Certified – Limited OEM SKUs only Testing / Certification (Planned) (Date) Tested / Certified 1 An L9 system configuration is a power-on ready server system with NO operating system installed. An L6 system configuration requires additional components to be installed in order to make it power -on ready. L3 are component building block options that require integration into a chassis to create a functional server system.
Intel® Server Board S2600WT Technical Product Specification 168 EU Directive 2019/424 (Lot 9) Beginning on March 1, 2020, an additional component of the European Union (EU) regulatory CE marking scheme, identified as EU Directive 2019/424 (Lot 9), will go into effect. After this date, all new server systems shipped into or deployed within the EU must meet the full CE marking requirements including those defined by the additional EU Lot 9 regulations. Intel has verified that all L3, L6, and L9 server products2 as configured and sold by Intel to its customers comply with the full CE regulatory requirements for the given product type, including those defined by EU Lot 9. It is the Intel customer’s responsibility to ensure their final server system configurations are SPEC® SERT™ tested and meet the new CE regulatory requirements. Visit the following website for additional EU Directive 2019/424 (Lot9) information: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32019R0424 In compliance with the EU Directive 2019/424 (Lot 9) materials efficiency requirements, Intel makes available all necessary product collaterals as identified below:
- Product Serviceability Instructions o Intel® Server System R1000WT Product Family System Integration and Service Guide o Intel® Server System R2000WT Product Family System Integration and Service Guide o https://www.intel.com/content/www/us/en/support/articles/000007225/server- products.html o https://www.intel.com/content/www/us/en/support/articles/000006751/server- products.html
- Product Specifications o Intel® Server Board S2600WT Product Family Technical Product Specification (This document) o Intel® Server System R1000WT Product Family Technical Product Specification o Intel® Server System R2000WT Product Family Technical Product Specification o https://www.intel.com/content/www/us/en/support/articles/000005856/server- products/server-boards.html
- System BIOS/Firmware and Security Updates – Intel® Server Board S2600WT family o System Update Package (SUP) – uEFI only o Intel® One Boot Flash Update (OFU) – Various OS Support o https://downloadcenter.intel.com/product/78562/Intel-Server-Board-S2600WT-Family
- Intel Solid State Drive (SSD) Secure Data Deletion and Firmware Updates o Note: for system configurations that may be configured with an Intel SSD o Intel® Solid State Drive Toolbox o https://downloadcenter.intel.com/download/29205?v=t
- Intel® RAID Controller Firmware Updates and other support collaterals o Note: for system configurations that may be configured with an Intel® RAID Controller o https://www.intel.com/content/www/us/en/support/products/43732/server-products/raid- products.html 2 An L9 system configuration is a power-on ready server system with NO operating system installed. An L6 system configuration requires additional components to be installed in order to make it power-on ready. L3 are component building block options that require integration into a chassis to create a functional server system
FRU devices on each platform. internal use area may vary with different BMC firmware revisions. Table 70. BMC FRU ID Mapping
Intel® Server Board S2600WT Technical Product Specification 170 Glossary This appendix contains important terms used in this document. For ease of use, numeric entries are listed first (for example, “82460GX”) followed by alpha entries (for example, “AGP 4x”). Acronyms are followed by non-acronyms. Term Definition ACPI Advanced Configuration and Power Interface APIC Advanced Programmable Interrupt Control ARP Address Resolution Protocal ASMI Advanced Server Management Interface BIOS Basic Input/Output System BIST Built-In Self Test BMC Baseboard Management Controller BPP Bits per pixel Bridge Circuitry connecting one computer bus to another, allowing an agent on one to access the other BSP Bootstrap Processor Byte 8-bit quantity CBC Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they bridge the IPMB buses of multiple chassis. CEK Common Enabling Kit CHAP Challenge Handshake Authentication Protocol CMOS Complementary Metal-oxide-semiconductor In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes of memory, which normally resides on the server board. DHCP Dynamic Host Configuration Protocol DPC Direct Platform Control EEPROM Electrically Erasable Programmable Read-Only Memory EHCI Enhanced Host Controller Interface EMP Emergency Management Port EPS External Product Specification ESB2 Enterprise South Bridge 2 FBD Fully Buffered DIMM F MB Flexible Mother Board FRB Fault Resilient Booting FRU Field Replaceable Unit FSB Front Side Bus GB 1024 MB GPA Guest Physical Address GPIO General Purpose I/O GTL Gunning Transceiver Logic HPA Host Physical Address HSC Hot-swap Controller Hz Hertz (1 cycle/second) I2C Inter-Integrated Circuit Bus
Intel® Server Board S2600WT Technical Product Specification 171 Term Definition IA Intel® Architecture IBF Input Buffer ICH I/O Controller Hub ICMB Intelligent Chassis Management Bus IERR Internal Error IFB I/O and Firmware Bridge ILM Independent Loading Mechanism IMC Integrated Memory Controller INTR Interrupt I/OAT I/O Acceleration Technology IOH I/O Hub IP Internet Protocol IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface IR Infrared ITP In-Target Probe KB 1024 bytes KCS Keyboard Controller Style KVM Keyboard, Video, Mouse LAN Local Area Network LCD Liquid Crystal Display LDAP Local Directory Authentication Protocol LED Light Emitting Diode LPC Low Pin Count LUN Logical Unit Number MAC Media Access Control MB 1024 KB MCH Memory Controller Hub MD2 Message Digest 2 – Hashing Algorithm MD5 Message Digest 5 – Hashing Algorithm – Higher Security ME Management Engine MMU Memory Management Unit ms Milliseconds MTTR Memory Type Range Register Mux Multiplexor NIC Network Interface Controller NMI Nonmaskable Interrupt OBF Output Buffer OEM Original Equipment Manufacturer Ohm Unit of electrical resistance OVP Over-voltage Protection PECI Platform Environment Control Interface PEF Platform Event Filtering PEP Platform Event Paging PIA Platform Information Area (This feature configures the firmware for the platform hardware)
Intel® Server Board S2600WT Technical Product Specification 172 Term Definition PLD Programmable Logic Device PMI Platform Management Interrupt POST Power-On Self Test PSMI Power Supply Management Interface PWM Pulse-Width Modulation QPI QuickPath Interconnect RAM Random Access Memory RASUM Reliability, Availability, Serviceability, Usability, and Manageability RISC Reduced Instruction Set Computing RMII Reduced Media-Independent Interface ROM Read Only Memory RTC Real-Time Clock (Component of ICH peripheral chip on the server board) SDR Sensor Data Record SECC Single Edge Connector Cartridge SEEPROM Serial Electrically Erasable Programmable Read-Only Memory SEL System Event Log SIO Server Input/Output SMBUS* System Management BUS SMI Server Management Interrupt (SMI is the highest priority non-maskable interrupt) SMM Server Management Mode SMS Server Management Software SNMP Simple Network Management Protocol SPS Server Platform Services SSE2 Streaming SIMD Extensions 2 SSE3 Streaming SIMD Extensions 3 SSE4 Streaming SIMD Extensions 4 TBD To Be Determined TDP Thermal Design Power TIM Thermal Interface Material UART Universal Asynchronous Receiver/Transmitter UDP User Datagram Protocol UHCI Universal Host Controller Interface URS Unified Retention System UTC Universal time coordinare VID Voltage Identification VRD Voltage Regulator Down VT Virtualization Technology Word 16-bit quantity WS-MAN Web Services for Management ZIF Zero Insertion Force
Intel® Server Board S2600WT Technical Product Specification 173 Reference Documents Advanced Configuration and Power Interface Specification, Revision 3.0, http://www.acpi.info/. Intelligent Platform Management Bus Communications Protocol Specification, Version 1.0. 1998. Intel Corporation, Hewlett-Packard Company, NEC Corporation, Dell Computer Corporation. Intelligent Platform Management Interface Specification, Version 2.0. 2004. Intel Corporation, Hewlett- Packard Company, NEC Corporation, Dell Computer Corporation. Platform Support for Serial-over-LAN (SOL), TMode, and Terminal Mode External Architecture Specification, Version 1.1, 02/01/02, Intel Corporation. Intel® Remote Management Module User’s Guide, Intel Corporation. Alert Standard Format (ASF) Specification, Version 2.0, 23 April 2003, ©2000-2003, Distributed Management Task Force, Inc., http://www.dmtf.org. Intel® Server System BIOS External Product Specification for Intel® Servers Systems supporting the Intel® Xeon® processor E5-2600 V3, v4 product family – (Intel NDA Required) Intel® Server System BIOS Setup Utility Guide for Intel® Servers Systems supporting the Intel® Xeon® processor E5-2600 V3, v4 product family Intel® Server System BMC Firmware External Product Specification for Intel® Servers Systems supporting the Intel® Xeon® processor E5-2600 V3, v4 product family – (Intel NDA Required) SmaRT & CLST Architecture on Intel Systems and Power Supplies Specification (Doc Reference # 461024) Intel Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080, and RMS25CB040 Hardware Users Guide Intel® Remote Management Module 4 Technical Product Specification Intel® Remote Management Module 4 and Integrated BMC Web Console Users Guide Intel® Server System R1000WT Technical Product Specification Intel® Server System R2000WT Technical Product Specification Intel® Ethernet Controller I350 Family Product Brief Intel® Ethernet Controller X540 Family Product Brief Intel® Chipset C610 product family (“Wellsburg”) External Design Specification – (Intel NDA Required) Intel® Xeon® Processor E5-4600/2600/2400/1600 v3, v4 Product Families (“Haswell and Broadwell”) External Design Specification – (Intel NDA Required)
Intel® Server Board S2600WT Technical Product Specification 174 NOTES