Features

G Isolation between water and electrical connections with Direct copper bonded Al 2O 3-ceramic G Planar passivated chips G Isolation voltage 3600 V~ G Keyed gate/cathode twin pins

Applications

G Large resistance welding equipment G Large electroplating equipment AC Controller with Isolated Water Flow Data according to IEC 60747 refer to a single thyristor unless otherwise stated. IXYS reserves the right to change limits, test conditions and dimensions 013 HVL 900 IRMS = 900 A VRRM = 1200-1800 V Preliminary data

© 2000 IXYS All rights reserved 2 - 3 Symbol Test Conditions Characteristic Values IRRM , IDRM TVJ = TVJM ; VR = VRRM ; VD = VDRM 40 mA VT, VF IT, IF = 600 A; TVJ = 25/G176C 1.32 V VT0 For power-loss calculations only 0.8 V rT 0.68 m /G87 VGT VD = 6 V; T VJ = 25/G176C2 V TVJ = -40/G176C3 V IGT VD = 6 V; T VJ = 25/G176C 150 mA TVJ = -40/G176C 220 mA VGD TVJ = TVJM ;V D = 2/3 VDRM 0.25 V IGD TVJ = TVJM ;V D = 2/3 VDRM 10 mA IL TVJ = 25/G176C; tP = 30 /G109s; VD = 6 V 200 mA IG = 0.45 A; diG /dt = 0.45 A//G109s IH TVJ = 25/G176C; VD = 6 V; RGK = /G165 150 mA tgd TVJ = 25/G176C; VD = 1/2 VDRM 2 /G109s IG = 1 A; diG /dt = 1 A//G109s Q S TVJ = 125/G176C; IT, IF = 300 A; -di/dt = 50 A//G109s 760 /G109C IRM 275 A R thJW per thyristor ; 180° el; watervolume = 4 l/min 0.203 K/W dS Creeping distance on surface 12.7 mm dA Creepage distance in air 9.6 mm a Maximum allowable acceleration 50 m/s 2 O ptional accessories for modules Keyed Gate/Cathode twin plugs with wire length = 350 mm, gate = yellow, cathode = red Type ZY 180 L (L = Left for pin pair 4/5) UL 758, style 1385, Type ZY 180 R (R = Right for pin pair 6/7) CSA class 5851, guide 460-1-1 Fig. 1 Gate trigger characteristics Fig. 2 Gate trigger delay time HVL 900 0.01 0.1 1 10 100 10-3 10-2 10-1 100 101 102 0.1 IG VG A A IG 1: IGT , TVJ = 140/c176 C 2: IGT , TVJ = 25/c176 C 3: IGT , TVJ = -40/c176 C µs tgd V 4: PGM = 20 W 5: PGM = 60 W 6: PGM = 120 W IGD , TVJ = 140/c176 C Limittyp. TVJ = 25/c176 C (Thermoswitch on request)

© 2000 IXYS All rights reserved 3 - 3 2 l/min 4 l/min 6 l/min Fig. 6 Transient thermal impedance vs. time 11 0 104 105 106 0.001 0.01 0.1 1 2000 4000 6000 8000 10000 I2t s t ms t A2s ITSM A 80 % VRRM TVJ = 45°C 50 Hz TVJ = 140°C TVJ = 140°C TVJ = 45°C VR = 0V Fig. 3 Surge overload current ITSM : Crest value, t: duration Fig. 4 I2t versus time (1-10 ms) 1 10 100 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 ED [%] Irms [A] Fig. 5 Rated rms current vs. duty cycle n=1 n=100 n=50 n=25 n=10 n=5 n=2 0.001 0.01 0.1 1 10 100 1 1030 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 0.22 t [s] Zth [K/W] HVL 900