FMMAGGAUGE TOKYOKEISO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 16
Technical content
UP GRADED WITH WIDER LINEUP FM MAG GAUGE METAL TUBE LEVEL GAUGE GENERAL FM Mag Gauge is a float type metal tube level gauge. Liquid level is indicated by clear and visible color flappers. This eliminates problems likely in indication by existing glass gauges. In addition, special material of PVC, Fluorocarbon resin etc. are ready to cover very corrosive liquid level measurement. Alarm contacts and / or analog output unit can be additionally pro- vided for remote monitoring and control purpose. OPERATION PRINCIPLE A float, in which a rounded shape magnet is integrated, is located in a non-magnetic tube (called Chamber). This float moves up and down depending on the liquid level in chamber with specified draft line. Outside of the chamber, an indicator unit is installed, in which plastic magnet rotating flappers are provided. The front surfaces of such flappers are black and the other sides of flappers are co - loured in yellow for every 10mm and red for every 100mm. Then these flappers are rotated by movement of float to indicate liquid level in colour flappers. FM Mag Gauge can be provided with alarm contacts and/or analog output (DC4~20mA) unit additionally onto this level indicator. A reed switch in aluminum case at the setting point is actuated by the magnet in moving float. Water-tight construction, intrinsically safe system with the safety relay,and flameproof enclo - sure are available. The 4 to 20 mA output type has the detection mechanism of float loca - tion (liquid level) along chamber. The detector consists of a series of reed switches and precision type resistances which are actuated by the magnet inside float. The voltage signal of liquid level is converted to 4 to 20 mA signal for transmitting. Water-tight construction and flame- proof enclosure are available.
FEATURES
❏ Metal tube Free from breakage and leakage. ❏ Clear and visible indication By colour flappers, Liquid level in tanks is easily observed even from a distance. Free from blurs and smudges which are common for Glass Gauges. ❏ Covering high pressure and temperature HPGSL*1 approved version is also available. *1 High Pressure Gas Safety Law ❏ Various materials available In addition to standard stainless steel, highly corrosion-resistant materials such as PVC and fluororesin are available. ❏ Full function Indication, alarm contacts as well as analog output. One unit of FM Mag Gauge covers all necessary functions of level monitoring and control. TG-L2262-E05 6th edition Feb 2026 K 1st edition Jun 2022 K
2 TOKYO KEISO CO., LTD. STANDARD SPECIFICATION Measuring object : Max. viscosity 600mPa.s and without sticking and crystallization. Available range : Refer to pages of subject models. Maximum OP . Press. : Refer to pages of subject models. Temp. range : Refer to pages of subject models. Level indication : By colour flappers Interval of flappers : 10mm Indication accuracy : ±15mm Process connection. : Standard; Tank side through 1"(25mm) flanges Details are to be referred to pages of subject models. Material : To be referred to pages of subject models. * The indication can follow up to 2cm/s in liquid level changing speed. Consult factory for jacket type. Consult factory for the direction of the connection nozzle other than “side – side”. DESCRIPTION OF MODEL CODE Model code of FM Mag Gauge is described as follows; 1) Only for local indicator FM- 123-4 2) Local indicator+Alarm contacts FM- 123-4567 3) Local indicator+Analog output FM- 123-4/89 4) Local indicator+Alarm contacts+Analog output FM- 123-4567/89 /89 to be added to the end of code indication 2) Press., Temp. class (2 digit) Chamber, Nozzle material Float material and density range Conn. /f_lange rating Enclosure of alarm (Water-tight, intrinsic safety, /f_lameproof) No. of contact No. of terminal box Enclosure of analog unit (Water-tight, intrinsic safety, /f_lameproof) Direction of sensor Direction of convertor Indicator Alarm Analog output Refer to pages of subject models for details of model code. SUGGESTIONS
- On liquid level indication The indicator flappers are actuated by magnet in float. There are different types of float for models, but the position of magnet and actual liquid level (Draft line to float) are different depending on the liquid density. Thus, the position where specific indicator flapper rotates and the position of actual liquid level are different slightly. This gap is fixed and shifted upward in fixed value. This gap (A) is indicated in Approval drawing. The zero line of indicator is to be located above actual liquid zero point by distance of A. Refer to instruction manual for details. Also, be careful for minimum density for the float. Operation prob - lem may occur in case of lower density than designed density. Interface measurement and / or extreme low and high density liquid measurement are available on request. Consult factory for details.
- Heating and heat insulation In case of necessity of heating and thermal insulation for sticky liq- uids etc., thermal insulation is to be provided only for chamber por- tion as shown below. Do not cover indicator, alarm and analog unit by thermal insulation material. The heating or insulation on these parts might causes damages or malfuntioning of indication, alarm or transmitting mechanism. A
TOKYO KEISO CO., LTD. 3 MODEL SELECTION GUIDANCE Different types and materials are available for FM Mag Gauge. Refer to the following table for selection.
- For normal temperature (Up to 120°C. Note that certain resins have a narrower temperature range.) Model Chamber material Float material Temperature range (°C) Max. operating pressure Available length (mm) MPa Min. Max. FM- 121□ SUS304 ✽3 -10 ≦ t ≦ 120 SUS: 3 TP340: 2.5 0 to 250 0 to 4380122□ SUS316 SUS316, SUS316L or titanium (TP340)123□ SUS316L 12Z□ Special metal Consultation required FM- 124□ PVC (HPVC) PVC (HPVC) 0 ≦ t ≦ 60 (80) 0.2 0 to 250 0 to 2000 125□ Stainless steel + PVC lining 0 to 4000 FM- 126□ Stainless steel + ETFE lining NBR foam + PFA lining 0 ≦ t ≦ 100 0.2 0 to 250 127□ Stainless steel + PFA lining 0 to 3500FM- 128□ Stainless steel + PTFE lining FM- 141□ SUS304 ✽3 ✽1 0 to 250 0 to 4380142□ SUS316 titanium alloy -10 ≦ t ≦ 120 13143□ SUS316L 14Z□ Special metal
- For high temperature Model Chamber material Float material Temperature range (°C) Max. operating pressure Available length (mm) MPa Min. Max. FM- 161□ SUS304 ✽3 ✽1✽4 0 to 250 0 to 4380 162□ SUS316 SUS316, SUS316L or titanium (TP340) –196 ≦ t ≦ +150 –10 ≦ t ≦ +400 The maximum operating temperature for TP340 is 250ºC. SUS: 2 TP340: 1.6 163□ SUS316L 16Z□ Special metal Consultation required FM- 181□ SUS304 ✽3 ✽1✽4 0 to 250 0 to 4380182□ SUS316 Titanium alloy –196 ≦ t ≦ +150 –10 ≦ t ≦ +400 13183□ SUS316L 189□ Special metal ✽1 : For -196℃ ≦ t < -10℃, a sealed indicator is used for manufacturing. ✽2 : ETFE lining is available up to 2400 mm, and PTFE lining for full vacuum is available up to 2500 mm. ✽3 : Titanium (TP340) and titanium alloys are susceptible to hydrogen embrittlement in a hydrogen atmosphere. ✽4 : For 350℃ < t, the indicator will use window glass.
4 TOKYO KEISO CO., LTD. INDICATOR INSTALLATION ANGLE 1. Standard FLOAT AVAILABILITY AND SIZES L A 48.5 Draft No. A N P Density (g/cm 3) 0.39~0.45 0.44~0.52 0.5~0.6 0.55~0.7 0.62~0.8 0.6~0.7 0.65~0.8 0.7~0.9 0.8~1.0 0.9~1.4 1.0~1.5 1.25~2.0 Design C 450 350 280 250 210 485 385 305 235 195 165 165 200 200 200 200 200 160 150 130 110 110 100 100 L 470 380 300 270 220 520 410 320 250 200 170 170 Material TP340 Titanium SUS316 or SUS316L Float E Consult factory for details when max. press. exceeds these values. R1/2 R1/2 56 120 EH*C F (H+100) Indication gap H 60.5 (H+100) * Actual length "C" may be extended depending on the /f_loat type as is the case of gas /f_illed type. Consult factory for details. MODEL CODE Flapper pitch Chamber material 10mm(Accuracy 15mm) SUS304 SUS316 SUS316L Other 0.39~0.45 0.44~0.52 0.5~0.6 0.55~0.7 0.62~0.8 0.6~0.7 0.65~0.8 0.7~0.9 0.8~1.0 0.9~1.4 1.0~1.5 1.25~2.0 25A JIS 10KFF 25A JIS 10KRF 1" JPI 150#RF 1" ANSI 150#RF 25A JIS 20KRF 1" JPI 300#RF 1" ANS I300#RF 25A JIS 5KFF Other 1" (25A) /f_langes Special TP340 Titanium SUS316 or SUS316L Density range (g/cm3) Float material Connection /f_lange rating FM-1210,1220,1230,12Z0 Standard metallic type for low pressure and moderate temperature FM-12 0 series are standard type Mag gauge with SUS304, SUS316, or SUS316L material. (titanium float is used for some ranges.) AVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~4380mm Max. Press. : F .V. ~3MPa (F .V. ~2.5MPa for a titanium float) Temp. range : · FM-1200 (select FM-1600 for t<-10℃ and 120℃<t) DIMENSIONS
TOKYO KEISO CO., LTD. 5 FM-121Z0,122Z0,123Z0,12ZZ0 Double tube type for liquefied gas 60.5 76.3 (Outside pipe) (Inside pipe) 2X 5 hole Lower part of chamber 2X 2 hole Upper part of chamber R1/2 HC R1/2 76.3 F F (H+100) HIndication gap 68 130 E INDICATOR INSTALLATION ANGLE MODEL CODE Material TP340 Titanium No. A 0.39 ~ 0.45 0.44 ~ 0.52 0.5 ~ 0.6 0.55 ~ 0.7 0.62 ~ 0.8 Design C 780 580 450 380 320 E 200 200 200 200 200 L 790 610 470 400 330 Float L Draft A 48.5 Ar Gas Sealed 0.91(MPa) Densitiy (g/cm3) Max. operating press. is 1.96MPa. Consult factory for details when max. press. exceeds this value. The direction to install indicator can not be changed at site. TP340 Titanium ZZ Chamber material A Z SUS304 SUS316 SUS316L Other 0.39~0.45 0.44~0.52 0.5~0.6 0.55~0.7 0.62~0.8 Special 25A JIS 10KFF 25A JIS 10KRF 1" JPI 150#RF 1" ANSI 150#RF 25A JIS 20KRF 1" JPI 300#RF 1" ANSI 300#RF 25A JIS 5KFF Other 1" (25A) /f_langes Special FM-12 Densitiy range (g/cm3) Float material Connection /f_lange rating
Description
FM-12 0 are metal tube level gauge for liquefied gas with SUS304, SUS316, or SUS316L material. A double tube type has the effectiveness that inhibits the sudden rise and dive of a float by boiling and bumping of liquefied gas. AVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~4380mm Temp. range : -10℃≦t≦120℃ -60℃≦t<10℃ (sealed indicator) DIMENSIONS 1. Standard FLOAT AVAILABILITY AND SIZES
6 TOKYO KEISO CO., LTD. FM-1240,1250 Made of PVC for low pressure and moderate temperature FM-1240 series are level gauge with PVC material for both cham- ber and float to cover corrosive liquids. FM-1250 has a PVC lined stainless steel chamber which offers bet- ter mechanical durability than pure PVC chambers. AVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~2000mm *2 Max. Press. : 0.2MPa (cannot withstand full vacuum) Temp. range : 0°C≦t≦60 o C (HPVC : 0°C≦t≦80°C) DIMENSIONS INDICATOR INSTALLATION ANGLE MODEL CODE FLOAT AVAILABILITY AND SIZES For PVC version FM-124 ■■ and HPVC version FM-124H ■■ *1 Float material is PVC or HPVC. ( ) indicates applicable den- sity range for FM-125 ■■ type (Stainless steel + PVC lining). *2 In case of material code 5, max.4000mm is available. *3 Connection flange of lined version is Flat Face (20A or more). The inside of parenthesis shows the thickness of flange. L No. 0.75~0.9 0.8~1.0 0.9~1.3 1.05~1.7 1.4~2.0 Design C 290 250 200 150 140 120 120 120 120 120 L 300 250 200 150 150 Float PVC,HPVC E Density (g/cm3) For Stainless steel+PVC lining version FM-125 ■■ L No. 0.7~0.8 0.75~0.9 0.85~1.2 1.0~1.5 1.35~2.0 Design C 290 250 200 150 140 150 150 160 170 180 L 300 250 200 150 150 Float PVC E Density (g/cm3) R1/2 F H HC E Indication gap (H+100) 120 R1/2 PVC FM-124/uni25A1 HPVC FM-124H/uni25A1 PVC lined SS FM-125/uni25A1 t JIS10K50ARF F C H E Indication gap H (H+100) 56 120 t F 60.5 Flapper pitch 10mm ( Accuracy 15mm) PVC HPVC St. Stl.+PVC lining 0.75~0.9 (0.7~0.8) 0.8~1.0 (0.75~0.9) 0.9~1.3 (0.85~1.2) 1.05~1.7 (1.0~1.5) 1.4~2.0 (1.35~2.0) 25A JIS 10KFF (t=21) 1" JPI 150#FF (t=19.7) 1" ANSI 150#FF (t=19.7) 25A JIS 5KFF (t=17) Other 1" (25A) /f_langes Special H Connection /f_lange rating *3 Density range (g/cm3) Float material *1 Chamber material No.1.Standard No.2 No.3 FM-124□ FM-124H□ No.1.Standard No.2 No.3 FM-125□
TOKYO KEISO CO., LTD. 7 This series of gauges is made of fluorocarbon resin and other anti- corrosive materials. AVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~3500mm Maximum range of ETFE lining type is 2400mm Temp. range : 0°C≦t≦100 o C Details of lining ETFE lining : FM-126 ■■ Lining thickness 1.6 mm PFA lining : FM-127 ■■ Lining thickness 1.75 mm DIMENSIONS FM-1260, 1270 Made of Fluorocarbon resin for low pressure and moderate temperature INDICATOR INSTALLATION ANGLE ETFE lining FM-126 ■■ 1. Standard Equivalent to JIS10K50ARF C H (H+100) H ø60.5 56Indication gap 122 E 114 ø60.5 F H 114(134) C E F Indication gap Equivalent to JIS10K50ARF Vent hole Vent hole H=H0–(C+E+114) PFA lining FM-127 ■■ MODEL CODE FLOAT AVAILABILITY AND SIZES For ETFE lining version FM-126 ■■ Titanium+PFA lining available on request (Dimension will be changed. Consult factory for details.) *1 The float for vacuum services is made of either stainless steel or titanium lined by ETFE. *2 The blind flanges for vacuum services are made of carbon steel lined by PTFE. *3 The float for vacuum services has a different shape and sizes. *4 Connection F *5 Shape and dimension E *6 Measuring range H For PFA lining version FM-127 ■■ Chamber material 10mm(Accuracy ±15mm) ETFE lining PFA lining 0.72~0.75 0.75~0.8 0.8~0.9 0.9~1.0 1.0~1.3 1.3~1.5 1.5~2.0 25A JIS 10K 1" ANSI(JPI)#150 Flapper pitch NBR+ PFA lining(1.5t) Special Special Density range (g/cm3) Float material Connection /f_lange rating * No. A B C E F G H 0.72~0.75 0.75~0.8 0.8~0.9 0.9~1.0 1.0~1.3 1.3~1.5 1.5~2.0 Design C 400 370 310 240 200 190 190 L 400 345 280 210 170 190 190 190 190 190 190 190 190 190 FloatL 42.6 ADraft E Density (g/cm3) * The flange face of lining type is equivalent to the raised face of flange. No. A B C E F G H 0.72~0.75 0.75~0.8 0.8~0.9 0.9~1.0 1.0~1.3 1.3~1.5 1.5~2.0 Design C 400 350 280 210 170 190 170 L 400 345 280 210 170 190 190 E 270 270 280 280 280 260 270 FloatL 42.6 ADraft Density (g/cm3) Titanium+PFA lining available on request (Dimension will be changed. Consult factory for details.) * Vent holes are arranged on the metal tube. Do not fill them with paint or heat insulator. Keep vent holes away from rain water and condensation. If gas penetrating the lining dissolves into any water, it may corrode the metal tube.
8 TOKYO KEISO CO., LTD. This series of gauges is made of fluorocarbon resin and other anti- corrosive materials. AVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~3500mm *1 Temp. range : 0°C≦t≦100 o C Details of lining PTFE lining : FM-128 ■■ Lining thickness 2 mm : 3mm for vacuum application *1: Max. 2500mm for vacuum application DIMENSIONS FM-1280 Made of Fluorocarbon resin for low pressure and moderate temperature MODEL CODE FLOAT AVAILABILITY AND SIZES * Titanium+PFA lining available on request (Dimension will be changed. Consult factory for details.) * Vacuum application of PTFE, dimension will be changed. 1. Standard *2 The flange face of lining type is equivalent to the raised face of flange. *3 The float for vacuum services is made of either stainless steel or titanium lined by ETFE. *4 Connection F *5 Measuring range H Indication gap Equivalent to JIS10K50ARF H 120 ø60.5 C115 F F E (H+100) H=H0–(E+C+115) Vent hole Vent hole Chamber material 10mm(Accuracy 15mm) PTFE lining 0.72~0.75 0.75~0.8 0.8~0.9 0.9~1.0 1.0~1.3 1.3~1.5 1.5~2.0 25A JIS 10K 1" ANSI(JPI)#150 Flapper pitch NBR+ *3 PFA lining(1.5t) Special Special Density range (g/cm3) Float material Connection /f_lange rating *2 No. A B C E F G H 0.72~0.75 0.75~0.8 0.8~0.9 0.9~1.0 1.0~1.3 1.3~1.5 1.5~2.0 Design C 400 350 280 210 170 190 190 E 260 260 270 270 270 260 270 L 400 345 280 210 170 190 190 FloatL 42.6 ADraft Density (g/cm3) INDICATOR INSTALLATION ANGLE * Vent holes are arranged on the metal tube. Do not fill them with paint or heat insulator. Keep vent holes away from rain water and condensation. If gas penetrating the lining dissolves into any water, it may corrode the metal tube.
TOKYO KEISO CO., LTD. 9 AVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~4380mm Max. Press. : See the table below. Temp. range : –10°C ≦ T ≦ 120 o C (Select FM-1800 for a temperature of t<–10°C and 120°C<t) DIMENSIONS FM-1410, 1420, 1430, 14Z0 Metallic type for high pressure and moderate temperature INDICATOR INSTALLATION ANGLE 1. Standard MODEL CODE Gasket: 3.3 20K, 30K, #300 Class : 22.4 40K, #600 Class : 31.8 63K, #900, 1500 Class : 44.5 Indication gap • A FM-14 – Description Chamber material
1 SUS304
2 SUS316
3 SUS316L
(g/cm Float materia A 0.52 ≦ ρ < 0.54 Ti-6Al-4V (titanium alloy) ★For low- viscosity (water- equivalent) liquids B 0.54 ≦ ρ < 0.57 C 0.57 ≦ ρ < 0.61 D 0.61 ≦ ρ < 0.69 E 0.69 ≦ ρ < 0.85 F 0.85 ≦ ρ < 1.20 1 0.59 ≦ ρ < 0.61 Ti-6Al-4V (titanium alloy) ■ For high- viscosity (oil- equivalent) liquids 2 0.61 ≦ ρ < 0.65 3 0.65 ≦ ρ < 0.70 4 0.70 ≦ ρ < 0.80 5 0.80 ≦ ρ < 1.00 6 1.00 ≦ ρ < 1.40 Z Special Ti-6Al-4V Connection ange rating 1 25A JIS 40KRF 2 1" JPI 600#RF 3 1" ANSI 600#RF 4 25A JIS 63KRF 5 1" JPI 900#RF 6 1" ANSI 900#RF
9 Special
Titanium alloys are susceptible to hydrogen embrittlement in a hydrogen atmosphere. FLOAT AVAILABILITY AND SIZES No. Density ρ (g/cm ) Design Float C E L A 0.52 ≦ ρ < 0.54 715 200 756 B 0.54 ≦ ρ < 0.57 615 200 655 C 0.57 ≦ ρ < 0.61 515 200 554 D 0.61 ≦ ρ < 0.69 420 200 453 E 0.69 ≦ ρ < 0.85 315 200 352 F 0.85 ≦ ρ < 1.20 215 200 250 1 0.59 ≦ ρ < 0.61 710 200 760 2 0.61 ≦ ρ < 0.65 615 200 659 3 0.65 ≦ ρ < 0.70 515 200 558 4 0.70 ≦ ρ < 0.80 420 200 457 5 0.80 ≦ ρ < 1.00 320 200 356 6 1.00 ≦ ρ < 1.40 215 200 254 Z Special – – – Allowable measurement temperature and pressure Float No. A to E, 1 to 6 Can withstand full vacuum. T (°C) –10 0 25 50 75 100 120 L φ49 φ41 L φ49 φ45 Float /uni2605 For low-viscosity liquids Float /uni25A0 For high-viscosity liquids
10 TOKYO KEISO CO., LTD. INDICATOR INSTALLATION ANGLE FLOAT AVAILABILITY AND SIZES FM-1600 is a series of metal tube level gauge for high temperature with stainless steel chamber and float (titanium float for low density applications). FM-1610, 1620, 1630, 16Z0 Metallic type for low pressure and high temperature MODEL CODE 110 60.5 120 H HC (H+100) R1/2 R 1/2 Indication gap E F * Dimension will be changed. Consult factory for details. 1. Standard Heating / thermal insulation are to be conducted onto chamber portion only. Chamber material Connection /f_lange rating SUS304 SUS316 SUS316L Other 0.39~0.45 0.44~0.52 0.5~0.6 0.55~0.7 0.62~0.8 0.65~0.8 0.7~0.9 0.8~1.0 0.9~1.4 1.0~1.5 25A JIS 10KFF 25A JIS 10KRF 1" JPI 150# RF 1" ANSI 150# RF 25A JIS 20KRF 1" JPI 300# RF 1" ANSI 300# RF 25A JIS 5KFF Other 1"(25mm) /f_langes Special Density range (g/cm3) Float material TP340 Titanium SUS316 or SUS316L L A 48.5 Draft No. A P 0.39~0.45 0.44~0.52 0.5~0.6 0.55~0.7 0.62~0.8 0.65~0.8 0.7~0.9 0.8~1.0 0.9~1.4 1.0~1.5 Design C 620 490 390 340 290 460 400 300 260 230 200 200 200 200 200 170 170 150 150 130 L 650 520 410 360 300 460 400 300 260 230 Material TP340 Titanium *0.68MPa Float E SUS316 or SUS316L *(1.35MPa) * Consult factory for details when max. press. exceeds these value. Density (g/cm3) AVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~4380mm Temp. Range and Max. Press. SUS316 & 316L Float: -196≦t≦+400°C, FV≦P<1.35MPa TP340 Float: -196≦t≦+250°C, FV≦P<0.68MPa SUS316 & 316L Float (Gas Sealed): -196≦t≦+225°C, FV≦P≦2MPa TP340 Float (Gas Sealed): -196≦t≦+175°C, FV≦P≦1.6MPa Indicator Specifications -10≦t≦+350°C: Standard type -196≦t≦+150°C: Sealed type 350°C<t: Indicator glass Caution Alarm and 4-20mA output have individual temperature limits. DIMENSIONS
TOKYO KEISO CO., LTD. 11 INDICATOR INSTALLATION ANGLE FM-1810, 1820, 1830, 18Z0 Metallic type for high pressure and high temperature MODEL CODEAVAILABLE RANGES OF PRODUCTS Range : Min. 0~250mm Max. 0~4380mm Max. Press. : See the table below. Temp. range : –96°C ≦ t ≦ +150°C (sealed indicator) –0°C ≦ t ≦ +400°C (For 350°C >t, the indicator will use window glass.) (Please note that alarm switches and analog output, 4 to 20 mA, transmitters have their own temperature limits.) DIMENSIONS Heating / terminal insulation are to be conducted onto chamber portion only. 1. Standard Gasket: 3.3 20K, 30K, #300 Class : 22.4 40K, #600 Class : 31.8 63K, #900, 1500 Class : 44.5 Indication gap • A FM-18 – Description Chamber material (g/cm Float materia A 0.57 ≦ ρ < 0.60 Ti-6Al-4V (titanium alloy) ★For low- viscosity (water- equivalent) liquids B 0.60 ≦ ρ < 0.64 C 0.64 ≦ ρ < 0.70 D 0.70 ≦ ρ < 0.81 E 0.81 ≦ ρ < 1.04 F 1.04 ≦ ρ < 1.50 1 0.64 ≦ ρ < 0.68 Ti-6Al-4V (titanium alloy) ■ For high- viscosity (oil- equivalent) liquids 2 0.68 ≦ ρ < 0.73 3 0.73 ≦ ρ < 0.81 4 0.81 ≦ ρ < 0.94 5 0.94 ≦ ρ < 1.22 6 1.22 ≦ ρ < 1.60 Z Special Ti-6Al-4V Connection ange rating 1 1" JPI 900#RF 2 1" ANSI 900#RF 3 1" JPI 900#RTJ 4 1" ANSI 900#RTJ 5 1" JPI 1500#RF 6 1" ANSI 1500#RF 7 1" JPI 1500#RTJ 8 1" ANSI 1500#RTJ Titanium alloys are susceptible to hydrogen embrittlement in a hydrogen atmosphere. FLOAT AVAILABILITY AND SIZES No. Density ρ (g/cm ) Design Float C E L A 0.57 ≦ ρ < 0.60 705 200 756 B 0.60 ≦ ρ < 0.64 605 200 655 C 0.64 ≦ ρ < 0.70 510 200 554 D 0.70 ≦ ρ < 0.81 410 200 453 E 0.81 ≦ ρ < 1.04 310 200 352 F 1.04 ≦ ρ < 1.50 210 200 250 1 0.64 ≦ ρ < 0.68 710 200 760 2 0.68 ≦ ρ < 0.73 610 200 659 3 0.73 ≦ ρ < 0.81 510 200 558 4 0.81 ≦ ρ < 0.94 410 200 457 5 0.94 ≦ ρ < 1.22 310 200 356 6 1.22 ≦ ρ < 1.60 210 200 254 Z Special – – – L φ49 φ41 L φ49 φ45 Float /uni2605 For low-viscosity liquids Float /uni25A0 For high-viscosity liquids Allowable measurement temperature and pressure Float No. A to E, 1 to 6 Can withstand full vacuum. T (°C) –196 –175 –150 –125 –100 –75 –50 –25 0 25 50 75 T (°C) 100 125 150 175 200 225 250 275 300 325 350 375 400
12 TOKYO KEISO CO., LTD. Support Indicator window glass Sealed type ・A support is provided when the face-to-face dimension is 2500 mm or more. ・The support material is 304SS. ・Mounting holes on a support are designed for M16 bolts. If M16 bolts are not applicable, M12 bolts can be used instead with plain washers of 12 nominal diameter. ・Standard: Left-side mounting ・When the gauge has a scale plate, the indicator is yellow at 10 mm intervals only. ・When using a capacity scale plate, a tank table is required to indicate both capacity and liquid level. Height scale plate (the scale plate is optional) Example: For 1000 mm measurement range (left-side mounting) Example of character size Material: SUS304 Plate thickness: t=1.5 Background color: White Font color: Black Character size: 6 Scale: Black Measurement range: 1000 Indicator Indicator window glass : A single indicator can cover a measurement range of up to 800 mm. For ranges exceeding this, the indicator is split, resulting in an unmeasurable zone of approximately 30 mm, as shown in the illustration below. Sealed type : A single indicator can cover a measurement range of up to 2900 mm. For ranges exceeding this, the indicator is split, resulting in an unmeasurable zone of approximately 60 mm, as shown in the illustration below.
TOKYO KEISO CO., LTD. 13 SPECIFICATION Type of contact : 1 X SPST(Self-holding contact) Contact capacity : 10W, AC/DC Max. voltage ; AC,DC 100V Fluid temp. : –10~200 o C Ambient temp. : –10~60 o C Enclosure : Watertight No. of contact : Depending on the length of chamber (No limitation) Repeatability : ±15mm (Equivalent to indicator accuracy) Reset span : Max. 30mm (Fixed) Alarm action : High or Low (To be specified. Also at field adjustable) Setting range : 50mm (70 mm between H-L) Min. gap between points : 50mm (Shorter gap on request) Accessory : Surge suppressor intergrated (It is not attached to IS version) Terminal box : The cable from a reed switch is drawn and it is used for terminal connection. Installed terminal : 8P , M3.5 screws Cable entries : For alarm switches 4 entries with packing type cable gland, Max. cable dia. 7 mm For alarm outlet
1 X G3/4 (Female)
Construction : Splash-proof construction Protection rating : IP66&IP67 MODEL CODE OF ALARM CONTACTS Alarm contact (s) can be provided to all FM Mag Gauges. A reed switch is located at side portion of chamber which is actu- ated by the magnet in float. Watertight, Intrinsically safe as well as Flameproof versions are available. ADD-ON ALARM CONTACTS Watertight (Non-explosion proof) EX-d, Flameproof EX-i, Intrinsically safe No. of contact No. of terminal box Enclosure Contact Terminal box FM-1 A safety relay is inserted into the contact loop of watertight version to achieve Insrinsically safe loop. IS classification : Ex ia llC T6 (Subject to using of specified safety relay) Dimension of Safety Relay EB3C-R01A (1 point use) Note 1: When installing the insulating material, do not install it around the alarm sensor. [Materials and exterior] No. Part Material Exterior ① Switch body A6063P Anodized aluminum ② Cable PVC --- ③ Terminal box (case) AC2A Painted silver (polyurethane resin) ④ Terminal box (cover) SUS304 Unpainted ⑤ Bracket SUS304 Unpainted
14 TOKYO KEISO CO., LTD. Individual reed switch and terminals are capcellated in one pres- sure tight housing for each alarm contact. Construction : Flameproof enclosure (d2G5) (No. T49972) Type of contact : SPST (Self-holding contact) Contact capacity : 10W, AC/DC Max. voltage ; AC,DC 100V No. of contact : Depending on the length of chamber (No limitation) Repeatability : ±15mm (Equivalent to indicator accuracy) Reset span : Max. 30mm (Fixed) Alarm action : High or Low (To be specified.) Setting range : From 100 mm above lower end to 100 mm below upper end Min. gap between points : 250mm (Shorter gap on request) Fluid temp. : -10~200˚C Amb. temp. : -10~60˚C Accessory : Surge suppressor integrated Built-in terminal : 2P (M3) Installation : Clamping onto chamber Cable entry : 1XG1/2 (Female) Note: A cable gland is optional. A cable gland must be used for the gauge to be ap- proved as a flameproof enclosure. If pro- vided by the customer, use the SXBM-16B of Shimada Electric Co., Ltd. Protection rating : IP66 Material: AC2A Exterior: Silver paint (polyurethane resin) Built-in terminal: M3 x 2P
TOKYO KEISO CO., LTD. 15 The 4 to 20mA 2-wire current transmitter can be additionally pro- vided for all types of FM-1000 Mag Gauge even together with alarm contact (s). Watertight, Intrinsically safe and Flameproof versions are available to meet area classification. ADD-ON CURRENT LEVEL TRANSMITTER MODEL CODE OF ANALOG TRANSMITTER DIMENSION Watertight (W) and Intrinsically safe (S) Watertight Flameproof Intrinsically safe Right hand side Left hand side Right hand side Left hand side FM-1 Enclosure Direction of sensor Direction of Converter 8 9 10 W E S R L R L Flameproof version (E) Note 1: The transmitter (4 to 20mA) shall be replaced or readjusted after returning to Tokyo Keiso. Note 2: When installing the insulating material, do not install it around the detector. *: For the TIIS flameproof type, mount the flameproof cable gland included in the package, or one of those specified by TOKYO KEISO, directly to the wiring port of the gauge. Use a cable recommended for explosionproof wiring, such as a control cable (JIS C3401) or one with similar specifications. Perform waterproof treatment by applying non-hardenable sealant, such as a liquid gasket, to the connection of the cable gland and the gauge. SPECIFICATION Output span : Min. 0~250mm Max. 0~4380mm (Shorter output span than measuring range on request) Enclosure : 1) Watertight 2) Flameproof Ex d IIB T6, RIIS certification No. TC14720 3) Intrinsically safe Ex ia IIC T4, RIIS certification No. TC16354 Protection rating : Flameproof: IP66 Watertight, Intrinsic safety: IP66 & IP67 Fluid temp. : –20~200˚C Amb. temp. : –20~55˚C Power supply : Nominal DC24V Max. load resistance Watertight (W) 600Ω Flameproof (E) 600Ω Intrinsically safe construction (600 – Resistance inside barrier)Ω For MTL7728+: 600 - 333 = 267Ω For MTL7787+: 600 - 359 = 241Ω (Cautions) When using an MTL7728+ barrier for this intrinsically safe trans- mitter, the load must be connected to the positive (+) terminal, because the negative (−) terminal is grounded. When the load cannot be connected to the positive terminal, use of an MTL7787+ barrier is recommended. Output accuracy : ±(0.2+ ×100)% F .S. H : Measuring range(mm) Resolution : 5 mm If the detector does not detect magnetic force, the unit outputs 26 mA or more. H From the bottom relative to the measurement range H Chamber Detector Transducer Indicating unit Output position: 100% (20 mA) Actual liquid level: 100% Actual liquid level: 0% Output position: 0% (4 mA) Max. transmission span H 4 to 20 mA output range Indication gap Measurement range H Transducer position Y From the bottom relative to the measurement range H Chamber Detector Transducer Indicating unit Output position: 100% (20 mA) Actual liquid level: 100% Actual liquid level: 0% Output position: 0% (4 mA) Max. transmission span H 4 to 20 mA output range Indication gap Measurement range H Transducer position Y
16 TOKYO KEISO CO., LTD. Typical specification sheet Use following sheet for your inquiry or ordering Model code Fluid Pressure Other requirements FM-1/uni25A1/uni25A1/uni25A1-/uni25A1/uni25A1/uni25A1/uni25A1 / /uni25A1/uni25A1/uni25A1 MPa mm Temperature °C Density Quantity Viscosity Measuring span (measuring range) Connection /f_lange size and rating Head Of/f_ice :Shiba Toho Building, 1 – 7 – 24 Shibakoen, Minato-ku, Tokyo 105 – 8558 Tel : +81-3 – 3431 – 1625 (KEY) ; Fax : +81-3 – 3433 – 4922 * Speci/f_ication is subject to change without notice.