3400R TOKYOKEISO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 12
Technical content
The Coriolis mass flowmeter MASSMAX 3400R series consists of the single Z-shaped measuring tube which is well-accepted as very small flow measurement, and newly-developed high performance converter MMC400R. The epoch-making sensing technologies have achieved the accurate flow measurement of very small flow rate with a wide rangeability. Stainless steel 316L as standard and Hastelloy ® C22 as an option are used for the wetted parts of the flowmeter. With 3 sizes of 1, 3 and 4mm MASSMAX MMC400R is suitable for the accurate measurement of very small flow rate as low as 1 kg/h or less.
FEATURES
❏ High accuracy measurement of very small flow rate down to 5 g/ min ❏ Maximum pressure rating 30 MPa ❏ High accuracy: ±0.1% of reading (+ Zero stability) ❏ Excellent zero stability and high vibration proof ❏ Duplicated protection with outer housing made of stainless steel ❏ Available both sensor-converter integrally mounted compact type, and separately mounted remote type ❏ Compliant with Japanese standard explosionproof STANDARD SPECIFICATIONS
- Measuring principle : Coriolis force
- Meter size : 01, 03, 04 (mm)
- Measuring range : Meter size kg/h kg/min Max. flow rate Min. flow rate Max. flow rate Min. flow rate 01 20 0.3 0.333 0.005 03 130 2 2.166 0.033 04 450 7 7.5 0.1166
- Enclosure : IP67 (IEC 60529)
- Ambient temperature : −40 to +60°C (compact type: Aluminum alloy converter) −40 to +65°C (compact type: Stainless steel converter) –40 to +65°C (remote type) See [Explosionproof] for the ambient temperature range of Ex types. Fluid specifications
- Fluid : Liquids
- Fluid temperature and pressure: Measuring Tube Temperature * Pressure S Stainless steel 316L –40 to +150°C 0 to 15 MPa (abs) H Hastelloy ® C-22 0 to 30 MPa (abs) Note: Pressure in this table means the allowable pressure range of the measuring tube. See [Pressure and temperature rating table] for details. * See [Explosionproof] for the ambient temperature range of Ex types.
- Density : UPLHN Sensor specifications
- Process connection : 1/4” NPT Male
- Materials: Wetted parts: Material symbol S H (Option) Measuring Tube Stainless steel 316L Hastelloy ® C22 Fittings Stainless steel 316L Hastelloy ® C22 Non Wetted Part: Outer housing; Stainless steel 316L Base plate; Stainless steel 316L
- Outer housing protection:
3 MPa (abs) or less in fluid pressure
: Standard More than 3 MPa (abs) in fluid pressure : With a bursting disc TG-F2198-E00 1st edition Aug 2022 K MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow
- Housing material : Aluminum alloy, SS316L as an option
- Painting : Siloxane coating
- Color : Gray for converter housing, jade green for converter cover and terminal cover
- Power supply : 100 V to 230 V AC (85 V to 253 V AC) Option; 24 V DC (11 to 31 V DC) Voltages in parentheses indicate the acceptable voltage range.
- Supply frequency : 50/60Hz AC
- Power consumption : AC; approx. 22 VA, DC; approx. 12 W
- Grounding : Gr ounding resistance must be less than 100 Ω for Non-ex types (Q-type), less than 10 Ω for Ex types
- Cable Entry : G1/2 Female adapter × 2 or 1/2 NPT Female adapter × 2 or M20 × 1.5 Female thread × 2 or G1/2 Flame proof adapter × 2 (Japanese standard explosionproof) Note: Up to 3 cable entries can be provided. Indication and outputs
- Display : Blue dot matrix LCD with backlight 128 × 64 pixels (59 × 31 mm) Each of 4 screens shows data in up to 3 lines. Data include instantaneous mass flow rate (bar graph indication available), totalized mass flow, instantaneous volume flow rate, totalized volume flow rate, density, temperature, and instantaneous flow rate trend graph (percentage indication). Setting parameters and self-diagnosis results are also displayed. Units of instantaneous mass flow rate : kg/h, kg/min, kg/sec, t/h, and others Forward and reverse flow directions are indicated with "+" or "−". Units of totalized mass flow rate : kg, t, g, and others Totalization of flow rates in forward and reverse directions is possible. Units of density : g/cm 3, kg/m3, and others Units of temperature : °C, and others
- Current output : 4 to 20 mA (max. 22 mA) *Preparing for HART communication Load resistance is less than 1000 Ω.±5μA Select from among instantaneous mass flow rate, density, and temperature.
- Pulse output : Open collector output Load rating: 32 V DC 20 mA or less (100 Hz < f ≤ 10 kHz) Residual voltage at close <1.5 V (load current ≤ 1 mA) <2.5 V (load current ≤ 10 mA) <5 V (load current ≤ 20 mA) 100 mA or less (f ≤ 100 Hz) Residual voltage at close <0.2 V (load current ≤ 10 mA) <2 V (load current ≤ 100 mA) Output frequency : Max. 10 kHz Pulse rate : 36 to 36,000,000 pulse/h (0.01 Hz to 10 kHz) Pulse width : Selectable from: (1) Automatic: Pulse width which makes duty 50% at full scale frequency (2) Fixed duty ratio: Always 1:1 (3) Arbitrary setting: 0.05 to 2000 ms
- Status output : Open collector output Load rating : 32 V DC, 100 mA or less Residual voltage at close <0.2 V (load current ≤ 10 mA) <2 V (load current ≤ 100 mA) Contents : Selectable from: (1) No status output (default setting) (2) Flow direction identification (3) Flow over-range (4) Totalization preset (5) Range iden tification (when double ranges are used) (6) Errors and measurement alarms for flow rate, density, temperature, and others
- Control input Input voltage : 8 to 32 V DC (ON)/2.5 V DC, 0.4 mA or less (OFF) Max. current : 6.5 mA (input voltage ≤ 24 V DC) Max. current : 8.2 mA (input voltage ≤ 32 V DC) Control target : Selectable from: (1) No control input (default setting) (2) Hold output (3) Lock output at 0% (4) Reset totalization counter (5) Reset errors (6) Range identification (when double ranges are used) (7) Others
- Combination of outputs Standard : 4 to 20 mA output × 1, pulse output × 1, status output × 1, control input × 1 (total 4 points) Option 1 : 4 to 20 mA output × 2, pulse output × 1 (total 3 points) Option 2 : 4 to 20 mA output × 3, pulse output × 1 (total 4 points) Option 3 : 4 to 20 mA output × 2, status output or pulse output (selectable) × 2 (total 4 points) See "Converter code" on page 11 for details.
- Low cut-off : Current output and pulse output (can be set separately for each indication) Range : 0 to 20% F .S. (0.1% step) Hysteresis : 0 to 5% F .S. (0.1% step)
- Time constant : Current output and pulse output (can be set separately for each indication) Range : 0.0 to 100.0 sec (0.1 sec step) Standard functions
- User-defined measuring units : Units for mass, volume, and time can be defined (max. 7 letters).
- Bi-directional flow measurement : Flow rates in both directions can be measured. Flow direction is output as status output.
- Self-diagnosis : Error messages and status messages are displayed. Function : CPU, memory, software, hardware, output connection Status : Over-range, count-over, power failure Application : Oscillating balance of measuring tube, vibration energy, other sensor circuit diagnosis
- Testing : Built-in simulator of current and pulse outputs Allows for loop check without calibrator.
- Touch sensor (optical key) : Four touch sensors enable data to be set from outside without the need for opening the cover. These serve as push buttons while the cover is opened. 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow 2 TOKYO KEISO CO., LTD.
Accuracy (calibrated at the factory)
- Mass flow rate (pulse output) Accuracy ±0.1% of reading Zero stability ±0.0057% of max. flow rate
- Reference conditions: Water at 20°C, 0.2 MPa Measurement error (accuracy + zero stability) Flow rate (% of max. flow rate) Accuracy (±% of reading) Flow rate Measurement error ( ±% of reading) % of max. flow rate 100% 0.106 50% 0.111 20% 0.129 10% 0.157 5% 0.214 1.5% 0.48 Note: Accuracy is not assured for flow rates less than 1.5% of max. flow rate. Effects of changes in process conditions: Fluid temperature: ±0.0056% of max. flow rate for each 1°C Example When the size changes by 1°C with size S01: 20 kg/h × 0.000056 = 0.00112 kg/h Fluid pressure: ±0.013% of max. flow rate for each 0.1 MPa These effects should be considered when process conditions change after zero adjustment. Temperature (indicated value) Measuring range –40 to + 150 ˆ Accuracy ±1ˆ Pressure and temperature rating UBCMF Note: Specify the bursting disc when the process pressure is more than the limitation. Temperature (°C) Pressure (MPa) Hastelloy ® C22 sensor Stainless steel measuring tube Outer housing 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow TOKYO KEISO CO., LTD. 3
- Japanese standard explosionproof Type of protection and class: Compact type MMM3400RC-JEx (Certificate number: CML21JPN1739X, CML21JPN21175X) Ex db ia IIC T6...T1 Ga/Gb Ex db eb ia IIC T6...T1 Ga/Gb Ex tb IIIC T165°C Db Remote type sensor MMS3000RF-JEx (Certificate number: CML21JPN2904X, CML21JPN21181X) Ex ia IIC T6...T1 Ga Ex ia IIIC T165°C Da Remote type converter MMC400RF-JEx (Certificate number: CML21JPN1740X, CML21JPN21182X) Ex db [ia] IIC T6 Gb Ex db eb [ia] IIC T6.Gb Ex tb IIIC T75°C Db Compact type MMM3400RC-JEx (Japanese standard explosionproof) Compact type MMM3400C-Ex (ATEX/IECEx explosionproof) Aluminum alloy converter housing (standard) Ambient temperature °C Fluid temperature °C Temperature class Max. surface temperature °C –40 to +40
65 T6–T1 T80
80 T5–T1 T95
115 T4–T1 T130
150 T3–T1 T165
–40 to +50
130 T3–T1 T165
–40 to +65 65 T6–T1 T80 Stainless steel converter housing (optional) Ambient temperature °C Fluid temperature °C Temperature class Max. surface temperature °C –40 to +40 –40 to +50
130 T3–T1 T145
–40 to +65 60 T6–T1 T75 Remote type MMS3000RF-JEx (Japanese standard explosionproof) Remote type MMS3000F-Ex (ATEX/IECEx explosionproof) Ambient temperature °C Fluid temperature °C Temperature class Max. surface temperature °C –40 to +40 –40 to +50 –40 to +65
- ATEX explosionproof Type of protection and class: Compact type MMM3400C-Ex (Certificate number: PTB17 ATEX 2008 X) II 1/2(1)G Ex db ia [ia Ga] IIC T6...T1 Ga/Gb or II 1/2(1)G Ex db eb ia [ia Ga] IIC T6...T1 Ga/Gb or II 1/2 G Ex db ia IIC T6...T1 Ga/Gb II 1/2 G Ex db ea ia IIC T6...T1 Ga/Gb II 2(1)D Ex tb [ia Da] IIIC Txxx°C Db or II 2D Ex tb IIIC Txxx°C Db Remote type sensor MMS3000F-Ex (Certificate number: PTB17 ATEX 2007 X) II 1 G Ex ia IIC T6...T1 Ga or II 1 D Ex ia IIIC Txxx°C Da Remote type converter MMC400F-Ex (Certificate number: PTB17 ATEX 2009 X) II 2(1) G Ex db [ia Ga] IIC T6 Gb II 2(1)G Ex db eb [ia Ga] IIC T6 Gb or II 2 G Ex db[ia] IIC T6 Gb or II 2 G Ex db eb [ia] IIC T6 Gb or II 2(1)D Ex tb [ia Da] IIIC T75°C Db or II 2D Ex tb IIIC T75°C Db IECEx explosionproof Type of protection and class: Compact type MMM3400C-Ex (Certificate number: IECEx PTB17.0029X) Ex db ia [ia Ga] IIC T6...T1 Ga/Gb or Ex db eb ia [ia Ga] IIC T6...T1 Ga/Gb or Ex ia IIC T6...T1 Ga/Gb or Ex eb ia IIC T6...T1 Ga/Gb or Ex tb [ia Da] IIIC Txxx°C Db or Ex tb IIIC Txxx°C Db Remote type sensor MMS3000F-Ex (Certificate number: IECEx PTB17.0028X) Ex ia IIC T6...T1 Ga or II 1 D Ex ia IIIC Txxx°C Da Remote type converter MMC400F-Ex (Certificate number: IECEx PTB17.0030X) Ex db [ia Ga] IIC T6 Gb Ex db eb [ia Ga] IIC T6 Gb or Ex db[ia] IIC T6 Gb or Ex db eb [ia] IIC T6 Gb or Ex tb [ia Da] IIIC T75°C Db or Ex tb IIIC T75°C Db 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow 4 TOKYO KEISO CO., LTD.
[Compact type] Converter Sensor Outer housing Cable entry Process connection Power supply Input/ output Base plate FLOW RANGE Meter size Max. flow rate kg/h Kg/min 01 20 0.333 03 130 2.166 04 450 7.5 MEASURING TUBE DIMENSIONS Meter size Materials Dimensions (mm) Inside diameter Wall thickness 01 S 1.20 0.20H 03 S 2.58 0.30H 04 S 3.94 0.41H .BUFSJBM44UBJOMFTTTUFFM- ) )BTUFMMPZ$ 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow TOKYO KEISO CO., LTD. 5
[I/O terminals of MMC400RC/F converters]
- Two terminals for current output and pulse or status output (standard output) When other inputs/outputs are required, select them from the options. The power supply terminal block has a protection cover. Protection cover Terminals Description L/L L and N for AC power supply L+ and L− for DC power supplyN/L− Grounding Terminals Polarity Description (Standard: Code 600) DŖŖ Pulse or status output, frequency pulse, alarm outputD+ CŖŖ Current output (4 to 20 mA/internal power supply)C+ BŖ B AŖ A
- Terminal type : Plug-in type screw terminal
- Wire cross section : 0.5 to 2.5 mm 2
- Cable outside diameter : 7 to 12 mm
- Connection diagram for optional outputs (modular I/O print circuit) Converter specifications Polarity Option 1 Current output, pulse or status output, control input (6EK) Option 2 Current output × 2, pulse or status output (6A8) Option 3 Current output × 3, pulse or status output (6AA) Option 4 Current output × 2, pulse or status output × 2 (6AE) Terminal DŖŖ Pulse or status output, frequency pulse, alarm output Pulse or status output Pulse or status output Pulse or status output No. 1 CŖŖ Current output Current output No. 1 Current output No. 1 Current output No. 1C+ BŖŖ Control input Current output No. 2 Pulse or status output No. 2 AŖŖ Status output or pulse, frequency pulse, alarm output Current output No. 2 Current output No. 3 Current output No. 2A+ [Remote type sensor cable MMS3000RF + MMC400RF] MMC400RF converter
- Terminal type: Spring clamp
- Cable: Dedicated ᶃTerminal block ᶄCable gland ᶅCable fastening grip for grounding Dedicated sensor cable
- 10-core compound cable with 0.5 mm 2 conductor
- Outside diameter : Approx. 11 mm
- Max. length: 20 m MMS3000RF sensor
- Terminal type: Spring clamp
- Cable: Dedicated ᶃ ᶅ ᶄ ᶅ ᶄ ᶃ 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow 6 TOKYO KEISO CO., LTD.
- ...3$DPNQBDUUZQF
- ..43'SFNPUFUZQFTFOTPS 'MPXEJSFDUJPOBTTUBOEBSE 'MPXEJSFDUJPOBTTUBOEBSE .BTT"QQSPYLH -FOHUI(NNGPS(GFNBMFBEBQUFS /15GFNBMFBEBQUFSBOE8BUFS1SPPGHMBOE NNGPS+BQBOFTFTUBOEBSEFYQMPTJPOQSPPG DPOTUSVDUJPO 5IFCBTFQMBUFPGqPXNFUFSTIBMMCFpYFE pSNMZPOBQFEFTUBMPSUIFMJLF%POPU TVQQPSUqPXNFUFSTCZQJQJOHPSQJQJOHpUUJOHT .BTT"QQSPYLH " " П П П 'PSNPVOUJOH "r" #BTFQMBUF П 'PSNPVOUJOH "r" #BTFQMBUF " " 0VUFSIPVTJOHQSPUFDUJPO 4UBOEBSE 5IFCBTFQMBUFPGqPXNFUFSTIBMMCFpYFE pSNMZPOBQFEFTUBMPSUIFMJLF%POPU TVQQPSUqPXNFUFSTCZQJQJOHPSQJQJOHpUUJOHT 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow TOKYO KEISO CO., LTD. 7
- ..$3'SFNPUFUZQFDPOWFSUFS 0QUJPOBM6CPMU GPSQJQF JOTUBMMBUJPO QJQFTVQQMJFECZDVTUPNFST П ПП П .BTT"QQSPYLH -FOHUI(NNGPS(GFNBMF BEBQUFS /15GFNBMFBEBQUFS BOE8BUFS1SPPGHMBOE NNGPS+BQBOFTFTUBOEBSE FYQMPTJPOQSPPGDPOTUSVDUJPO 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow 8 TOKYO KEISO CO., LTD.
DIMENSIONS (optional)
- ...3$DPNQBDUUZQFXJUIqBOHFpUUJOH "+*4, ʡ"4.&MC ʡ"4.&MC "r" ʶ 'MPXEJSFDUJPOBTTUBOEBSE П
- 8JUICVSTUJOHEJTD GPSJMMVTUSBUJPOQVSQPTFT 8IFOqVJEQSFTTVSFFYDFFET.1B BCVSTUJOHEJTDJTBEEFEUPUIFPVUFSIPVTJOHGPSSFMFBTJOHQSFTTVSF
- )FBUJOHKBDLFU GPSJMMVTUSBUJPOQVSQPTFT )FBUJOHKBDLFUDBOOPUCFVTFEXJUIBCVSTUJOHEJTD #VSTUJOHEJTD /15NBMFPOUIFqPXNFUFSTJEF )FBUJOHKBDLFUDPOOFDUJPO /15GFNBMFPOUIFqPXNFUFSTJEF "r" "r" -FOHUI(NNGPS(GFNBMFBEBQUFS /15GFNBMFBEBQUFSBOE8BUFS1SPPGHMBOE NNGPS+BQBOFTFTUBOEBSEFYQMPTJPOQSPPG DPOTUSVDUJPO 5IFCBTFQMBUFPGqPXNFUFSTIBMMCFpYFE pSNMZPOBQFEFTUBMPSUIFMJLF%POPU TVQQPSUqPXNFUFSTCZQJQJOHPSQJQJOHpUUJOHT П 'PSNPVOUJOH #BTFQMBUF .BTT"QQSPYLH 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow TOKYO KEISO CO., LTD. 9
MODEL AND SPECIFICATION CODES Measuring tube material: "S" Stainless Steel 316L (standard) / "H" Hastelloy® C22 (optional) [Model code] Specifications Compact type (Sensor + Converter) Remote type Sensor Converter General purpose (non explosionproof) MMM3400RC- ■□□ MMS3000RF- ■□□ MMC400RF Japanese standard explosionproof MMM3400RC-JEx- ■□□ MMS3000RF-JEx- ■□□ MMC400RF-JEx ATEX / IECEx explosionproof MMM3400C-Ex- ■□□ MMS3000F-Ex- ■□□ MMC400F-Ex Note: ■: S or H are assigned material codes. □□: 01 or 03 or 04 are assigned as size codes. [Sensor code] Sensor Spec. Code VE 4 0 0 0 0 Description Std. Sensor Code VE MMS3000 Sensor (Single Z-shaped Measuring Tube) ○ Meter Size
01 Meter Size 01 ○
03 Meter Size 03 ○
04 Meter Size 04 ○
(Fixed Code) 4 Always 4 ○ Measuring Tube Material S Stainless steel 316L ○ HH a s t e l l o y ® C22 Measuring Tube Surface Finish 0 Standard ○ Process Connection HK 1/4" NPT male ○ UH 15A JIS20K KD 1/2" ASME class150 KE 1/2" ASME class300 (Fixed Code) 0 Always 0 ○ Outer Housing Pressure Rating A When the fluid pressure is 3 MPa at 20°C or less (standard) ○ C When the fluid pressure is 3 MPa at 20°C or higher with bursting disc Heating Jacket 0 Without ○
2 Heating jacket (1/4NPT female)
0 Without
1 ATEX explosionproof (Ex)
RI E C E x e x p l o s i o n p r o o f ( E x )
9 Japanese standard explosionproof (JEx) ○
Sanitary Approvals 0 Without ○ Type
0 Compact type ○
1 Remote type with aluminum terminal box
2 Remote type with Stainless Steel terminal box
Calibration 0 Standard 3-point flow calibration ○ 1 5-point fow calibration Degreasing 0 Without ○
1 Degreasing wetted parts
(Fixed Code) 0 Always 0 Converter type 6 Compact type 7R e m o t e t y p e Special specifications 00 Without ○ 00/Z Special 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow 10 TOKYO KEISO CO., LTD.
[Converter code ] MMC400RC/RF Converter Spec. Code VE 54 4 2 0 0 2 0 0 Description Std. Converter code VE 54 MMC400R converter ○ (Fixed code) 4 Always 4 ○ Type
4 Compact type ○
H Remote type (mandatory for ship class, high temperature, and low temperature models) Power supply A 100 to 230 V AC ○ 1 12 to 24 V DC Explosionproof Approval
0 Without ○
FI E C E x e x p l o s i o n p r o o f ( E x )
9 Japanese standard explosionproof (JEx)
Cable entries for input, output, and power supply 0M 2 0 × 1.5 female for ATEX explosionproof 4 1/2NPT female adapter
5 G1/2 female adapter ○
6 Waterproof gland
9 G1/2 flameproof gasket adapter for Japanese standard
Language for indication 2 English ○ (Fixed code) 0 0 Always 00 ○ Converter housing
1 Aluminum alloy ○
2 SS316L (compact type)
3 SS316L (remote type)
(Fixed code) 2 Always 2 ○ Output 6 0 0 4 to 20 mA × 1, pulse or status × 1, total 2 ○
6 E K 4 to 20 mA × 1, pulse × 1, status × 1, control input × 1
6 A 8 4 to 20 mA × 2, pulse or status × 1 (selectable)
6 A A 4 to 20 mA × 3, pulse or status × 1 (selectable)
6 A E 4 to 20 mA × 2, pulse × 1, pulse or status × 1 (selectable)
Measurement 0 Mass flow rate, density, temperature as standard ○ (Fixed code) 0 Always 0 ○ Sensor cable
0 Without (compact type) ○
4 5 m cable (only for remote type) 1 10 m cable (only for remote type) 5 20 m cable (only for remote type) Special specifications 00 Without 00/Z Special /PUF4QFDJBMSFRVJSFNFOUTOPUJODMVEFEJOUIFBCPWFDPEJOHTZT UFNTIPVMECFEFTJHOBUFECZBEEJOH;BUUIFFOEPGUIFDPEF $POTVMUVTGPSUIF BWBJMBCJMJUZPGTVDISFRVJSFNFOUTCFGPSFPSEFSJOH STANDARD ACCESSORIES
- Data sheet for setting : 1 set
- Instruction manual : 1 set OPTIONS
- Waterproof cable gland for G1/2 cable connection (code: WG)
- Number of cable entries for external connection: 3 (code: 3G)
- U bolt for 2" pipe installation (code: PM) SPECIFICATION CODES WHEN ORDERING 1. Model and specifications Examples Model: MMM3400RC Sensor Code : VE014S0HK0A0000000600 Converter Code : VE5444A052001260000000 2. Options as requested Specify them with their codes. 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow TOKYO KEISO CO., LTD. 11
Observe followings for the installation of MASSMAX 3400R on the piping.
- In both cases of horizontal and vertical installation, the base plate of flowmeter shall be fixed firmly on a pedestal or the like by using 4 mounting holes located on the base plate as shown in figure ① below. Do not support the flowmeter by piping or piping fittings.
- Install the flowmeter on the vertical piping within the allowable inclination as shown in drawings ②. Do not install the flowmeter on the inclined piping.
- Do not install the flowmeter as note 1 and note 2 below.
- Arrange the piping so that the measuring tube is filled with fully liquid.
- Install the control valve at the downstream side of the flowmeter, if required, to avoid possible cavitation caused by throttli ng of upstream control valve. ᶄ ᶃInstall the flowmeter on the flat surface. ᶃ Note 1 Note 2 Note 1: Avoid too much stress to the flowmeter from the installed piping. Eliminate any distortion or centering deviation of piping before installation. ᶄWhen installing the flowmeter on the vertical lines, install it within the following inclination to make draining and venting easy during the stoppage of fluid. <Inclination angle> S01: less than 7 degrees S03 and S04: less than 13 degrees Note 2 : Do not install the flowmeter upside down. Head Office : Shiba Toho Building, 1 – 7 – 24 Shibakoen, Minato-ku, Tokyo 105 – 8558 Tel : +81-3 – 3431 – 1625 (KEY) ; Fax : +81-3 – 3433 – 4922 * Specification is subject to change without notice. 5('& MASSMAX 3400R Series Coriolis Mass Flowmeter with Single Measuring Tube for Small Flow 12 TOKYO KEISO CO., LTD.