7400R TOKYOKEISO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 17
Technical content
The MASSMAX 7400R Coriolis mass flowmeter series consists of a popular single straight tube with low pressure loss and self-cleaning property, and the newly developed high-performance MMC400R converter. Innovative sensing technologies have eliminated restrictions on installation, achieving accurate flow measurement with simple mounting. Titanium is used for the measuring tube (wetted parts) as standard. Hastelloy ® C22, Stainless Steel, and Tantalum are available on request. With 7 connection sizes from 6 mm to 80 mm, the MASSMAX7400R covers various applications from small flow to large flow.
FEATURES
❏Completely straight single measuring tube. Excellent self-cleaning property and low pressure loss ❏Simple installation eliminates the restrictions of on-site measures such as piping support and vibration shock reduction, saving space and cost ❏High accuracy: ±0.1% of reading (+zero stability) ❏Excellent zero stability and high vibration resistance ❏Duplicated protection with outer cylinder made of Stainless Steel ❏Simultaneous measurement of mass flow rate (instantaneous and totalized), density, and temperature with one instrument ❏Compact type and remote type available ❏Compliant with Japanese standard explosionproof ❏Titanium is used for wetted parts as standard. Hastelloy ® C22, Stainless Steel, and Tantalum are also available, covering a wide variety of applications STANDARD SPECIFICATIONS
- Measuring principle: Coriolis force
- Meter size: 06, 10, 15, 25, 40, 50, 80 (mm)*
- Measuring range: Meter size * kg/h kg/min Max. flow rate Min. flow rate Max. flow rate Min. flow rate 06 1,230 9.5 20.5 0.158 10 3,500 27 58.3 0.450 15 14,600 112.5 243.3 1.875 25 44,800 345 746.7 5.750 40 120,000 915 2,000 15.25 50 234,000 1,800 3,900 30.00 80 560,000 4,300 9,333 71.66 * The measuring tubes of Hastelloy ® C22 are available for sizes 10 to 80 (mm), Tantalum for sizes 10 to 50 (mm) and Stainless Steel for sizes 06 to 50 (mm).
- Enclosure : IP67 (IEC 60529)
- Ambient temperature : −40 to +60°C (compact type) −40 to +65°C (remote type sensor and converter) See [Explosionproof] for the ambient temperature range of Ex types. Fluid specifications
- Fluid : Liquids
- Fluid temperature and pressure: Measuring tube Temperature * 1 Pressure *2 T Titanium –40 to +150°C –0.1 to 10 MPa H Hastelloy ® C22 0 to +100°C –0.1 to 5 MPa S Stainless steel (S31803) 0 to +100°C –0.1 to 5 MPa A Tantalum 0 to +100°C –0.1 to 5 MPa Note: See [Pressure and temperature rating table] for details. *1 See [Explosionproof] for the ambient temperature range of Ex types. *2 Pressure in this table means the maximum pressure of the measuring tube. The operating pressure of the process is lower than the maximum operating pressure of the flange (or fitting) or outer cylinder. See [Pressure and temperature rating table] for details.
- Density : 400 to 2000 kg/m 3 Sensor specifications
- Process connection: Flange; JIS10K/20K or equivalent ASME Class 150/300 or equivalent, etc. Sanitary fitting; ISO 2852 ferrule, etc. (optional)
- Materials: Wetted parts: Measuring tube material T H * S * A * Measuring tube Titanium (ASTM Grade 9) Hastelloy® C22 Stainless Steel UNS S31803 (Equiv. to JIS SUS329J3L) Tantalum UNS R05255 Flange gasket sheet Titanium (ASTM Grade 2) Hastelloy® C22 Stainless Steel UNS S31803 (Equiv. to JIS SUS329J3L) Tantalum UNS R05200 * Optional Non Wetted Part; Flanges: Stainless Steel 316 / 316L dual certified Outer cylinder (Protective housing): Stainless Steel 304 / 304L dual certified Stainless Steel 316 / 316 L dual certified* * Optional
- Outer cylinder (Protective housing) allowable pressure: 10 MPa at 20°C as standard. PED qualified version of 6.3 or 10 MPa at 20°C are available as an option. See [Pressure and temperature rating table] for details. TG-F2202-E00 1st edition Aug 2022 K MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube
- Housing material : Aluminum alloy, SS316L as an option
- Painting : Siloxane coating
- Color : Gray for converter housing, jade green for converter cover and terminal cover
- Power supply : 100 V to 230 V AC (85 V to 253 V AC) Option; 24 V DC (11 to 31 V DC) Voltages in parentheses indicate the acceptable voltage range.
- Supply frequency : 48 to 63 Hz
- Power consumption : AC; approx. 22 VA, DC; approx. 12 W
- Grounding : Grounding resistance must be less than 100 Ω for Non-ex types (D-type), less than 10 Ω for Ex types
- Cable Entry : G1/2 Female adapter × 2 or 1/2 NPT Female adapter × 2 or M20 × 1.5 Female thread × 2 or G1/2 Flame proof adapter × 2 (Japanese standard explosionproof) Note: Up to 3 cable entries can be provided. Indication and outputs
- Display : Blue dot matrix LCD with backlight 128 × 64 pixels (59 × 31 mm) Each of 4 screens shows data in up to 3 lines. Data include instantaneous mass flow rate (bar graph indication available), totalized mass flow, instantaneous volumeflow rate, totalized volume flow rate, density, temperature, and instantaneous flow rate trend graph (percentage indication). Setting parameters and self-diagnosis results are also displayed. Units of instantaneous mass flow rate: kg/h, kg/min, kg/sec, t/h, and others Forward and reverse flow directions are indicated with "+" or "−". Units of totalized mass flow rate: kg, t, g, and others Totalization of flow rates in forward and reverse directions is possible. Units of density : g/cm 3, kg/m3, and others Units of temperature : °C, and others
- Current output : 4 to 20 mA (max. 22 mA) *Preparing for HART communication Load resistance is less than 1000 Ω. Select from among instantaneous mass flow rate, density, and temperature.
- Pulse output : Open collector output Load rating : 32 V DC 20 mA or less (100 Hz < f ≤ 10 kHz) Residual voltage at close <1.5 V (load current ≤ 1 mA) <2.5 V (load current ≤ 10 mA) <5 V (load current ≤ 20 mA) 100 mA or less (f ≤ 100 Hz) Residual voltage at close <0.2 V (load current ≤ 10 mA) <2 V (load current ≤ 100 mA) Output frequency : Max. 10 kHz Pulse rate : 36 to 36,000,000 pulse/h (0.01 Hz to 10 kHz) Pulse width : Selectable from: (1) Automatic: Pulse width which makes duty 50% at full scale frequency (2) Fixed duty ratio: Always 1:1 (3) Arbitrary setting: 0.05 to 2000 ms
- Status output : Open collector output Load rating : 32 V DC, 100 mA or less Residual voltage at close <0.2 V (load current ≤ 10 mA) <2 V (load current ≤ 100 mA) Contents : Selectable from: (1) No status output (default setting) (2) Flow direction identification (3) Flow over-range (4) Totalization preset (5) Range identification (when double ranges are used) (6) Errors and measurement alarms for flow rate, density, temperature, and others
- Control input Input voltage : 8 to 32 V DC (ON)/2.5 V DC, 0.4 mA or less (OFF) Max. current : 6.5 mA (input voltage ≤ 24 V DC) Max. current : 8.2 mA (input voltage ≤ 32 V DC) Control target : Selectable from: (1) No control input (default setting) (2) Hold output (3) Lock output at 0% (4) Reset totalization counter (5) Reset errors (6) Range identification (when double ranges are used) (7) Others
- Combination of outputs Standard : 4 to 20 mA output × 1, pulse output × 1, status output × 1, control input × 1 (total 4 points) Option 1 : 4 to 20 mA output × 2, pulse output × 1 (total 3 points) Option 2 : 4 to 20 mA output × 3, pulse output × 1 (total 4 points) Option 3 : 4 to 20 mA output × 2, status output or pulse output (selectable) × 2 (total 4 points) See "Converter code" on page 14 for details.
- Low cut-off: Current output and pulse output (can be set separately for each indication) Range : 0 to 20% F.S. (0.1% step) Hysteresis : 0 to 5% F.S. (0.1% step)
- Time constant: Current output and pulse output (can be set separately for each indication) Range : 0.0 to 100.0 sec (0.1 sec step) Standard functions
- User-defined measuring units : Units for mass, volume, and time can be defined (max. 7 letters).
- Bi-directional flow measurement : Flow rates in both directions can be measured. Flow direction is output as status output.
- Self-diagnosis : Error messages and status messages are displayed. Function : CPU, memory, software, hardware, output connection Status : Over-range, count-over, power failure Application : Oscillating balance of measuring tube, vibration energy, other sensor circuit diagnosis
- Testing : Built-in simulator of current and pulse outputs Allows for loop check without calibrator.
- Touch sensor (optical key) : Four touch sensors enable data to be set from outside without the need for opening the cover. These serve as push buttons while the cover is opened. 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube 2 TOKYO KEISO CO., LTD.
- Mass flow rate (pulse output) Measuring tube material T H/S/A Measuring tube Titanium Hastelloy® C22, Stainless Steel, Tantalum Accuracy ±0.1% of reading Zero stability ±0.004% of max. flow rate ±0.015% of max. flow rate
- Reference conditions: Water at 20°C, 0.1 MPa Flow rate (% of max. flow rate) Accuracy (±% of reading) Measurement error (accuracy + zero stability) ̩Titanium tube ̝Hastelloy®C22 tube ̨Stainless Steel tube ̖Tantalum tube Accuracy (±% of reading) Measuring tube material T H/S/A Measuring tube Titanium Hastelloy® C22, Stainless Steel, Tantalum % of max. flow rate 100 % 0.104 0.115 50 % 0.108 0.130 20 % 0.12 0.175 10 % 0.14 0.25 5 % 0.18 0.4 1 % 0.5 1.6 0.77 % 0.62 2.04 Note: Accuracy is not assured for flow rates less than 0.77% of max. flow rate (meaning less than min. flow rate). Effects of changes in process conditions: Fluid temperature ; ±0.001% (Titanium) / ±0.004% (others) of max. flow rate per 1°C Example when the size changes by 1°C with size T06 (Titanium): 1230 kg /h × 0.00001ʹ0.0123 kg/h Fluid pressure ; ±0.011% of max. flow rate per 0.1 MPa These effects should be considered when process conditions change after zero adjustment.
- Density (Indicated value) Measuring tube material TH / S / A Measuring tube Titanium Hastelloy® C22, Stainless Steel, Tantalum Meter size applicable to density measurement 15, 25, 40, 50, 80 Measuring range 400 to 2000 kg/m 3 Accuracy *1 ±2kg/m3 Accuracy (on-site calibration) ±0.5kg/m3 $BMJCSBUJPOXJUIDFSUJGJDBUJPOBUUIFGBDUPSZUFTUUPCF QFSGPSNFEBTBOPQUJPO 5BOUBMVNJTOPUBWBJMBCMFGPSTJ[F (calibrated at the factory)
- Temperature (indicated value) Measuring tube material TH / S / A Measuring tube Titanium Hastelloy® C22, Stainless Steel, Tantalum Measuring range –40 to +150°C 0 to +100°C Accuracy ±1 ˆ 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 3
- Japanese standard explosionproof Type of protection and class: Compact type MMM7400RC-JEx (Certificate number: CML21JPN1739X, CML21JPN21175X) Ex db ia IIC T6...T1 Ga/Gb Ex db eb ia IIC T6...T1 Ga/Gb Ex tb IIIC T165°C Db Remote type sensor MMS7000RF-JEx (Certificate number: CML21JPN2904X, CML21JPN21181X) Ex ia IIC T6...T1 Ga Ex ia IIIC T165°C Da Remote type converter MMC400RF-JEx (Certificate number: CML21JPN1740X, CML21JPN21182X) Ex db [ia] IIC T6 Gb Ex db eb [ia] IIC T6.Gb Ex tb IIIC T75°C Db Compact type MMM7400RC-JEx (Japanese standard explosionproof) Compact type MMM7400C-Ex (ATEX/IECEx explosionproof) Aluminum alloy converter housing (standard) Ambient temperature °C Fluid temperature °C Temperature class Max. surface temperature °C –40 to +40
65 T6–T1 T80
80 T5–T1 T95
100 T4–T1 T115
115 T4–T1 T130
150 T3–T1 T165
–40 to +50 –40 to +65 65 T4–T1 T80 Stainless Steel converter housing (optional) Ambient temperature °C Fluid temperature °C Temperature class Max. surface temperature °C –40 to +40
130 T3–T1 T145
–40 to +50
80 T4–T1 T95
115 T3–T1 T130
–40 to +65 60 T4–T1 T75 Remote type MMS7000RF-JEx (Japanese standard explosionproof) Remote type MMS7000F-Ex (ATEX/IECEx explosionproof) Aluminum alloy housing with heating jacket Ambient temperature °C Fluid temperature °C 5FNQFSBUVSF DMBTT Max. surface temperature °C rUP 5r5 5 5r5 5 5r5 5 5r5 5 5r5 5 rUP 5r5 5 5r5 5 5r5 5 5r5 5 rUP 5r5 5 5r5 5 5r5 5
- ATEX explosionproof Type of protection and class: Compact type MMM7400C-Ex (Certificate number: PTB17 ATEX2008 X) II 1/2(1)G Ex db ia [ia Ga] IIC T6...T1 Ga/Gb or II 1/2(1)G Ex db eb ia [ia Ga] IIC T6...T1 Ga/Gb or II 1/2 G Ex db ia IIC T6...T1 Ga/Gb II 1/2 G Ex db ea ia IIC T6...T1 Ga/Gb II 2(1)D Ex tb [ia Da] IIIC Txxx°C Db or II 2D Ex tb IIIC Txxx°C Db Remote type sensor MMS7000F-Ex (Certificate number: PTB17 ATEX 2007 X) II 1 G Ex ia IIC T6...T1 Ga or II 1 D Ex ia IIIC Txxx°C Da Remote type converter MMC400F-Ex (Certificate number: PTB17 ATEX 2009 X) II 2(1) G Ex db [ia Ga] IIC T6 Gb II 2(1)G Ex db eb [ia Ga] IIC T6 Gb or II 2 G Ex db[ia] IIC T6 Gb or II 2 G Ex db eb [ia] IIC T6 Gb or II 2(1)D Ex tb [ia Da] IIIC T75°C Db or II 2D Ex tb IIIC T75°C Db
- IECEx explosionproof Type of protection and class: Compact type MMM7400C-Ex (Certificate number: IECEx PTB17.0029X) Ex db ia [ia Ga] IIC T6...T1 Ga/Gb or Ex db eb ia [ia Ga] IIC T6...T1 Ga/Gb or Ex ia IIC T6...T1 Ga/Gb or Ex eb ia IIC T6...T1 Ga/Gb or Ex tb [ia Da] IIIC Txxx°C Db or Ex tb IIIC Txxx°C Db Remote type sensor MMS7000F-Ex (Certificate number: IECEx PTB17.0028X) Ex ia IIC T6...T1 Ga or II 1 D Ex ia IIIC Txxx°C Da Remote type converter MMC400F-Ex (Certificate number: IECEx PTB17.0030X) Ex db [ia Ga] IIC T6 Gb Ex db eb [ia Ga] IIC T6 Gb or Ex db[ia] IIC T6 Gb or Ex db eb [ia] IIC T6 Gb or Ex tb [ia Da] IIIC T75°C Db or Ex tb IIIC T75°C Db 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube 4 TOKYO KEISO CO., LTD.
Pressure and temperature rating table [Rating table for Titanium measuring tube] ņņ ņ ņ ņ ņņ ņņ ņ ņņJIS10K Flange Temperature (°C) ASME CL150 Flange JIS20K Flange ASME CL300 Flange 6.3MPaG, conforming to PED [Outer cylinder: SS304/304L (Standard)] ASME CL600 Flange [Outer cylinder: SS304/304L (Standard), Non-PED] [Outer cylinder: SS316/316L (Optional), conforming to PED] Sizes: 40 to 80 Sizes: 06 to 25 Pressure (MPa) Note: Consult us for other flange standards. [Rating table for Hastelloy ® C22, Stainless Steel, and Tantalum measuring tubes] JIS10K Flange Temperature (°C) ASME CL150 Flange JIS20K Flange ASME CL300 Flange 6.3MPaG, conforming to PED [Outer cylinder: SS304/304L (Standard)] Pressure (MPa) Note: Consult us for other flange standards. 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 5
ʤCompact typeʥ Converter Sensor Outer cylinder (protective housing) Cable entry Flange Input/ output Power supply FLOW RANGE Meter size kg/h kg/min Max. flow rate Min. flow rate Max. flow rate Min. flow rate 06 1,230 12 20.5 0.205 10 3,500 35 58.3 0.583 15 14,600 146 243.3 2.433 25 44,800 448 746.7 7.467 40 120,000 1,200 2,000 20 50 234,000 2,340 3,900 39 80 560,000 5,600 9,333 93.33 Note: The measuring tubes of Hastelloy ® C22 are available for sizes 10 to 80 (mm), Tantalum for sizes 10 to 50 (mm) and Stainless Steel for sizes 06 to 50 (mm). MEASURING TUBE DIMENSIONS Meter size Measuring tube material Dimensions (mm) Inside diameter Wall thickness T 5 . 5 3 0 . 4 1 H ʵʵ S 5 . 5 3 0 . 4 1 T 8 . 5 6 0 . 6 0 H 8 . 4 1 0 . 5 6 S 8 . 4 0 0 . 5 6 T 14.8 0.60 H/A 14.96 0.46 S1 4 . 9 6 0 . 4 6 T2 3 . 9 8 0 . 7 1 S2 4 . 8 5 0 . 5 5 T3 6 . 2 8 0 . 9 1 H/A 36.68 0.71 S3 6 . 6 8 0 . 7 1 T4 8 . 3 2 1 . 2 4 H/A 48.80 1.00 S4 8 . 2 6 1 . 0 0 T6 8 . 8 0 2 . 1 0 H7 0 . 9 5 1 . 0 4 S ʵʵ 55JUBOJVN ))BTUFMMPZ$ 44UBJOMFTT4UFFM "5BOUBMVN PROCESS CONNECTION
- Flange connection Meter size Standard Optional Equiv. to JIS *1 Equiv. to ASME Equiv. to JIS/ASME *2 10A 20K 1/2" class 150 15A 20K 1/2" class 300,60010 15 15A 20K 3/4" class 150 25A 20K 3/4" class 300, 600 1" class 150, 300, 600 25 25A 20K 1" class 150 40A 20K 1" class 300, 600 1-1/2" class 150, 300, 600 40 40A 20K 1-1/2" class 150 50A 10K 1-1/2" class 300, 600 2" class 150, 300, 600 50 50A 10K 2" class 150 80A 10K 2" class 300, 600 3" class 150, 300, 600 ˎ3 80 80A 10K 3" class 150 100A 10K *3 3" class 300, 600 4" class 150, 300, 600 *3 *1 JIS20K flange is commonly used for 10A 10K to 40A 10K flange as standard. (Installation dimensions of JIS20K flange are equal to JIS10K except the flange thickness.) *2 ASME Class 600 flanges are provided only for material "T" (Titanium tube). *3 For sizes 50 and 80 mm, one rank larger flange connection is available only for Titanium tubes.
- Sanitary fitting (Optional) Meter size Fittings 06 1/2" Tri-clamp 10 1/2" Tri-clamp 15 1" ISO 2852 ferrule (IDF ferrule compliant) 1" Tri-clamp 25 1-1/2" ISO 2852 ferrule (IDF ferrule compliant) 1-1/2" Tri-clamp 40 2" ISO 2852 ferrule (IDF ferrule compliant) 2" Tri-clamp 50 3" ISO 2852 ferrule (IDF ferrule compliant) 3" Tri-clamp 80 3" ISO 2852 ferrule (IDF ferrule compliant) 3" Tri-clamp *4 Sanitary fitting is provided only for material "T" (Titanium tube) and "S" (Stainless Steel UNS S31803 tube). PRESSURE LOSS [TYPICAL VALUE] Flow rate (% of nominal flow rate) Pressure loss (MPa) Liquid conditions Viscosity: 1 mPa∙s Density: 1000 kg/m 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube 6 TOKYO KEISO CO., LTD.
ᶃWhen installing the flowmeter on the horizontal line, place the converter or the terminal box of remote type above the measuring tube. ᶅWhen installing the flowmeter on the slant line with upward flow, place the converter or the terminal box of remote type above the measuring tube. ᶇWhen installing the flowmeter on the vertical line, provide with stop valves at both upstream and downstream to keep the flowmeter to be filled with liquids, which is necessary to perform zero adjustment. ᶉInstall a control valve downstream if required to avoid the cavitations caused by throttling of valve. ᶄWhen installing the flowmeter on the vertical line, install it in upward flow direction. ᶆ When installing the flowmeter on the horizontal line, make the upstream and downstream pipings be filled with liquids. Do not bend these pipings downward at the vicinity of flowmeter. To avoid unnecessary accumulation of gasses, do not install the flowmeter on the upper part of associated pipings in such processes containing air or gas. ᶈIt is highly recommended to equip with bypass and stop valves for mainte- nance purpose. 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 7
[I/O terminals of MMC400RC/F converters]
- Current output × 1, pulse output × 1, status output × 1, control input × 1 (standard output) The power supply terminal block has a protection cover. Protection cover Terminals Description L / L+ L and N for AC power supply L+ and L− for DC power supplyN / LŖ Grounding Terminals Polarity Description (Standard) DŖŖ Pulse or status output, frequency pulse, alarm outputD+ CŖŖ Current output (4 to 20 mA/internal power supply)C+ BŖ B AŖ A
- Terminal type : Plug-in type screw terminal
- Wire cross section : 0.5 to 2.5 mm 2
- Cable outside diameter : 7 to 12 mm
- Connection diagram for optional outputs (modular I/O print circuit) Converter specifications Polarity 0QUJPO $VSSFOU PVUQVU QVMTF PSTUBUVT PVUQVU DPOUSPM JOQVU &, 0QUJPO $VSSFOU PVUQVUʷ QVMTF PSTUBUVT PVUQVU 0QUJPO $VSSFOU PVUQVUʷ QVMTF PSTUBUVT PVUQVU 0QUJPO $VSSFOU PVUQVUʷ QVMTF PSTUBUVT PVUQVUʷ Terminal DŖ Ŗ 1VMTFPS TUBUVTPVUQVU GSFRVFODZ QVMTF BMBSN PVUQVU 1VMTFPS TUBUVT PVUQVU 1VMTFPS TUBUVT PVUQVU 1VMTFPS TUBUVT PVUQVU CŖŖ $VSSFOU PVUQVU $VSSFOU PVUQVU $VSSFOU PVUQVU $VSSFOU PVUQVU /PC+ BŖŖ $POUSPMJOQVU $VSSFOU PVUQVU 1VMTFPS TUBUVT PVUQVU AŖŖ 4UBUVTPVUQVU PSQVMTF GSFRVFODZ QVMTF BMBSN PVUQVU $VSSFOU PVUQVU $VSSFOU PVUQVU $VSSFOU PVUQVU /PA+ Remote type sensor cable MMS7000RF + MMC400RF ..$3'DPOWFSUFS w5FSNJOBMUZQF4QSJOHDMBNQ w$BCMF%FEJDBUFE ɹ5FSNJOBMCMPDL ᶄ$BCMFHMBOE ᶅ$BCMFGBTUFOJOHHSJQ GPSHSPVOEJOH %FEJDBUFETFOTPSDBCMF wDPSFDPNQPVOEDBCMF XJUINN DPOEVDUPS w0VUTJEFEJBNFUFS "QQSPYNN w.BYMFOHUIN ..43'TFOTPS w5FSNJOBMUZQF 4QSJOHDMBNQ w$BCMF%FEJDBUFE ᶃ ᶅ ᶄ ᶅ ᶄ ᶃ 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube 8 TOKYO KEISO CO., LTD.
- MMM7400RC compact type with flange connection П Ї - - 'MPXEJSFDUJPOBTTUBOEBSE ) ) " " Meter size Dimensions (mm) Approx. mass (kg) Material Tantalum additional mass (approx. kg) LA HH 1 H 2 H 3 ПDL1 L2 A1 A2 06 420 — 335 — 362 51 241 311 102 18.5 — 10 510 557 413 — 362 51 241 311 102 23 1.8 15 548 633 450 525 362 51 241 311 102 26 2.7 25 700 800 598 688 376 58 248 318 115 37 4.5 40 925 1075 796 936 430 85 275 345 170 83 9.2 50 1101 1281 948 1118 480 110 300 370 220 147 15.1 80 1460 — 1274 — 534 137 327 397 274 265 — 1. Face-to-face dimension "L " is for standard flange. "L1" and "A1" are for Titanium, Hastelloy ® C22 and Stainless Steel while "L2" and "A2" are for Tantalum. 2. "H" and "H1" are the height from the bottom of the outer cylinder. 3. Length "G": 26 mm for G1/2 female adapter and 1/2 NPT female adapter. 85 mm for Japanese standard explosionproof construction. 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 9
- MMS7000RF remote type sensor with flange connection Meter size Dimensions (mm) Approx. mass (kg)LA HH 1 H 3 ПDL1 L2 A1 A2 06 420 — 335 — 282 51 231 102 15.7 10 510 557 413 — 282 51 231 102 20.2 15 548 633 450 525 282 51 231 102 23.2 25 700 800 598 688 295 58 237 115 34.2 40 925 1075 796 936 350 85 265 170 80.2 50 1101 1281 948 1118 400 110 290 220 144.2 80 1460 — 1274 — 454 137 317 274 262.2 1. Face-to-face dimension "L " is for standard flange. "L1" and "A1" are for Titanium, Hastelloy ® C22 and Stainless Steel while "L2" and "A2" are for Tantalum. 2. "H" and "H1" are the height from the bottom of the outer cylinder. - - " " 'MPXEJSFDUJPOBTTUBOEBSE
- MMC400RF remote type converter Ї Ї Ї Ї Optional U bolt for 2" pipe installation 2" pipe supplied by customers .BTT "QQSPYLH -FOHUI( NNGPS(GFNBMFBEBQUFSBOE/15GFNBMFBEBQUFS NNGPS+BQBOFTFTUBOEBSEFYQMPTJPOQSPPGDPOTUSVDUJPO 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube 10 TOKYO KEISO CO., LTD.
- MMM7400RC compact type with sanitary connection Meter size Dimensions (mm) Approx. mass (kg)AH H 1 H 2 H 3 ПD 06 335 362 51 241 311 102 18.5 10 413 362 51 241 311 102 23 15 450 362 51 241 311 102 26 25 598 376 58 248 318 115 37 40 796 430 85 275 345 170 83 50 948 480 110 300 370 220 147 80 1274 534 137 327 397 274 265 1. "H" and "H1" are the height from the bottom of the outer cylinder. 2. Length "G": 26 mm for G1/2 female adapter and 1/2 NPT female adapter. 85 mm for Japanese standard explosionproof construction. Meter size Model Fittings L (mm)
06 KR 1/2" Tri-clamp (welding type) 480
10 KR 1/2" Tri-clamp (welding type) 558
15 MS 1" Tri-clamp (adapter type) 665
MU 1" ISO 2852 ferrule (adapter type, IDF-compliant) 665 NR 1-1/2" Tri-clamp (welding type) 816 NS 1-1/2" Tri-clamp (adapter type) 855 NT 1-1/2" ISO 2852 ferrule (welding type, IDF-compliant) 816 NU 1-1/2" ISO 2852 ferrule (adapter type, IDF-compliant) 855 PR 2" Tri-clamp (welding type) 1043 PS 2" Tri-clamp (adapter type) 1077 PT 2" ISO 2852 ferrule (welding type, IDF-compliant) 1043 PU 2" ISO 2852 ferrule (adapter type, IDF-compliant) 1077 RR 3" Tri-clamp (welding type) 1305 RS 3" Tri-clamp (adapter type) 1355 RT 3" ISO 2852 ferrule (welding type, IDF-compliant) 1305 RU 3" ISO 2852 ferrule (adapter type, IDF-compliant) 1355
80 RR 3" Tri-clamp (welding type) 1527
RT 3" ISO 2852 ferrule (welding type, IDF-compliant) 1527 Note: Sanitary fitting is provided only for material "T" (Titanium tube) and "S" (Stainless Steel UNS S31803 tube). П Ї - - 'MPXEJSFDUJPOBTTUBOEBSE ) ) " " 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 11
- MMM7400RC remote type with sanitary connection - - " " 'MPXEJSFDUJPOBTTUBOEBSE Meter size Dimensions (mm) Approx. mass (kg)AH H 1 H 3 ПD 06 335 282 51 231 102 15.7 10 413 282 51 231 102 20.2 15 450 282 51 231 102 23.2 25 598 295 58 237 115 34.2 40 796 350 85 265 170 80.2 50 948 400 110 290 220 144.2 80 1274 454 137 317 274 262.2 1. "H" and "H1" are the height from the bottom of the outer cylinder. 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube 12 TOKYO KEISO CO., LTD.
MODEL AND SPECIFICATION CODES Measuring tube material: "T" Titanium (standard) [Model code] Specifications Compact type (Sensor + Converter) Remote type Sensor Converter General purpose (non explosionproof) MMM7400RC-T □□ MMS7000RF-T □□ MMC400RF Japanese standard explosionproof MMM7400RC-JEx-T □□ MMS7000RF-JEx-T □□ MMC400RF-JEx ATEX / IECEx explosionproof MMM7400C-Ex-T □□ MMS7000F-Ex-T □□ MMC400F-Ex Note: □□: 06 to 80 are assigned as size codes. [Sensor code] Sensor Spec. Code VE 4 T 0 Description Std. Sensor Code VE MMS 7000R Sensor (Single Straight Measuring Tube) ○ Meter Size 11 Meter Size 06 ○
12 Meter Size 10 ○
13 Meter Size 15 ○
14 Meter Size 25 ○
15 Meter Size 40 ○
16 Meter Size 50 ○
17 Meter Size 80 ○
(Fixed code) 4 Always 4 ○ : Standard ˚: Semi-standard ˛: Option Measuring Tube Material T Titanium ○ Measuring Tube Surface Finish 0 Standard ○ 1 Polished Ra = 0.5μm (only for sanitary connection) Meter Size 2 Polished Ra = 0.8μm (only for sanitary connection) 06 10 15 25 40 50 80 Process connection TH 10A JIS20K ○○ ʵʵʵʵʵ ○ UH 15A JIS20K ˛˛ ○ ʵʵʵʵ ○ VH 25A JIS20K ʵʵ˛ ○ ʵʵʵ ○ WH 40A JIS20K ʵʵʵ˛ ○ ʵʵ ○ XG 50A JIS10K ʵʵʵʵ˛ ○ ʵ ○ XH 50A JIS20K ʵʵʵʵ˛˛ʵ YG 80A JIS10K ʵʵʵʵʵ˛ ○○ YH 80A JIS20K ʵʵʵʵʵ˛˛ ZG 100A JIS10K ʵʵʵʵʵʵ˛ ZH 100A JIS20K ʵʵʵʵʵʵ˛ KD 1/2" ASME class 150 (min. temperature -20°C for Size 15) ˚˚˚ʵʵʵʵ KE 1/2" ASME class 300 (min. temperature -20°C for Size 15) ˛˛˛ʵʵʵʵ KF 1/2" ASME class 600 (min. temperature -20°C for Size 15) ˛˛˛ʵʵʵʵ LD 3/4" ASME class 150 ʵʵ˚ʵʵʵʵ LE 3/4" ASME class 300 ʵʵ˛ʵʵʵʵ LF 3/4" ASME class 600 ʵʵ˛ʵʵʵʵ MD 1" ASME class 150 ʵʵ˛˚ʵʵʵ ME 1" ASME class 300 ʵʵ˛˛ʵʵʵ MF 1" ASME class 600 ʵʵ˛˛ʵʵʵ ND 1-1/2" ASME class 150 ʵʵʵ˛˚ʵʵ NE 1-1/2" ASME class 300 ʵʵʵ˛˛ʵʵ NF 1-1/2" ASME class 600 ʵʵʵ˛˛ʵʵ PD 2" ASME class 150 ʵʵʵʵ˛˚ʵ PE 2" ASME class 300 ʵʵʵʵ˛˛ʵ PF 2" ASME class 600 ʵʵʵʵ˛˛ʵ RD 3" ASME class 150 ʵʵʵʵʵ˛˚ RE 3" ASME class 300 ʵʵʵʵʵ˛˛ RF 3" ASME class 600 ʵʵʵʵʵ˛˛ SD 4" ASME class 150 ʵʵʵʵʵʵ˛ SE 4" ASME class 300 ʵʵʵʵʵʵ˛ SF 4" ASME class 600 ʵʵʵʵʵʵ˛ KR 1/2" Tri-clamp (welding type) ˛˛ʵʵʵʵʵ LR 3/4" Tri-clamp (welding type) ʵʵ˛ʵʵʵʵ MU 1" ISO 2852 ferrule (adapter type) ʵʵ˛ʵʵʵʵ NR 1-1/2" Tri-clamp (welding type) ʵʵʵ˛ʵʵʵ NS 1-1/2" Tri-clamp (adapter type) ʵʵʵ˛ʵʵʵ NT 1-1/2" ISO 2852 ferrule (welding type) ʵʵʵ˛ʵʵʵ NU 1-1/2" ISO 2852 ferrule (adapter type) ʵʵʵ˛ʵʵʵ PR 2" Tri-clamp (welding type) ʵʵʵʵ˛ʵʵ PS 2" Tri-clamp (adapter type) ʵʵʵʵ˛ʵʵ PT 2" ISO 2852 ferrule (welding type) ʵʵʵʵ˛ʵʵ PU 2" ISO 2852 ferrule (adapter type) ʵʵʵʵ˛ʵʵ RR 3" Tri-clamp (welding type) ʵʵʵʵʵ˛˛ RS 3" Tri-clamp (adapter type) ʵʵʵʵʵ˛ʵ RT 3" ISO 2852 ferrule (welding type) ʵʵʵʵʵ˛˛ RU 3" ISO 2852 ferrule (adapter type) ʵʵʵʵʵ˛ʵ (Fixed code) 0 Always 0 ○ Outer Cylinder Material * G SS304/304L dual certified ○ H SS304/304L dual certified 0 SS304/304L dual certified PED-certified, Max. 6.3 MPa at 20°C A SS316/316L dual certified PED-certified, Max. 6.3 MPa at 20°C B SS316/316L dual certified PED-certified, Max. 10 MPa at 20°C Heating Jacket 0 Without ○
2 Heating jacket with 1/2 NPT female (not available for size 06)
Explosionproof Approvals 0 Without
1 ATEX explosionproof (Ex) ○
R IECEx explosionproof (Ex)
9 Japanese standard explosionproof (JEx)
*1 "Measuring tube surface finish Ra = 0.8 μm" is mandatory
0 Without ○
1 EHEDG (European Hygienic Equipment Design Group) *1
2 3A (American Dairy Approval) *1 Type 0 Compact type ○
1 Remote type (aluminum alloy wiring terminal housing)
2 Remote type (stainless steel wiring terminal housing)
Calibration 0 Standard 3-point flow calibration ○ 1 5-point fow calibration A 3-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 80 B 5-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 80 D 5-point flow calibration + UKAS-certified calibration (ISO/IEC 17025) Degreasing 0 Without ○
1 Degreasing wetted parts
Special specifications 00 Without 00/Z Special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eries Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 13
[Converter code] MMC400RC/RF Converter spec. code VE 54 4 2 0 0 2 0 0 Description Std. Converter code VE 54 MMC400R converter ○ (Fixed code) 4 Always 4 ○ Type 4 Compact type ○ H Remote type (mandatory for ship class, high temperature, and cryogenic models) Power supply A 100 to 230 V AC ○ 1 12 to 24 V DC Explosionproof Approval 0 Without ○
1 ATEX explosionproof (Ex)
F IECEx explosionproof (Ex) Cable entries for input, output, and power supply 0 M20 × 1.5 female for ATEX explosionproof 4 1/2 NPT female adapter
5 G1/2 female adapter ○
6 M20 × 1.5 with waterproof gland
9 G1/2 flameproof gasket adapter for Japanese standard explosionproof
Language for indication 2 English ○ (Fixed code) 0 0 Always 00 ○ Converter housing 1 Aluminum alloy ○
2 SS316L (compact type)
3 SS316L (remote type)
(Fixed code) 2 Always 2 ○ Output 6 0 0 4 to 20 mA × 1, pulse or status × 1, total 2 ○
6 E K 4 to 20 mA × 1, pulse × 1, status × 1, control input × 1
6 A 8 4 to 20 mA × 2, pulse or status × 1 (selectable)
6 A A 4 to 20 mA × 3, pulse or status × 1 (selectable)
6 A E 4 to 20 mA × 2, pulse × 1, pulse or status × 1 (selectable)
Measurement 0 Mass flow rate, density, temperature as standard ○ (Fixed code) 0 Always 0 ○ Sensor cable 0 Without (compact type) ○ 4 5 m cable (only for remote type) 1 10 m cable (only for remote type) 5 20 m cable (only for remote type) Special specifications 00 Without 00/Z Special Note: Special requirements not included in the above coding system should be designated by adding "/Z" at the end of the code. Consult us for the availability of such requirements before ordering. 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube 14 TOKYO KEISO CO., LTD.
Measuring tube material: "H" Hastelloy® C22 (optional) [Model code] Specifications Compact type (Sensor + Converter) Remote type Sensor Converter General purpose (non explosionproof) MMM7400RC-H □□ MMS7000RF-H □□ MMC400RF Japanese standard explosionproof MMM7400RC-JEx-H □□ MMS7000RF-JEx-H □□ MMC400RF-JEx ATEX / IECEx explosionproof MMM7400C-Ex-H □□ MMS7000F-Ex-H □□ MMC400F-Ex Note: □□: 10 to 80 are assigned as size codes. [Sensor code] Sensor Spec. Code VE 4 H 0 0 Description Std. Sensor Code VE MMS 7000R Sensor (Single Straight Measuring Tube) ○ Meter Size 32 Meter Size 10 ○
33 Meter Size 15 ○
34 Meter Size 25 ○
35 Meter Size 40 ○
36 Meter Size 50 ○ : Standard
˚ : Semi-standard ˛ : Option
37 Meter Size 80 ○
(Fixed code) 4 Always 4 ○ Measuring Tube Material H Hastelloy ®C22 Meter Size ○ Measuring Tube Surface Finish 0 Standard 10 15 25 40 50 80 ○ Process connection TH 10A JIS20K ○ ʵʵʵʵʵ ○ UH 15A JIS20K ˛ ○ ʵʵʵʵ ○ VH 25A JIS20K ʵ˛ ○ ʵʵʵ ○ WH 40A JIS20K ʵʵ˛ ○ ʵʵ ○ XG 50A JIS10K ʵʵʵ˛ ○ ʵ ○ XH 50A JIS20K ʵʵʵ˛˛ʵ YG 80A JIS10K ʵʵʵʵʵ ○○ YH 80A JIS20K ʵʵʵʵʵ˛ KD 1/2" ASME class 150 ˚˚ʵʵʵʵ KE 1/2" ASME class 300 ˛˛ʵʵʵʵ LD 3/4" ASME class 150 ʵ˚ʵʵʵʵ LE 3/4" ASME class 300 ʵ˛ʵʵʵʵ MD 1" ASME class 150 ʵ˛˚ʵʵʵ ME 1" ASME class 300 ʵ˛˛ʵʵʵ ND 1-1/2" ASME class 150 ʵʵ˛˚ʵʵ NE 1-1/2" ASME class 300 ʵʵ˛˛ʵʵ PD 2" ASME class 150 ʵʵʵ˛˚ʵ PE 2" ASME class 300 ʵʵʵ˛˛ʵ RD 3" ASME class 150 ʵʵʵʵʵ˚ RE 3" ASME class 300 ʵʵʵʵʵ˛ (Fixed code) 0 Always 0 ○ Outer Cylinder Material * G SS304/304L dual certified ○ H SS316/316L dual certified 0 SS304/304L dual certified PED-certified, Max. 6.3 MPa at 20°C A SS316/316L dual certified PED-certified, Max. 6.3 MPa at 20°C Heating Jacket 0 Without ○
2 Heating jacket with 1/2 NPT female (for Sizes 10 to 80)
Explosionproof Approvals 0 Without ○ R IECEx explosionproof (Ex) Sanitary Approvals 0 Without ○ Type 0 Compact type ○ Calibration 0 Standard 3-point flow calibration ○ 1 5-point fow calibration A 3-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 80 B 5-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 80 D 5-point flow calibration + UKAS-certified calibration (ISO/IEC 17025) Degreasing 0 Without ○ Special specifications 00 Without 00/Z Special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eries Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 15
Measuring tube material: "S" Stainless Steel UNS S31803 (optional) [Model code] Specifications Compact type (Sensor + Converter) Remote type Sensor Converter General purpose (non explosionproof) MMM7400RC-S □□ MMS7000RF-S □□ MMC400RF Japanese standard explosionproof MMM7400RC-JEx-S □□ MMS7000RF-JEx-S □□ MMC400RF-JEx ATEX/IECEx explosionproof MMM7400C-Ex-S □□ MMS7000F-Ex-S □□ MMC400F-Ex Note: □□: 06 to 50 are assigned as size codes. [Sensor code] Sensor Spec. Code VE 4 S 0 Description 4UE Sensor Code VE MMS 7000R Sensor (Single Straight Measuring Tube) ○ Meter Size 21 Meter Size 06 ○
22 Meter Size 10 ○
23 Meter Size 15 ○
24 Meter Size 25 ○
25 Meter Size 40 ○
26 Meter Size 50 ○
(Fixed code) 4 Always 4 ○ : Standard ˚ : Semi-standard ˛ : Option Measuring Tube Material S Stainless Steel UNS S31803 ○ Measuring Tube Surface Finish 0 Standard ○ 1 Polished Ra = 0.5μm (only for sanitary connection) Meter Size 2 Polished Ra = 0.8μm (only for sanitary connection) 06 10 15 25 40 50 Process connection TH 10A JIS20K ○○ ʵʵʵʵ ○ UH 15A JIS20K ˛˛ ○ ʵʵʵ ○ VH 25A JIS20K ʵʵ˛ ○ ʵʵ ○ WH 40A JIS20K ʵʵʵ˛ ○ ʵ ○ XG 50A JIS10K ʵʵʵʵ˛ ○○ XH 50A JIS20K ʵʵʵʵ˛˛ KD 1/2" ASME class 150 ˚˚˚ʵʵʵ KE 1/2" ASME class 300 ˛˛˛ʵʵʵ LD 3/4" ASME class 150 ʵʵ˚ʵʵʵ LE 3/4" ASME class 300 ʵʵ˛ʵʵʵ MD 1" ASME class 150 ʵʵ˛˚ʵʵ ME 1" ASME class 300 ʵʵ˛˛ʵʵ ND 1-1/2" ASME class 150 ʵʵʵ˛˚ʵ NE 1-1/2" ASME class 300 ʵʵʵ˛˛ʵ PD 2" ASME class 150 ʵʵʵʵ˛˚ PE 2" ASME class 300 ʵʵʵʵ˛˛ KR 1/2" Tri-clamp (welding type) ˛˛ʵʵʵʵ LR 3/4" Tri-clamp (welding type) ʵʵ˛ʵʵʵ MU 1" ISO 2852 ferrule (adapter type) ʵʵ˛ʵʵʵ NR 1-1/2" Tri-clamp (welding type) ʵʵʵ˛ʵʵ NS 1-1/2" Tri-clamp (adapter type) ʵʵʵ˛ʵʵ NT 1-1/2" ISO 2852 ferrule (welding type) ʵʵʵ˛ʵʵ NU 1-1/2" ISO 2852 ferrule (adapter type) ʵʵʵ˛ʵʵ PR 2" Tri-clamp (welding type) ʵʵʵʵ˛ʵ PS 2" Tri-clamp (adapter type) ʵʵʵʵ˛ʵ PT 2" ISO 2852 ferrule (welding type) ʵʵʵʵ˛ʵ PU 2" ISO 2852 ferrule (adapter type) ʵʵʵʵ˛ʵ RR 3" Tri-clamp (welding type) ʵʵʵʵʵ˛ RS 3" Tri-clamp (adapter type) ʵʵʵʵʵ˛ RT 3" ISO 2852 ferrule (welding type) ʵʵʵʵʵ˛ RU 3" ISO 2852 ferrule (adapter type) ʵʵʵʵʵ˛ (Fixed code) 0 Always 0 ○ Outer Cylinder Material * G SS304/304L dual certified ○ H SS316/316L dual certified 0 SS304/304L dual certified PED-certified, Max. 6.3 MPa at 20°C A SS316/316L dual certified PED-certified, Max. 6.3 MPa at 20°C Heating Jacket 0 Without ○
2 Heating jacket with 1/2 NPT female (for Sizes 15 to 50)
Explosionproof Approvals 0 Without ○ R IECEx explosionproof (Ex) *1 "Measuring tube surface finish Ra = 0.8 μm" is mandatory *2 "Measuring tube surface finish Ra = 0.5 μm" is mandatory
1 EHEDG (European Hygienic Equipment Design Group)
2 3A (American Dairy Approval) *1
3 ASME Bioprocessing Equipment Standard *2
Type 0 Compact type ○ Calibration 0 Standard 3-point flow calibration ○ 1 5-point fow calibration A 3-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 50 B 5-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 50 D 5-point flow calibration + UKAS-certified calibration (ISO/IEC 17025) Degreasing 0 Without ○ Special specifications 00 Without 00/Z Special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eries Coriolis Mass Flowmeter with Single Straight Measuring Tube 16 TOKYO KEISO CO., LTD.
Measuring tube material: "A" Tantalum (optional) [Model code] Specifications Compact type (Sensor + Converter) Remote type Sensor Converter General purpose (non explosionproof) MMM7400RC-A □□ MMS7000RF-A □□ MMC400RF Japanese standard explosionproof MMM7400RC-JEx-A □□ MMS7000RF-JEx-A □□ MMC400RF-JEx ATEX/IECEx explosionproof MMM7400C-Ex-A □□ MMS7000F-Ex-A □□ MMC400F-Ex Note: □□: 10 to 50 are assigned as size codes. [Sensor code] Sensor Spec. Code VE 4 A 0 0 Description 4UE Sensor Code VE MMS 7000R Sensor (Single Straight Measuring Tube) ○ Meter Size 32 Meter Size 10 ○
35 Meter Size 40 ○ : Standard
˚ : Semi-standard ˛ : Option
36 Meter Size 50 ○
(Fixed code) 4 Always 4 ○ Measuring Tube Material A Tantalum Meter size ○ Measuring Tube Surface Finish 0 Standard 10 15 25 40 50 ○ Process connection TH 10A JIS20K ○ ʵʵʵʵ ○ UH 15A JIS20K ˛ ○ ʵʵʵ ○ VH 25A JIS20K ʵ˛ ○ ʵʵ ○ WH 40A JIS20K ʵʵ˛ ○ ʵ ○ XG 50A JIS10K ʵʵʵ˛ ○○ KD 1/2" ASME class 150 ˚˚ʵʵʵ KE 1/2" ASME class 300 ˛˛ʵʵʵ LD 3/4" ASME class 150 ʵ˚ʵʵʵ LE 3/4" ASME class 300 ʵ˛ʵʵʵ MD 1" ASME class 150 ʵ˛˚ʵʵ ME 1" ASME class 300 ʵ˛˛ʵʵ ND 1-1/2" ASME class 150 ʵʵ˛˚ʵ NE 1-1/2" ASME class 300 ʵʵ˛˛ʵ PD 2" ASME class 150 ʵʵʵ˛˚ PE 2" ASME class 300 ʵʵʵ˛˛ (Fixed code) 0 Always 0 ○ Outer Cylinder Material * H SS316/316L dual certified ○ A SS316/316L dual certified PED-certified, Max. 6.3 MPa at 20°C Heating Jacket 0 Without ○ Explosionproof Approvals 0 Without ○ R IECEx explosionproof (Ex) Sanitary Approvals 0 Without ○ Type 0 Compact type ○ Calibration 0 Standard 3-point flow calibration ○ 1 5-point fow calibration A 3-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 50 B 5-point flow calibration + density calibration (water: temperature, 3-point) for Sizes 15 to 50 D 5-point flow calibration + UKAS-certified calibration (ISO/IEC 17025) Degreasing 0 Without ○ Special specifications 00 Without 00/Z Special Note: Special requirements not included in the above coding system should be designated by adding "/Z" at the end of the code. Consult us for the availability of such requirements before ordering. * Outer Cylinder Material: Code "H" is recommended for services in the food industry and waste water treatment, which do not require pressure resistance. Code "A" complies with the EU pressure equipment directive (PED). This is recommended for services in the oil and chemical industries and high-pressure processes which require pressure resista nce and higher safety. [Converter code] See "Converter Code" on page 14. STANDARD ACCESSORIES
- Data sheet for setting : 1 set
- Instruction manual : 1 set OPTIONS
- Waterproof cable gland for G1/2 cable connection (code: WG)
- Number of cable entries for external connection: 3 (code: 3G)
- U bolt for 2" pipe installation (code: PM) Head Office : Shiba Toho Building, 1 – 7 – 24 Shibakoen, Minato-ku, Tokyo 105 – 8558 Tel : +81-3 – 3431 – 1625 (KEY) ; Fax : +81-3 – 3433 – 4922 * Specification is subject to change without notice. 5('& MASSMAX 7400R Series Coriolis Mass Flowmeter with Single Straight Measuring Tube TOKYO KEISO CO., LTD. 17