EGC100W is the high-performance separate type con- verter for electromagnetic fl owmeters with the compact housing. Improved self-diagnostic functions include empty pipe detection and conductivity monitoring. The easy-to-use converter in the fi eld, EGC100W is used in combi- nation with the MAGMAX series primary head.

FEATURES

❏ Standardized high-performance functions such as pulse output, bi-directional measurement, double ranges and status outputs including fl ow rate alarms. ❏ High accuracy of ±0.5% of reading. ❏ High speed data processing for quick response. Suitable for batch process control and pulsating fl ow. ❏ The extendable excitation system allows applications to much fl uid noise such as slurry. ❏ The LCD with backlight provides 1 to 3 lines of versatile indica- tion. ❏ Equipped with a quick setup function to readily respond to changed fl ow range, pulse rate, etc. The push buttons allow you to alter the settings without remov- ing the cover of conversion section. ❏ 10kHz high-speed pulse output. Capable of responding to short batch processes. STANDARD SPECIFICATION General Specifi cation

  • Primary head for : MAGMAX Series Primary head combination EGS1000, EGS2000, EGS4000, EGS5000, EGS6000 or others
  • Excitation : Square wave
  • Measuring range : Flow velocity Min. 0 to 0.3m/s Max. 0 to 12m/s
  • Protection class : IP66/67 (IEC 60529)
  • Material Housing : Aluminum alloy Converter cover : Aluminum alloy Indicator water : Polyester protection sheet
  • Painting : Siloxane coating
  • Color : Grey (Housing) Jade green (Cover)
  • Installation : Wall mount, Optionally 2 inch pipe mount (*1) Anti-corrosive painting MAGMAX EGC100W Converter for Electromagnetic Flowmeter
  • Cable entry : 4 × G1/2 female thread 4 × 1/2 NPT female thread 4 × M20 with watertight glands (Option : Watertight glands for G1/2)
  • Supply voltage : 100 to 230V AC (85 to 253V AC) 24V DC (11 to 31V) General purpose (Non explosionproof) 24V DC (18 to 31V) ATEX explosionproof Note: Figures in ( ) show allowable voltage range.
  • Supply frequency : 48 to 63Hz (AC)
  • Power consumption : AC; approx. 8VA DC; approx. 4W
  • Ambient temp. : –40 to +65°C (For operation) –40 to +70°C (For storage) Note: Refer to "Explosionproof Specifi ca- tion" for ATEX explosionpoof.
  • Grounding : Grounding resistance must be less than 100Ω. TG-F2224-E00 1st edition Feb 2022 K

Converter for Electromagnetic Flowmeter EGC100W 2 TOKYO KEISO CO., LTD. TG-F2224-E00

  • Cable Exclusive cable for : DS cable electrode signal 2c × 0.5mm with double shield, PVC sheath, outer diameter ; approx. 10mm Excitation current : 2c × 0.75 to 2.5mm with shield cable outer diameter ≤ 12mm Power supply and : 2 to 4c × 0.5 to 2.5mm 2 ( output signal cables outer diameter ≤ 12mm (*2) Cable length is defi ned and core size is subject to the termi- nal structure. Refer to "Excitation current cable" for details on page 4. (*3) Core size is subject to the terminal structure. Refer to "Applicable core size" for details on page 6. Indication and Output Specifi cation
  • Indicator : Dot matrix LCD (With backlight) 128 × 64 pixels (59 × 31mm) Indication function : Changeover (2 screens) One to three lines are displayed at one screen. Contents of indication ; Flow rate, velocity, total fl ow, conductivity (In case of primary head type EGS5000, it is only nominal size 25 to 100 mm), and coil temperature
  • Current output : 4 to 20mA DC (Max. 22mA at burn out error mode) Internal power supply : Less than 750ohms (Load resistance) External power supply : Less than 32V DC (External voltage)
  • Pulse output Open collector output Rating : Less than 32V DC, 20mA (≤10kHz) Less than 100mA (≤100Hz) Residual voltage: Less than 1.5 VDC at 10 mA Leak current: Less than 0.5 mA at 24 VDC Pulse rate 2 to 36,000,000 pulse/h (0.00056Hz to 10kHz) Pulse width One of the following selectable 1) Automatic : Pulse width by which duty factor to be 50% at full scale 2) Duty factor 1:1 fi xed 3) Free setting ; 0.05 to 2000ms
  • Status output Open collector output Rating : Less than 32V DC, 100mA Max. Residual voltage: Less than 1.5 VDC at 10 mA Leak current: Less than 0.5 mA at 24 VDC Contents of output One of the following selectable: 1) No status output (Standard factory setting) 2) Identifi cation of fl ow direction 3) Over range 4) Error 5) Flow alarm 6) Identifi cation of range (For double range measurement) 7) Empty pipe detection (In case of primary head type EGS5000, it is only nominal size 25 to 100 mm)
  • Description of input and output terminal Terminal A (A, A+ / A–) C (C, C–) D (D, D–) Standard setup Current output Status output Pulse output Switchover by reprogramming Status output
  • Low fl ow cutoff Current output, Pulse output, Indicator (Separate setting is possible.) Setting value : 0.0 to 20.0% FS Setting value (Standard) : Current output, Pulse output ; ON 1%, OFF 2% FS Indicator ; Without low fl ow cutoff
  • Damping time constant Current output, Pulse output, Indicator (Separate setting is possible.) Setting value : 0.0 to 100.0s Setting value (Standard) : Current output, Indicator ; 4s Pulse output ; Damping time constant 0
  • Isolation of input and output Each circuit of power supply, electrode input, terminal A, terminal C, and terminal D are isolated. Standard Functions
  • Customer’s free measuring unit setting function Volume (or mass) and time unit in 7 characters can be cre- ated.
  • Automatic zero adjustment function Zero adjustment is automatically conducted at "ZERO ADJUST MODE" (Subject to zero fl ow)
  • Bi-directional fl ow measurement function A fl ow-direction distinction signal is outputted in state output and current.
  • Double range measurement function Possible range setting range ratio 1 : 20 to 1 : 1.25 (Setting range of low range : 5 to 80% of high range) Range selection ; Automatic
  • Excitation current frequency switching function Standard mode : 1/6 of supply frequency (Standard) Special frequency mode : 1/50 to 1/2 times of supply frequency
  • Self-diagnosis function The following conditions are indicated by error message; Functional diagnosis : Coil disconnection, CPU, Memory, Software, Output module, and Output connection Status diagnosis : Empty pipe detection, Over range, Counter over fl ow, and Power fail detection
  • Memory save function for power fail Operation parameters and totalization fi gures are stored for more than 10 years by EEPROM (Non volatile memo- ry).
  • Testing function Simulating output function for current, pulse output and status output are integrated. Current output test : Arbitrary output (0.0 to 22.0 mA) Pulse output test : Arbitrary output (1Hz to 10kHz) Status output test : On / Off
  • Push button setting function The push buttons allow you to alter the settings without removing the cover of conversion section.
  • HART communication Please confi rm the specifi cation to us. (*4) It can be changed for every application, such as slurry and a pulsating fl ow.

Converter for Electromagnetic Flowmeter EGC100W TOKYO KEISO CO., LTD. 3TG-F2224-E00 Accuracy

  • Indication and Pulse output 1) Used in combination with following primary heads EGS2000, EGS4000, EGS5000 (Nominal size 10 to 250 mm), EGS6000 For fl ow velocity ≥ 0.5 m/s: ±0.5% of reading For fl ow velocity < 0.5 m/s: ±0.3% of reading + Velocity error of ±0.001 m/s 2) Used in combination with following primary heads EGS1000, EGS5000 (Nominal size 2.5 to 6 mm) For fl ow velocity ≥ 1 m/s: ±0.5% of reading For fl ow velocity < 1 m/s: ±0.4% of reading + Velocity error of ±0.001 m/s Error ±% of reading Velocity (m/s) 12 1 20 0.0 0.5 1.0 1.5 2.0 2.5 3.0
  • Current output : Additional error of ±0.01mA be added to the accuracy of indication or pulse output. (*5) Basis condition Fluid : Water Fluid temperature : 10 to 30ºC Conductivity : 150 μS/cm or more Supply voltage : Rated voltage ±2% Ambient temperature : 18 to 28ºC Upstream / Downstream pipe length : 10D / 2D (D: Diameter) Warm-up time : About 10 minutes Measuring time : 100s Explosionproof Specifi cation
  • ATEX explosionproof : Under examination for certifi cation CABLE LENGTH BETWEEN PRIMARY HEAD AND CONVERTER [Electrode signal cable]
  • The maximum length of electrode signal cable Primary head EGS1000 EGS2000 EGS4000 EGS5000 EGS6000 Nominal size (mm) DS Max. cable length Graph 10 to 150 25 to 150 200 to 1200 10 to 150 200 to 1200 2.5 to 100 150 to 250 2.5 to 150 10 to 600m 10 to 600m 10 to 600m 10 to 600m 10 to 600m 10 to 600m 10 to 600m 10 to 600m
  • Fluid conductivity characteristics graph Maximum cable length (m) 105 20 100 Fluid conductivity (μs/cm) EGS2000 EGS1000 / EGS4000 (Size 10 to 150mm) / EGS5000 (Size 2.5 to 100mm) / EGS6000 EGS4000 (Size 200 to 1200mm) / EGS5000 (Size 150 to 250mm) 1000 10000 100 1000 A2 A1 [Excitation current cable] Cable length 150 to 150m 150 to 300m 300 to 600m Nominal cross-section 2 × 0.75 to 2.5mm 2 × 1.5 to 2.5mm2 2 × 2.5mm2

Converter for Electromagnetic Flowmeter EGC100W 4 TOKYO KEISO CO., LTD. TG-F2224-E00 ELECTRICAL CONNECTION BETWEEN CONVERTER AND PRIMARY HEAD EGC100W (Wall installation type) Converter EGC100W Colors in ( ) show sheath color of cores. (R): Red, (W): White ≤100Ω Primary head EGS1000 EGS2000 EGS4000 EGS5000 EGS6000 Ground clamp 123SS78 7891234 A C (R)(W) (W)(R) Terminal No. S Electrode signal input Not used Exciting current output Not used Shield

Description

  • Cable A: DS cable for electrode signal (Exclusive cable) C: Excitation current cable 2c × 0.75 to 2.5mm with shield (Supplied by customer)
  • Terminal : Spring clamp terminal * Connect to the ground using the grounding wire in cross-section area from grounding terminal. (Supplied by customer)

Converter for Electromagnetic Flowmeter EGC100W TOKYO KEISO CO., LTD. 5TG-F2224-E00

  • Terminal type : Spring clamp terminal
  • Applicable core size : 0.5 to 2.5mm ELECTRICAL CONNECTION L N PE Pw C C– D D– S A+ A A– Sp Pp la lp Terminal L (L+) N (L–)– PE (FE) Mark lp la Sp Pp Pw DescriptionPolarity (+) (–) Current output when power is supplied externally. Current output when power is supplied internally. Status output by open collector Pulse output by open collector AC or DC power supply The ( ) show DC power. Grounding for power supply. The (FE) shows DC power. Grounding for shielded wire DIMENSIONS EGC100W Mass: Approx. 1.9kg for general purpose Approx. 2.4kg for ATEX explosionproof type 161 230 4040 40 (23) 112 185 170 R4.5 150 190 140ESC Grounding terminal (M5) for FG For wall mounting ( 4-П9) For 2B pipe fixing ( 4-П9)

Converter for Electromagnetic Flowmeter EGC100W

6 TG-F2224-E00

MODEL AND SPECIFICATION CODE Model : EGC100W (Blank) *1 Add code "/Z" to a series of above mentioned codes with explanation for the other requirements not mentioned above code table. Do not hesitate to consult TOKYO KEISO Co., Ltd. before ordering for such requirements. Converter Spec. code V Converter code (Fixed code) Type Power supply Use purpose N31 VN31 N N A StandardDescription Type:EGC100 always 4 Separate type 24V DC (11 to 31V), General type (Non-explosionproof) 100 to 230V AC (85 to 253V) General type (Non-explosionproof) 1/2 NPT female thread G1/2 female thread M20 with watertight glands always 600 Standard always 2 Standard (Current output + Pulse output + Status output) always 00000 None Involved *1 Cable entry (Fixed code) Housing (Fixed code) Output type (Fixed code) Special feature STANDARD ACCESSORIES

  • Parameter sheet : 1
  • Instruction manual : 1 OPTION
  • G1/2 watertight glands for cable entry : [Symbol : WG]
  • Metal fi xtures for 2 inch pipe mount [Symbol : PM] ORDERING INSTRUCTIONS Specify the following when ordering : 1. Model and specifi cation codes Example : Model : EGC100W PSpecifi cation codes : VN314NA0560012100000 2. Full scale fl ow range and pulse rate. However, Unnecessary if [Symbol : NS] is specifi ed. 3. Optional requirements will be added using above mentioned symbols if required. 4. Specify the length of DS cable with maximum 600m in 10m increments. Head Office : Shiba Toho Building, 1 – 7 – 24 Shibakoen, Minato-ku, Tokyo 105 – 8558 Tel : +81-3 – 3431 – 1625 (KEY) ; Fax : +81-3 – 3433 – 4922 * Specification is subject to change without notice.