ATS TOKYOKEISO | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
Multi-points and averaging temperature sensor ATS GENERAL ATS is an averaging temperature sensor installed from the top of liq- uid bulk storage tank towards the bottom vertically. ATS consists of multiple numbers of temperature detectors having same resistance characteristics located in fixed in tervals along sensor probe. Con- nected to the TOKYO KEISO's digital tank data transmitters, the ATS temperature sensors determine the average temperature of the sub- merged temperature elements and indicates individual temperature including temperature profi le and gas phase temperature. STANDARD SPECIFICATION Element standard : Pt (JIS C1604-1997) On request :JPt, Cu Element class : Standard ; Class B Fine ; Class A Rating current : 2mA Measuring range : 0 to 100°C No. of elements : Max. 16 Measuring length : Max.30000mm Element interval : Standard sensor intervals : 1m, 2m, 3m Consult TOKYO KEISO for other intervals including uneven distribution. Operating pressure : Atmospheric pressure Connection : Flange Flange size : 40mm, 50mm, 80mm, 100mm or others Rating : JIS10K RF , ANSI Class 150, JPI Class 150 or others Enclosure : Flameproof construction Exd ll B T4 (TllS) Exd ll B T6 (LCIE) Exd ll B T4 (KOSHA) Intrinsic safety Ex ia II B T4 (Corresponding to the combination with RTG 3900 only) Element number: 6 elements (Max.) Cable entry : G3/4 or others (with adapters) Cable termination : M3.5 screw terminal Painting color : Terminal box: Silver (Standard) Stainless steel part: Not painted Material : 1ssalclairetaM ATS-□□□1 2ssalclairetaM ATS-□□□2 ebut.xelF SUS316L L 613SUS egnalF4 03SUS6 13SUS xoblanimreT ADC12 thgiewrohcnA4 03SUS6 13SUS Mass : Measuring length (m) Mass (kg) MODEL CODE Model code ATS– –– Element interval Special "01"(1 element) to "16"(16 elements) Material class 1 Material class 2 Special Water tight Flameproof construction (TIIS) Flameproof construction (LCIE) Flameproof construction (KOSHA) Intrinsic safety JPt (JIS) Pt (JIS) Class A (Fine) Class B (Standard) 40mm (11/2") 50m (2") 80m (3") 100m (4") Others JIS10K RF ANSI Class 150 JPI Class 150 Others Not provided Provided Not provided Provided J P A B W S No. of elements Element class Standard element Enclosure Process flange size Process flange rating Flameproof cable gland Anchor weight Material class
Description
ˎ 1: Consult TOKYO KEISO for other kinds of materials. ˎ 2: with adapters ˎ 3: It is required to use specifi c Flameproof cable gland. ˎ 4: Specify cable Outside diameter. 5(-%& 0DU .BZ UIFEJUJPO TUFEJUJPO
ATS Multi-points and averaging temperature sensor TG-LD271-4E2 DIMENSION ELEMENT ARRANGEMENT (mm) H10 H11 H12 H13 H14 H15 H16 1m Interval ATS–1□□□ 2m Interval ATS–2□□□ 3m Interval ATS–3□□□ 450 1500 2500 3500 4500 5500 6500 7500 8500 9500 10500 11500 12500 13500 14500 15500 450 2500 4500 6500 8500 10500 12500 14500 16500 18500 20500 22500 24500 26500 28500 450 3500 6500 9500 12500 15500 18500 21500 24500 27500 NUMBER OF ELEMENTS Number of elements are determined from the maximum liquid level and element intervals as shown in the following table. 0 to 1999 2000 to 2999 3000 to 3999 4000 to 4999 5000 to 5999 6000 to 6999 7000 to 7999 8000 to 8999 9000 to 9999 10000 to 10999 11000 to 11999 12000 to 12999 13000 to 13999 14000 to 14999 15000 to 15999 16000 to 16999 0 to 2999 3000 to 4999 5000 to 6999 7000 to 8999 9000 to 10999 11000 to 12999 13000 to 14999 15000 to 16999 17000 to 18999 19000 to 20999 21000 to 22999 23000 to 24999 25000 to 26999 27000 to 28999 29000 to 30999 0 to 3999 4000 to 6999 7000 to 9999 10000 to 12999 13000 to 15999 16000 to 18999 19000 to 21999 22000 to 24999 25000 to 27999 28000 to 30999 1m Interval ATS–1 □□□ Max. Liquid level 2m Interval ATS–2□□□ 3m Interval ATS–3□□□ No. of element Note : Consult TOKYO KEISO if gas phase temperature measurement is required. ASSOCIATED TRANSMITTERS AND RECEIVERS ATS Averaging temperature sensors are connectable to the following TOKYO KEISO's instruments for further transmission and indication. (1) FW-9000, FW-9000N, FW9000NN super intelligent tank gauge. (2) DM4N-2, -3 Intelligent tank data transmitter. (3) RTG3900 Microwave level meters.
ORDERING INFORMATION
Please specify the following for order / inquiry : 1) Model code 2) Total length from tank nozzle to tank bottom. (A or L length in sketch) 3) External diameter of connection cable if the cable glands are required to supply by TOKYO KEISO. 4) Other special requirements, if any. Head Office : Shiba Toho Building, 1 – 7 – 24 Shibakoen, Minato-ku, Tokyo 105 – 8558 Tel : +81-3 – 3431 – 1625 (KEY) ; Fax : +81-3 – 3433 – 4922 * Specification is subject to change without notice.