RC4136, RM4136, RV4136 QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS SLOS072A – MARCH 1978 – REVISED JANUARY 2002 /C0068 Continuous Short-Circuit Protection /C0068 Wide Common-Mode and Differential Voltage Ranges /C0068 No Frequency Compensation Required /C0068 Low Power Consumption /C0068 No Latch-Up /C0068 Unity-Gain Bandwidth...3 M H z T y p /C0068 Gain and Phase Match Between Amplifiers /C0068 Designed To Be Interchangeable With Raytheon RC4136, RM4136, and RV4136 /C0068 Low Noise ...8 n V√Hz Typ at 1 kHz

description

The RC4136, RM4136, and RV4136 are quad general-purpose operational amplifiers, with each amplifier electrically similar to the µA741, except that offset null capability is not provided. The high common-mode input voltage range and the absence of latch-up make these amplifiers ideal for voltage-follower applications. The devices are short-circuit protected and the internal frequency compensation ensures stability without external components. The RC4136 is characterized for operation from 0°C to 70°C, the RM4136 is characterized for operation over the full military temperature range of –55°C to 125 °C, and the RV4136 is characterized for operation from –40°C to 85°C. symbol (each amplifier) IN+ IN– OUT AVAILABLE OPTIONS VIOMAX PACKAGE TA VIOMAX AT 25°C SMALL OUTLINE CHIP CARRIER CERAMIC DIP PLASTIC DIP FLATAT 25 C (D) (FK) (J) (N) (W) 0°C to 70°C 6 mV RC4136D — — RC4136N — –40°C to 85°C 6 mV RV4136D — — RV4136N — –55°C to 125°C 4 mV — RM4136FK RM4136J — RM4136W The D packages are available taped and reeled. Add the suffix R to the device type (e.g., RC4136DR). The RM4136 and RV4136 are obsolete and are no longer supplied. 1IN– 1IN+ 1OUT 2OUT 2IN+ 2IN– V CC– 4IN– 4IN+ 4OUT V CC+ 3OUT 3IN+ 3IN– RM4136 ...J O R W PACKAGE ALL OTHERS ...D O R N PACKAGE (TOP VIEW) 3 2 1 20 19 91 0 1 1 1 2 1 3 4OUT NC V CC+ NC 3OUT 1OUT NC 2OUT NC 2IN+ RM4136 . . . FK PACKAGE (TOP VIEW) NC 3IN– 3IN+ 2IN– NC 1IN+ 1IN– 4IN– 4IN+ VCC– NC – No internal connection

RC4136, RM4136, RV4136 QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS SLOS072A – MARCH 1978 – REVISED JANUARY 2002 schematic (each amplifier) OUT IN+ IN– VCC – VCC+ absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC+ and VCC –. 2. Differential voltages are at IN+ with respect to IN–. 3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less. 4. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded. 5. The package thermal impedance is calculated in accordance with JESD 51-7. DISSIPATION RATING TABLE PACKAGE TA ≤ 25°C POWER RATING DERATING FACTOR DERATE ABOVE T A TA = 70°C POWER RATING TA = 85°C POWER RATING TA = 125°C POWER RATING FK 800 mW 11.0 mW/°C 77°C 800 mW 715 mW 275 mW J 800 mW 11.0 mW/ °C7 7 °C 800 mW 715 mW 275 mW W 800 mW 8.0 mW/°C 50°C 640 mW 520 mW 200 mW The RM4136 and RV4136 are obsolete and are no longer supplied.

RC4136, RM4136, RV4136 QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS SLOS072A – MARCH 1978 – REVISED JANUARY 2002 recommended operating conditions MIN MAX UNIT VCC+ Supply voltage 5 15 V VCC – Supply voltage –5 –15 V electrical characteristics at specified free-air temperature, VCC+ = 15 V, VCC – = –15 V PARAMETER TEST CONDITIONS † RC4136 RM4136 RV4136 UNITPARAMETER TEST CONDITIONS † MIN TYP MAX MIN TYP MAX MIN TYP MAX UNIT Input offset 25°C 0.5 6 0.5 4 0.5 6 VIL Input offset voltage VO = 0 Full range 7.5 6 7.5 mV Input offset 25°C 5 200 5 150 5 200 IIO Input offset current VO = 0 Full range 300 500 500 nA 25°C 140 500 140 400 140 500 IIB Input bias current VO = 0 Full range 800 1500 1500 nA Vi Input voltage range 25°C ±12 ±14 ±12 ±14 ±12 ±14 V Maximum peak R L = 10 kΩ 25°C ±12 ±14 ±12 ±14 ±12 ±14 VOM M aximum pea k output voltage R L = 2 kΩ 25°C ±10 ±13 ±10 ±13 ±10 ±13 VVOM out ut voltage swing R L ≥ 2 kΩ Full range ±10 ±10 ±10 V Large-signal VO = ±10 V 25°C 20 300 50 350 20 300 AVD gg differential voltage amplification VO = ±10 V, R L ≥ 2 kΩ Full range 15 25 15 V/mV Unity-gain bandwidth 25°C 3 3.5 3 MHz ri Input resistance 25°C 0.3* 5 0.3* 5 0.3* 5 M Ω CMRR Common-mode rejection ratio VO = 0, R S = 50 Ω 25°C 70 90 70 90 70 90 dB Supply-voltage VCC = ±9Vt o±15 VkSVS yg sensitivity VCC = ±9 V to±15 V, VO =0 25°C 30 150 30 150 30 150 µV/VSVS (∆VIO/∆VCC ) VO = 0 µ Vn Equivalent input noise voltage (closed loop) AVD = 100, BW = 1 Hz, f = 1 kHz, R S = 100 Ω 25°C 8 8 8 nV√Hz Supply current 25°C 5 11.3 5 11.3 5 11.3 ICC Supply current (all four amplifiers)VO = 0, No load MIN TA 6 13.7 6 13.3 6 13.7 mA(all four am lifiers) MAX T A 4.5 10 4.5 10 4.5 10 Total power 25°C 150 340 150 340 150 340 PD Total ower dissipation VO = 0, No load MIN TA 180 400 180 400 180 400 mW (all four amplifiers) MAX T A 135 300 135 300 135 300 Crosstalk AVD = 100, attenuation VD , f = 10 kHz, 25°C 105 105 105 dB (VO1 /VO2 ) R S = 1 kΩ *This parameter is not production tested. † All characteristics are measured under open-loop conditions with zero common-mode input voltage, unless otherwise specified. Full range is 0°C to 70°C for RC4136, –55°C to 125°C for RM4136, and –40°C to 85°C for RV4136. Minimum TA is 0°C for RC4136, –55°C for RM4136, and –40°C for RV4136. Maximum TA is 70°C for RC4136, 125°C for RM4136, and 85°C for RV4136. The RM4136 and RV4136 are obsolete and are no longer supplied.

RC4136, RM4136, RV4136 QUAD GENERAL-PURPOSE OPERATIONAL AMPLIFIERS SLOS072A – MARCH 1978 – REVISED JANUARY 2002 operating characteristics, VCC+ = 15 V, VCC – = –15 V, TA = 25°C PARAMETER TEST CONDITIONS TYP UNIT tr Rise time VI = 20 mV, C L = 100 pF,R L = 2 kΩ 0.13 µs Overshoot factor VI = 20 mV, C L = 100 pF,R L = 2 kΩ 5 % SR Slew rate at unity gain VI=1 0V C L = 100pF R L =2k Ω 17 V/µsSR Slew rate at unity gain VI = 10 V, C L = 100 pF, R L = 2 kΩ 1.7 V/µs The RM4136 and RV4136 are obsolete and are no longer supplied.