EE872 EPLUSE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 10

Technical content

Modular Probe for CO 2, Humidity, Temperature and Ambient Pressure EE872

v1.8 / Modification rights reserved | 2 EE872 Modular Probe for CO2, Humidity, Temperature and Ambient Pressure The EE872 probe, with a measurement range up to 5 % CO 2 (50 000 ppm), is suitable for use in harsh and demanding environment in agriculture, life stock barns, hatchers, incubators, green houses or outdoors. Outstanding Accuracy A multi-point CO 2 and temperature adjustment procedure leads to excellent CO 2 measurement accuracy over the entire T working range of -40…+60 °C (-40…+140 °F), which is ideal for agriculture or outdoor use. Long-Term Stability EE872 incorporates the E+E dual wavelength NDIR CO 2 sensor, which automatically compensates for ageing effects and is highly insensitive to pollution. The RH sensing element with E+E proprietary coating is suitable even for aggressive and corrosive environment. Pressure and Temperature Compensation The active compensation with on-board sensors leads to best CO 2 measurement accuracy independently of weather conditions, altitude or temperature. 4 in 1 Beside CO2, the EE872 measures also relative humidity (RH), temperature (T) and ambient pressure (p). Additionally, the device calculates the dew point temperature (Td). Reliable in Harsh and Condensing Environment The heated version of EE872 is suitable for high humidity and condensing environment. The IP65 enclosure and the replaceable filter offer excellent protection in polluted environment. With a special filter, the EE872 is also appropriate for applications with periodical H 2O2 sterilization. Analogue Output or RS485 Interface The CO2 measured data is available simultaneously on the analogue voltage and current outputs. Depending on the model, EE872 with RS485 interface with Modbus RTU or BACnet MS/TP protocol also provides the values for RH, T, p and Td. Configurable and Adjustable The free PCS10 Product Configuration Software together with an optional adapter cable facilitates the configuration and adjustment of the EE872. Stainless steel probe with PTFE filter Polycarbonate probe with H 2O2 filter

v1.8 / Modification rights reserved | 3

Features

▪ PTFE ▪ Catalytic for H 2O2 sterilization ▪ Replaceable Interchangeable Sensing Module ▪ E+E dual wavelength NDIR, auto-calibration ▪ T and p compensation with on-board sensors ▪ Heated versions for preventing condensation ▪ RH sensing element protected by E+E sensor coating ▪ Configurable and adjustable Supply and Output Module ▪ CO2 voltage and current output ▪ Modbus RTU or BACnet MS/TP (CO 2, T, RH, p, Td) ▪ IP65 protection rating ▪ Stainless steel or plastic enclosure ▪ M12 stainless steel connector ▪ User configurable Test Report According to DIN EN 10204-2.2 PLUG-AND-PLAY SIGMA

v1.8 / Modification rights reserved | 4 The E+E proprietary sensor coating is a protective layer applied to the active surface of the sensing element. The coating substantially extends sensor lifetime and ensures optimal measurement performance in corrosive environment (salts, off- shore applications). Additionally, it improves the sensors’ long term stability in dusty, dirty or oily applications by preventing stray impedance caused by deposits on the active sensor surface. Protective Sensor Coating 136 (5.35) M12x1 plug 65 (2.56) Ø25 (0.98) 61 (2.4) Filter Values in mm (inch) Dimensions Sigma 05 with EE872 The EE872 is compatible with the Sigma 05 host device of the E+E Modular Sensor Platform. Together they become a versatile, plug-and-play CO 2/RH/T/p modular sensor with analogue outputs and optional display. Besides EE872, Sigma 05 accommodates also other E+E intelligent sensing probes. See www.epluse.com/sigma05 for further details. E+E Modular Sensor Platform If the probe remains on the measuring site during cleaning operations, the optional calibration adapter can be used for protection. For this purpose, both nipples are closed with the rubber caps supplied. In case the probe is removed from the site, it is recommended to apply the protection caps for the M12 cable socket and the EE872 M12 plug. Device Protection During Site Cleaning

v1.8 / Modification rights reserved | 5 Technical Data Measurands CO2 Measurement principle Dual wavelength non-dispersive infrared technology (NDIR) Measuring range 0...2 000 ppm / 5 000 ppm / 10 000 ppm / 3 % / 5 % Accuracy @ 25 °C (77 °F) and 1 013 mbar (14.7 psi) 0...2 000 ppm 0...5 000 ppm 0...10 000 ppm 0...3 % 0...5 % < ±(50 ppm + 2 % mv) < ±(50 ppm + 3 % mv) < ±(1.5 % of full scale + 2 % mv) < ±(1.5 % of full scale + 2 % mv) mv = measured value Temperature dependency <10 000 ppm >10 000 ppm -0.3 % of mv/°C -0.167 % mv/°F mv = measured value Residual pressure dependency 1) related to 1 013 mbar (14.7 psi) 0.014 % of mv/mbar 0.965 % of mv/psi mv = measured value Long-term stability , typ. @ 0 ppm CO 2 20 ppm/year Response time t 63, typ.2) 90 s Measuring interval 15 s (user adjustable from 15 s to 1 h) 1) Pressure dependency of a sensor without pressure correction: 0.14 % of mv/mbar. 2) With data averaging algorithm for smooth output signal. Faster response time available on request. Relative Humidity (RH) Measuring range Heating enabled Heating disabled 0...100 %RH 0…95 %RH (non-condensing) Accuracy1) @ 25 °C (77 °F) 20...80 %RH 0...95 %RH ±3 %RH ±5 %RH 1) With 24 V DC supply, air flow min. 0.3 m/s, probe horizontal or with sensing head downwards, excl. hysteresis Pressure (p) Accuracy, typ. @ 25 °C (77 °F) ±2 mbar (±0.03 psi) Temperature dependency ±0.016 mbar/K (0.00013 psi/°F) Temperature (T) Accuracy, typ.1) ±0.5 °C (±0.9 °F) 1) With 24 V DC supply, air flow min. 0.3 m/s, probe horizontal or with sensing head downwards, excl. hysteresis. Calculated parameters Unit Dew point temperature Td °C

v1.8 / Modification rights reserved | 6 Technical Data Outputs Digital Digital interface RS485 (EE872 = 1/10 unit load) Protocol Factory settings 1) Supported Baud rates Measured data types Modbus RTU Baud rate acc. to order code, parity even, 1 stop bit, Modbus address 237 9 600, 19 200 and 38 400 FLOAT32 and INT16 Protocol Factory settings 2) Supported Baud rates BACnet MS/TP Baud rate acc. to order code, BACnet address 6 9 600, 19 200, 38 400, 57 600, 76 800 and 115 200 1) More details about communication setting and the Modbus map: See User Manual and Modbus Application Note at www.epluse.com/ee872 . 2) The BACnet MS/TP Product Implementation Conformance Statement (PICS) is available at www.epluse.com/ee872 . Analogue CO2 0 - 5 V / 0 - 10 V 0 < IL < 1 mA IL = load current 0 - 20 mA / 4 - 20 mA (3-wire) RL ≤ 500 Ω RL = load resistance Power supply class III USA & Canada: Class 2 supply necessary, max. voltage 30 V DC Current output RS485 interface and voltage output 15 - 35 V DC 12 - 30 V DC Current consumption @ 24 V DC/AC and 15 s measurement interval 20 mA current output RS485 interface and voltage output 37 mA 17 mA Peak current , max. 200 mA Electrical connection M12x1 5 poles, stainless steel 1.4404 Filter PTFE (Polytetrafluoroethylene), UL94 V-0 approved 0...95 %RH, non-condensing Enclosure material Stainless steel 1.4404 PET (Polyethyleneterephthalate), UL94HB approved Protection rating probe body IP65 Electromagnetic compatibility EN 61326-1 EN 61326-2-3 Industrial environment FCC Part15 Class A ICES-003 Class A Conformity General

v1.8 / Modification rights reserved | 7 Ordering Guide Feature Description Code Hardware Configuration EE872- Model CO2 (default: heated) M10 CO2 + T + RH + p (default: not heated) M13 CO2 measuring range 0...2 000 ppm HV1 0...5 000 ppm HV2 0...10 000 ppm HV3 0...3 % (30 000 ppm) HV5 0...5 % (50 000 ppm) HV6 Probe material PET (Polyethyleneterephtalate) No code Stainless steel PM2 Filter PTFE (Polytetrafluoroethylene ) No code Catalytic for H 2O2 sterilzation F12 Software Setup Output Output 1: 0 - 10 V Output 2: 4 - 20 mA GA7 Output 1: 0 - 5 V Output 2: 0 - 20 mA GA11 Modbus RTU P1 P1 BACnet MS/TP P3 P3 Baud rate 9 600 No code 19 200 BD6 38 400 BD7 57 600 (for BACnet only) BD8 76 800 (for BACnet only) BD9 115 200 (for BACnet only) BD10 Probe Sensing Module (Spare Part) Feature Description Code Hardware Configuration EE872S- Model CO2 (default: heated) M10 CO2 + T + RH + p (default: not heated) M13 CO2 range1) 0...2 000 ppm HV1 0...5 000 ppm HV2 0...10 000 ppm HV3 0...3 % (30 000 ppm) HV5 0...5 % (50 000 ppm) HV6 1) The sensing module’s CO 2 range must match that of the originally ordered EE872 probe.

v1.8 / Modification rights reserved | 8 Order Examples Feature Code Description Model M10 CO2 CO2 range HV1 0...2 000 ppm Probe material No code PET (Polyethyleneterephtalate) Filter No code PTFE (Polytetrafluoroethylene) Output signal GA7 Output 1: 0 - 10 V Output 2: 4 - 20 mA Sensor EE872-M10HV1GA7 Sensing Module EE872S-M10HV1 Sensor EE872-M13HV6PM2F12P1 Feature Code Beschreibung Modell M13 CO2 + T + RH + p CO2 range HV6 0...5 % Probe material PM2 Stainless steel Filter F12 Catalytic for H 2O2 sterilization Protocol P1 Modbus RTU Baud rate No code 9 600 Parity No code Even Stop bit No code 1 Feature Code Beschreibung Model M10 CO2 + T + RH + p CO2 range HV1 0...2 000 ppm

v1.8 / Modification rights reserved | 9 Accessories Description Code Mounting flange stainless steel HA010226 Wall mounting clip Ø25 mm HA010227 Radiation shield HA010510 M12x1 flanged coupling with 50 mm (1.97") stranded wires HA010705 Modbus configuration adapter HA011018 E+E Product Configuration Software (Free download from www.epluse.com/pcs10 ) PCS10 Connection cable M12x1 socket 5 poles / free ends 1.5 m (4.9 ft) 5 m (16.4 ft) 10 m (32.8 ft) HA010819 HA010820 HA010821 Y-style splitter M12 - M12 HA030204 M12x1 connector, 5 poles, for self assembly HA010708 Protection cap / calibration adapter HA010785 Protection cap for M12 socket HA010781 Protection cap for M12 plug HA010782 For further information see datasheet Accessories .

Company Headquarters & Production Site E+E Elektronik Ges.m.b.H. Langwiesen 7

4209 Engerwitzdorf | Austria

info@epluse.com www.epluse.com Subsidiaries E+E Sensor Technology (Shanghai) Co., Ltd. T +86 21 6117 6129 info@epluse.cn E+E Elektronik France SARL T +33 4 74 72 35 82 info.fr@epluse.com E+E Elektronik Deutschland GmbH T +49 6171 69411-0 info.de@epluse.com E+E Elektronik India Private Limited T +91 990 440 5400 info.in@epluse.com E+E Elektronik Italia S.R.L. T +39 02 2707 86 36 info.it@epluse.com E+E Korea Co., Ltd. T +82 31 732 6050 info.kr@epluse.com E+E Elektronik Corporation T +1 847 490 0520 info.us@epluse.com Version v1.8 | 03-2023 Modification rights reserved