Humidity and Temperature Sensor with Interchangeable Probes EE220

v1.7 / Modification rights reserved | 2 EE220 The innovative, modular EE220 humidity (RH) and temperature (T) sensor consists of a basic unit and various pluggable, interchangeable probes. Versatility The basic unit can accommodate one combined EE07 RH and T probe or two separate EE07 probes, one for RH and one for T. The EE07 probes are available in plastic or in stainless steel enclosure and can be plugged onto the basic unit either directly or with M12 extension cables up to 10 m (32.8 ft) long. An optional kit facilitates the mounting of the probes in a duct. The EE220 basic unit is available with polycarbonate or with metal enclosure, suitable for wall mount or for installation on rails (DIN EN 50022). For the pharmaceutical and food industry the basic unit features a rear cable inlet. Outputs and Display The measured values are available on two analogue voltage or current (2-wire 4 - 20 mA) outputs, as well as on the optional display. Configurable and Adjustable 1- or 2-point adjustment for RH and T of the sensor can be easily performed with push buttons on the electronics board of the EE220 basic unit. Alternatively, the EE07 probes can be adjusted individually with the EE-PCA Product Configuration Adapter (see EE07 data sheet). Humidity and Temperature Sensor with Interchangeable Probes EE220 polycarbonate enclosure with EE07 polycarbonate probe EE220 aluminium die-cast enclosure with two EE07 stainless steel probes

v1.7 / Modification rights reserved | 3 M12 Probe connection ▪ Easy probe exchange ▪ Directly on EE220 or with M12 cables up to 10 m

Features

According to DIN EN 10204-3.1 Outputs, Calibration and Adjustment ▪ 2 analogue voltage or current outputs ▪ Adjustment 1- or 2-point adjustment for RH and T, via push buttons on the electronics board ▪ Calibration Easy loop calibration with separate probes for RH and T Enclosure ▪ Polycarbonate or aluminium die-cast ▪ IP65 / NEMA 4(X) protection rating ▪ Easy mounting and cleaning ▪ Versatile connection options Interchangeable probes ▪ Outstanding accuracy and long term stability ▪ Wide temperature working range ▪ Combined and separate probes for RH and T available ▪ Stainless steel or polycarbonate enclosure ▪ Reference probes for functional check

v1.7 / Modification rights reserved | 4 Dimensions Values in mm (inch) Enclosure Polycarbonate Aluminium die-cast 135 (5.3) 50 (2) 90 (3.5) 163 (6.4) 135 (5.3) 50 (2) 90 (3.5) EE220 with one RH + T probe EE220-xNP1x EE220 with two separate probes for RH + T EE220-xNP2x (1.3) (0.7) (1.6) ∅13 (0.51) T probeRH probe ∅12 (0.47)25 (1) (0.7) (2) ∅6 (0.2) EE220 with one remote RH + T probe EE220-xNP1x+ HAxxxx EE220 with two separate remote probes for RH + T EE220-xNP2x + 2x HAxxxx Cable length Ordering code 2 m (6.6 ft) HA010801 5 m (16.4 ft) HA010802 10 m (32.8 ft) HA010803 *) L = Filter length see Datasheet „Accessories“ L*) 83 (3.3) ∅13 (0.51) ∅12 (0.47) T probe RH probe (1) (3.6) ∅6 (0.2)

v1.7 / Modification rights reserved | 5 Dimensions Values in mm (inch) Duct mounting kit HA010209 M12x1 ∅15 (0.59) 200 (7.87) 60 (2.36) 46 (1.81) 5.2 (0.2) (1.18) 2 (0.08) A loop calibration or adjustment in the field, as required by the FDA (Food and Drugs Administration) regulated industries is easily possible for the EE220 with two separate probes. Using extension cables, the EE07 probes can be dropped into calibrators without dismounting the EE220 basic unit. The illustration below shows the EE07 RH probe placed in the Humor 20 high end portable humidity calibrator and the EE07 T probe in a dry block calibrator. Field Loop Calibration Temperature calibrator EE07 RH probe EE07 T probe

v1.7 / Modification rights reserved | 6 Sensing Probes Technical data and ordering guide see EE07 data sheet Reference Probes A functional and accuracy check of the EE220 basic unit can be performed using reference probes instead of the regular EE07 probes. These are certified by individual test reports and available for two pairs of fixed RH and T values: ▪ RH = 10 % and T = 45 °C (113 °F) ▪ RH = 90 % and T = 5 °C (41 °F) Humidity / Temperature Probes Measuring Range EE07 RH / T probe, polycarbonate 0...100 %RH EE07 RH / T probe, stainless steel, for clean rooms, food and pharmaceutical industry 0...100 %RH Temperature Probes Measuring Range EE07 T probe, polycarbonate EE07 T probe, stainless steel, for clean rooms, food and pharmaceutical industry

v1.7 / Modification rights reserved | 7 Technical Data Outputs Power supply class III USA & Canada: Class 2 supply necessary, max. voltage 30 V DC 0 - 1 V 0 - 10 V 4 - 20 mA 10 - 35 V DC or 9 - 29 V AC 15 - 35 V DC or 15 - 29 V AC

10 V + RL x 20 mA < UV < 35 V DC

Current consumption , typ. DC supply @ 24 V DC/AC AC supply 10 mA 20 mArms Electrical connection Screw terminals max. 2.5 mm 2 (AWG 14) Cable glands Cable gland M16x1.5, cable Ø4.5 - 10 mm (0.18 - 0.39") Working and storage conditions without display with display 0…95 %RH, non-condensing 700…1 200 mbar Enclosure Material Protection Rating Polycarbonate IP65 / NEMA 4X Aluminium die-cast (AlSi9Cu3) IP65 / NEMA 4 Electromagnetic compatibility EN 61326-1:2013 EN 61326-2-3:2013 Industrial Environment FCC Part15 ClassA ICES-003 ClassA Conformity General Analogue 0 - 10 V -1 mA < IL < 1 mA 4 - 20 mA (2-wire) RL < 500 Ω RL = load resistance Temperature dependency, max. 0.2 mV/°C, 1 µA/°C

v1.7 / Modification rights reserved | 8 Ordering Guide The EE220 basic unit does not include the sensing probes, which are to be ordered separately. The order shall include three positions: ▪ EE220 basic unit ▪ EE07 probes ▪ Probe cables, optional for EE07 probes Feature Description Code Hardware Configuration EE220- Enclosure material PC (Polycarbonate) No code Aluminium die-cast (AlSi9Cu3) HS3 Output 0 - 1 V A1 0 - 10 V A3 4 - 20 mA A6 Number of probes 1, combined for RH + T NP1 2, seperate probes for RH + T NP2 Electrical connection Cable gland M16x1.5 E1 1 plug for power supply and outputs E4 Rear cable inlet E34 Display Without No code With display D1 SW Config. Output T measurand Temperature [°C] No code Temperature [°F] MB2 Output T scaling low 0 No code Value SBLValue Output T scaling high 50 No code Value SBHValue Type Code Cable for EE07 (optional) 2 m (6.6 ft) HA010801 5 m (16.4 ft) HA010802 10 m (32.8 ft) HA010803 Position 2: Probes See EE07 ordering guide in the corresponding data sheet at www.epluse.com/ee220 . Position 3: Probe cables Position 1: EE220 Basic Unit

v1.7 / Modification rights reserved | 9 Order Example EE220-HS3A3NP1E4 Feature Code Description Enclosure material HS3 Aluminium die-cast (AlSi9Cu3) Output A3 0 - 10 V Number of probes NP1 1, combined for RH + T Electrical connection E4 1 plug for power supply and outputs Display No code Without Output T measurand No code Temperature [°C] Output T scaling low No code 0 °C Output T scaling high No code 50 °C Position 1 - Basic Unit: EE07-M1HS2F9 Feature Code Description Model M1 Humidity and temperature Enclosure material HS2 Stainless steel Filter F9 Stainless steel grid Sensor coating No code Without Additional function No code Without Position 2 - Probe: HA010802 Feature Code Description Cable for EE07 HA010802 5 m (16.4 ft) cable for EE07 Position 3 - Probe cable: Accessories Description Code Display and metal front cover D07M Display and polycarbonate front cover D07P Duct mounting kit HA010209 Extension cable for EE07 2 m (6.6 ft) 5 m (16.4 ft) 10 m (32.8 ft) HA010801 HA010802 HA010803 Bracket for rail installation (polycarbonate enclosure only) HA010203 Power supply adapter V03 Reference probes set (2 probes) HA010403 For further information see datasheet Accessories .

Company Headquarters & Production Site E+E Elektronik Ges.m.b.H. Langwiesen 7

4209 Engerwitzdorf | Austria

info@epluse.com www.epluse.com Subsidiaries E+E Sensor Technology (Shanghai) Co., Ltd. T +86 21 6117 6129 info@epluse.cn E+E Elektronik France SARL T +33 4 74 72 35 82 info.fr@epluse.com E+E Elektronik Deutschland GmbH T +49 6171 69411-0 info.de@epluse.com E+E Elektronik India Private Limited T +91 990 440 5400 info.in@epluse.com E+E Elektronik Italia S.R.L. T +39 02 2707 86 36 info.it@epluse.com E+E Korea Co., Ltd. T +82 31 732 6050 info.kr@epluse.com E+E Elektronik Corporation T +1 847 490 0520 info.us@epluse.com datasheet_EE220 | Version v1.7 | 01-2024 Modification rights reserved