Features
» Mechanical protection » Condensation-resistant E+E sensing element HCT01 » Long-term stability » Protected solder pads » Tested according to automotive standard AEC-Q200 Aluminum enclosure » IP65 protection class » External mounting holes and grounding connection Approved for installation in gas Zone 1 » ATEX: II 2G Ex ia IIB T4 Gb » IECEx: Ex ia IIB T4 Gb Ta = -40 °C to 60 °C » Korea: Ex ia IIB T4 » Japan: Ex ia IIB T4 Gb (Ta = -40 °C bis 60 °C) Inspection certificate according to DIN EN 10204-3.1 Model T1 - wall mount Interchangeable probe with M12 connector (Model T23)
v1.4 / Modification rights reservedEE100Ex 167 Protective Sensor Coating The E+E proprietary sensor coating is a permeable layer applied to the active surface of the RH sensing element. The coating extends substan- tially the life-time and the measurement performance of the E+E sensor in corrosive environment. Additionally, it improves the long term stability in dusty and dirty applications by preventing stray impedances caused by deposits on the active sensor surface. Technical Data Measurands Relative Humidity (RH) Measurement range 0...100 % RH Accuracy1) (incl. hysteresis, non-linearity and repeatability) wall mount model (T1) remote probe models (T3, T23) Temperature (T) Accuracy and wall mount (T1) remote probe (T3, T23) ± ∆ °C ± ∆ °C measurement range Calculated parameters2) dew point temperature [Td] frost point temperature [Tf] 1) Traceable to intern. standards, administrated by NIST, PTB, BEV,... The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement). Accuracy is specified for models T3, T23 with an airflow >0.0m/s, for model T1 with an airflow 0.2 m/s. 2) For the accuracy please use “E+E humidity calculator” or refer to document “Principles of humidity measurement”, available on www.epluse.com Ex - Classifications Europe (ATEX with order code "EX8") Certificate: TPS 19 ATEX 038892 0008 X by TÜV SÜD Product Service GmbH Safety data: Ui = 28 V; Ii = 100 mA; Pi = 700 mW; Ci = 2.2 nF; Li ≈ 0 mH Ex-Designation: II 2G Ex ia IIB T4 Gb International (IECEx with order code "EX8") Certificate: IECEx TPS 18.0014 X by TÜV SÜD Product Service GmbH Safety data: Ui = 28 Vdc; Ii = 100 mA; Pi = 700 mW; Ci = 2.2 nF; Li ≈ 0 mH Ex-Designation: Ex ia IIB T4 Gb Ta = -40 °C to 60 °C Korea (KCs with order code "EX5") Certificate: 20-AV4BO-0440X by KCs Safety data: Ui = 28 Vdc; Ii = 100 mA; Pi = 700 mW (per channel); Ci = 2.2 nF; Li = negligible small Ex-Designation: Ex ia IIB T4 -40°C ≤ Tamb ≤ +60°C: humidity/temperature sensor -40°C ≤ Tamb ≤ +40°C: connection cable Japan (CSA with order code "EX6") Certificate: CSAUK 20JPN060X by CSA Group Testing UK Ltd Safety data: Ui = 28 V DC; Ii = 100 mA; Pi = 700 mW (per channel); Ci = 2.2 nF; Li ≈ 0 Ex-Designation: Ex ia IIB T4 Gb (Ta = -40 °C to 60 °C)
v1.4 / Modification rights reserved EE100Ex 168 Output Analogue outputs 2 x 4...20 mA, 2-wire, user configurable General Supply voltage UV from intrinsically safety barrier 11 V + RL * 0.02 A < Uv < 28 V DC (RL = load resistor) safety data Ui=28 V; Ii=100 mA; Pi=700 mW; Ci = 2.2 nF; Li ≈ 0 mH Electrical connection screw terminals, max. 1.5 mm² Cable glands (brass, nickel plated) M16 x 1.5 for cable diameter 4.5 - 10 mm (0.18“ - 0.39“) M20 x 1.5 for cable diameter 7 - 13 mm (0.28“ - 0.51“) Protection class (enclosure and probe) IP65 Working temperature ranges Material enclosure aluminium (Al Si9 Cu3) probe ABS (model T1) polycarbonate (model T3, T23) Safety area installation EPL: Gb (Gas - Zone 1) Ex Certificates ATEX II 2G Ex ia IIB T4 Gb IECEx Ex ia IIB T4 Gb Ta = -40 °C to 60°C Korea (KCs) Ex ia IIB T4 -40°C ≤ Tamb ≤ +60°C Japan (CSA) Ex ia IIB T4 Gb (Ta = -40 °C to 60 °C) Electromagnetic compatibility according EN61326-1 EN61326-2-3 Industrial Environment Dimensions in mm (inches) 163 (6.42“) 90 (3.54“) 70 (2.76“)L Model T1 Probe of model T3 Probe of model T23 48 (1.89“) 12 (0.47“) 94 (3.70“) L L 106 (4.17“) L = filter cap Length in mm Membrane filter 34 (1.4“) Stainless steel sinter filter 33 (1.3“) PTFE filter 33 (1.3“) M12 connector optional mounting flange
v1.4 / Modification rights reservedEE100Ex 169 Ordering Guide EE100Ex- Hardware Model wall mount T1 fixed remote probe T3 pluggable interchangeable remote probe T23 Filter membrane F2 stainless steel sintered F4 PTFE F5 Probe cable length1) 1 m (3.3 ft) K1 2 m (6.6 ft) K2 3 m (9.8 ft) K3 Electrical connection one cable gland M16 x 1.5 E29 one cable gland M20 x 1.5 E30 two cable glands M16 x 1.5 E22 two cable glands M20 x 1.5 E21 Ex-approval KCs (Korea) EX5 CSA (Japan) EX6 ATEX and IECEx EX8 Software Measurand output 12) relative humidity RH [%] MA10 temperature T [°C] MA1 temperature T [°F] MA2 dew point Td [°C] MA52 dew point Td [°F] MA53 frost point Tf [°C] MA65 frost point Tf [°F] MA66 Scaling out 1 low value SAL value Scaling out 1 high value SAH value Measurand output 2 relative humidity RH [%] MB10 temperature T [°C] MB1 temperature T [°F] MB2 dew point Td [°C] MB52 dew point Td [°F] MB53 frost point Tf [°C] MB65 frost point Tf [°F] MB66 Scaling out 2 low value SBL value Scaling out 2 high value SBH value 1) cable: fixed for T3 version, pluggable and interchangeable for T23 version (only cable supplied by E+E is allowed). 2) assign the most relevant measurand parameter to output 1. Output 1 must always be connected Protection cap for 12 mm probe HA010783 Plastic mounting flange Ø12 mm (0.47“), black HA010214 Wall mounting plastic clip Ø12 mm (0.47“) HA010211 Safety barrier, 1-channel, STAHL 9002/13-280-093-001 HA011410 Intrinsically safe supply unit, 1-channel, PC MACX MCR-EX-SL-RPSSI-I HA011411*) Intrinsically safe supply unit, 2-channel, PC MACX MCR-EX-SL-RPSS-2I-2I HA011412*) Intrinsically safe supply unit, 1-channel, STAHL 9160/13-11-11 HA011405 Intrinsically safe supply unit, 2-channel, STAHL 9160/23-11-11 HA011406 Sealing plug for unused M16 cable glands HA011402 Sealing plug for unused M20 cable glands HA011404 Product Configuration Software EE-PCS (free download: www.epluse.com/configurator) Adapter kit for configuration and adjustment consisting of (see datasheet EE-PCA): Pos. 1: Product Configuration Adapter EE-PCA Pos. 2 : Connection cable HA011068 *) Only for ATEX and IECEx Accessories
v1.4 / Modification rights reserved EE100Ex 170 Order Example EE100Ex-T1F2E22EX8MA10SAL0SAH100MB1SBL0SBH50 Model: wall mount Filter: membrane Electrical Connection: two cable glands M16 x 1.5 Ex-Approval: ATEX / IECEx Measurand output 1: relative humidity RH [%] Scaling out 1 low: 0 Scaling out 1 high: 100 Measurand output 2: temperature [°C] Scaling out 2 low: 0 Scaling out 2 high: 50 Spare parts (only for T23 version) EE100ExP- Filter membrane F2 stainless steel sintered F4 PTFE F5 M12 probe cable* 2 m (6.6 ft) HA010826 Replacement probe * Only cable supplied by E+E is permitted.