DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Rev. 0.1 4/08 Copyright © 2008 by Silicon Laboratories AN346 AN346 Si47 XX E VALUATION B OARD Q UICK -S TART G UIDE Thank you for purchasing the Silicon Laboratories Si47xx FM Transmitter/AM/FM/SW/LW/WB Receiver Evaluation Board (EVB). The EVB and associated so ftware have been design ed to speed the overa ll development process and decrease required development time. We look forward to working with you and have posted support articles, answers to frequently asked questions, and applic ation notes on the Si47xx Customer Support Site at www.mysilabs.com. Note: A more comprehensive user's guide for configurin g your system is available on the EVB CD (Si47xx Evaluation Board User's Guide) and on the Si47xx Customer Support Site. If you have an y difficulty or questions about any of the steps below, please consult the EVB users guide prior to plugging in your EVB. 1. Make sure any prior versions of the GUI are removed prior to installation of the GUI application software shipped with the Si47xx EVB kit. - You can remove the old version of the GUI by going to "Add or Remove Programs" in the Windows control panel. 2. Insert the Silicon Laboratories CD into host CD drive. 3. Install the Development GUI lo cated in CD:\\Si47xx\\Setup.exe. 4. Connect the USB cable to the Si47xx EVB USB connector. 5. Make sure that switch SW1 is in the USB position to use USB power. 6. Launch the Si47xx Development GUI. 7. Once the GUI is launched, select the appropriate function (FM Transmitter/AM/FM/SW/LW/WB Receiver) and its associated firmware image to initialize the EVB. Refer to the user's guide for further information. 8. For optimum EVB performance, use the EVB with a 9 V ba ttery, or provide power via a USB cable plugged into a laptop. In the latter case, the laptop should be running off its own battery and should not be plugged into a wall socket. General Debugging Guidelines If your EVB is not functional, please refer to the following troubleshooting tips. 1. Make sure the EVB is recognized by your PC. Right-click on "My Computer", and select "Properties"  "Hardware"  "Device Manager". Under "Human Interface Devices", select each "HID-Compliant Device"  “Details" entry, and confirm one contains "VID_10C4&PID_8244". 2. If the EVB is not recogniz ed by the GUI, uninstall .NET Framework V2.0, and reinstall from Microsoft's Windows Update. AM/SW/LW Function-Specific Debugging Guidelines In the case that your EVB is noisy, refer to the following tro uble-shooting tips. The EVB User’s Guide will also provide additional suggestions and guidelines. 1. Disable "Update" under the "Control" menu (disables continuous Si47xx GUI updates and stops intermittent AM clicking noise). 2. Check GUI properties to verify set channel sp acing for region. This applies to AM and FM. 3. For optimum performance, use the 9 V battery pr ovided with the EVB, or use power from the USB. 4. If using a laptop, ensure that the laptop is running off the battery and is not plugged in to the ac outlet. 5. Make sure you are close to a window or outside in the open when evaluating AM reception. Large metal structures, such as buildings, interfere with AM reception; so, it is best to be away from these sources of interference.

Silicon Laboratories intends to provide customers with the latest, accurate, and in-depth documentation of all peripherals and modules available for system and software implementers using or intending to use the Silicon Laboratories products. Characterization data, available modules and peripherals, memory sizes and memory addresses refer to each specific device, and "Typical" parameters provided can and do vary in different applications. Application examples described herein are for illustrative purposes only. Silicon Laboratories reserves the right to make changes without further notice and limitation to product information, specifications, and descriptions herein, and does not give warranties as to the accuracy or completeness of the included information. Silicon Laboratories shall have no liability for the consequences of use of the information supplied herein. This document does not imply or express copyright licenses granted hereunder to design or fabricate any integrated circuits. The products must not be used within any Life Support System without the specific written consent of Silicon Laboratories. A "Life Support System" is any product or system intended to support or sustain life and/or health, which, if it fails, can be reasonably expected to result in significant personal injury or death. Silicon Laboratories products are generally not intended for military applications. Silicon Laboratories products shall under no circumstances be used in weapons of mass destruction including (but not limited to) nuclear, biological or chemical weapons, or missiles capable of delivering such weapons. Trademark Information Silicon Laboratories Inc., Silicon Laboratories, Silicon Labs, SiLabs and the Silicon Labs logo, CMEMS®, EFM, EFM32, EFR, Energy Micro, Energy Micro logo and combinations thereof, "the world’s most energy friendly microcontrollers", Ember®, EZLink®, EZMac®, EZRadio®, EZRadioPRO®, DSPLL®, ISOmodem ®, Precision32®, ProSLIC®, SiPHY®, USBXpress® and others are trademarks or registered trademarks of Silicon Laboratories Inc. ARM, CORTEX, Cortex-M3 and THUMB are trademarks or registered trademarks of ARM Holdings. Keil is a registered trademark of ARM Limited. All other products or brand names mentioned herein are trademarks of their respective holders. http://www.silabs.com Silicon Laboratories Inc.

400 West Cesar Chavez

Austin, TX 78701 USA Smart. Connected. Energy-Friendly Products www.silabs.com/products Quality www.silabs.com/quality Support and Community community.silabs.com