EUD-240SXXXBVA INVENTRONICS
Document overview
- Manufacturer or author: Provided By www.digicamel.com(free datasheet download site)
- PDF pages: 13
Technical content
Features
Ultra High Efficiency (Up to 94%) Full Power at Wide Output Current Range (Constant Power) Thermal Sensing and Protection for LED Module DALI/Timer Dimmable (3 Timer Modes) Dim-to-Off with Standby Power ≤ 0.5 W Always-on Auxiliary Power: 12Vdc, 200mA (Transient Peak Current up to 400mA) Output Lumen Compensation Input Surge Protection: 6kV line-line, 10kV line-earth All-Around Protection: OVP, SCP, OTP Waterproof (IP67) SELV Output Suitable for Independent Use 7 Years Warranty
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com I-V Operating Area EUD-240S105BVA EUD-240S150BVA EUD-240S210BVA EUD-240S420BVA EUD-240S670BVA
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Input Specifications Parameter Min. Typ. Max. Notes Input Voltage 90 Vac - 305 Vac 127-250 Vdc Input Frequency 47 Hz - 63 Hz Leakage Current - - 0.70 mA IEC60598-1; 240Vac/ 60Hz, grounding effectively Input AC Current - - 3.00 A Measured at full load and 100 Vac input. - - 1.30 A Measured at full load and 220 Vac input. Inrush Current(I2t) - - 2.60 A 2s At 220Vac input, 25℃ cold start, duration=840 μs, 10%Ipk-10%Ipk. See Inrush Current Waveform for the details. PF 0.90 - - At 100-240Vac, 50-60Hz, 60%-100% Load THD - - 10% At 220-240Vac, 50-60Hz, 75%-100% Load (180-240W) Output Specifications Parameter Min. Typ. Max. Notes Output Current Tolerance -5%Ioset - 5%Ioset At full load condition Output Current Setting(Ioset) Range EUD-240S105BVA EUD-240S150BVA EUD-240S210BVA EUD-240S420BVA EUD-240S670BVA 70 mA 105 mA 140 mA 280 mA 445 mA 1050 mA 1500 mA 2100 mA 4200 mA 6700 mA Output Current Setting Range with Constant Power EUD-240S105BVA EUD-240S150BVA EUD-240S210BVA EUD-240S420BVA EUD-240S670BVA 700 mA 1050 mA 1400 mA 2800 mA 4450 mA 1050 mA 1500 mA 2100 mA 4200 mA 6700 mA Total Output Current Ripple (pk-pk) - 5%Iomax 10%Iomax At full load condition, 20 MHz BW Output Current Ripple at < 200 Hz (pk-pk) - 2%Iomax - At full load condition. Only this component of ripple is associated with visible flicker. Startup Overshoot Current - - 10%Iomax At full load condition No Load Output Voltage EUD-240S105BVA EUD-240S150BVA EUD-240S210BVA EUD-240S420BVA EUD-240S670BVA 360 V 260 V 190 V 96 V 66 V Line Regulation - - ±0.5% Measured at full load Load Regulation - - ±1.5%
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Output Specifications (Continued) Parameter Min. Typ. Max. Notes Turn-on Delay Time - - 1.0 s Measured at 120Vac input, 60%-100% Load. - - 0.5 s Measured at 220Vac input, 60%-100% Load. Temperature Coefficient of Ioset - 0.03%/C - Case temperature = 0C ~Tc max 12V Auxiliary Output Voltage 10.8 V 12 V 13.2 V 12V Auxiliary Output Source Current 0 mA - 200 mA Return terminal is “OTP −“ 12V Auxiliary Output Transient Peak Current - - 400 mA 400mA peak for a maximum duration of 300ms in a 2s period during which time the average should not exceed 200mA. Note: All specifications are typical at 25C unless otherwise stated. General Specifications Parameter Min. Typ. Max. Notes Efficiency at 120 Vac input: EUD-240S105BVA Io= 700 mA Io=1050 mA EUD-240S150BVA Io=1050 mA Io=1500 mA EUD-240S210BVA Io=1400 mA Io=2100 mA EUD-240S420BVA Io=2800 mA Io=4200 mA EUD-240S670BVA Io=4450 mA Io=6700 mA 89.0% 88.0% 88.0% 87.0% 89.0% 87.5% 88.5% 87.0% 89.0% 87.0% 91.0% 90.0% 90.0% 89.0% 91.0% 89.5% 90.5% 89.0% 91.0% 89.0% Measured at full load and steady-state temperature in 25C ambient; (Efficiency will be about 2.0% lower if measured immediately after startup.) Efficiency at 220 Vac input: EUD-240S105BVA Io= 700 mA Io=1050 mA EUD-240S150BVA Io=1050 mA Io=1500 mA EUD-240S210BVA Io=1400 mA Io=2100 mA EUD-240S420BVA Io=2800 mA Io=4200 mA EUD-240S670BVA Io=4450 mA Io=6700 mA 92.0% 90.5% 91.0% 89.5% 91.5% 90.0% 91.0% 89.5% 91.0% 89.0% 94.0% 92.5% 93.0% 91.5% 93.5% 92.0% 93.0% 91.5% 93.0% 91.0% Measured at full load and steady-state temperature in 25C ambient; (Efficiency will be about 2.0% lower if measured immediately after startup.)
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com General Specifications (Continued) Parameter Min. Typ. Max. Notes Efficiency at 277 Vac input: EUD-240S105BVA Io= 700 mA Io=1050 mA EUD-240S150BVA Io=1050 mA Io=1500 mA EUD-240S210BVA Io=1400 mA Io=2100 mA EUD-240S420BVA Io=2800 mA Io=4200 mA EUD-240S670BVA Io=4450 mA Io=6700 mA 92.0% 91.0% 91.5% 90.0% 92.0% 90.5% 91.5% 90.0% 91.5% 89.0% 94.0% 93.0% 93.5% 92.0% 94.0% 92.5% 93.5% 92.0% 93.5% 91.0% Measured at full load and steady-state temperature in 25C ambient; (Efficiency will be about 2.0% lower if measured immediately after startup.) Standby power - - 0.5 W Measured at 230Vac/50Hz; Dimming off MTBF - 228,000 Hours - Measured at 220Vac input, 80%Load and 25C ambient temperature (MIL-HDBK- 217F) Lifetime - 96,000 Hours - Measured at 220Vac input, 80%Load and 70C case temperature; See lifetime vs. Tc curve for the details Operating Case Temperature for Safety Tc_s -40°C - +90°C Operating Case Temperature for Warranty Tc_w -40°C - +75 C Case temperature for 7 years warranty. Please see Inventronics Warranty Statement for complete details. Storage Temperature -40°C - +85°C Humidity: 5%RH to 100%RH Dimensions Inches (L × W × H) Millimeters (L × W × H) 8.63 × 2.66 × 1.57 219 × 67.5 × 39.7 With mounting ear 9.45 × 2.66 × 1.57 240 × 67.5 × 39.7 Net Weight - 1300 g - Note: All specifications are typical at 25C unless otherwise stated. Dimming Specifications Parameter Min. Typ. Max. Notes DA, DA High Level 9.5V 16V 22.5V DA, DA Low Level -6.5V 0V 6.5V DA, DA Current 0mA - 2mA
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Dimming Specifications (Continued) Parameter Min. Typ. Max. Notes Dimming Output Range EUD-240S105BVA EUD-240S150BVA EUD-240S210BVA EUD-240S420BVA EUD-240S670BVA 10%Ioset - Ioset 700 mA ≤ Ioset ≤ 1050 mA 1050 mA ≤ Ioset <1500 mA 1400 mA ≤ Ioset ≤ 2100 mA 2800 mA ≤ Ioset ≤ 4200 mA 4450 mA ≤ Ioset ≤ 6700 mA EUD-240S105BVA EUD-240S150BVA EUD-240S210BVA EUD-240S420BVA EUD-240S670BVA 70 mA 105 mA 140 mA 280 mA 445 mA - Ioset 70 mA ≤ Ioset < 700 mA 105 mA ≤ Ioset <1050 mA 140 mA ≤ Ioset <1400 mA 280 mA ≤ Ioset <2800 mA 445 mA ≤ Ioset <4450 mA Note: All specifications are typical at 25 C unless stated otherwise. Standards Compliance Safety Category Standard CE EN 61347-1, EN61347-2-13 KS KS C 7655 EMI Standards Notes EN 55015(1) Conducted emission Test &Radiated emission Test EN 61000-3-2 Harmonic current emissions EN 61000-3-3 Voltage fluctuations & flicker EMS Standards Notes EN 61000-4-2 Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge EN 61000-4-3 Radio-Frequency Electrom agnetic Field Susceptibility Test-RS EN 61000-4-5 Surge Immunity Test: AC Power Line: line to line 6 kV, line to earth 10 kV (2) EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS EN 61000-4-8 Power Frequency Magnetic Field Test EN 61000-4-11 Voltage Dips EN 61547 Electromagnetic Immunity Require ments Applies To Lighting Equipment DALI Standards Notes DALI IEC62386-101,102 & part of 207 (3) Note: (1) This LED driver meets the EMI specifications above , but EMI performance of a luminaire that contains it depends also on the other devices connected to the driver and on the fixture itself. (2) To perform electric strength (hi-pot) testing, the “G DT ground disconnect” (nut and metal lock sheet) on the driver end-cap should be removed temporarily to preven t the internal gas discharge tube from conducting (as allowed by IEC 60598-1 Clause 10.2). After testing is completed, these items must be reinstalled to restore line-to-earth surge protection and secure the end cap. (3) Optional Commands Implemented: 242 (query short circuit), 243 (query open circuit)
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Derating Lifetime vs. Case Temperature Inrush Current Waveform
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Efficiency vs. Load EUD-240S105BVA(Io=700mA) EUD-240S105BVA(Io=1050mA) EUD-240S150BVA(Io=1050mA) EUD-240S150BVA(Io=1500mA) EUD-240S210BVA(Io=1400mA) EUD-240S210BVA(Io=2100mA)
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUD-240S420BVA(Io=2800mA) EUD-240S420BVA(Io=4200mA) EUD-240S670BVA(Io=4450mA) EUD-240S670BVA(Io=6700mA) Power Factor
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Total Harmonic Distortion Protection Functions Parameter Min. Typ. Max. Notes External Thermal Protection NTC R1 - 7.81 kOhm - When R_NTC falls below R1, External Thermal Protection is triggered, reducing output current until R2 is reached. R2 - 4.16 kOhm - When R_NTC is less than R2, output current is reduced to the programmed “Protection Current Floor.” Protection Current Floor 10%Ioset 60%Ioset 100%Ioset 10%Ioset > Iomin (default setting is 60%) Iomin 60%Ioset 100%Ioset 10%Ioset ≤Iomin (default setting is 60%) Over Temperature Protection Decreases output current, retu rning to normal after over temperature is removed. Short Circuit Protection Auto Recovery. No damage will occur when any output is short circuited. The output shall return to normal when the fault condition is removed. Over Voltage Protection Limits output voltage at no load and in case the normal voltage limit fails. Dimming DALI Dimming The recommended implementation of the dimming control is provided below.
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Implementation: DALI Dimming Time Dimming Time dimming control includes 3 kinds of modes, they are Self Adapting-Midnight, Self Adapting- Percentage and Traditional Timer. Self Adapting-Midnight: Automatically adjusts the dimming curve based on the on-time of past two days (if difference <15 minutes), assuming that the center point of the dimming curve is midnight local time. Self Adapting-Percentage: Automatically adjusts the on-time of each step by a constant percentage = (actual on-time for the past 2 days if difference <15 min) / (programmed on-time from the dimming curve). Traditional Timer: Follows the programmed timing curve after power on with no changes. Output Lumen Compensation Output Lumen Compensation (OLC) may be used to maintain constant light output over the life of the LEDs by driving them at a reduced current when new, then gradually increasing the drive current over time to counteract LED lumen degradation. Programming Connection Diagram
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com Note: (1) The driver does not need to be powered on during the programming process. (2) Both “OTP-” and “DA” (gray) should be connected to “Return” of the programmer when programming. Please refer to PRG-MUL2 (Programmer) datasheet for details Mechanical Outline PROJ: Unspecified tolerance:±1 OUTPUT(VDE H05RN-F 2*1.0mm2 6.8) INPUT(VDE H05RN-F 3*1.0mm2 7.2) AC/L(BROWN) AC/N(BLUE) GND (YELLOW/GREEN) V+(BROWN) V- (BLUE) PURPLE GRAY BLUE/WHITE PINK BLACK/WHITE DIMMING WIRE(VDE 5*0.5mm2 7.2) Tc RoHS Compliance Our products comply with the European Directive 2011/65/EC, calling for the elimination of lead and other hazardous substances from electronic products.
Specifications are subject to changes without notice. 240W Programmable IP67 Driver with DALI EUD-240SxxxBVA Rev.D www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com
Revision History
Date Rev. Description of Change Item From To 2017-03-07 A Datasheets Release / / 2017-08-21 B EUD-240S150BVA / Added Input Specifications PF/THD Updated Temperature Coefficient of Ioset / Updated 2017-10-26 C Features 7 Years Warranty Added General Specifications Operating Case Temperature for Warranty Tc_w Updated 2018-01-30 D Description / Updated General Specifications Lifetime Updated Operating Case Temperature for Warranty Tc_w +70C +75 C Lifetime vs. Case Temperature / Updated