DESCRIPTION

NEC's UPG183GR is intended for use in Direct Broadcast Satellite (DBS) applications within the Low Noise Block (LNB) down converter, for systems where at least two LNB outputs are required. It offers four intermediate frequency amplifier channels that can independently select 1 of 4 IF inputs. It is housed in a very small 16 pin plastic HTSSOP package, available on tape- and-reel, easy to install and contributes to miniaturizing the systems. California Eastern Laboratories UPG183GRGaAs MMIC DBS 4X2 IF SWITCH OUTLINE DIMENSIONS (Units in mm)FEATURES

  • FOUR INDEPENDENT IF CHANNELS
  • INTEGRAL SWITCHING TO CHANNEL INPUT TO EITHER CHANNEL OUTPUT
  • INSERTION LOSS PER CHANNEL: 7 dB TYP (ZO = 50 Ω)
  • FREQUENCY RANGE:

950 MHz to 2150 MHz

  • CHANNEL TO CHANNEL ISOLATION: 26.5 dB TYP
  • SMALL 16 PIN HTSSOP PACKAGE PART NUMBER UPG183GR PACKAGE OUTLINE 16 pin HTSSOP SYMBOLS PARAMETERS AND CONDITIONS UNITS MIN TYP MAX LINS 1 Insertion Loss 1, f = 0.95 GHz to 1.5 GHz dB — 7.0 9.0 LINS 2 Insertion Loss 2, f = 1.5 GHz to 2.15 GHz dB — 8.0 10.0 ∆LINS Insertion Loss Flatness, | LINS (0.95 GHz)—L INS (2.15 GHz)| dB — 1.5 3.0 ISOL 1 Channel Isolation 1, f = 0.95 GHz to 1.5 GHz dB 24 26.5 — ISOL 2 Channel Isolation 2, f = 1.5 GHz to 2.15 GHz dB 22 23.5 — RL(OUT) Output Return Loss, f = 0.95 GHz to 2.15 GHz dB 10 14 — ICONT Control Current1, VCONT = +5 V/0 V, RFoff mA — — 0.5 16 pin HTSSOP

ELECTRICAL CHARACTERISTICS

(TA = +25°C, unless otherwise specified, VCONT1 to VCONT8 = 0/+5 V, PIN = 0 dBm, ZO = 50 Ω, Each Port) Notes: 1. Per one control pin. 0.9±0.2 0.20±0.106.4±0.3 5.5±0.3 5.2±0.2 0.65±0.1 0.20±0.10 1.5 1.8 0.4 0.5 2.7 0.1 2.5 N 9 8 16 1

SYMBOLS PARAMETERS UNITS MIN TYP MAX VCONT(H) Control Voltage (High) V +4.5 +5 +5.5 VCONT(L) Control Voltage (Low) V -0.5 0 +0.5 RECOMMENDED OPERATING CONDITIONS (TA = +25°C) ON CHANNEL CONTROL PIN OUT1 OUT2 V CONT1 VCONT2 VCONT3 VCONT4 VCONT5 VCONT6 VCONT7 VCONT8 IN-A – High Low High Low – – – – IN-B – High Low Low High – – – – IN-C – Low High High Low – – – – IN-D – Low High Low High – – – – – IN-A –––– High Low High Low – IN-B –––– High Low Low High – I N - C–––– L o w High High Low – I N - D–––– L o w High Low High CHANNEL SELECT TRUTH TABLE 51pF 51pF 51pF 51pF VCOUNT1, VCOUNT2, VCOUNT3, VCOUNT4, 1000 pF 1000 pF OUT1 OUT2 IN-A IN-B IN-C IN-D VCOUNT5, VCOUNT6, VCOUNT7, VCOUNT8 ZO=50 Ω ZO=50 Ω 50 Ω 51 pF 50 Ω 51 pF EVALUATION CIRCUIT (VCONT1 to VCONT8 = 0/+5 V, PIN = 0d Bm, ZO = 50 Ω, DC Blocking Capacitor = 51 pF) ABSOLUTE MAXIMUM RATINGS1 (TA = +25°C) Notes: 1. Operation in excess of any one of these parameters may result in permanent damage. 2. Mounted on a 50x50x1.6 mm double copper clad epoxy glass PWB, T A = +85°C. SYMBOLS PARAMETERS UNITS RATINGS VCONT1-8 Control Voltage 1-8 V -1.0 to +6.0 PTOT Total Power Dissipation2 W2 PIN Input Power dBm + 10 TA Operating Ambient Temp. °C -40 to +85 TSTG Storage Temperature °C -65 to +150

PART NUMBER PACKAGE QUANTITY UPG183GR-E1-A 16-pin Plastic HTSSOP Qty. 3k pcs/Reel

ORDERING INFORMATION

Notes: 1. Carrier tape, 12 mm wide. EXCLUSIVE NORTH AMERICAN AGENT FOR RF, MICROWAVE & OPTOELECTRONIC SEMICONDUCTORS CALIFORNIA EASTERN LABORATORIES  Headquarters  4590 Patrick Henry Drive  Santa Clara, CA 95054-1817  (408) 988-3500  Telex 34-6393  FAX (408) 988-0279 24-Hour Fax-On-Demand: 800-390-3232 (U.S. and Canada only)  Internet: http://WWW.CEL.COM 02/01/2001DATA SUBJECT TO CHANGE WITHOUT NOTICE PIN NO. CONNECTION PIN NO. CONNECTION

1 IN-C 9 OUT1

2 GND 10 V

3 IN-D 11 V CONT3

8 OUT2 16 IN-B

PIN CONNECTION AND INTERNAL BLOCK DIAGRAM TOP VIEW 16 15 14 13 12 11 10 9 12 34 567 8 SW SW Life Support Applications These NEC products are not intended for use in life support devices, appliances, or systems where the malfunction of these products can reasonably be expected to result in personal injury. The customers of CEL using or selling these products for use in such applications do so at their own risk and agree to fully indemnify CEL for all damages resulting from such improper use or sale.

4590 Patrick Henry Drive

Santa Clara, CA 95054-1817 Telephone: (408) 919-2500 Facsimile: (408) 988-0279 Subject: Compliance with EU Directives CEL certifies, to its knowledge, that semiconductor and laser products detailed below are compliant with the requirements of European Union (EU) Directive 2002/95/EC Restriction on Use of Hazardous Substances in electrical and electronic equipment (RoHS) and the requirements of EU Directive 2003/11/EC Restriction on Penta and Octa BDE. CEL Pb-free products have the same base part number with a suffix added. The suffix –A indicates that the device is Pb-free. The –AZ suffix is used to designate devices containing Pb which are exempted from the requirement of RoHS directive (*). In all cases the devices have Pb-free terminals. All devices with these suffixes meet the requirements of the RoHS directive. This status is based on CEL’s understanding of the EU Directives and knowledge of the materials that go into its products as of the date of disclosure of this information. Restricted Substance per RoHS Concentration Limit per RoHS (values are not yet fixed) Concentration contained in CEL devices -A -AZLead (Pb) < 1000 PPM Not Detected (*) Mercury < 1000 PPM Not Detected Cadmium < 100 PPM Not Detected Hexavalent Chromium < 1000 PPM Not Detected PBB < 1000 PPM Not Detected PBDE < 1000 PPM Not Detected If you should have any additional questions regarding our devices and compliance to environmental standards, please do not hesitate to contact your local representative. Important Information and Disclaimer: Information provided by CEL on its website or in other communications concerting the substan ce content of its products represents knowledge and belief as of the date that it is provided. CEL bases its knowledge and belief on information provided by third parties and makes no representation or warranty as to the accuracy of such information. Efforts are underway t o better integrate information from third parties. CEL has taken and continues to take reasonable steps to provide representative and ac curate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. CEL and CEL suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall CEL’s liability arising out of such information exceed the total purchase price of the CEL part(s) at issue sold by CEL to customer on an annual basis. See CEL Terms and Conditions for additional clarification of warranties and liability.