PH5551A2NA1-E4 CEL | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 11

Technical content

R08DS0037EJ0100 Rev.1.00 Page 1 of 10 Aug 03, 2011 Preliminary PH5551A2NA1-E4 Data Sheet Ambient Illuminance Sensor

DESCRIPTION

The PH5551A2NA1-E4 is a digital ambient illuminance sensor for I 2C bus interfaces and includes a 16-bit AD converter. This product has spectral characteristics close to human eye sensitivity and outputs digital signals corresponding to the ambient brightness. The PH5551A2NA1-E4 can be used to improve the performance and reduce the power consumption of digital equipment such as FPD TV sets and mobile phones, by enabling automatic brightness control and automatic switching on and off of lighting systems.

FEATURES

 Small and thin SON package 2.55 x 1.56 x 0.55 mm  Built-in 16-bit AD converter  I2C bus interface  Spectral characteristics close to human eye sensitivity Peak sensitivity wavelength 560 nm TYP.  Wide illuminance range 1 to 65,535 lx  I2C slave address selectable 2 types  Interrupt function  Pb-free

APPLICATIONS

 FPD TV sets, displays  Mobile phones, smartphones  Notebook PCs, tablet PCs  DSCs, DVCs  FA equipments  Lighting systems, etc. R08DS0037EJ0100 Rev.1.00 Aug 03, 2011

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 2 of 10 Aug 03, 2011 PACKAGE DIMENSIONS (UNIT: mm) Pin No. Terminal I/O Function

1 VDD  Supply Voltage

2 GND  GND

3 ADDR_SEL I Slave Address (2 addresses selectable)

4 SCL I I2C bus SCL

5 INT O Interrupt

6 SDA IO I2C bus SDA

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 3 of 10 Aug 03, 2011 ABSOLUTE MAXIMUM RATINGS (TA = 25C, unless otherwise specified) Parameter Symbol Ratings Unit Supply Voltage VDD 4.5 V Power Dissipation*1 PD 135 mW Operating Temperature TA 30 to +85 C Storage Temperature Tstg 40 to +100 C Note: *1. Mounted on glass epoxy board (18 mm  13 mm  t0.8 mm) RECOMMENDED OPERATING CONDITIONS Parameter Symbol MIN. TYP. MAX. Unit Supply Voltage VDD 2.4 3.0 3.6 V ELECTRO-OPTICAL CHARACTERISTICS (TA = 25C, VDD = 3.0 V, unless otherwise specified) Parameter Symbol Conditions MIN. TYP. MAX. Unit Supply Current 1 IDD1 Ev = 100 lx *1 130 290 A Supply Current 2 IDD2 Ev = 100 lx *1, power-down 1 A Dark Sensor Output  Ev = 0 lx 4 count Peak Sensitivity Wavelength p 560 nm H-Resolution Mode Resolution HRM 1 lx L-Resolution Mode Resolution LRM 16 lx Measurement Time in H-Resolution Mode HRt 330 495 ms Measurement Time in L-Resolution Mode LRt 21 32 ms I2C SCL Clock Frequency fSCL 400 kHz I2C Bus Free Time tBUF 1.3 s I2C Hold Time for START Condition tHDSTA 0.6 s I2C Set-up Time for START Condition tSUSTA 0.6 s I2C Set-up Time for STOP Condition tSUSTO 0.6 s I2C Data Hold Time tHDDAT 0 0.9 μs I2C Data Set-up Time tSUDAT 100 ns I2C „L‟ Period of the SCL Clock tLOW 1.3 s I2C „H‟ Period of the SCL Clock tHIGH 0.6 s I2C „L‟ Output Voltage at SDA VOL 0 0.4 V Note: *1 Fluorescent light

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 4 of 10 Aug 03, 2011 I2C BUS INTERFACE SPECIFICATION 1. I2C Bus Interface Timing Chart 2. Slave Address Two slave addresses are selectable. The slave address is determined by the ADDR_SEL pin. When ADDR_SEL “H”, the address is “1100100”. When ADDR_SEL  “L”, the address is “0111001”. 3. I2C Protocols (1) Write Format (2) Read Format

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 5 of 10 Aug 03, 2011 INSTRUCTION CODE AND REGISTER MAP 1. Instruction Code The instruction code is specified after the slave address. 0 1 0 1 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 REG_SEL AP_CNT ADR_PTR PWR *1 Note: *1 There are two PWR bits, one in the instruction code and one in the control register. When one bit changes, the other bit also changes at the same time. (1) REG_SEL: Register selection for Write or Read operation Code Register Address Selection Write Operation Read Operation

00 Control Register Control Register Control Register

01 Measurement Register Control Register Measurement Register

10 Measurement Register  Measurement Register

(2) AP_CNT: Address Pointer Control Code Description 00 The address is fixed to the register address specified by ADR_PTR. 01 The register address is incremented when one item of data is written or read. 10 If these bits are read after being written, the current register address is output. (3) ADR_PTR: Register Address Specify the address of the register to be written or read by using these 3 bits. (4) PWR: Power On/Power Down Power on/Power down (1: Power on)

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 6 of 10 Aug 03, 2011 2. Register Map The register map is specified after the instruction code. (1) Control Register (a) Register Address: 000 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserved SWRST INTCLR INT_COND RSLTN INT_EN *2 PWR *1 Notes: *1 There are two PWR bits, one in the instruction code and one in the control register. When one bit changes, the other bit also changes at the same time. *2 There are two INT_EN bits in the control register. When one bit changes, the other bit also changes at the same time. SWRST : Register reset (Initial values are restored by setting this bit to 1.) INTCLR : Interrupt source clear (1: Clear interrupt source) INT_COND : Interrupt result (00: No comparison with threshold value; 01: Measured lux is lower than lower-limit threshold value; 11: Measured lux is higher than upper-limit threshold value.) RSLTN : Resolution selection (1 lx/16 lx) (0: 1 lx resolution; 1: 16 lx resolution) INT_EN : Interrupt enable/disable (1: Enable interrupts) PWR : Power on/Power down (1: Power on) (b) Register Address: 001 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Lower interrupt generation threshold when interrupts are enabled - Lower 8 bits (c) Register Address: 010 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Lower interrupt generation threshold when interrupts are enabled - Higher 8 bits (d) Register Address: 011 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Upper interrupt generation threshold when interrupts are enabled - Lower 8 bits (e) Register Address: 100 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Upper interrupt generation threshold when interrupts are enabled - Higher 8 bits

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 7 of 10 Aug 03, 2011 (f) Register Address: 101 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserved Reserved Reserved STOP INT_COUNT INT_AT_RT INT_EN*1 Note: *1 There are two INT_EN bits in the control register. When one bit changes, the other bit also changes at the same time. STOP : Stops lux measurement after the current ADC cycle. The lux data measured last is retained. The ADC enters standby mode.(1: Stop) INT_COUNT : How many times the upper or lower threshold value is exceeded in succession before an interrupt signal is generated. (00: Once; 01: 4 times; 10: 8 times; 11: 16 times) INT_AT_RT : Automatic restoration from interrupt enable/disable (0: Processing automatically restored; 1: Processing not automatically restored (restored after the interrupt is cancelled by the system)) INT_EN : Interrupt enable/disable (0: Disable interrupts; 1: Enable interrupts) 3. Measurement Register (a) Register Address: 000 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Measurement of lux - lower 8 bits (read only) (b) Register Address: 001 0 0 0 0 0 0 0 0 Default Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Measurement of lux - higher 8 bits (read only)

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 8 of 10 Aug 03, 2011 TAPING SPECIFICATIONS (UNIT: mm)

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 9 of 10 Aug 03, 2011 RECOMMENDED MOUNT PAD DIMENSIONS (Unit: mm)

PH5551A2NA1-E4 Chapter Title R08DS0037EJ0100 Rev.1.00 Page 10 of 10 Aug 03, 2011 NOTES ON HANDLING 1. Recommended reflow soldering conditions (including infrared reflow, convection reflow, and infrared + convection reflow) (1) This product is dry-packed with desiccant in order to avoid moisture absorption. (2) After breaking the seal, reflow soldering must be done within 168 hours under the recommended temperature profile shown below. (3) If more than 168 hours have passed after breaking the seal, the baking process must be done by using a tape and reel. Baking conditions: Once, with tape and reel, 605C, 10 to 24 hours After the baking process, this product must be stored under conditions of 30 C or below, 70% RH or below, and reflow soldering must be done within 168 hours. <Storage conditions after breaking seal>  Storage conditions : 30C or below, 70% RH or below  Maximum storage period after breaking seal : 168 hours (Second reflow soldering must be completed within 168 hours.) <Reflow soldering conditions>  Peak reflow temperature : 260C or below (Package surface temperature)  Maximum number of reflows : 2  No repair by hand soldering  Maximum chlorine content of rosin flux (percentage mass) : 0.2% or less

All trademarks and registered trademarks are the property of their respective owners. C - 1 Rev. Date

1.00 Aug 03, 2011  First edition issued