AC/DC Power Supply TXM 200 Series, 200 Watt

  • Compact 200 Watt metal cased power supplies
  • Fully convection cooled power supplies
  • Cost efficient design
  • High operating temperature up to 65°C
  • Universal AC input 90 - 264 VAC
  • Active power factor correction >0.95
  • Withstand 300 VAC surge input for 5 s
  • Adjustable output voltage
  • Over current limitation and short circuit protection
  • 3-year product warranty IEC 62368-1UL 62368-1 The TXM 200 series is a family of 200 Watt encased AC/DC power supplies designed for cost critical applications. It extends the existing TXM series which ranged from 15 to 150 Watt with an additional 200 Watt series. With a com- pact metal case and screw terminal block connections, they are easy to install in any equipment. There are three models of single output voltages from 12 VDC to 48 VDC. They also feature an universal input and comply with EN 55032 class B and the latest IEC/UL 60950-1 edition to cover a wide range of applications. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TXM 200-112 200 W 12 VDC (10.0 - 15.5 VDC) 16'700 mA 87 % TXM 200-124 202 W 24 VDC (20.0 - 27.2 VDC) 8'400 mA 88 % TXM 200-148 48 VDC (42.0 - 53.0 VDC) 4'200 mA 89 % www.tracopower.com March 16, 2023 Page 1 / 5

Input Voltage - AC Range Operational Range: 90 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 120 - 375 VDC (Designed for, no certification) Polarity: irrelevant (Surge voltage (5 s max.): 300 VAC max.) Input Frequency Operational Range: 47 - 63 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 115 VAC 3'000 mA max. Power Consumption - No load & Vin = 230 VAC 3'000 mW max. - No load & Vin = 115 VAC 2'500 mW max. Input Inrush Current - At 230 VAC 50 A max. - At 115 VAC 30 A max. Power Factor - At 230 VAC 0.95 min. (Active Power Factor Correction) - At 115 VAC 0.98 min. (Active Power Factor Correction) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Specifications Output Voltage Adjustment 12 VDC model: 10.0 - 15.5 VDC 24 VDC model: 20.0 - 27.2 VDC 48 VDC model: 42.0 - 53.0 VDC (By trim potentiometer) Output power must not exceed rated power! Voltage Set Accuracy ±1% max. (24 & 48 VDC models) ±2 % max. (12 VDC models) Regulation - Input Variation (Vmin - Vmax) 0.5% max. - Load Variation (0 - 100%) 1% max. (24 & 48 VDC models) 2% max. (12 VDC model) Ripple and Noise (20 MHz Bandwidth) 12 VDC model: 150 mVp-p max. (w/ 0.1 µF || 10 µF) 24 VDC model: 200 mVp-p max. (w/ 0.1 µF || 10 µF) 48 VDC model: 150 mVp-p max. (w/ 0.1 µF || 10 µF) Minimum Load Not required Temperature Coefficient ±0.03 %/K max. Hold-up Time - At 230 VAC 16 ms min. - At 115 VAC 16 ms min. Start-up Time - At 230 VAC 2'000 ms max. - At 115 VAC 4'000 ms max. Start-up Overshoot Voltage 5% max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 105 - 150% of Iout max. Transient Response - Response Deviation 5% max. (75% to 100% Load Step) - Response Time 400 µs typ. (75% to 100% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/txm200 Protection Class Class I (Prepared): Connection to PE Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications TXM 200 Series, 200 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 5

EMI Emissions - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class D - Voltage Fluctuations & Flicker EN 61000-3-3 EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria B Contact: EN 61000-4-2, ±4 kV, perf. criteria B - RF Electromagnetic Field EN 61000-4-3, 3 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±1 kV, perf. criteria B L to L: EN 61000-4-5, ±1 kV, perf. criteria B L to PE: EN 61000-4-5, ±2 kV, perf. criteria B - Conducted RF Disturbances EN 61000-4-6, 3 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 1 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria C >95%, 0.5 periods, perf. criteria B >95%, 250 periods, perf. criteria C EMC Specifications Relative Humidity 90% max. (non condensing) Temperature Ranges - Operating Temperature –20°C to +65°C - Storage Temperature –40°C to +65°C (with derating) Power Derating - High Temperature 3.3 %/K above 50°C - Low Input Voltage 0.8 %/V below 115 VAC See application note: www.tracopower.com/overview/txm200 Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. Switching Frequency 80 - 85 kHz (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 494 VAC Isolation Test Voltage - Input to Output, 60 s 3'000 VDC - Input to Case or PE, 60 s 1'500 VAC - Output to Case or PE, 60 s 500 VAC Creepage - Input to Output 8 mm min. Clearance - Input to Output 8 mm min. Isolation Resistance - Input to Output, 500 VDC 100 MΩ min. Leakage Current - Earth Leakage Current 3500 µA max. - Touch Current 250 µA max. Reliability - Calculated MTBF 100'000 h (MIL-HDBK-217F, ground benign) Housing Material Aluminum Housing Type Metal Case Mounting Type Chassis Mount Connection Type Screw Terminal Weight 700 g General Specifications TXM 200 Series, 200 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 5

Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/txm200 TXM 200 Series, 200 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 4 / 5

TXM 200 Series, 200 Watt 199.0 (7.83) 99.0 (3.90) 9.5 (0.37) 8.0 (0.31) 1 138.0 (5.43) 85 (3.35) 8.0 (0.31) 2 x M3 50.3 (1.98) 188.5 (7.40) 25.0 (0.98) 25.0 (0.98) 150.0 (5.91) 4.2 (0.17) 116.5 (4.59) 3 x ø3.5 9.5 (0.37) 9 x M4 4.0 (0.16) Dimensions in mm (inch) Outside dimension tolerance: ±1.0 (±0.04) Screw Definition Installation Method Position No. Screw Size L max. Torque ma x. Bottom Installation 1-4 M3 3.5 (0.17) 6.5 kgfcm 5-6 M3 4.0 (0.16) 6.5 kgfcm Side Installation 7-8 M3 4.0 (0.16) 6.5 kgfcm 9-11 M4 4.0 (0.16) 12.0 kgfcm Pin-Out Pin Function

1 AC (N)

2 AC (L)

3 GND

4 – Vout 5 – Vout 6 – Vout 7 + Vout 8 + Vout 9 + Vout © Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 5 / 5