AC/DC Power Supply TMM 60 Series, 60 Watt

  • Fully encapsulated low profile plastic casing in PCB version
  • 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition
  • IT and industrial safety according to IEC/EN/UL 60950-1
  • Ready to meet ErP directive <0.3 W no load power consumption
  • –40°C start-up temperature
  • Safety class II prepared
  • Protection against over-temperature, overload and short circuit
  • 3-year product warranty IEC 60601-1 IEC 62368-1 ES 60601-1 UL 62368-1 UL 508 The TMM 60 Series of fully encapsulated 60 Watt AC/DC power supply mod- ules feature a reinforced/double I/O isolation system according to latest med- ical safety standards 60601-3 3rd edition for 2 x MOPP (Means Of Patient Pro- tection). The high efficiency and the use of highest grade components make the units suitable for an operating temperature range of –40°C to +60°C while it goes up to 75°C with 50% load derating. EMI/EMC characteristics and the safety ap- proval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in indus- trial an commercial environment. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. max. typ. TMM 60105 51 W 5.1 VDC 10'000 mA 84 % TMM 60112 60 W

12 VDC 5'000 mA 87 %

TMM 60115 15 VDC 4'000 mA 87 % TMM 60124 24 VDC 2'500 mA 87 % TMM 60148 48 VDC 1'250 mA 88 % www.tracopower.com March 16, 2023 Page 1 / 4

Input Voltage - AC Range Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 120 - 370 VDC (Designed for, no certification) Polarity: irrelevant Input Frequency Operational Range: 47 - 440 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 230 VAC 5.1 VDC model: 530 mA max. 12 VDC model: 600 mA max. 15 VDC model: 600 mA max. 24 VDC model: 600 mA max. 48 VDC model: 600 mA max. - Full Load & Vin = 115 VAC 5.1 VDC model: 880 mA max. 12 VDC model: 1'000 mA max. 15 VDC model: 1'000 mA max. 24 VDC model: 1'000 mA max. 48 VDC model: 990 mA max. Power Consumption - No load & Vin = 230 VAC 750 mW max. - No load & Vin = 115 VAC 500 mW max. Input Inrush Current - At 230 VAC 60 A max. - At 115 VAC 30 A max. Input Protection T 2 A / 250 VAC (Internal Fuse in L & N) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Specifications Voltage Set Accuracy ±2% max. Regulation - Input Variation (Vmin - Vmax) 1% max. - Load Variation (0 - 100%) 1% max. Ripple and Noise (20 MHz Bandwidth) 5.1 VDC model: 160 mVp-p max. 12 VDC model: 180 mVp-p max. 15 VDC model: 230 mVp-p max. 24 VDC model: 360 mVp-p max. 48 VDC model: 720 mVp-p max. 5.1 VDC model: 110 mVp-p typ. 12 VDC model: 120 mVp-p typ. 15 VDC model: 150 mVp-p typ. 24 VDC model: 240 mVp-p typ. 48 VDC model: 480 mVp-p typ. Capacitive Load 5.1 VDC model: 8'000 µF max. 12 VDC model: 3'900 µF max. 15 VDC model: 3'300 µF max. 24 VDC model: 1'500 µF max. 48 VDC model: 680 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Hold-up Time - At 230 VAC 50 ms min. - At 115 VAC 10 ms min. Start-up Overshoot Voltage 5% max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 105% min. of Iout max. Overvoltage Protection 120% typ. of Vout nom. (By Zener diode) Output Specifications TMM 60 Series, 60 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 4

Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Industrial Control Equipment UL 508 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 CSA-C22.2, No 60601-1 2 x MOPP (Means Of Patient Protection) - Certification Documents www.tracopower.com/overview/tmm60 Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications EMI Emissions EN 61000-6-3 (Generic Residential) EN 61000-6-4 (Generic Industrial) - Conducted Emissions EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15 class B (internal filter) - Radiated Emissions EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15 class B (internal filter) EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) EN 61000-6-1 (Generic Residential) EN 61000-6-2 (Generic Industrial) EN 60601-1-2 edition 4 (Medical Devices) - Electrostatic Discharge Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 1 period, perf. criteria A >95%, 250 periods, perf. criteria B EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +80°C - Storage Temperature –40°C to +95°C Power Derating - High Temperature 3.8 %/K above 60°C See application note: www.tracopower.com/overview/tmm60 Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. Switching Frequency 100 kHz typ. (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 240 VAC Isolation Test Voltage - Input to Output, 60 s 4'000 VAC Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. General Specifications TMM 60 Series, 60 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 4

Leakage Current - Touch Current 100 µA max. Reliability - Calculated MTBF 125'000 h (MIL-HDBK-217F, ground benign) Washing Process Not allowed Housing Material Plastic resin (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) Pin Material Copper Alloy (C6801) Pin Foundation Plating Nickel (2 - 4 µm) Pin Surface Plating Tin (3 - 5 µm), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Soldering Profile Wave Soldering 260°C / 10 s Weight 360 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tmm60 Outline Dimensions TMM 60 Series, 60 Watt Dimensions in mm (inch) Tolerances ±0.5 (±0.02) Pin pich tolerances ±0.25 (±0.01) 25.4 (1.00) 6 4 1 2 55.88 (2.20) 0.7 (0.03) 17.75 (0.70) 17.00 (0.67) 36.45 (1.44) 81.3 (3.20) 88.9 (3.50) Ø 1.0 (Ø 0.04) Mounting M4 Thread Bottom View Pinout Pin Function

1 AC (N)

2 AC (L)

6 –Vout © Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 4 / 4