AC/DC Power Supply TMPW 50 Series, 50 Watt

  • Compact PCB power module in 2.92" x 1.85" package
  • Wide input voltage range 90-305 VAC
  • Certified according to EN 60335-1 an IEC/EN/UL 62368-1
  • I/O-Isolation 4’000 VAC
  • Operating temperature range –40°C to +70°C
  • No load input power <0.1W (acc. ErP directive)
  • High efficiency up to 89%
  • Internal EN 55032 class B filter
  • Protection class II prepared
  • 3 year product warranty IEC 60335-1 IEC 62368-1 UL 62368-1 The TMPW 50 is a 50 Watt AC/DC series with an extended input range of 90-305 VAC and is suitable for industrial and household/building technology applications and comes in a compact encapsulated plastic case. The 305 VAC (277 VAC ±10%) threshold is derived from a 480 VAC three-phase supply volt- age often used in heavy industrial applications. Through the increased voltage level, the drawn current from the load is effectively reduced, which allows for an overall more compact and lightweight design approach. They offer an I/O-isolation voltage of 4000 VAC, a high temperature range of -40 to +70°C and are prepared for protection class II applications. Additionally, an internal EN 55032 class B filter saves valuable board space for an otherwise often mandatory external filter setup. An energy efficient design (<0.1 Watt standby power consumption) and safety approvals according to IEC/EN/UL 62368-1 and EN 60335-1 make this series suitable for a wide range of industrial and household/building technology applications. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. max. typ. TMPW 50-112 50 W

12 VDC 4'167 mA 89 %

TMPW 50-115 15 VDC 3'333 mA 88 % TMPW 50-124 24 VDC 2'083 mA 88 % www.tracopower.com November 30, 2022 Page 1 / 4

Input Voltage - AC Range Operational Range: 90 - 305 VAC (Full Range) Rated Range: 100 - 277 VAC (Full Range) - DC Range Operational Range: 100 - 430 VDC Certified Range: 100 - 250 VDC Polarity: irrelevant (The rated range refers to 62368-1. For 60335-1 certification the rated input voltage is 100 - 240 VAC and DC input is not permitted.) Input Frequency Operational Range: 47 - 440 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 230 VAC 600 mA max. - Full Load & Vin = 115 VAC 1'000 mA max. Power Consumption - No load & Vin = 230 VAC 100 mW max. (Ready to meet ErP directive) - No load & Vin = 115 VAC 100 mW max. Input Inrush Current - At 230 VAC 90 A max. - At 115 VAC 45 A max. Recommended Input Fuse 2'500 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Specifications Voltage Set Accuracy ±2% max. Regulation - Input Variation (Vmin - Vmax) 2% max. - Load Variation (0 - 100%) 2.5% max. Ripple and Noise (20 MHz Bandwidth) 12 VDC model: 120 mVp-p max. (w/ 0.1 µF // 47 µF) 15 VDC model: 150 mVp-p max. (w/ 0.1 µF // 47 µF) 24 VDC model: 240 mVp-p max. (w/ 0.1 µF // 47 µF) Capacitive Load 12 VDC model: 3'500 µF max. 15 VDC model: 3'000 µF max. 24 VDC model: 2'200 µF max. Minimum Load Not required Temperature Coefficient ±0.05 %/K max. Hold-up Time - At 230 VAC 10 ms min. Start-up Time - At 230 VAC 130 ms max. - At 115 VAC 130 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 130 - 215% of Iout max. Overvoltage Protection 105 - 145% of Vout nom. (By Zener diode) Transient Response - Response Deviation 2% typ. / 3% max. (50% to 75% Load Step) - Response Time 500 µs max. (50% to 75% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Household EN 60335-1 IEC 60335-1 - Power Transformers IEC 61558-1 IEC 61558-2-16 - Certification Documents www.tracopower.com/overview/tmpw50 Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications TMPW 50 Series, 50 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 4

EMI Emissions - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Voltage Fluctuations & Flicker EN 61000-3-3 EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±4 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 3 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±1 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 3 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 1 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria A >95%, 250 periods, perf. criteria B

115 VAC / 60 Hz: EN 61000-4-11

30%, 25 periods, perf. criteria A >95%, 250 periods, perf. criteria B EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +70°C - Storage Temperature –40°C to +85°C Power Derating - High Temperature 2.5 %/K above 50°C - Low Input Voltage 2 %/V below 100 VAC See application note: www.tracopower.com/overview/tmpw50 Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. (acc. IEC 62368-1) 2'000 m max. (acc. IEC 60335-1) Switching Frequency 55 - 90 kHz (PWM, PFM) Insulation System Reinforced Insulation Working Voltage (rated) 342 VAC Isolation Test Voltage - Input to Output, 60 s 4'000 VAC Leakage Current - Touch Current 250 µA max. Reliability - Calculated MTBF 300'000 h (MIL-HDBK-217F, ground benign) Washing Process Not allowed Environment - Vibration IEC 60068-2-6 2 g, 3 axis, 60 min, 10-500 Hz, 10 min/cycle - Mechanical Shock IEC 60068-2-27 Housing Material Plastic resin (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) (Hermetical sealed structure, dust-proof only non water-proof) Pin Material Brass Pin Surface Plating Tin (120 µm min.), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Weight 158 g General Specifications TMPW 50 Series, 50 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 4

Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tmpw50 Outline Dimensions TMPW 50 Series, 50 Watt Dimensions in mm (inch) Tolerances: x.x ±0.5 (±0.02) 1 4 22.8 (0.90) 20.0 (0.79) 47.0 (1.85) 4.20 (0.17) 11.3 (0.44) 74.2 (2.92) 23.1 (0.91) 8.0 (0.31) 62.0 (2.44) 11.5 (0.45) 24.2 (0.95) Ø1.0 (Ø0.04) 6.1 (0.24) Bottom View Pinout Pin Function

1 AC IN (N)

2 AC IN (L)

3 –Vout 4 +Vout © Copyright 2022 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 4 / 4