AC/DC Power Supply TMM 24 Series, 24 Watt

  • Fully encapsulated low profile plastic casing in PCB version
  • 2 x MOPP Medical safety according to AAMI/ANSI ES 60601-1:2005(R) and IEC/EN 60601-1 3rd edition
  • IT and industrial safety according to IEC/EN/UL 60950-1
  • Ready to meet ErP directive <0.3 W no load power consumption
  • –40°C start-up temperature
  • Safety class II prepared
  • Protection against over-temperature, overload and short circuit
  • 3-year product warranty IEC 60601-1 IEC 62368-1 ES 60601-1 UL 62368-1 UL 508 The TMM 24 Series of fully encapsulated 24 Watt AC/DC power supply mod- ules feature a reinforced/double I/O isolation system according to latest med- ical safety standards 60601-3 3rd edition for 2 x MOPP (Means Of Patient Pro- tection). The high efficiency and the use of highest grade components make the units suitable for an operating temperature range of –40°C to +65°C while it goes up to 75°C with 50% load derating. EMI/EMC characteristics and the safety ap- proval package qualify these modules not only for medical devices but also for demanding applications in transportation systems and for equipment in indus- trial an commercial environment. Models Order Code Output Output 1 Output 2 Efficiency Power Vnom Imax Vnom Imax TMM 24105 15 W 5 VDC 3'000 mA 77 % TMM 24112 24 W

12 VDC 2'000 mA 83 %

TMM 24115 15 VDC 1'600 mA 82 % TMM 24124 24 VDC 1'000 mA 85 % TMM 24212 +12 VDC 1'000 mA –12 VDC 1'000 mA 84 % TMM 24215 +15 VDC 800 mA –15 VDC 800 mA 84 % www.tracopower.com March 16, 2023 Page 1 / 5

Input Voltage - AC Range Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 120 - 370 VDC (Designed for, no certification) Polarity: irrelevant Input Frequency Operational Range: 47 - 440 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 230 VAC 5 VDC model: 170 mA max. 12 VDC model: 255 mA max. 15 VDC model: 255 mA max. 24 VDC model: 250 mA max. dual output models: 250 mA max. - Full Load & Vin = 115 VAC 5 VDC model: 285 mA max. 12 VDC model: 420 mA max. 15 VDC model: 425 mA max. 24 VDC model: 410 mA max. dual output models: 415 mA max. Power Consumption - No load & Vin = 230 VAC 750 mW max. - No load & Vin = 115 VAC 300 mW max. Input Inrush Current - At 230 VAC 40 A max. - At 115 VAC 20 A max. Input Protection T 2 A / 250 VAC (Internal Fuse in L & N) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Specifications Voltage Set Accuracy ±2% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.5% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 1% max. dual output models: 3% max. (Output 1) 3% max. (Output 2) Ripple and Noise (20 MHz Bandwidth) - single output 5 VDC model: 90 mVp-p max. 12 VDC model: 155 mVp-p max. 15 VDC model: 195 mVp-p max. 24 VDC model: 310 mVp-p max. - dual output 12 / -12 VDC model: 155 / 155 mVp-p max. 15 / -15 VDC model: 195 / 195 mVp-p max. - single output 5 VDC model: 80 mVp-p typ. 12 VDC model: 120 mVp-p typ. 15 VDC model: 150 mVp-p typ. 24 VDC model: 240 mVp-p typ. - dual output 12 / -12 VDC model: 120 / 120 mVp-p typ. 15 / -15 VDC model: 150 / 150 mVp-p typ. Capacitive Load - single output 5 VDC model: 2'200 µF max. 12 VDC model: 1'000 µF max. 15 VDC model: 680 µF max. 24 VDC model: 470 µF max. - dual output 12 / -12 VDC model: 470 / 470 µF max. 15 / -15 VDC model: 330 / 330 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Hold-up Time - At 230 VAC 50 ms min. - At 115 VAC 10 ms min. Start-up Overshoot Voltage 5% max. Short Circuit Protection Continuous, Automatic recovery Output Specifications TMM 24 Series, 24 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 5

Output Current Limitation 105% min. of Iout max. Overvoltage Protection 120% typ. of Vout nom. (By Zener diode) Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Industrial Control Equipment UL 508 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 CSA-C22.2, No 60601-1 2 x MOPP (Means Of Patient Protection) - Certification Documents www.tracopower.com/overview/tmm24 Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications EMI Emissions EN 61000-6-3 (Generic Residential) EN 61000-6-4 (Generic Industrial) - Conducted Emissions EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15 class B (internal filter) - Radiated Emissions EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15 class B (internal filter) EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) EN 61000-6-1 (Generic Residential) EN 61000-6-2 (Generic Industrial) EN 60601-1-2 edition 4 (Medical Devices) - Electrostatic Discharge Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A L to PE: EN 61000-4-5, ±1 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 1 period, perf. criteria A >95%, 250 periods, perf. criteria B EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +80°C - Storage Temperature –40°C to +95°C Power Derating - High Temperature 3.13 %/K above 65°C (5 Vin model) 5 %/K above 65°C (other models) See application note: www.tracopower.com/overview/tmm24 General Specifications TMM 24 Series, 24 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 5

  • Protection Mode 142°C typ. (Automatic recovery at 67°C typ.) - Measurement Point Internal IC temperature Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. Switching Frequency 132 kHz typ. (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 240 VAC Isolation Test Voltage - Input to Output, 60 s 4'000 VAC Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. Leakage Current - Touch Current 100 µA max. Reliability - Calculated MTBF 400'000 h (MIL-HDBK-217F, ground benign) Washing Process Not allowed Housing Material Plastic resin (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) Pin Material Copper Alloy (C6801) Pin Foundation Plating Nickel (2 - 4 µm) Pin Surface Plating Tin (3 - 5 µm), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Soldering Profile Wave Soldering 260°C / 10 s Weight 137 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tmm24 TMM 24 Series, 24 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 4 / 5

TMM 24 Series, 24 Watt Dimensions in mm (inch) Tolerances ±0.5 (±0.02) Pin pich tolerances ±0.25 (±0.01) 5 4 6 11.43 54.0 20.32 62.0 74.0 (0.45) (2.13) (0.80) Bottom view (2.44) (2.91) 27.0 (1.06) 11.43 (0.45) 2 x M4 THD 40.0 (1.57) 6.0 (0.24) 19.5 0.7 6.0 5.0 (0.03) (0.24) (0.77) (0.20) 5.0 (0.20) Pinout Pin Single Output Dual Output

1 AC (N) AC (N)

2 AC (L) AC (L)

4 –Vout –Vout

5 No pin Common

© Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 5 / 5