AC/DC Power Supply TXM 100 Series, 100 Watt
- Very compact metal cased power supplies
- High operating temperature up to 60°C
- Screw terminal block
- No internal fan
- Universal AC input, full range
- Active power factor correction >0.93
- Withstand 300 VAC surge input for 5 s
- Adjustable output voltage
- 3-year product warranty IEC 62368-1UL 62368-1 The TXM 100 series of 100 Watt is a family of enclosed AC/DC power supplies designed for cost critical applications. With a low profile metal case and screw terminal block connections, they are easy to install in any equipment. There are five models of single output voltages from 5 VDC to 48 VDC. These power sup- plies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TXM 100-105 100 W 5 VDC (3.3 - 5.5 VDC) 20'000 mA 84 % TXM 100-112 102 W 12 VDC (10.0 - 15.0 VDC) 8'500 mA 87 % TXM 100-115 105 W 15 VDC (13.5 - 17.0 VDC) 7'000 mA 87 % TXM 100-124 101 W 24 VDC (21.0 - 27.0 VDC) 4'200 mA 88 % TXM 100-148 106 W 48 VDC (43.2 - 52.8 VDC) 2'200 mA 88 % www.tracopower.com March 16, 2023 Page 1 / 4
Input Voltage - AC Range Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 120 - 375 VDC (Designed for, no certification) Polarity: irrelevant (Surge voltage (5 s max.): 300 VAC max.) Input Frequency Operational Range: 47 - 63 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 115 VAC 1'500 mA max. Power Consumption - No load & Vin = 230 VAC 5'100 mW max. - No load & Vin = 115 VAC 5'000 mW max. Input Inrush Current - At 230 VAC 50 A max. - At 115 VAC 30 A max. Power Factor - At 230 VAC 0.98 min. (Active Power Factor Correction) - At 115 VAC 0.93 min. (Active Power Factor Correction) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Specifications Output Voltage Adjustment 5 VDC model: 3.3 - 5.5 VDC 12 VDC model: 10.0 - 15.0 VDC 15 VDC model: 13.5 - 17.0 VDC 24 VDC model: 21.0 - 27.0 VDC 48 VDC model: 43.2 - 52.8 VDC (By trim potentiometer) Output power must not exceed rated power! Voltage Set Accuracy ±1% max. (24 & 48 VDC models) ±2 % max. (5, 12 & 15 VDC models) Regulation - Input Variation (Vmin - Vmax) 0.5% max. - Load Variation (0 - 100%) 1% max. (24 & 48 VDC models) 2% max. (5, 12 & 15 VDC models) Ripple and Noise (20 MHz Bandwidth) 150 mVp-p max. (w/ 0.1 µF || 10 µF) Minimum Load Not required Temperature Coefficient ±0.03 %/K max. Hold-up Time - At 230 VAC 12 ms min. Start-up Time - At 230 VAC 2'000 ms max. - At 115 VAC 4'000 ms max. Start-up Overshoot Voltage 5% max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 110 - 150% of Iout max. Transient Response - Response Deviation 5% max. (75% to 100% Load Step) - Response Time 400 µs typ. (75% to 100% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/txm100 Protection Class Class I (Prepared): Connection to PE Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications TXM 100 Series, 100 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 4
EMI Emissions - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class D - Voltage Fluctuations & Flicker EN 61000-3-3 EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria B Contact: EN 61000-4-2, ±4 kV, perf. criteria B - RF Electromagnetic Field EN 61000-4-3, 3 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±1 kV, perf. criteria B L to L: EN 61000-4-5, ±1 kV, perf. criteria B L to PE: EN 61000-4-5, ±2 kV, perf. criteria B - Conducted RF Disturbances EN 61000-4-6, 3 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 1 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria C >95%, 0.5 periods, perf. criteria B >95%, 250 periods, perf. criteria C EMC Specifications Relative Humidity 90% max. (non condensing) Temperature Ranges - Operating Temperature –20°C to +60°C - Storage Temperature –30°C to +85°C Power Derating - High Temperature 2.5 %/K above 40°C - Low Input Voltage 1 %/V below 100 VAC See application note: www.tracopower.com/overview/txm100 Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. Switching Frequency 100 kHz typ. (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 360 VAC Isolation Test Voltage - Input to Output, 60 s 3'000 VDC - Input to Case or PE, 60 s 1'500 VAC - Output to Case or PE, 60 s 500 VAC Creepage - Input to Output 6.2 mm min. Clearance - Input to Output 6.2 mm min. Isolation Resistance - Input to Output, 500 VDC 100 MΩ min. Leakage Current - Earth Leakage Current 3500 µA max. - Touch Current 250 µA max. Reliability - Calculated MTBF 200'000 h (MIL-HDBK-217F, ground benign) Housing Material Aluminum Housing Type Metal Case Mounting Type Chassis Mount Connection Type Screw Terminal Weight 455 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) General Specifications TXM 100 Series, 100 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 4
Overview Link (for additional Documents) www.tracopower.com/overview/txm100 Outline Dimensions TXM 100 Series, 100 Watt 5x Ø3.5 Assemble Screw SMPS Cover Customer plate L max. 129 (5.08) 121.5 (4.78) 33 (1.3) 99 (3.9) 85.5 (3.37) 31 (1.22 ) 17 (0.67) 4.5 Ø3.578 (3.07) 49.2 (1.94) 8.02 9.53 23.38 119.5 (4.7) 6.5 Ø3.5 20 (0.79) 29 (1.14) 20 86 (3.386) 18 11 38 (1.5) (0.18) (0.14) (0.32) (0.38) (0.28) (0.47) (0.26) (0.79) (0.71) (0.43) (0.92) (0.14) LED ADJ 3x M3 2x R 1.75 6x M3 Dimensions in mm (inch) Outside dimension tolerance: ±1.0 (±0.04) Screw Definition Installation Method Position No. Screw Size L max. Torque ma x. Bottom Installation 1-4 M3 5 (0.20) 7.0 kgfcm 9-10 M3 3 (0.12) 6.5 kgfcm Side Installation 11-13 M3 5 (0.20) 7.0 kgfcm 14-16 M3 3 (0.12) 6.5 kgfcm Pin-Out Pin Function
1 AC (L)
2 AC (N)
4 – Vout 5 + Vout © Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 4 / 4