TXLN960 TRACOPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

AC/DC Power Supply TXLN 960 Series, 960 Watt

  • Compact metal case with screw terminal block
  • Universal input 90-264 VAC
  • High efficiency up to 89%
  • Active PFC >0.95
  • Compliance to EN 61000-3-2
  • Short circuit, overvoltage and overload protection
  • IEC/EN/UL 62368-1 safety approvals
  • Remote On/Off and Remote Sense
  • Standard features: Power Good Signal, Load Sharing, 12 V Standby Output
  • 3 year product warranty IEC 62368-1UL 62368-1 The TXLN series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw ter- minal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TXLN 960-112 960 W 12 VDC (10.8 - 13.2 VDC) 80'000 mA 87 % TXLN 960-115 15 VDC (13.5 - 16.5 VDC) 64'000 mA 88 % TXLN 960-124 24 VDC (21.6 - 26.4 VDC) 40'000 mA 88 % TXLN 960-148 48 VDC (43.2 - 52.8 VDC) 20'000 mA 89 % www.tracopower.com March 16, 2023 Page 1 / 5

Input Voltage - AC Range Operational Range: 90 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 127 - 375 VDC (Designed for, no certification) Polarity: irrelevant Input Frequency Operational Range: 47 - 63 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 230 VAC 6'500 mA max. - Full Load & Vin = 115 VAC 10'500 mA max. Input Inrush Current - At 230 VAC 90 A max. - At 115 VAC 50 A max. Power Factor - At 230 VAC 0.95 min. (Active Power Factor Correction) - At 115 VAC 0.95 min. (Active Power Factor Correction) Input Protection T 12 A / 250 VAC (Internal Fuse) Recommended Input Fuse 12'000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Specifications Output Voltage Adjustment ±10% (By trim potentiometer) Output power must not exceed rated power! Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) 0.5% max. - Load Variation (0 - 100%) 1% max. Ripple and Noise (20 MHz Bandwidth) 12 VDC model: 150 mVp-p max. (w/ 0.1 µF || 47 µF) 15 VDC model: 150 mVp-p max. (w/ 0.1 µF || 47 µF) 24 VDC model: 200 mVp-p max. (w/ 0.1 µF || 47 µF) 48 VDC model: 250 mVp-p max. (w/ 0.1 µF || 47 µF) Minimum Load Not required Temperature Coefficient ±0.03 %/K max. Hold-up Time - At 230 VAC 14 ms min. - At 115 VAC 14 ms min. Start-up Time - At 230 VAC 2'000 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 105 - 135% of Iout max. Overvoltage Protection 115 - 140% of Vout nom. Load Share Function - Refer to application note www.tracopower.com/overview/txln960 Load Share Accuracy 10% Output Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/txln960 Protection Class Class I (Prepared): Connection to PE Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications EMI Emissions - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class D - Voltage Fluctuations & Flicker EN 61000-3-3 EMC Specifications TXLN 960 Series, 960 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 5

EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±4 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±2 kV, perf. criteria B L to PE: EN 61000-4-5, ±4 kV, perf. criteria B - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A 1 s: EN 61000-4-8, 300 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria C >95%, 0.5 periods, perf. criteria B >95%, 250 periods, perf. criteria C Relative Humidity 90% max. (non condensing) Temperature Ranges - Operating Temperature –20°C to +70°C - Storage Temperature –40°C to +85°C Power Derating - High Temperature 2.5 %/K above 50°C - Low Input Voltage Depending on model See application note: www.tracopower.com/overview/txln960 Over Temperature Protection Switch Off - Protection Mode 90°C min. / 95°C typ. / 100°C max. (Automatic recovery) Cooling System Forced air cooling (with internal fan) Fan Power Source - Characteristic Constant fan speed (continuous) - Output Voltage 12 VDC - Output Current 480 mA max. Standby Power Source - Output Voltage 12 VDC - Output Current 300 mA max. Remote Control - Voltage Controlled Remote See application note: www.tracopower.com/overview/txln960 Altitude During Operation 4'000 m max. (The max. ambient temperature decreases by 5 K / 1000 m when operated above 2000 m) Switching Frequency 55 - 65 kHz (PWM) Insulation System Reinforced Insulation Isolation Test Voltage - Input to Output, 60 s 3'000 VAC - Input to Case or PE, 60 s 1'800 VAC - Output to Case or PE, 60 s 500 VAC Isolation Resistance - Input to Output, 500 VDC 100 MΩ min. Isolation Capacitance - Input to Output, 100 kHz, 1 V 20'000 pF max. Leakage Current (at 264 VAC / 60Hz) - Earth Leakage Current 1500 µA max. Distance Through Isolation 6 mm Reliability - Calculated MTBF 84'100 h (MIL-HDBK-217F, ground benign) Housing Material Aluminum Housing Type Metal Case Mounting Type Chassis Mount Connection Type Screw Terminal Weight 2'500 g Power OK Signal Voltage source output - Power OK High level - Power Off Low level (Refers to 'PG' and 'GND' Pin) Status Indicator Indicated by green LED General Specifications TXLN 960 Series, 960 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 5

Sense Function (to be done) Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/txln960 Outline Dimensions TXLN 960 Series, 960 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 4 / 5 Vadj 2 1 CN3 CN3 CN11 CN11 CN1 CN1 4 3 6 5 8 7 6 5 4 321 7.5 110 7.5 2-M3-P0.5 1 2 3 13 20 30 220 210 12.5 M3-P0.5 M3-P0.5 61136 240 4-M3-P0.5 (Bottom) 125 220 8.520 34.5 M3-P0.5 M3-P0.5 16.5 16.5 2-M3-P0.5 275 LN -v -v -v +v +v +v Dimensions in mm Mounting screws Tolerances: Max. screw penetration depth: 3.0 0-8: ±0.2 Max. screw locked torque M3: 0.8 Nm 8-25: ±0.3 Max. screw locked torque M4: 1.6 Nm 25-80: ±0.5 80-250: ±0.8 Included in shipment: - 6x M3 mounting screw Input CN1 Pin Function

1 AC (L)

2 AC (N)

4 –Sense 5 –Remote 6 +Remote

7 Standby

8 GND

4-6 –Vout CN1: 3 pin, 10mm pitch with PC cover CN11: 6 pin, 11 mm pitch CN3 Housing Type: HRS DF11-8DP-2DSA CN3 Mating Housing: HRS DF11-8DS-2C CN3 Crimp Contact: HRS DF11-EP22SCB

Mounting Bracket (included) TXLN 960 Series, 960 Watt 16.8 17.5 10.0 5.0 5.6 12.5 5.0 7.5 4.0/multiply.case7.0 7.5 7.5 R1.0 7.5 15.0 R0.5 Ø4.2 15.0 Dimensions in mm Included in shipment: - 4x Mounting Bracket - 4x M4 mounting screw © Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 5 / 5