TXL230 TRACOPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
http://www.tracopower.com Page 1 of 4 AC/DC Enclosed Power Supply TXL 230 Series, 230 Watt Models
- Compact metal case with screw terminal block
- Universal input 85 - 264 Vac
- EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1
- Compliance to EN 61000-3-2
- Active power factor correction
- Short circuit and overvoltage protection
- International safety approvals
- 3 year product warranty The TRACOPOWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC stan - dards and the Low Voltage Directive (LVD). Order Code Power max. Output voltage nom. Output current max. Efficiency typ. TXL 230-12S 230 W 12 VDC 19.2 A 83 % TXL 230-24S 230 W 24 VDC 9.6 A 85 % TXL 230-48S 230 W 48 VDC 4.8 A 86 % Models C B Scheme UL 60950-1
TXL 230 Series, 230 Watt http://www.tracopower.com Page 2 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Input Specifications Input voltage range – nominal 100 – 240 VAC – AC range (universal input) 85 – 264 VAC – DC range 120 – 375 VDC (Designed for, no certification) Input frequency 47 – 63 Hz Input current at full load – at 100 VAC 3.2 A max. Input inrush current – at 115 VAC / 230 VAC 35 A max. / 70 A max. Power Factor Correction (PFC) PF > 0.95 Recommended circuit breaker (characteristic C or slow bow fuse) 10 A Output Specifications Output voltage adjustment range ±10 % Regulation – Input variation 1.0 % max. – Load variation (20 - 100%) 1.0 % max. Minimum load not required Temperature coefficient 0.02 %/K Start-up time 3 s max. Rise time 20 ms max. Hold-up time – at 230 VAC 20 ms min. Ripple and noise (20Mhz Bandwidth) 12 Vout model: 120 mVp-p typ. 24 & 48 Vout models: 200 mVp-p typ. – measured with external capacitors: 0.1 µF and 47 µF parallel capacitor Overload protection by current limitation 105 – 150 % of Iout max. Short circuit protection hiccup mode (automatic recovery) Overvoltage protection (Latch off, recovery after restart) 115 – 140 % of nominal Vout Capacitive load www.tracopower.com/products/txl-capload.pdf General Specifications Temperature ranges – Operating –20°C to +70°C (with derating) – Storage –40°C to +85°C Output power derating – Temperature 2.5 %/K above +50°C – Low input voltage 0.7 %/V below 100 VAC Cooling forced airflow cooling with DC fan Over Temperature Protection over 90°C thermal shutdown, auto. recovery Humidity (non condensing) 20 – 90 % rel. H max. Altitude during operation 2000 m Isolation voltage (60 sec.) – Input / Output 3000 VAC – Input / PE 1500 VAC – Output / PE 500 VAC Isolation resistance (at 500 VDC) 100 MOhm min. Leakage current (at 264 VAC/60Hz) 1.5 mA max. Remote Sense open or connected to the load (RS+, RS–) Remote on/off – Power On: 0 – 0.7 VDC – Power Off: 3 – 10 VDC – Off idle current 3 – 10 mA
TXL 230 Series, 230 Watt http://www.tracopower.com Page 3 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. General Specifications (continued) Switching frequency 65 kHz typ. (pulse width modulation) Reliability (calculated MTBF) > 215‘000 h Electromagnetic compatibility (EMC), emissions – Conducted input RI suppression EN 55022 class B, FCC Part 15 level B – Harmonic current emissions IEC / EN 61000-3-2, class D – Voltage flicker IEC / EN 61000-3-3 Electromagnets compatibility (EMC), immunity according EN 55024 – Electrostatic discharge ESD IEC / EN 61000-4-2, 4kV/8kV, perf. criteria A – RF field immunity IEC / EN 61000-4-3, 20V/m, perf. criteria A – Electrical fast transients/burst immunity IEC / EN 61000-4-4, ±2kV, perf. criteria A – Surge IEC / EN 61000-4-5, 1kV/2kV, perf. criteria A – Conducted RF IEC / EN 61000-4-6, 3 Vrms perf. criteria A – Magnetic field IEC / EN 61000-4-8, 3 A/m perf. criteria A – Voltage dip IEC / EN 61000-4-11 Safety standards UL 60950-1, IEC/EN 60950-1 Safety approvals – UL/cUL www.ul.com -> certifications -> File: e188913 – CB report www.tracopower.com/overview/txl Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf – RoHS RoHS directive 2011/65/EU Casing material aluminium (chassis and cover) Weight 0.88 kg
TXL 230 Series, 230 Watt www .tracopowe r.com © Copyright 2021 Traco Electronic AG Specifications can be changed without notice! Page 4 of 4 Rev. June 29, 2021 Outline Dimensions RC Remote Control On/Off: RC+/RC– On = 0 – 0.7 VDC, Off = 3 – 10 VDC RS Remote Sense: RS+/RS– Can be open or connected to the load under regard of polarity. Connector type: JS-1001R-XX Remote Connector 4x TXL-CMB chassis mount brackets included in shipment Order Code TXL-CMB Package contains 4 pcs brackets and screws Chassis Mount Brackets 17.5 5.6 15.0 16.8 7.5 7.5 15.0 5.012.5 Ø4.2 R0.5 7.5 7.5 5.0 10.0 4x7 R1.0 99 (3.9) (1.77) Vout L N 198 12 max. (0.47 max.) (7.8) 117 (4.61) 56 (0.98) 12.5 (0.49)(2.20) 11.5 (0.45) (0.83) (0.49) 12.5 176.5 (6.95) V adj. RC RS +--+ (2.56) (0.39) 168 (6.61) (2.48) 6 x M4 THD air flow (0.39) (1.10) 79 (3.11) 49.5 (1.95) 2 x M4 THD (bottom) 4 x M3 THD (bottom) Top View Dimensions in [mm], () = Inch Tolerances ±0.5 (±0.02)