http://www.tracopower.com Page 1 of 4 AC/DC Enclosed Power Supply TXL 100 Series, 100 Watt Models
- Compact metal case with screw terminal block
- Multiple output models with isolated outputs
- Universal input 85 – 264 Vac
- EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1
- Compliance to EN 61000-3-2
- Short circuit and overvoltage protection
- International safety approvals
- 3 year product warranty The TRACOPOWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC stan - dards and the Low Voltage Directive (LVD). Order Code Power Output voltage Output current max. Efficiency nom. Vout 1 Vout 2 Vout 3 Vout 1 Vout 2 Vout 3 typ. TXL 100-3.3S 76 W 3.3 VDC 23.0 A 74 % TXL 100-05S 100 W 5 VDC 20.0 A 78 % TXL 100-12S 102 W 12 VDC 8.5 A 83 % TXL 100-15S 105 W 15 VDC 7.0 A 84 % TXL 100-24S 103 W 24 VDC 4.3 A 84 % TXL 100-48S 110 W 48 VDC 2.3 A 86 % TXL 100-0512DI 1) 100 W +5 VDC +12 VDC 12.0 A 7.0 A 81 % TXL 100-0524DI 1) 100 W +5 VDC +24 VDC 12.0 A 3.5 A 82 % TXL 100-0521TI 1) 100 W +5 VDC +12 VDC –5 VDC 12.0 A 5.0 A 1.5 A 78 % TXL 100-0522TI 1) 100 W +5 VDC +12 VDC –12 VDC 12.0 A 5.0 A 1.5 A 78 % TXL 100-0533TI 1) 100 W +5 VDC +15 VDC –15 VDC 12.0 A 4.0 A 1.5 A 78 % TXL 100-0534TI 1) 100 W +5 VDC +12 VDC +24 VDC 12.0 A 4.0 A 2.0 A 78 % Models CB Scheme UL 60950-1 1) Total power should not exceed max. output power
TXL 100 Series, 100 Watt http://www.tracopower.com Page 2 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Input Specifications Input voltage range – nominal 100 – 240 VAC – AC range (universal input) 88 – 264 VAC – DC range 125 – 375 VDC (Designed for, no certification) Input frequency 47 – 63 Hz Input current at full load – at 100 VAC 2.8 A max. Input inrush current – at 115 VAC / 230 VAC 35 A max. / 70 A max. Zero load power consumption only single output models: 1.0 W max. (green mode function) Recommended circuit breaker (characteristic C or slow bow fuse) 10 A Output Specifications Output voltage adjustment range ±10 % (only Vout 1) Regulation – Input variation 1.0 % max. – Load variation (20 - 100%) main output: 2.0 % max. Vout 2, Vout 3: 5.0 % max. Minimum load single output models: not required dual / triple output models: Vout 1 requires 1.0 A Temperature coefficient 0.02 %/K Start-up time 1 s max. Rise time 20 ms max. Hold-up time – at 230 VAC 60 ms min. Ripple and noise – measured with external capacitors: 0.1 µF and 47 µF parallel capacitor (20Mhz Bandwidth) – Positive Vout 3.3 & 5 Vout: 70 mVp-p typ. 12 Vout: 120 mVp-p typ. 15 Vout: 150 mVp-p typ. 24 Vout: 240 mVp-p typ. 48 Vout: 250 mVp-p typ. – Negative Vout – 5 Vout: 100 mVp-p typ. – 12 Vout: 150 mVp-p typ. – 15 Vout: 200 mVp-p typ. Overload protection by current limitation 105 – 150 % of Iout max. Short circuit protection hiccup mode (automatic recovery) Overvoltage protection (Latch off, recovery after restart) 115 – 140 % of nominal Vout (only Vout 1) Capacitive load www.tracopower.com/products/txl-capload.pdf General Specifications Temperature ranges – Operating –20°C to +70°C (with derating) – Storage –40°C to +85°C Output power derating – Temperature 2.5 %/K above +45°C – Low input voltage 0.7 %/V below 100 VAC Cooling natural convection (20 lfm), no internal fan Humidity (non condensing) 20 – 90 % rel. H max. Altitude during operation 2000 m Isolation voltage (60 sec.) – Input / Output 3000 VAC – Input / PE 1500 VAC – Output / PE 500 VAC Isolation resistance (at 500 VDC) 100 MOhm min. Leakage current (at 264 VAC/60Hz) 1 mA max.
TXL 100 Series, 100 Watt http://www.tracopower.com Page 3 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. General Specifications (continued) Switching frequency 65 kHz typ. (pulse width modulation) Reliability (calculated MTBF) single output models: > 270‘000 h dual output models: > 260‘000 h dual output models: > 245‘000 h Electromagnetic compatibility (EMC), emissions – Conducted input RI suppression EN 55022 class B, FCC Part 15 level B – Harmonic current emissions IEC / EN 61000-3-2, class A – Voltage flicker IEC / EN 61000-3-3 (built-in PFC choke) Electromagnets compatibility (EMC), immunity according EN 55024 – Electrostatic discharge ESD IEC / EN 61000-4-2, 4kV/8kV, perf. criteria A – RF field immunity IEC / EN 61000-4-3, 20V/m, perf. criteria A – Electrical fast transients/burst immunity IEC / EN 61000-4-4, ±2kV, perf. criteria A – Surge IEC / EN 61000-4-5, 1kV/2kV, perf. criteria A – Conducted RF IEC / EN 61000-4-6, 3 Vrms perf. criteria A – Magnetic field IEC / EN 61000-4-8, 3 A/m perf. criteria A – Voltage dip IEC / EN 61000-4-11 Safety standards UL 60950-1, IEC/EN 60950-1 Safety approvals – UL/cUL www.ul.com -> certifications -> File: e188913 – CB report www.tracopower.com/overview/txl Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf – RoHS RoHS directive 2011/65/EU Connection single output models: 7 pole terminal pitch (9.5mm with plastic cover) dual / triple output models: 9 pole terminal pitch (7.62mm with plastic cover) Casing material nickel plated steel (cover), aluminium (chassis) Weight single output models: 0.72 kg dual / triple output models: 0.80 kg
TXL 100 Series, 100 Watt www .tracopowe r.com © Copyright 2021 Traco Electronic AG Specifications can be changed without notice! Page 4 of 4 Rev. June 29, 2021 Outline Dimensions Pin Single Dual Triple
1 AC L AC L AC L
2 AC N AC N AC N
3 PE PE PE
4 – Vout No con. + Vout 3 * 5 – Vout No con. – Vout 3 * 6 + Vout – Vout 1 – Vout 1 7 + Vout + Vout 1 + Vout 1 8 – – Vout 2 – Vout 2 9 – + Vout 2 + Vout 2 Screw TerminalDimensions in [mm], () = Inch Tolerances ±0.5 (±0.02) * Opposite polarity for TXL 100-0534TI 198 10 max. (0.39 max.) (7.80) (0.35) 80 (3.15) 120 (4.72) 4 x M3 THD (bottom) Dual & Triple output models Single output 158 (6.22) 20 (0.79) (0.71) (0.75) (0.39) (1.50) (3.74) 16.5 (0.45) Top view 3 x M3 THD