TXL050-060 TRACOPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
http://www.tracopower.com Page 1 of 4 AC/DC Enclosed Power Supply TXL 050/060 Series, 50/60 Watt
- Compact metal case with screw terminal block
- Universal input 85 - 264 Vac
- EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1
- Compliance to EN 61000-3-2
- Short circuit and overvoltage protection
- International safety approvals
- 3 year product warranty The TRACO POWER TXL series is a family of encased power supplies designed for a wide range of cost critical applications. With a low profile metal case and screw terminal block connection, they are easy to install in any equipment. These power supplies have universal input and comply with European EMC stan - dards and the Low Voltage Directive (LVD). Order Code Power max. Output voltage nom. Output current max. Efficiency typ. TXL 050-05S 50 W 5 VDC 10.0 A 78 % TXL 060-12S 60 W 12 VDC 5.0 A 81 % TXL 060-15S 60 W 15 VDC 4.0 A 83 % TXL 060-24S 60 W 24 VDC 2.5 A 84 % Models UL 60950-1 UL 62368-1 IEC 60950-1 IEC 62368-1
TXL 050/060 Series, 50/60 Watt http://www.tracopower.com Page 2 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Input Specifications Input voltage range – nominal 100 – 240 VAC – AC range (universal input) 88 – 264 VAC – DC range 125 – 375 VDC (Designed for, no certification) Input frequency 47 – 63 Hz Input current at full load – at 100 VAC 1.6 A max. Input inrush current – at 115 VAC / 230 VAC 30 A max. / 50 A max. Zero load power consumption 0.5 W max. (green mode function) Recommended circuit breaker (characteristic C or slow bow fuse) 5 A Output Specifications Output voltage adjustment range ±10 % Regulation – Input variation 1.0 % max. – Load variation (20 - 100%) 1.0 % max. Minimum load not required Temperature coefficient 0.02 %/K Start-up time 1 s max. Rise time 30 ms max. Hold-up time – at 230 VAC 60 ms min. Ripple and noise (20Mhz Bandwidth) 5 Vout model: 70 mVp-p typ. 12 Vout model: 120 mVp-p typ. 15 & 24 Vout models: 150 mVp-p typ. – measured with external capacitors: 0.1 µF and 47 µF parallel capacitor Overload protection by current limitation 105 – 150 % of Iout max. Short circuit protection hiccup mode (automatic recovery) Overvoltage protection (Latch off, recovery after restart) 115 – 140 % of nominal Vout Capacitive load www.tracopower.com/products/txl-capload.pdf General Specifications Temperature ranges – Operating –20°C to +70°C (with derating) – Storage –40°C to +85°C Output power derating – Temperature 2.5 %/K above +50°C – Low input voltage 0.8 %/V below 100 VAC Cooling natural convection (20 lfm), no internal fan Humidity (non condensing) 20 – 90 % rel. H max. Altitude during operation 2000 m Isolation voltage (60 sec.) – Input / Output 3000 VAC – Input / PE 1500 VAC – Output / PE 500 VAC Isolation resistance (at 500 VDC) 100 MOhm min. Leakage current (at 264 VAC/60Hz) 0.75 mA max.
TXL 050/060 Series, 50/60 Watt http://www.tracopower.com Page 3 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. General Specifications (continued) Switching frequency 65 kHz typ. (pulse width modulation) Reliability (calculated MTBF) > 335‘000 h Electromagnetic compatibility (EMC), emissions – Conducted input RI suppression EN 55032 class B, FCC Part 15 level B – Harmonic current emissions IEC/EN 61000-3-2, class A – Voltage flicker IEC/EN 61000-3-3 Electromagnets compatibility (EMC), immunity according EN 55024 & EN 55035 – Electrostatic discharge ESD IEC/EN 61000-4-2, 4 kV / 8 kV, perf. criteria A – RF field immunity IEC/EN 61000-4-3, 3 V/m, perf. criteria A – Electrical fast transients/burst immunity IEC/EN 61000-4-4, ±2 kV, perf. criteria A – Surge IEC/EN 61000-4-5, 1 kV / 2 kV, perf. criteria A – Conducted RF IEC/EN 61000-4-6, 3 Vrms perf. criteria A – Magnetic field IEC/EN 61000-4-8, 3 A/m perf. criteria A – Voltage dip IEC/EN 61000-4-1 1 >95 %, perf. criteria A, 0.5 periods 30 %, perf. criteria A, 25 periods >95 % perf. criteria B, 250 periods Safety standards UL 60950-1, IEC/EN 60950-1 UL 62368-1, IEC/EN 62368-1 Safety approvals – UL/cUL www.ul.com -> certifications -> File: e188913 – CB report www.tracopower.com/overview/txl Environmental compliance – Reach www.tracopower.com/products/reach-declaration.pdf – RoHS RoHS directive 2011/65/EU Connection 5 pole terminal pitch (9.5mm with plastic cover) Casing material nickel plated steel (cover), aluminium (chassis) Weight 0.34 kg
TXL 050/060 Series, 50/60 Watt www .tracopowe r.com © Copyright 2023 Traco Electronic AG Specifications can be changed without notice! Page 4 of 4 Rev. March 21, 2023 Outline Dimensions Pin Single
1 AC L
2 AC N
4 – Vout 5 + Vout Screw Terminal 99 12 (0.47) (3.90) 23.555 (2.17) (0.93) 45 (1.77) 774 (2.91) (0.28) 17.5 (0.69) (1.38) (3.23) 2 x M3 THD (bottom)Top view 2x M3 THD Dimensions in [mm], () = Inch Tolerances ±0.5 (±0.02)