TXH360 TRACOPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

AC/DC Power Supply TXH 360 Series, 360 Watt End of life

  • Compact enclosed power supplies
  • Screw terminal block
  • Very high efficiency up to 93 %
  • Universal input 90 – 264 VAC
  • Adjustable output voltage
  • EMI/EMC compliance with EN 61000-6-3 and EN 61000-6-1
  • Complience to EN 61000-3-2 (PFC)
  • Short circuit and over voltage protection
  • 3-year product warranty IEC 60950-1UL 60950-1 The TXH series is a family of power supplies in metal enclosure, designed for a wide range of cost critical applications. The very high efficiency of up to 93% admits of a compact design with free air convection coouling for the 120 and 240 Watt models. The units are equiped with screw terminal blocks and are easy to install in any equipment. These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). Models Order Code Output Power max. Output Voltage nom. (adjustable) Output Current max. Efficiency typ. TXH 360-112 * 360 W 12 VDC (10.8 - 13.2 VDC) 30'000 mA 89 % TXH 360-124 * 24 VDC (21.6 - 26.4 VDC) 15'000 mA 91 % TXH 360-148 * 48 VDC (44.0 - 51.0 VDC) 7'500 mA 93 % Note * End of life www.tracopower.com October 21, 2020 Page 1 / 4

Input Voltage - AC Range 90 - 264 VAC (Full Range) - DC Range 120 - 370 VDC (Designed for, no certification) Input Frequency 47 - 63 Hz Input Current - Full Load & Vin = 230 VAC 2'000 mA max. - Full Load & Vin = 115 VAC 4'000 mA max. Power Consumption - At no load 2'500 mW max. Input Inrush Current - At 230 VAC 60 A max. - At 115 VAC 30 A max. Power Factor - At 230 VAC 0.93 min. (Active Power Factor Correction) - At 115 VAC 0.98 min. (Active Power Factor Correction) Input Protection T 6.3 A / 250 VAC Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Specifications Output Voltage Adjustment 12 VDC model: 10.8 - 13.2 VDC 24 VDC model: 21.6 - 26.4 VDC 48 VDC model: 44.0 - 51.0 VDC (By trim potentiometer) Output power must not exceed rated power! Voltage Set Accuracy ±2% max. Regulation - Input Variation (Vmin - Vmax) 1% max. - Load Variation (0 - 100%) 1% max. Ripple and Noise (20 MHz Bandwidth) 12 VDC model: 150 mVp-p max. (w/ 0.1 µF // 47 µF) 24 VDC model: 200 mVp-p max. (w/ 0.1 µF // 47 µF) 48 VDC model: 200 mVp-p max. (w/ 0.1 µF // 47 µF) Capacitive Load 12 VDC model: 85'000 µF max. 24 VDC model: 48'000 µF max. 48 VDC model: 13'000 µF max. Minimum Load 1 % of Iout max. Temperature Coefficient ±0.03 %/K max. Hold-up Time - At 230 VAC 12 ms min. - At 115 VAC 12 ms min. Start-up Time - At 230 VAC 500 ms max. - At 115 VAC 500 ms max. Short Circuit Protection Automatic recovery Overload Protection Indefinite Mode Output Current Limitation 110 - 160% of Iout max. Overvoltage Protection 105 - 145% of Vout nom. (By Zener diode) Transient Response - Response Deviation 2% max. (75% to 100% Load Step) - Response Time 500 µs typ. (75% to 100% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment EN 60950-1 IEC 60950-1 UL 60950-1 - Certification Documents www.tracopower.com/overview/txh360 Protection Class Class I (Prepared): Connection to PE Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications TXH 360 Series, 360 Watt All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated. www.tracopower.com October 21, 2020 Page 2 / 4

EMI Emissions EN 61000-6-3 (Generic Residential) - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class A - Voltage Fluctuations & Flicker EN 61000-3-3 EMS Immunity EN 55024 (IT Equipment) EN 61000-6-1 (Generic Residential) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±4 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 3 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±1 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A L to PE: EN 61000-4-5, ±2 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 3 Vrms, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 250 periods, perf. criteria B EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –25°C to +70°C - Storage Temperature –25°C to +85°C Power Derating - High Temperature 2.5 %/K above 50°C - Low Input Voltage 1 %/V below 100 VAC Cooling System Forced air cooling (with internal fan) Fan Power Source - Characteristic Variable fan speed (temperature regulated) Altitude During Operation 2'000 m max. Switching Frequency 65 - 220 kHz (PWM) 75 kHz typ. (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 259 VAC Isolation Test Voltage - Input to Output, 60 s 3'000 VAC - Input to Case or PE, 60 s 1'500 VAC - Output to Case or PE, 60 s 500 VAC Creepage - Input to Output 5.2 mm min. Clearance - Input to Output 5.2 mm min. Leakage Current - Earth Leakage Current 600 µA max. - Touch Current 300 µA max. Reliability - Calculated MTBF 120'000 h (MIL-HDBK-217F, ground benign) Environment - Vibration 2 g, 3 axis, 60 min, 10-500 Hz, 10 min/cycle Connection Type Screw Terminal Weight 746 g Environmental Compliance - Reach www.tracopower.com/info/reach-declaration.pdf - RoHS www.tracopower.com/info/rohs-declaration.pdf General Specifications Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/txh360 TXH 360 Series, 360 Watt All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated. www.tracopower.com October 21, 2020 Page 3 / 4

TXH 360 Series, 360 Watt +Vout –Vout L N PE Dimensions in mm Tolerances: ±0.5 mm Pin tolerances: ±0.1 mm Pin Connections Pin Function 1 PE

2 AC IN (N)

3 AC IN (L)

7-9 –Vout © Copyright 2020 Traco Electronic AG Specifications can be changed without notice. www.tracopower.com Rev. October 21, 2020 Page 4 / 4