AC/DC Power Supply TXH 060 Series, 60 Watt
- Enclosed power supplies with screw terminal block
- Universal input range 90 to 264 VAC
- Ready to meet ErP directive, < 0.3 W no load power consumption
- Adjustable output voltage
- 4242 VDC I/O-isolation
- High efficiency up to 88%
- Operating temperature range: –30°C to +70°C max.
- Short circuit and over voltage protection IEC 62368-1UL 62368-1 The TXH 060 series is a family of power supplies in metal enclosure, designed for a wide range of cost critical applications. The high efficiency of up to 88% is achieved through an innovative design for free air convection cooling. This design also qualifies the power supply to meet the ErP directive ( < 0.3 W no load power consumption). The units are equiped with screw terminal blocks and are easy to install in any equipment. These power supplies have universal input and comply with European EMC standards and the Low Voltage Directive (LVD). Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TXH 060-105 50 W 5 VDC (4.8 - 5.3 VDC) 10'000 mA 81 % TXH 060-112 60 W 12 VDC (11.4 - 12.6 VDC) 5'000 mA 87 % TXH 060-115 15 VDC (14.3 - 15.8 VDC) 4'000 mA 87 % TXH 060-124 24 VDC (22.8 - 25.2 VDC) 2'500 mA 88 % TXH 060-148 48 VDC (45.6 - 50.4 VDC) 1'250 mA 88 % www.tracopower.com March 16, 2023 Page 1 / 4
Input Voltage - AC Range Operational Range: 90 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 120 - 370 VDC (Designed for, no certification) Polarity: +DC: L / –DC: N Input Frequency Operational Range: 47 - 440 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 230 VAC 1'000 mA max. - Full Load & Vin = 115 VAC 2'000 mA max. Power Consumption - No load & Vin = 230 VAC 300 mW max. (Ready to meet ErP directive) - No load & Vin = 115 VAC 300 mW max. Input Inrush Current - At 230 VAC 70 A max. - At 115 VAC 35 A max. (An external Thermistor has to be integreated in the circuit at the converter input L. Thermistor recommendation: 10R / 15z) Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Specifications Output Voltage Adjustment ±5% (By trim potentiometer) Output power must not exceed rated power! Voltage Set Accuracy ±2% max. Regulation - Input Variation (Vmin - Vmax) 1% max. - Load Variation (0 - 100%) 1% max. Ripple and Noise (20 MHz Bandwidth) 5 VDC model: 75 mVp-p max. (w/ 0.1 µF || 47 µF) 12 VDC model: 100 mVp-p max. (w/ 0.1 µF || 47 µF) 15 VDC model: 125 mVp-p max. (w/ 0.1 µF || 47 µF) 24 VDC model: 150 mVp-p max. (w/ 0.1 µF || 47 µF) 48 VDC model: 200 mVp-p max. (w/ 0.1 µF || 47 µF) Capacitive Load 5 VDC model: 10'000 µF max. 12 VDC model: 5'000 µF max. 15 VDC model: 4'000 µF max. 24 VDC model: 2'000 µF max. 48 VDC model: 1'000 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Hold-up Time - At 230 VAC 55 ms min. - At 115 VAC 10 ms min. Start-up Time - At 230 VAC 400 ms max. - At 115 VAC 500 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 115 - 160% of Iout max. Overvoltage Protection 105 - 145% of Vout nom. (By Zener diode) Transient Response - Response Deviation 2% max. (75% to 100% Load Step) - Response Time 500 µs typ. (75% to 100% Load Step) Output Specifications TXH 060 Series, 60 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 4
Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/txh060 Protection Class Class I (Prepared): Connection to PE Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications EMI Emissions - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class B - Voltage Fluctuations & Flicker EN 61000-3-3 EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±4 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±2 kV, perf. criteria A L to PE: EN 61000-4-5, ±2 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 250 periods, perf. criteria C EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –30°C to +70°C - Storage Temperature –50°C to +85°C Power Derating - High Temperature Depending on model - Low Input Voltage 2 %/V below 100 VAC See application note: www.tracopower.com/overview/txh060 Cooling System Natural convection (20 LFM) Altitude During Operation 3'100 m max. Switching Frequency 60 - 70 kHz (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 305 VAC Isolation Test Voltage - Input to Output, 60 s 3'000 VAC - Input to Case or PE, 60 s 1'500 VAC - Output to Case or PE, 60 s 500 VAC Creepage - Input to Output 5 mm min. Clearance - Input to Output 4 mm min. Leakage Current - Earth Leakage Current 1000 µA max. - Touch Current 750 µA max. Reliability - Calculated MTBF 130'000 h (MIL-HDBK-217F, ground benign) Environment - Vibration 2 g, 3 axis, 60 min, 10-500 Hz, 10 min/cycle Housing Type Metal Case Mounting Type Chassis Mount General Specifications TXH 060 Series, 60 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 4
Connection Type Screw Terminal Weight 220 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/txh060 Blockdiagram Outline Dimensions TXH 060 Series, 60 Watt +Vout –Vout L N PE 83.50 (3.287) 60.00 (2.362) All dimensions in mm (inch) Tolerances: ±0.5 ( ±0.02 ) Pin tolerances: ±0.1 (±0.004) Screws A: For mounting on DIN rail Screws B: Four mounting on PCB/chassis only Max. screw torque: 3 ±0.5 kgfcm Max. screw penetration: 2.0 (0.08) 7-M3X0.5 30.50 (1.201) 24.00 (0.945) 23.50 (0.925) 14.60 (0.575) 17.85 (0.703) 12.00 (0.472) 14.45 (0.569) 13.00 (0.512) 70.00 (2.756) 2.70 (0.106) 9.45 (0.372) 3-M3X0.5 38.00 (1.496) 9.00 (0.354) 59.70 (2.350) Pin 3 = Case B B B B A A A Voltage Adj. 88.90 (3.500) Pin Connections Pin Function
1 AC IN (N)
2 AC IN (L)
5 –Vout © Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 4 / 4