www.tracopower.com Page 1 of 9 Industrial Power Supplies TSPC Series, 50–480 Watt u Rugged metal case for harsh industrial environments u Industrial operating temperature range: –25°C to +70°C u Overload and and overtemperature protection u Power boost up to 120 % u Power-Good signal u Shock and vibration proof u International safety approval package u ATEX certification for hazardous locations u Decoupling module for redundant operation (optional) u Wall mounting (opt.) u 3-year product warranty The TSPC series are high performance DIN-rail mount power supplies for harsh indus - trial environments. The design is based on the popular TRACOPOWER TSP series but with reduced electrical features to make these power supplies an easy to install and cost efficient but reliable solution for basic applications. Excellent electrical specifications and high immunity against electrical disturbances makes these compact modules the best choice for reliable industrial systems and ma - chines. For system applications all models provide a Power-Good signal. The TSPC series power supplies complies with the latest safety and EMC standards for industrial environments and include ATEX EN 60079 certification for applications in hazardous locations. Order code Output power nominal Output voltage nominal Output current nominal TSPC 050-1 1 2 50 W 1 2 VDC 4.0 A TSPC 050-1 24HL* 50 W 24 VDC 2. 1 A TSPC 050-1 24 50 W 24 VDC 2. 1 A TSPC 080-1 1 2 80 W 1 2 VDC 6.6 A TSPC 080-1 24 80 W 24 VDC 3.3 A TSPC 1 20-1 24 1 20 W 24 VDC 5.0 A TSPC 1 20-148 1 20 W 48 VDC 2.5 A TSPC 240-1 24 240 W 24 VDC 10 A TSPC 240-148 240 W 48 VDC 5.0 A TSPC 480-1 24 480 W 24 VDC 20 A TSPC 480-148 480 W 48 VDC 10 A Models CB Scheme NK AA EMC LVD IEC 60950-1 UL 60950-1 UL 508 ATEX II3GEN 60950-1 EN 61558 EN 60204 * Additionally complies with UL hazloc

www.tracopower.com Page 2 of 9 Industrial Power Supplies TSPC Series 50–480 Watt Input Specifications Input voltage – nominal ranges TSPC 050 100 – 240 VAC universal input other models 100 – 120 / 220 – 240 VAC by selection switch – effective ranges TSPC 050 85 – 264 VAC universal input other models 85 – 132 / 187 – 264 VAC by selection switch – output power derating at input <100 VAC 3.3 %/V Input voltage frequency 47 – 63 Hz Harmonic limits EN 61000-3-2 Holdup time 10 ms min. Inrush current 40 A Recommended circuit breaker, – TSPC 080/120 6.0 – 16.0 A characteristic C – TSPC 240 10.0 – 16.0 A or fuse, slow blow type – TSPC 480 16.0 – 25.0 A Efficiency 85 – 93 % Output Specifications Output voltage adj. range 12 VDC models: 12 – 14 VDC output power derating above 12 VDC : 10 %/V

24 VDC models: 24 – 28 VDC

output power derating above 24 VDC : 5 %/V

48 VDC models: 48 – 56 VDC

output power derating above 48 VDC : 2.5 %/V Boost output current 120 % (at 24 VDC output voltage) continuous at <+50°C ambient temperature – power derating above 50°C ambient 2 %/°C – power derating at input <1 15 VAC 1.3 %/V – power derating at input <220 VAC 0.6 %/V (at upper input voltage range) Regulation – Input variation 1 % max. – Load variation (0–100 %) 1 % max. Ripple and Noise (20MHz bandwidth) 100 mVp-p typ. (200 mVp-p max.) Overload protection 130 % min. (of Iout nom., constant current) Short circuit current 90 % of Iout nom. (typ.), foldback Output overvoltage protection 12 VDC models: 25 V max. 24 VDC models: 40 V max. (TSPC 120, TSPC 240, TSPC 480) 45 V max. (TSPC 050, TSPC 080) 48 VDC models: 60 V max. Overtemperature protection switch off at overtemperature, automatic restart Power back immunity 12 VDC models: 16 V (18 V for 1 s)

24 VDC models: 35 V (40 V for 1 s)

48 VDC models: 63 V (65 V for 1 s)

Power OK signal – trigger threshold 12 VDC models: 10.0 – 11.5 V 24 VDC models: 21.0 – 22.5 V 48 VDC models: 42.0 – 45.0 V – output signal 12 VDC models: open collector 20 mA max. 24 VDC models: open collector 10 mA max. 48 VDC models: open collector 5 mA max. Active high: Connected to Vout in normal operation, high resistance at failure Max. capacitive load unlimited General Specifications Temperature range – Operating –25°C to +70°C max. (with derating) – Output current derating 2.5 %/°C above 60°C – Storage –40°C to +85°C Cooling convection cooling, no internal fan Humidity (non condensing) 95 % rel. H max.

www.tracopower.com Page 3 of 9 Industrial Power Supplies TSPC Series 50–480 Watt General Specifications Pollution degree 2 Altitude during operation 2‘000 m max. Temperature coefficient 0.02 %/K Reliability, calculated MTBF at +25°C acc. to IEC 61709 – TSPC 080 2.4 Mio. h – TSPC 120 2.5 Mio. h – TSPC 240 1.7 Mio. h – TSPC 480 1.4 Mio. h Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508 Safety standards – Information technology equipment IEC/EN 60950-1, UL 60950-1, CSA 22.2 No 60950-1-07 – Measurement, Control & Laboratory IEC/EN 61010-1, IEC/EN 61010-2-201 – Industrial control equipment UL 508, CSA-C22.2 No.107 – Electrical equipment for machines EN 60204-1 – Electronic equipment for power installation EN 50178 – Safety of transformers EN 61558-2-6, EN 61558-2-16 – Control equipment for hazardous location EN 60079-15 II3G EX nA IIC T4 – ATEX (for IP 54 enclosure) certificate no. EPS 10 ATEX 1 269 X – UL hazloc (TSPC 050-124HL only) UL 121201 Class I; Div 2; Groups A,B,C & D; T4 – Certification documents www.tracopower.com/ overview/tspc Class of protection safety class I (IEC 536) Degree of protection IP 20 (IEC/EN 60529) Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3 – Conducted RI suppression on input EN 55011 class B, EN 55022 class B, – Radiated RI suppression EN 55011 class B, EN 55022 class B, Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3 – Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kV / 8 kV criteria B – Radiated RF field immunity IEC/EN 61000-4-3 10 V / m criteria A – Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kV criteria B – Surge immunity IEC/EN 61000-4-5 1 kV / 2 kV criteria B – Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V criteria A – Power frequency field immunity IEC/EN 61000-4-8 30 A / m criteria A – Mains voltage dips and interruptions IEC/EN 61000-4-11 criteria B/C Environment – Vibration acc. IEC 68-2-6; 3 axis, sine sweep, 10 – 55 Hz, 1 g, 1 oct/min – Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms Enclosure material aluminium (chassis) / stainless steel (cover) Mounting – DIN-rail mounting for DIN-rails as per EN 50022-35x15/7 .5 (snap-on with self-locking spring) – Wall mounting (option) with wall mounting bracket - see page 12 Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf – RoHS Ro H S d i r e c t i ve 2011/6 5/E U Connection – Input / Output screw terminals – Power Good signal (mating connector) Phoenix contact MC 1,5/2-ST-3,5 (not included) Installation instructions www.tracopower.com/ overview/tspc Accessories (optional) Decoupling module for redundant operation see: www.tracopower.com/products/tspc-dcm.pdf Wall mounting brackets: see last page

www.tracopower.com Page 4 of 9 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Industrial Power Supplies TSPC Series 50–480 Watt Outline Dimensions TSPC 050-1 12 TSPC 050-124(HL*) DC-OK GND (DC-OK) 110.0 (4.33) 35.5 (1.45) O/P Adjust DC ON *TSPC 050-124HL contains mating plug on DC-OK connector fitted with cable tie which enlarges height of product 9mm max.

www.tracopower.com Page 5 of 9 Outline Dimensions TSPC 080-1 12 TSPC 080-124 Industrial Power Supplies TSPC Series 50–480 Watt DC-OK GND (DC-OK) Input Voltage Range Select O/P Adjust DC ON NL -- ++ 230 110.0 (4.33) 40.0 (1.57) Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) Weight: 400 g (1 4. 1 oz)

www.tracopower.com Page 6 of 9 Industrial Power Supplies TSPC Series 50–480 Watt Outline Dimensions TSPC 120-124 TSPC 120-148 O/P Adjust DC ON -- ++ NL 46.0 (1.81) 110.0 (4.33) Input Voltage Range Select DC-OK GND (DC-OK) 230 Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) Weight: 500 g (1 7 .7 oz)

www.tracopower.com Page 7 of 9 Industrial Power Supplies TSPC Series 50–480 Watt Outline Dimensions TSPC 240-124 TSPC 240-148 Input Voltage Range Select -- ++ O/P Adjust DC ON NL DC-OK GND (DC-OK) 110.0 (4.33) 230 Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) Weight: 750 g (26.5 oz)

www.tracopower.com Page 8 of 9 DC-OK GND (DC-OK) Input Voltage Range Select 110.0 (4.33) 230 100.0 (3.94) -- ++ O/P Adjust DC ON NL Outline Dimensions TSPC 480-124 TSPC 480-148 Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02) Weight: 1 950 g (68.8 oz) Industrial Power Supplies TSPC Series 50–480 Watt

Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www .tracopower.com Page 9 of 9 order code for models content of kit TSP-WMK03 TSP-WMK02 TSPC 080, TSPC 1 20, TSPC 240, TSP-DCM600 TSPC 480 1 bracket 2 brackets TSP–WMK Wall Mounting Bracket TSP-WMK03 TSP-WMK02 Rev. February 28, 2023 Dimensions: [mm] ( ) = Inch 15.0 (0.59) 7.0 (0.28) 15.0 (0.59) 46.0 (1.81) 33.0 (1.30) 25 (0.98) 50.0 (1.97) 2x R 2.15 (0.085) 4 x positioning holes 2.0 (0.08) Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) Material: 2 mm Mild Steel Tolerance: ±0.1mm (± 0.004) 55.0 (2.16) 150 (5.91) TSPC 080 TSPC 120 TSPC 240 TSPC 480 2.0 (0.08) 30.0 (1.18) 15.0 (0.59) ø 4.3 (0.17) 7.0 (0.28) 55.0 (2.16) ø 4.25 (0.17) 2.0 (0.08) 2.0 (0.08) R 2.12 (0.083) R 2.12 (0.083) 85.0 (3.35) 42.5 (1.67) 74.0 (2.91) 37.0 (1.45) 4 x positioning holes Industrial Power Supplies TSPC Series 50–480 Watt Dimensions in [mm], ( ) = Inch Tolerances: ±0.5 mm (±0.02)