DC/DC Converter TRN 3SM Series, 3 Watt
- Compact SMD package 11,9 x 11,3 x 8,0 mm
- Fully regulated outputs
- Input Voltage range
- I/O-isolation 1‘600 VDC
- Operating temperature range –40°C to +85°C
- Short circuit protection
- Designed to meet UL 62368-1 (UL 60950-1)
- 3-year product warranty The TRN 3SM Series comprises 3 Watt fully regulated, high performance DC/DC converters. They come in a compact cubical package of only 1.07 cm³. Full load operation is reliable up tp 65°C environment temperature. With 1’600 VDC I/O-isolation voltage, and short current protection they cover a wide range of application when space is limited. The input of the converters is designed for a wide voltage range (2:1) and minimum load is not required. The functional I/O-isolation system is designed to meet IEC/EN 62368-1 with a test voltage (60 s) of 1600 VDC. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TRN 3-0510SM 4.5 - 13.2 VDC (9 VDC nom.)
3.3 VDC 700 mA 75 %
TRN 3-0511SM 5 VDC 600 mA 78 % TRN 3-0512SM 12 VDC 250 mA 82 % TRN 3-0513SM 15 VDC 200 mA 80 % TRN 3-0515SM 24 VDC 125 mA 80 % TRN 3-0521SM +5 VDC 300 mA –5 VDC 300 mA 77 % TRN 3-0522SM +12 VDC 125 mA –12 VDC 125 mA 80 % TRN 3-0523SM +15 VDC 100 mA –15 VDC 100 mA 80 % TRN 3-1210SM 9 - 18 VDC (12 VDC nom.)
3.3 VDC 700 mA 76 %
TRN 3-1211SM 5 VDC 600 mA 79 % TRN 3-1212SM 12 VDC 250 mA 84 % TRN 3-1213SM 15 VDC 200 mA 83 % TRN 3-1215SM 24 VDC 125 mA 82 % TRN 3-1221SM +5 VDC 300 mA –5 VDC 300 mA 78 % TRN 3-1222SM +12 VDC 125 mA –12 VDC 125 mA 82 % TRN 3-1223SM +15 VDC 100 mA –15 VDC 100 mA 81 % TRN 3-2410SM 18 - 36 VDC (24 VDC nom.) TRN 3-2411SM 5 VDC 600 mA 78 % TRN 3-2412SM 12 VDC 250 mA 84 % TRN 3-2413SM 15 VDC 200 mA 84 % TRN 3-2415SM 24 VDC 125 mA 83 % TRN 3-2421SM +5 VDC 300 mA –5 VDC 300 mA 79 % TRN 3-2422SM +12 VDC 125 mA –12 VDC 125 mA 83 % TRN 3-2423SM +15 VDC 100 mA –15 VDC 100 mA 82 % TRN 3-4810SM 36 - 75 VDC (48 VDC nom.) TRN 3-4811SM 5 VDC 600 mA 79 % TRN 3-4812SM 12 VDC 250 mA 83 % TRN 3-4813SM 15 VDC 200 mA 83 % TRN 3-4815SM 24 VDC 125 mA 82 % TRN 3-4821SM +5 VDC 300 mA –5 VDC 300 mA 77 % TRN 3-4822SM +12 VDC 125 mA –12 VDC 125 mA 82 % TRN 3-4823SM +15 VDC 100 mA –15 VDC 100 mA 80 % www.tracopower.com November 30, 2022 Page 1 / 4
Input Current - At no load 9 Vin models: 75 mA typ. 12 Vin models: 40 mA typ. 24 Vin models: 20 mA typ. 48 Vin models: 12 mA typ. Surge Voltage 9 Vin models: 15 VDC max. (1 s max.) 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Reflected Ripple Current 9 Vin models: 100 mAp-p typ. 12 Vin models: 75 mAp-p typ. 24 Vin models: 75 mAp-p typ. 48 Vin models: 50 mAp-p typ. Recommended Input Fuse 9 Vin models: 1'600 mA (slow blow)
12 Vin models: 800 mA (slow blow)
24 Vin models: 500 mA (slow blow)
48 Vin models: 315 mA (slow blow)
(The need of an external fuse has to be assessed in the final application.) Input Filter Internal Capacitor Input Specifications Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.2% max. dual output models: 0.2% max. - Load Variation (0 - 100%) single output models: 1% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Cross Regulation (25% / 100% asym. load) dual output models: 5% max. Ripple and Noise - 20 MHz Bandwidth 50 mVp-p typ. Capacitive Load - single output 3.3 Vout models: 4'400 µF max. 5 Vout models: 2'200 µF max. 12 Vout models: 1'000 µF max. 15 Vout models: 820 µF max. 24 Vout models: 330 µF max. - dual output 5 / -5 Vout models: 1'200 / 1'200 µF max. 12 / -12 Vout models: 520 / 520 µF max. 15 / -15 Vout models: 440 / 440 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Start-up Time 5 ms typ. / 15 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 180% typ. of Iout max. Transient Response - Response Deviation 3% typ. (25% Load Step) - Response Time 500 µs typ. (25% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment Designed for EN 62368-1 (no certification) Safety Specifications TRN 3SM Series, 3 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 4
EMI Emissions - Conducted Emissions EN 55032 class A (with external filter) EN 55032 class B (with external filter) - Radiated Emissions EN 55032 class A (with external filter) EN 55032 class B (with external filter) External filter proposal: www.tracopower.com/overview/trn3sm EMS Immunity EN 55024 (IT Equipment) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±1 kV, perf. criteria A Ext. input component: Nippon chemi-con KY 220 µF/ 100 V - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A 1 s: EN 61000-4-8, 1000 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +85°C - Case Temperature +105°C max. - Storage Temperature –55°C to +125°C Power Derating - High Temperature 2.5 %/K above 65°C See application note: www.tracopower.com/overview/trn3sm Cooling System Natural convection (20 LFM) Switching Frequency 100 kHz min. (PFM) Insulation System Functional Insulation Isolation Test Voltage - Input to Output, 60 s 1'600 VDC Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. Isolation Capacitance - Input to Output, 100 kHz, 1 V 75 pF max. Reliability - Calculated MTBF 4'400'000 h (MIL-HDBK-217F, ground benign) Moisture Sensitivity (MSL) Level 2 (J-STD-033C) Washing Process Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf Environment - Vibration MIL-STD-810F - Thermal Shock MIL-STD-810F Housing Material Non-conductive Plastic (UL 94 V-0 rated) Potting Material Epoxy (UL 94 V-0 rated) Pin Material Copper Pin Foundation Plating Nickel (0.3 - 0.9 µm) Pin Surface Plating Tin (5 - 6 µm), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type SMD (Surface-Mount Device) Footprint Type SMD10 Soldering Profile Reflow Soldering (J-STD-020E) Weight 2.1 g General Specifications TRN 3SM Series, 3 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 4
Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/trn3sm Outline Dimensions Recommended Solder Pad Layout TRN 3SM Series, 3 Watt 0-10° 8.0 (0.31) 0.20 7.6 (0.3) 0.5 (0.02) 1.2 (0.05) bottom view 11.3 (0.44) 9.21 (0.362) 12.1 (0.48) 11.9 (0.47) 6.8 (0.268) 2.8 (0.11) 2.0 (0.08) 1 2 3 4 5 6 7 2x2.0 (2x0.08) (0.008) S Dimensions in [mm], () = Inch Tolerances: x.x ±0.5 (±0.02) x.xx ±0.25 (±0.01) Pin pitch tolerances ±0.25 (±0.01) Pin dimension tolerance ±0.1 (±0.004) Pinout Pin Single Dual 1 –Vin (GND) –Vin (GND) 2 +Vin (Vcc) +Vin (Vcc) 3 +Vout +Vout 4 no pin Common 5 –Vout –Vout
6 NC NC
7 NC NC
NC: Not Connected Dimensions in mm (inch) 2.0 (0.08) 2.0 (0.08) 1.2 (0.047) 8.8 (0.346) 4.8 (0.189) 12.9 (0.51) 3.0 (0.12) 6.8 (0.268) 8.2 (0.32) 2.44 (0.096) 14.1 (0.56) © Copyright 2022 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 4 / 4