AC/DC Medical Power Supply TPP 65E-D Series, 65 Watt

  • Compact encapsulated 65 Watt PCB module (3.2"x2.2")
  • I/O isolation 4000 VAC rated for 250 VAC working voltage
  • Certification according to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP
  • Risk management process according to ISO 14971 incl. risk management file
  • Acceptance criteria for electronic assemblies acc. to IPC-A-610 Level 3
  • Low leakage current <100 μA rated for BF applications
  • Operating temperature –40°C to 80°C
  • EMC compliance according to IEC 60601-1-2 4th edition and EN 55032 class B
  • Operating up to 5000 m altitude
  • 5-year product warranty IEC 60601-1 IEC 62368-1 ES 60601-1 UL 62368-1 The TPP 65E-D is a 65 Watt encapsulated AC/DC modules in a PCB package. It features a reinforced double I/O isolation system according to latest medical safety standards (60601-1 3rd edition, 2 x MOPP). The leakage current is be- low 100 μA and makes the module suitable for BF (body floating) applications. The excellent efficiency of up to 94% allows a high power density and compact design (3.2” x 2.2”). The operating temperature range is –40°C to +80°C with derating above 60°C. The EMC characteristic is dedicated for applications in in- dustrial and medical fields. High reliability is provided by use of high quality components and an excellent thermal management making the TPP 65E-D an ideal solution for medical devices and for demanding safety and space critical applications. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. (adjustable) max. typ. TPP 65-105E-D 50 W 5 VDC (4.5 - 5.5 VDC) 10'000 mA 90 % TPP 65-112E-D 65 W 12 VDC (10.8 - 13.2 VDC) 5'420 mA 93 % TPP 65-115E-D 15 VDC (13.5 - 16.5 VDC) 4'340 mA 94 % TPP 65-124E-D 24 VDC (21.6 - 26.4 VDC) 2'710 mA 94 % TPP 65-136E-D 36 VDC (32.4 - 39.6 VDC) 1'810 mA 93 % TPP 65-148E-D 48 VDC (43.2 - 52.8 VDC) 1'360 mA 93 % www.tracopower.com November 30, 2022 Page 1 / 5

Input Voltage - AC Range Operational Range: 85 - 264 VAC (Full Range) Rated Range: 100 - 240 VAC (Full Range) - DC Range Operational Range: 120 - 370 VDC (Designed for, no certification) Polarity: +DC: L / –DC: N Input Frequency Operational Range: 47 - 440 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 230 VAC 900 mA max. - Full Load & Vin = 115 VAC 1'500 mA max. Power Consumption - No load & Vin = 230 VAC 210 mW max. (Ready to meet ErP directive) - No load & Vin = 115 VAC 210 mW max. Input Inrush Current - At 230 VAC 80 A max. - At 115 VAC 30 A max. Input Protection T 3.15 A / 250 VAC (Internal Fuse L & N) Recommended Input Fuse 3'150 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Specifications Output Voltage Adjustment See application note: ±10% (By external trim resistor) www.tracopower.com/overview/tpp65e-d Output power must not exceed rated power! Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) 0.2% max. - Load Variation (0 - 100%) 0.5% max. Ripple and Noise (20 MHz Bandwidth) 5 VDC model: 100 mVp-p max. (w/ 10 µF) 12 VDC model: 100 mVp-p max. (w/ 10 µF) 15 VDC model: 100 mVp-p max. (w/ 10 µF) 24 VDC model: 120 mVp-p max. (w/ 1 µF) 36 VDC model: 120 mVp-p max. (w/ 1 µF) 48 VDC model: 200 mVp-p max. (w/ 0.1 µF) 5 VDC model: 75 mVp-p typ. (w/ 10 µF) 12 VDC model: 75 mVp-p typ. (w/ 10 µF) 15 VDC model: 75 mVp-p typ. (w/ 10 µF) 24 VDC model: 75 mVp-p typ. (w/ 1 µF) 36 VDC model: 75 mVp-p typ. (w/ 1 µF) 48 VDC model: 150 mVp-p typ. (w/ 0.1 µF) Capacitive Load 5 VDC model: 20'000 µF max. 12 VDC model: 4'520 µF max. 15 VDC model: 2'900 µF max. 24 VDC model: 1'130 µF max. 36 VDC model: 520 µF max. 48 VDC model: 285 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Hold-up Time - At 230 VAC 75 ms min. - At 115 VAC 16 ms min. Start-up Time - At 230 VAC 1'000 ms max. - At 115 VAC 1'000 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 120 - 180% of Iout max. 145% typ. of Iout max. Overvoltage Protection 130% typ. of Vout nom. 125 - 140% of Vout nom. Output Specifications TPP 65E-D Series, 65 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 5

Transient Response - Response Deviation 3% max. (50% to 75% Load Step at 2.5 A/µs) - Response Time 600 µs typ. (50% to 75% Load Step at 2.5 A/µs) Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 2 x MOPP (Means Of Patient Protection) - Certification Documents www.tracopower.com/overview/tpp65e-d Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications EMI Emissions - Conducted Emissions EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15 class B (internal filter) FCC Part 18 class B (internal filter) - Radiated Emissions EN 55011 class B (internal filter) EN 55032 class B (internal filter) FCC Part 15 class B (internal filter) FCC Part 18 class B (internal filter) - Harmonic Current Emissions EN 61000-3-2, class A - Voltage Fluctuations & Flicker EN 61000-3-3 EMS Immunity EN 60601-1-2 edition 4 (Medical Devices) - Electrostatic Discharge Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 20 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 20 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: EN 61000-4-11 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 1 period, perf. criteria A >95%, 250 periods, perf. criteria B

115 VAC / 60 Hz: EN 61000-4-11

30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A >95%, 1 period, perf. criteria A >95%, 250 periods, perf. criteria B EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +85°C - Storage Temperature –40°C to +85°C Power Derating - High Temperature Depending on model - Low Input Voltage Depending on model See application note: www.tracopower.com/overview/tpp65e-d Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. Switching Frequency 50 - 130 kHz (PWM QR) General Specifications TPP 65E-D Series, 65 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 5

Insulation System Reinforced Insulation Working Voltage (rated) 250 VAC Isolation Test Voltage - Input to Output, 60 s 4'000 VAC - Input to Case or PE, 60 s 2'500 VAC - Output to Case or PE, 60 s 2'500 VAC Creepage - Input to Output 8 mm min. - Input to Case or PE 4 mm min. - Output to Case or PE 4 mm min. Clearance - Input to Output 4 mm min. - Input to Case or PE 4 mm min. - Output to Case or PE 4 mm min. Isolation Resistance - Input to Output, 500 VDC 100 MΩ min. Isolation Capacitance - Input to Output, 100 kHz, 1 V 1'250 pF typ. / 1'500 pF max. Leakage Current - Touch Current 100 µA max. Reliability - Calculated MTBF 1'494'000 h (MIL-HDBK-217F, ground benign) Washing Process Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf Environment - Vibration IEC 60068-2-6 5 g, 3 axis, sine sweep, 3x30 min, 5-500 Hz - Mechanical Shock IEC 60068-2-27 50 g, 3 axis, 11 ms - Thermal Shock MIL-STD-810F -40 to +85°C, 72 cycles, 30 min each Housing Material Plastic (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) Pin Material Tinned Copper Pin Foundation Plating Nickel (2 - 3 µm) Pin Surface Plating Tin (3 - 5 µm), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Soldering Profile Wave Soldering 260°C / 6 s Weight 265 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tpp65e-d TPP 65E-D Series, 65 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 4 / 5

TPP 65E-D Series, 65 Watt SIDE VIEW BOTTOM VIEW All dimensions in mm (inch) Tolerance: X.X ±0.5 (X.XX ±0.02) X.XX ±025 (X.XXX ±0.010) 69.17 (2.723) 81.3 (3.201) 4.0 (0.157) 2.7 (0.106) 55.9 (2.201) 17.05 (0.671) 69.8 (2.748) 34.9 (1.374) Ø1.0 (0.039) Ø2.0 (0.079) Mounting holes without thread use self-tapping screws 3.99 (0.157) 28.7 (1.130) 7.62 (0.300) 21.47 (0.845) 3.8 (0.150) 30.5 (1.201) 44.45 (1.750) 11.91 (0.469) 19.84 (0.781) Mounting Holes depth total: 17.05 (0.671) Counterbore depth: 2.05 (0.807) Pinout Pin Function

1 AC (N)

2 AC (L)

4 Trim

5 Vout