DC/DC Railway Converter TMR 6WIR Series, 6 Watt
- Compact SIP-8 metal case
- EN 50155 railway approval
- Ultra wide 4:1 Input: 9–36, 18–75 and 43–160 VDC
- I/O-isolation 3‘000 VDC
- Fully regulated outputs
- Operating temperature range –40°C to +80°C
- Short circuit protection and current limitation
- Remote On/Off
- 3-year product warranty IEC 62368-1UL 62368-1 The TMR 6WIR series is a set of 6 Watt DC/DC converters in a SIP-8 metal case. They operate up to 60°C environment temperature at full load and up to 80°C with a 50% load derating. With EN 50155 and UL 60950-1 certification, 3’000 VDC I/O-isolation voltage, external On/Off, current limitation and short circuit protection they cover a wide range of application when space is limited. The input of the converters is designed for a wide voltage range (4:1) and mini- mum load is not required. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TMR 6-2410WIR 9 - 36 VDC (24 VDC nom.)
3.3 VDC 1'500 mA 81 %
TMR 6-2411WIR 5 VDC 1'200 mA 84 % TMR 6-2419WIR 9 VDC 666 mA 86 % TMR 6-2412WIR 12 VDC 500 mA 87 % TMR 6-2413WIR 15 VDC 400 mA 88 % TMR 6-2415WIR 24 VDC 250 mA 87 % TMR 6-2421WIR +5 VDC 600 mA –5 VDC 600 mA 84 % TMR 6-2422WIR +12 VDC 250 mA –12 VDC 250 mA 87 % TMR 6-2423WIR +15 VDC 200 mA –15 VDC 200 mA 87 % TMR 6-4810WIR 18 - 75 VDC (48 VDC nom.) TMR 6-4811WIR 5 VDC 1'200 mA 84 % TMR 6-4819WIR 9 VDC 666 mA 85 % TMR 6-4812WIR 12 VDC 500 mA 87 % TMR 6-4813WIR 15 VDC 400 mA 87 % TMR 6-4815WIR 24 VDC 250 mA 87 % TMR 6-4821WIR +5 VDC 600 mA –5 VDC 600 mA 84 % TMR 6-4822WIR +12 VDC 250 mA –12 VDC 250 mA 87 % TMR 6-4823WIR +15 VDC 200 mA –15 VDC 200 mA 87 % TMR 6-7210WIR 43 - 160 VDC (110 VDC nom.)
3.3 VDC 1'500 mA 80 %
TMR 6-7211WIR 5 VDC 1'200 mA 83 % TMR 6-7219WIR 9 VDC 666 mA 85 % TMR 6-7212WIR 12 VDC 500 mA 86 % TMR 6-7213WIR 15 VDC 400 mA 86 % TMR 6-7215WIR 24 VDC 250 mA 86 % TMR 6-7221WIR +5 VDC 600 mA –5 VDC 600 mA 83 % TMR 6-7222WIR +12 VDC 250 mA –12 VDC 250 mA 86 % TMR 6-7223WIR +15 VDC 200 mA –15 VDC 200 mA 86 % www.tracopower.com November 30, 2022 Page 1 / 4
Input Current - At no load 24 Vin models: 6 mA typ. 48 Vin models: 6 mA typ. 110 Vin models: 2 mA typ. Surge Voltage 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) 110 Vin models: 185 VDC max. (1 s max.) Recommended Input Fuse 24 Vin models: 1'250 mA (slow blow)
48 Vin models: 630 mA (slow blow)
110 Vin models: 315 mA (slow blow)
(The need of an external fuse has to be assessed in the final application.) Input Filter Internal Capacitor Input Specifications Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.2% max. dual output models: 0.2% max. - Load Variation (0 - 100%) single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Cross Regulation (25% / 100% asym. load) dual output models: 5% max. Ripple and Noise - 20 MHz Bandwidth 50 mVp-p typ. 75 mVp-p max. Capacitive Load - single output 3.3 Vout models: 2'200 µF max. 5 Vout models: 1'100 µF max. 9 Vout models: 680 µF max. 12 Vout models: 470 µF max. 15 Vout models: 470 µF max. 24 Vout models: 180 µF max. - dual output 5 / -5 Vout models: 680 / 680 µF max. 12 / -12 Vout models: 330 / 330 µF max. 15 / -15 Vout models: 180 / 180 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Start-up Time 50 ms typ. / 75 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 180% typ. of Iout max. Transient Response - Response Time 250 µs typ. (25% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Railway Applications EN 50155 - Certification Documents www.tracopower.com/overview/tmr6wir Pollution Degree PD 2 Safety Specifications TMR 6WIR Series, 6 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 4
EMI Emissions - Conducted Emissions EN 55011 class A (with external filter) EN 55011 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) - Radiated Emissions EN 55011 class A (with external filter) EN 55011 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) External filter proposal: www.tracopower.com/overview/tmr6wir EMS Immunity EN 50155 (Railway Applications) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 20 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A Ext. input component: 24 Vin models: KY 220 µF //TVS (SMDJ70A)
48 Vin models: KY 220 µF // TVS (SMDJ120A)
110 Vin models: KY 150 µF // TVS (SMB250A)
- Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +80°C - Case Temperature +100°C max. - Storage Temperature –55°C to +125°C Power Derating - High Temperature 2.5 %/K above 60°C See application note: www.tracopower.com/overview/tmr6wir Cooling System Natural convection (20 LFM) Remote Control - Voltage Controlled Remote On: 0 to 0.5 VDC or open circuit Off: 3 to 12 VDC Refers to 'Remote' and '-Vin' Pin - Off Idle Input Current 2.5 mA typ. Altitude During Operation 5'000 m max. Switching Frequency 270 - 330 kHz (PWM) (110 Vin model) 520 - 640 kHz (PWM) (other input models) Insulation System Functional Insulation Isolation Test Voltage - Input to Output, 60 s 3'000 VDC - Input to Case, 60 s 1'500 VDC Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. Isolation Capacitance - Input to Output, 100 kHz, 1 V 100 pF max. Reliability - Calculated MTBF 2'950'000 h (MIL-HDBK-217F, ground benign) Washing Process Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf Environment - Vibration MIL-STD-810F EN 61373 - Mechanical Shock MIL-STD-810F EN 61373 - Thermal Shock MIL-STD-810F EN 50155 Housing Material Copper Potting Material Silicone (UL 94 V-0 rated) Pin Material Copper Pin Foundation Plating Nickel (1 - 2 µm) Pin Surface Plating Tin (3 - 5 µm), matte General Specifications TMR 6WIR Series, 6 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 4
Connection Type THD (Through-Hole Device) Footprint Type SIP8 Soldering Profile 265°C / 10 s max. Weight 5.9 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) - Flammability (EN 45545-2) www.tracopower.com/info/en45545-declaration.pdf Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tmr6wir Outline Dimensions TMR 6WIR Series, 6 Watt 11.2 (0.44) 4.1 (0.16) 21.8 (0.86) 0.25 (0.01) 9.6 (0.38) 0.5 (0.02) 3.3 (0.13) bottom view 1 2 3 6 7 8 10.6 (0.42) 1.0 (0.04) 0.6 (0.02) 3.5 (0.14) 1.0 (0.04) 2.5 (0.10) t = 0.3 (0.012) Case pins should not be connected to any circuit Dimensions in mm (inch) Tolerances: x.x ±0.5 (±0.02) x.xx ±0.25 (±0.01) Pin pitch Tolerance ±0.25 (±0.01) Pin dimension tolerance ±0.1 (±0.004) Pinout Pin Single Output Dual Output 1 –Vin (GND) –Vin (GND) 2 +Vin (Vcc) +Vin (Vcc)
3 Remote Remote
7 –Vout Common
8 NC –Vout
9, 10 Case Case NC: No Connection © Copyright 2022 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 4 / 4