TML100C TRACOPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Features
u Very compact power modules with screw terminal connection u Active PFC, power factor >0.95 (230VAC), >0.99 (115 VAC) u High efficiency up to 93% typ. u Remote On/Off input u Adjustable output voltage ±5% u LED output indicator u Universal input 100-240 VAC nominal u Low leakage current u EMI meets EN 55032, class B u Protection class ll prepared Order code Output power max. Output voltage Output current max. Efficiency TML 100-1 1 2C 85 1 2 VDC 7080 mA 90 % TML 100-1 15C 85 1 5 VDC 5660 mA 90 % TML 100-1 24C 100 24 VDC 4200 mA 92 % TML 100-148C 100 48 VDC 2 100 mA 93 % Models UL 60950-1 Series Description Datasheet TMLM 04 4 Watt, PCB mount, single and dual output models TMLM 05 5 Watt, PCB mount, single output models www.tracopower.com/products/tmlm.pdf TMLM 10 10 Watt, PCB mount, single output models TMLM 20 20 Watt, PCB mount, single output models (compact design) TML 20 20 Watt, PCB & chassis mount, single, dual and triple output models www.tracopower.com/products/tml.pdf TML 40 40 Watt, PCB & chassis mount, single, dual and triple output models Full TML and TMLM Series Model Range
www.tracopower.com Page 2 of 3 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. AC/DC Power Modules TML 100C Series 85-100 Watt Input Specifications Input voltage ranges – nominal 100 – 240 VAC (universal input) – AC full range 90 – 264 VAC – DC Input 120 – 370 VDC Input frequency 47 – 63 Hz Input current at full load (1 15 VAC / 230 VAC nominal input) < 2.0 A / < 1.0 A max. Leakage current 0.5 mA max. Harmonic limits EN 61000-3-2, Class A – Power factor >0.99 at 115 VAC, >0.95 at 230 VAC Output Specifications Voltage set accuracy ±2 % Output voltage adjustment range ±5% (see page 3) Minimum load 3% of rated max current (operation at lower load condition is safe but a higher output ripple will be experianced) Ripple and noise (20 MHz bandwidth) 12 VDC model: 120 mV max. 15 VDC model: 150 mV max. 24 VDC model: 200 mV max. 48 VDC model: 240 mV max. Regulation – input variation ±1% – load variation ±1% Current limitation 105% – 180% of rated output power. (automatic recovery) Overvoltage protection by Zener diode Short circuit protection indefinite (hiccup, automatic recovery) Hold-up time 10 ms min. (110VAC) Max. capacitive load 12 VDC model: 50‘000 µF
15 VDC model: 40‘000 µF
24 VDC model: 6‘000 µF
48 VDC model: 560 µF
Temperature ranges – Operating –25°C to +70°C – Power derating above +50°C 3.75 %/K – Case max. +95°C – Storage (non operating) –25°C to +85°C Temperature coefficient 0.03 %/K Efficiency see model table Remote On/Off control On: open or connection to -Vout Off: external +5VDC Humidity (non condensing) 95 % rel max. Altitude during operation 2‘000 m max. Switching frequency (pulse width modulation PWM) 100–133 kHz Isolation voltage – Input/Output 3‘000 VAC Working voltage (rated) 286 VAC Reliability / calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >250’000 h Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf – RoHS Ro H S d i r e c t i ve 2011/6 5/E U
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www .tracopower.com AC/DC Power Modules TML 100C Series 85-100 Watt Rev. March 21, 2023 General Specifications Electromagnetic compatibility (EMC), Emissions EN 61000-3-2:2006+A1:2009+A2:2009 EN 61000-3-3:2008 EN 55032 class B (internal filter) Electromagnetic compatibility (EMC), Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) – Electrostatic discharge ESD (air/contact) EN 61000-4-2 ±2 kV / ±4 kV, criteria A – RF field susceptibility EN 61000-4-3 3 V/m, criteria A – Electrical fast transient / burst immunity input EN 61000-4-4 ±1 kV, criteria A – Surge immunity line – neutral EN 61000-4-5, ±1 kV, criteria A – Surge immunity line – PE, neutral – PE EN 61000-4-5 ±2 kV, criteria A – Immunity to conducted RF disturbances EN 61000-4-6 3 V, criteria A – Power frequency magnetic field immunity EN 61000-4-8 1 A/m, criteria A – Mains voltage dips and interruptions EN 61000-4-11 30 % 500 ms, criteria A 95 % 10 ms, criteria A 95 % 2500 ms, criteria C Protection class class I and class II prepared Safety standards IEC/EN 60950-1, UL 60950-1 IEC/EN 62368-1, UL 62368-1 Safety approvals – Certification documents www.tracopower.com/ overview/tml100c Casing material plastic resin + fiberglass (UL 94V-0 rated) output voltage 12 VDC 15 VDC 24 VDC 48 VDC +5% 85 95 90 85 nominal open open open open –5% 220 300 600 1500 Trim up: Resistor from Trim to -Vout (conection 7-6) Trim down: Resistor from Trim to +Vout (conection 7-5) Output voltage adjustment ( Trim resistor [KOhm]) Weight : 440 g (15.5 oz) Outline Dimensions Connection con. Output
1 AC in (L)
2 AC in (N)
4 Remote On/Off
7 Trim
6.0 128.0 140.0+0.2 /endash.case0.0 +0.2 /endash.case0.0 +0.008/endash.case0.000 +0.008/endash.case0.000 (5.04) (5.5 ) 13.0 24.0 (0.945) (0.512) (0.24) 50.0(2.0) 60.0 D = 4x Ø6.5 (4x Ø0.26) D = 3x Ø2.46 (3x Ø0.097) d = 4x Ø4.2 (4x Ø0.17) d = 3x Ø4.0 (3x Ø0.157) (2.36 ) 5.0 (0.20) Top view Side view Bottom View 37.1(1.46) 7.1 (0.28) All dimensions in mm (inch) Tolerances: 0.5 (0.02) LED