TMG30 TRACOPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

AC/DC Power Supply TMG 30 Series, 30 Watt

  • Fully encapsulated power supplies in plastic casing for PCB mount
  • Fully regulated outputs
  • 3000 VAC I/O-isolation
  • High efficiency up to 89%
  • Universal input range 90 to 305 VAC
  • Operating temperature range: –40°C to +70°C max.
  • Safety class II prepared
  • Short circuit over power and over voltage limitation IEC 62368-1UL 62368-1 TMG 30 Series AC/DC power modules come in fully encapsulated plastic pack- age. They are ultra-compact, energy-efficient and cost/performance optimised for prevailing market requirements. The high efficiency and the use of high grade components make these modules suitable for an operating temperature range of –40°C to +70°C. Together with very low no-load power consumption they are suitable for applications conforming with the ErP directive. The mod- ules are protected against short-circuit and over voltage. EMI/EMC characteris- tics and the safety approval package qualify them for demanding applications in equipment for industrial or commercial environments. Models Order Code Output Power Output Voltage Output Current Efficiency max. nom. max. typ. TMG 30103 16.5 W 3.3 VDC 5'000 mA 80 % TMG 30105 25 W 5 VDC 5'000 mA 84 % TMG 30112 30 W

12 VDC 2'500 mA 89 %

TMG 30115 15 VDC 2'000 mA 86 % TMG 30124 24 VDC 1'250 mA 86 % www.tracopower.com March 16, 2023 Page 1 / 4

Input Voltage - AC Range Operational Range: 90 - 305 VAC (Full Range) Rated Range: 100 - 277 VAC (Full Range) - DC Range Operational Range: 120 - 430 VDC (Designed for, no certification) Polarity: irrelevant Input Frequency Operational Range: 47 - 440 Hz Certified: 50/60 Hz Input Current - Full Load & Vin = 230 VAC 400 mA max. - Full Load & Vin = 115 VAC 600 mA max. Power Consumption - No load & Vin = 230 VAC 300 mW max. (Ready to meet ErP directive) - No load & Vin = 115 VAC 300 mW max. Input Inrush Current - At 230 VAC 60 A max. - At 115 VAC 30 A max. (For the 7 & 15 W models an external Thermistor has to be integreated in the circuit at the converter input L in series. Thermistor recommendation: 10R / 15z) Recommended Input Fuse 3'150 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Specifications Voltage Set Accuracy ±2% max. Regulation - Input Variation (Vmin - Vmax) 0.5% max. - Load Variation (0 - 100%) 1.5% max. (3.3 VDC model) 1% max. (other models) Ripple and Noise (20 MHz Bandwidth) 3.3 VDC model: 33 mVp-p max. (w/ 0.1 µF || 47 µF) 5 VDC model: 120 mVp-p max. (w/ 0.1 µF || 47 µF) 12 VDC model: 120 mVp-p max. (w/ 0.1 µF || 47 µF) 15 VDC model: 150 mVp-p max. (w/ 0.1 µF || 47 µF) 24 VDC model: 240 mVp-p max. (w/ 0.1 µF || 47 µF) Capacitive Load 3.3 VDC model: 6'800 µF max. 5 VDC model: 6'800 µF max. 12 VDC model: 1'600 µF max. 15 VDC model: 1'200 µF max. 24 VDC model: 470 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Hold-up Time - At 230 VAC 50 ms min. - At 115 VAC 10 ms min. Start-up Time - At 230 VAC 250 ms max. - At 115 VAC 400 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 172 - 268% of Iout max. Overvoltage Protection 105 - 145% of Vout nom. (By Zener diode) Transient Response - Response Deviation 2% max. (75% to 100% Load Step) - Response Time 500 µs typ. (75% to 100% Load Step) Output Specifications TMG 30 Series, 30 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 4

Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/tmg30 Protection Class Class I & II (Prepared): Reinforced Insulation Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications EMI Emissions - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) EMS Immunity EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±4 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A L to L: EN 61000-4-5, ±1 kV, perf. criteria A Ext. input component: Use an external Varistor at the converter input (in parallel). Recommendation: 14S471K - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 30 A/m, perf. criteria A - Voltage Dips & Interruptions 230 VAC / 50 Hz: 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A 115 VAC / 60 Hz: 30%, 25 periods, perf. criteria A >95%, 0.5 periods, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +70°C - Storage Temperature –40°C to +85°C Power Derating - High Temperature 3 %/K above 50°C (nominal input models) 3 %/K above 45°C (<115 VAC models) - Low Input Voltage 2 %/V below 100 VAC See application note: www.tracopower.com/overview/tmg30 Cooling System Natural convection (20 LFM) Altitude During Operation 2'000 m max. Switching Frequency 40 - 73 kHz (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 341 VAC Isolation Test Voltage - Input to Output, 60 s 3'000 VAC Creepage - Input to Output 5.6 mm min. Clearance - Input to Output 4 mm min. Leakage Current (at 240 VAC) - Earth Leakage Current 250 µA max. Reliability - Calculated MTBF 400'000 h (MIL-HDBK-217F, ground benign) Washing Process Not allowed Housing Material Plastic resin (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) (Hermetical sealed structure, dust-proof only non water-proof) Pin Material Brass Pin Surface Plating Tin (120 µm min.), matte General Specifications TMG 30 Series, 30 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 4

Connection Type THD (Through-Hole Device) Weight 130 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tmg30 Outline Dimensions TMG 30 Series, 30 Watt Dimensions in mm Tolerances ±0.5 mm Pin tolerances ±0.1 mm 64.0 23.5 8.0 Ø 1.0 6.0 32.0 4.0 45.0 10.0 10.0 22.5 17.5 54.0 T Case top view Pinout Pin Function

1 AC IN (N)

2 AC IN (L)

3 –Vout 5 +Vout © Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 4 / 4