www.tracopower.com Page 1 of 4 RIA 12 Filter TFI 150 Series, 150 Watt Models Order code Input voltage Power max. TFI 150 43 – 160 VDC 150 W Models The new TFI 150 is a surge filter which comes in a compact 1.6” x 1” plastic package. Placed in front of any DC/DC converter the TFI clamps momentary over-voltage transients to a safe value in order to protect the DC/DC converter from being damaged. During normal operation the output voltage follows the input voltage (Vout = Vin – 2 VDC typ.) up to the point of 168 VDC where the voltage is actively clamped. Whereas the transients defined within the EN 50155 (up to 154 VDC) are covered by the wide input range of dedicated railway converters the TFI handles the stricter definition laid-out in the RIA12 standard which allows transients of up to 20ms at 385 VDC. This level of protection is specifically required in railway applications where high voltage transients are expected but can also be used for 72, 96 and 110 VDC battery systems in railway applications.

  • Clamps over voltage transients (up to 385 VDC) at 168 VDC
  • Universal use: Can be used with any DC/DC converter
  • Complies with RIA12, NF F 01-510 Surge susceptibilities
  • Wide input voltage range: 43 – 160 VDC
  • Brownout voltage 36 VDC min.
  • Operating temperature range -40 to +95°C
  • 3-year product warranty

TFI 150 Series, 150 Watt www.tracopower.com Page 2 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Input Specifications Start-up Voltage 30 VDC max. Transient Voltage – 1 s max. 165 VDC max. – 100 ms max. 176 VDC max. – 20 ms max. 385 VDC max. Brownout 36 VDC min. Output Specifications Output Voltage Vin - 2 VDC typ. / Vin - 1 VDC max. Clamping Voltage – Input Transient Voltage Mode 168 VDC typ. General Specifications Standards RIA 12 Surge Susceptibility NF F 01-510 Surge Susceptibility Case Material Non-conductive black plastic Base Material Non-conductive black plastic Potting Material Silicone (UL94 V-0) Weight 22 g Temperature ranges – Operating (with derating) –40°C to +95°C – Case Temperature +105°C max. – Storage Temperature –55°C to +125°C Relative Humidity 95% max. (non condensing) Thermal Shock MIL-STD-810F Vibration MIL-STD-810F Characeristic Curves Transient Function

TFI 150 Series, 150 Watt www.tracopower.com Page 3 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Possible Application +Vin –Vin +Vout –Vout DC/DC CoutInput LoadEMI Filter*TFIEMS Filter* +Vin –Vin +Vout –Vout DC/DCInput LoadTFI Surge Voltage Clamping Voltage Schematic for typical application 385 V max. 168 V typ. 20 ms max. Input Surge Voltage Clamping Voltage Input Surge Voltage vs. Clamping Voltage The TFI (RIA 12 Filter) clamps over-voltage to a safe value in order to protect the power module from damaging. *Optional, depending on DC/DC converter. RIA 12 The commonly in railway applications used RIA 12 standard has been withdrawn but is still in demand. A comparison between EN 50155 and RIA 12 standard values is shown in the table below. EN 50155 Standard RIA 12 Standard Vnom [VDC] Input Range Brownout Transient Brownout Transient Transient 0.7 to 1.25 Vnom 100 ms

0.6 Vnom

1‘000 ms

1.4 Vnom

1‘000 ms

1.5 Vnom

3.5 Vnom

TFI 150 Series, 150 Watt www .tracopowe r.com © Copyright 2021 Traco Electronic AG Specifications can be changed without notice! Page 4 of 4 Rev. July 7, 2021 Outline Dimensions Pin Function 1 +Vin 2 NC 3 – Vin 4 +Vout 6 – Vout Pin-Out Dimensions in mm (Inch) Tolerances: x.x ±0.5 (±0.02) x.xx ±0.25 (±0.01) Pin dimesion tolerance ±0.10 (±0.004) Bottom view 25.4 (1.00) 5.08 (0.200) 35.56 (1.400) 40.6 (1.60) 17.78 (0.700) 2.54 (0.100) 5.6 (0.22) 10.4 (0.40) ø1.0 (ø0.04)