DC/DC Railway Converter TEQ 40WIR Series, 40 Watt

  • High power block with excellent thermal convection
  • Operating temperature -40°C to +92°C
  • Ultra wide 4:1 input voltage range
  • EN 50155 approval for railway

applications

  • Excellent efficiency up to 91%
  • Input filter meet EN 55022, class B
  • I/O isolation up to 2121 VAC
  • Under voltage lock-out circuit
  • Protection against overvoltage, overtemperature and short circuit
  • Output LED indicator IEC 62368-1UL 62368-1 The TEQ 40WIR Series is a family of isolated high performance DC/DC convert- er modules with ultra-wide 4:1 input voltage ranges which come in a rugged metal case. These converters are suitable for a wide range of applications, but the product is designed particularly also for industrial applications where often no PCB mounting is possible but the module has to be mounted on a chassis. A very high efficiency and the heatsink construction allows an operating tem- perature up to +83°C with natural convection cooling without power derating and up to +92°C with power derating. Further features include under voltage lockout, over temperature protection and short circuit protection. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TEQ 40-2411WIR 9.5 - 36 VDC (24 VDC nom.)

5 VDC 8'000 mA 90 %

TEQ 40-2412WIR 12 VDC 3'330 mA 91 % TEQ 40-2413WIR 15 VDC 2'670 mA 91 % TEQ 40-2415WIR 24 VDC 1'670 mA 90 % TEQ 40-2422WIR +12 VDC 1'670 mA –12 VDC 1'670 mA 89 % TEQ 40-2423WIR +15 VDC 1'330 mA –15 VDC 1'330 mA 89 % TEQ 40-2425WIR +24 VDC 830 mA –24 VDC 830 mA 90 % TEQ 40-4811WIR 18 - 75 VDC (48 VDC nom.) TEQ 40-4812WIR 12 VDC 3'330 mA 91 % TEQ 40-4813WIR 15 VDC 2'670 mA 91 % TEQ 40-4815WIR 24 VDC 1'670 mA 90 % TEQ 40-4822WIR +12 VDC 1'670 mA –12 VDC 1'670 mA 89 % TEQ 40-4823WIR +15 VDC 1'330 mA –15 VDC 1'330 mA 89 % TEQ 40-4825WIR +24 VDC 830 mA –24 VDC 830 mA 90 % TEQ 40-7211WIR 43 - 160 VDC (110 VDC nom.)

5 VDC 8'000 mA 88 %

TEQ 40-7212WIR 12 VDC 3'330 mA 90 % TEQ 40-7213WIR 15 VDC 2'670 mA 90 % TEQ 40-7215WIR 24 VDC 1'670 mA 89 % TEQ 40-7222WIR +12 VDC 1'670 mA –12 VDC 1'670 mA 88 % TEQ 40-7223WIR +15 VDC 1'330 mA –15 VDC 1'330 mA 88 % TEQ 40-7225WIR +24 VDC 830 mA –24 VDC 830 mA 90 % www.tracopower.com March 16, 2023 Page 1 / 4

Input Current - At no load 24 Vin models: 19 mA typ. 48 Vin models: 14 mA typ. 110 Vin models: 10 mA typ. Surge Voltage 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) 110 Vin models: 170 VDC max. (1 s max.) Input Inrush Current 15 A typ. Under Voltage Lockout 24 Vin models: 7 VDC min. / 8 VDC typ. / 9 VDC max. 48 Vin models: 15 VDC min. / 16 VDC typ. / 17.5 VDC max. 110 Vin models: 37 VDC min. / 40 VDC typ. / 42 VDC max. Recommended Input Fuse 24 Vin models: 8'000 mA (fast acting)

48 Vin models: 4'000 mA (slow blow)

110 Vin models: 2'000 mA (slow blow)

(The need of an external fuse has to be assessed in the final application.) Reverse Voltage Protection Parallel diode Input Specifications Voltage Set Accuracy ±1% max. (Single Output) +1% / -1.2% (Dual Output) Regulation - Input Variation (Vmin - Vmax) single output models: 0.5% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 1.5% max. (5 VDC models) 1% max. (other models) dual output models: 1% max. (Output 1) 1% max. (Output 2) - Cross Regulation (25% / 100% asym. load) dual output models: 5% max. Ripple and Noise (20 MHz Bandwidth) - single output 5 Vout models: 75 mVp-p max. 12 Vout models: 100 mVp-p max. 15 Vout models: 100 mVp-p max. 24 Vout models: 150 mVp-p max. - dual output 12 / -12 Vout models: 100 / 100 mVp-p max. 15 / -15 Vout models: 100 / 100 mVp-p max. 24 / -24 Vout models: 150 / 150 mVp-p max. Capacitive Load - single output 5 Vout models: 20'000 µF max. 12 Vout models: 3'900 µF max. 15 Vout models: 2'600 µF max. 24 Vout models: 1'300 µF max. - dual output 12 / -12 Vout models: 2'600 / 2'600 µF max. 15 / -15 Vout models: 1'600 / 1'600 µF max. 24 / -24 Vout models: 650 / 650 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Hold-up Time 10 ms min. (acc. EN50155 class S2) Start-up Time 100 ms typ. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 150% typ. of Iout max. Overvoltage Protection 125% typ. of Vout nom. Transient Response - Response Time 250 µs typ. (25% Load Step) Output Specifications TEQ 40WIR Series, 40 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 4

Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Industrial Control Equipment Designed for UL 508 (no certification) (single output models only) - Railway Applications EN 50155 - Certification Documents www.tracopower.com/overview/teq40wir Pollution Degree PD 2 Safety Specifications EMI Emissions EN 50121-3-2 (EMC for Rolling Stock) - Conducted Emissions EN 55032 class B (internal filter) - Radiated Emissions EN 55032 class B (internal filter) EMS Immunity EN 50155 (Railway Applications) EN 50121-3-2 (EMC for Rolling Stock) EN 55024 (IT Equipment) EN 55035 (Multimedia) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 20 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±1 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A 1 s: EN 61000-4-8, 1000 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +83°C - Storage Temperature –40°C to +105°C Power Derating - High Temperature Depending on model See application note: www.tracopower.com/overview/teq40wir Over Temperature Protection Switch Off - Protection Mode 105°C min. / 115°C typ. / 120°C max. (Automatic recovery) Cooling System Natural convection (20 LFM) Altitude During Operation 2'000 m max. Switching Frequency 225 - 275 kHz (PWM) 250 kHz typ. (PWM) Insulation System Functional Insulation Isolation Test Voltage - Input to Output, 60 s 3'000 VDC - Input to Case, 60 s 2'000 VDC - Output to Case, 60 s 2'000 VDC Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. Isolation Capacitance - Input to Output, 100 kHz, 1 V 5'000 pF typ. Reliability - Calculated MTBF 1'000'000 h (MIL-HDBK-217F, ground benign) Environment - Vibration MIL-STD-810F EN 61373 - Mechanical Shock MIL-STD-810F EN 61373 - Thermal Shock MIL-STD-810F EN 50155 Housing Material Aluminum General Specifications TEQ 40WIR Series, 40 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 4

Mounting Type Chassis Mount Connection Type Spring Clamps Weight 129 g Status Indicator Indicated by green LED Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) - Flammability (EN 45545-2) www.tracopower.com/info/en45545-declaration.pdf Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/teq40wir Outline Dimensions TEQ 40WIR Series, 40 Watt 26.1 (1.03) Dimensions in mm, ( ) = inch Tolerances: x.x ±0.5 (±0.02) x.xx ±0.25 (±0.01) Screw max. torque: 5.0 kgf - cm (0.49 Nm) Spring terminals: 12 - 18 AWG BOTTOM VIEW TOP VIEW Hole screw 2 M3x0.5 Output On LED 103.0 (4.06) 92.10 (3.626) 6.5 (0.26) 3.5 (0.14) 57.2 (2.25) NC: No Connection Pinout Pin Single Output Dual Output 1 +Vin +Vin 2 –Vin (GND) –Vin (GND)

3 NC NC

4 NC –Vout

5 –Vout Common 6 +Vout Common

7 NC +Vout

© Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 4 / 4