TEQ200WIR TRACOPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 4
Technical content
DC/DC Railway Converter TEQ 200WIR Series, 200 Watt
- High power block with excellent thermal convection
- Operating temperature -40°C to +70°C without derating
- Increased shock & vibration resistance
- Ultra wide 4:1 input voltage range
- EN 50155 approval for railway
applications
- Excellent efficiency up to 90%
- Input filter meet EN 55032, class A
- I/O insulation 1591 VAC
- Under voltage lock-out circuit IEC 62368-1UL 62368-1UL 508 The TEQ 200WIR Series is a family of isolated high performance DC/DC con- verter modules with ultra-wide 4:1 input voltage ranges which come in a rugged, sealed metal case. These converters are suitable for a wide range of applications, but the product is designed particularly also for industrial applications where often no PCB mounting is possible but the module has to be mounted on a chassis. A very high efficiency and the overall heatsink construction allows an operating tem- perature up to +70°C with natural convection cooling without power derating and up to +90°C with power derating. Further features include output voltage trimming, Remote On/Off and under voltage lockout. The very wide input volt- age range and reverse input voltage protection make these converters also an interesting solution for battery operated systems. Models Order Code Input Voltage Output Voltage Output Current Efficiency Range nom. (adjustable) max. typ. TEQ 200-4812WIR 19 - 75 VDC (48 VDC nom.) 12 VDC (9.6 - 13.2 VDC) 18'000 mA 89 % TEQ 200-4815WIR 24 VDC (19.2 - 26.4 VDC) 9'000 mA 89 % TEQ 200-4816WIR 28 VDC (22.4 - 30.8 VDC) 7'500 mA 90 % TEQ 200-4818WIR 48 VDC (38.4 - 52.8 VDC) 4'500 mA 89 % TEQ 200-7212WIR 43 - 160 VDC (110 VDC nom.) 12 VDC (9.6 - 13.2 VDC) 20'000 mA 88 % TEQ 200-7215WIR 24 VDC (19.2 - 26.4 VDC) 10'000 mA 88 % TEQ 200-7216WIR 28 VDC (22.4 - 30.8 VDC) 8'500 mA 89 % TEQ 200-7218WIR 48 VDC (38.4 - 52.8 VDC) 5'000 mA 88 % Options TEQ-MK1 - Optional DIN-Rail Mounting Kit: www.tracopower.com/products/teq-mk1.pdf www.tracopower.com March 16, 2023 Page 1 / 4
Input Current - At no load 48 Vin models: 23 mA typ. 110 Vin models: 13 mA typ. Surge Voltage 48 Vin models: 100 VDC max. (1 s max.) 110 Vin models: 185 VDC max. (1 s max.) 110 Vin models: 33 VDC min. / 35.5 VDC typ. / 38 VDC max. Recommended Input Fuse (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Common Mode Choke + Pi-Type Input Specifications Output Voltage Adjustment –20% to +10% (By trim potentiometer) Output power must not exceed rated power! Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) 0.1% max. - Load Variation (0 - 100%) 0.1% max. Ripple and Noise (20 MHz Bandwidth) 12 Vout models: 100 mVp-p typ. 24 Vout models: 200 mVp-p typ. 28 Vout models: 200 mVp-p typ. 48 Vout models: 300 mVp-p typ. 12 Vout models: 125 mVp-p max. 24 Vout models: 250 mVp-p max. 28 Vout models: 250 mVp-p max. 48 Vout models: 350 mVp-p max. Capacitive Load - 48 Vin input 12 Vout models: 15'000 µF max. 24 Vout models: 3'700 µF max. 28 Vout models: 2'600 µF max. 48 Vout models: 930 µF max. - 110 Vin input 12 Vout models: 16'600 µF max. 24 Vout models: 4'100 µF max. 28 Vout models: 3'000 µF max. 48 Vout models: 1'000 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Start-up Time 75 ms typ. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 120 - 150% of Iout max. Overvoltage Protection 115 - 130% of Vout nom. Transient Response - Response Time 200 µs typ. / 250 µs max. (25% Load Step) Output Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Industrial Control Equipment UL 508 - Railway Applications EN 50155 - Certification Documents www.tracopower.com/overview/teq200wir Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications TEQ 200WIR Series, 200 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 2 / 4
EMI Emissions EN 50121-3-2 (EMC for Rolling Stock) - Conducted Emissions EN 55011 class A (internal filter) EN 55032 class A (internal filter) - Radiated Emissions EN 55011 class A (internal filter) EN 55032 class A (internal filter) EMS Immunity EN 50155 (Railway Applications) EN 50121-3-2 (EMC for Rolling Stock) EN 55024 (IT Equipment) EN 55035 (Multimedia) EN 61204-3 (Low Voltage Power Supplies) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 20 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +90°C - Storage Temperature –40°C to +105°C Power Derating - High Temperature Depending on model See application note: www.tracopower.com/overview/teq200wir Over Temperature Protection Switch Off - Protection Mode 105°C min. / 115°C typ. / 120°C max. (Automatic recovery) Cooling System Natural convection (20 LFM) Sense Function 10% max. of Vout nom. Remote Control - Voltage Controlled Remote On: 3.0 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin - Off Idle Input Current 8 mA max. - Remote Pin Input Current -0.5 to 1.0 mA Altitude During Operation 2'000 m max. Switching Frequency 225 - 275 kHz (PWM) 250 kHz typ. (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 182 VAC Isolation Test Voltage - Input to Output, 60 s 2'250 VDC - Input to Case, 60 s 1'600 VDC - Output to Case, 60 s 1'600 VDC Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. Reliability - Calculated MTBF 270'000 h (MIL-HDBK-217F at 55°C, ground benign) Environment - Vibration MIL-STD-810F EN 61373 - Mechanical Shock MIL-STD-810F EN 61373 - Thermal Shock MIL-STD-810F EN 50155 Housing Material Aluminum Potting Material Silicone (UL 94 V-0 rated) Housing Type Metal Case Mounting Type Chassis Mount Connection Type Spring Clamps General Specifications TEQ 200WIR Series, 200 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com March 16, 2023 Page 3 / 4
Thermal Impedance - Case to Ambient 1.45 K/W typ. Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) - Flammability (EN 45545-2) www.tracopower.com/info/en45545-declaration.pdf Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/teq200wir Outline Dimensions TEQ 200WIR Series, 200 Watt 87.6 (3.45) 88.9 (3.50) 76.2 (3.00) 79.1 (3.114) 103.2 (4.06) 74.2 (2.92) 3.2 (0.13) Screw 4–M3X0.5 Output voltage adjust TOP VIEW Output ON LED Dimensions in mm, (inch) Tolerances: x.xx ±0.5 (±0.02) Terminal connection Terminal Pin Function Recommended Wire 1,2 –Vin 12 AWG
3 NC NC
4 Remote 14 - 18 AWG
5, 6 +Vin 12 AWG 7, 8 –Vout 12 AWG 9 –Sense* 14 - 18 AWG 10 +Sense* 14 - 18 AWG 11, 12 +Vout 12 AWG NC: No Connection * Sense line to be connected to the output either at the module or at the load under regard of polarity.
- The current rating of the terminal block is 15 A/pole.
- Using 2 poles in parallel if the peak output current can exceed 15 A.
- Wire size shall be selected to withstand the peak out- put current (Iout max + Current limitation). © Copyright 2023 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. March 16, 2023 Page 4 / 4