DC/DC Converter TEP 100 Series, 100 Watt

  • Rugged, compact metal case
  • Screw terminal adaptor available for easy connection
  • Wide 2:1 input voltage range
  • Full load operation up to 60°C with convection cooling
  • Soft start
  • Under voltage lock-out circuit
  • Reverse input voltage protection
  • Input protection filter
  • 3-year product warranty IEC 62368-1UL 62368-1 The TEP 100 Series is a family of isolated high performance DC/DC converter modules with ultra-wide 2:1 input voltage ranges which come in a rugged, sealed metal case. These converters are suitable for a wide range of applica- tions. For easy connection there is also an unique adaptor available with screw terminals. A very high efficiency allows an operating temperature up to +60°C with natural convection cooling without power derating. Further features in- clude output voltage trimming, Remote On/Off and under voltage lockout. The very wide input voltage range make these converters also an interesting solu- tion for battery operated systems. Models Order Code Input Voltage Output Voltage Output Current Efficiency Range nom. (adjustable) max. typ. TEP 100-1210 9 - 18 VDC (12 VDC nom.) 3.3 VDC (2.64 - 3.63 VDC) 25'000 mA 90 % TEP 100-1211 5 VDC (4.0 - 5.5 VDC) 20'000 mA 91 % TEP 100-1212 12 VDC (9.6 - 13.2 VDC) 8'400 mA 91 % TEP 100-1213 15 VDC (12.0 - 16.5 VDC) 6'700 mA 91 % TEP 100-1215 24 VDC (19.2 - 26.4 VDC) 4'200 mA 90 % TEP 100-1216 28 VDC (22.4 - 30.8 VDC) 3'600 mA 90 % TEP 100-1218 48 VDC (38.4 - 52.8 VDC) 2'100 mA 90 % TEP 100-2410 18 - 36 VDC (24 VDC nom.) 3.3 VDC (2.64 - 3.63 VDC) 25'000 mA 91 % TEP 100-2411 5 VDC (4.0 - 5.5 VDC) 20'000 mA 93 % TEP 100-2412 12 VDC (9.6 - 13.2 VDC) 8'400 mA 93 % TEP 100-2413 15 VDC (12.0 - 16.5 VDC) 6'700 mA 93 % TEP 100-2415 24 VDC (19.2 - 26.4 VDC) 4'200 mA 92 % TEP 100-2416 28 VDC (22.4 - 30.8 VDC) 3'600 mA 92 % TEP 100-2418 48 VDC (38.4 - 52.8 VDC) 2'100 mA 92 % TEP 100-4810 36 - 75 VDC (48 VDC nom.) 3.3 VDC (2.64 - 3.63 VDC) 25'000 mA 91 % TEP 100-4811 5 VDC (4.0 - 5.5 VDC) 20'000 mA 93 % TEP 100-4812 12 VDC (9.6 - 13.2 VDC) 8'400 mA 93 % TEP 100-4813 15 VDC (12.0 - 16.5 VDC) 6'700 mA 93 % TEP 100-4815 24 VDC (19.2 - 26.4 VDC) 4'200 mA 92 % TEP 100-4816 28 VDC (22.4 - 30.8 VDC) 3'600 mA 92 % TEP 100-4818 48 VDC (38.4 - 52.8 VDC) 2'100 mA 92 % www.tracopower.com November 30, 2022 Page 1 / 5

Suffix -CM - Chassis mount models without filter: www.tracopower.com/products/tep100cm.pdf Suffix -CMF - Chassis mount models with filter to meet EN 55032 class A: www.tracopower.com/products/tep100cmf.pdf TEP-HS1 - Optional Heat Sink: www.tracopower.com/products/tep-hs1.pdf on demand (backorder with MOQ non stocking item) - Optional models with inverse Remote On/Off function (passive = off) Input Current - At no load 12 Vin models: 130 mA typ. 24 Vin models: 120 mA typ. 48 Vin models: 70 mA typ. - At full load 12 Vin models: 9'400 mA max. 24 Vin models: 4'600 mA max. 48 Vin models: 2'300 mA max. Surge Voltage 12 Vin models: 36 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 12 Vin models: 7.5 VDC typ. 24 Vin models: 16 VDC typ. 48 Vin models: 34 VDC typ. Recommended Input Fuse 12 Vin models: 20'000 mA (fast acting)

24 Vin models: 10'000 mA (fast acting)

48 Vin models: 5'000 mA (slow blow)

(The need of an external fuse has to be assessed in the final application.) Reverse Voltage Protection Parallel diode (external input fuse required) Input Filter Internal Pi-Type Input Specifications Output Voltage Adjustment –20% to +10% (By external trim resistor) See application note: www.tracopower.com/overview/tep100 Output power must not exceed rated power! Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) 0.1% max. - Load Variation (0 - 100%) 0.1% max. Ripple and Noise (20 MHz Bandwidth) 3.3 Vout models: 75 mVp-p max. (w/ 4.7 µF X7R) 5 Vout models: 75 mVp-p max. (w/ 4.7 µF X7R) 12 Vout models: 100 mVp-p max. (w/ 4.7 µF X7R) 15 Vout models: 100 mVp-p max. (w/ 4.7 µF X7R) 24 Vout models: 200 mVp-p max. (w/ 4.7 µF X7R) 28 Vout models: 200 mVp-p max. (w/ 4.7 µF X7R) 48 Vout models: 300 mVp-p max. (w/ 2.2 µF X7R) Capacitive Load 3.3 Vout models: 75'700 µF max. 5 Vout models: 40'000 µF max. 12 Vout models: 7'000 µF max. 15 Vout models: 4'460 µF max. 24 Vout models: 1'750 µF max. 28 Vout models: 1'280 µF max. 48 Vout models: 430 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Start-up Time 25 ms typ. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 110 - 140% of Iout max. Output Specifications TEP 100 Series, 100 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 5

Overvoltage Protection 115 - 130% of Vout nom. Transient Response - Response Time 200 µs typ. / 250 µs max. (25% Load Step) Safety Standards - IT / Multimedia Equipment EN 60950-1 EN 62368-1 IEC 60950-1 IEC 62368-1 UL 60950-1 UL 62368-1 - Certification Documents www.tracopower.com/overview/tep100 Safety Specifications EMI Emissions - Conducted Emissions EN 55011 class B (with external filter) EN 55032 class B (with external filter) - Radiated Emissions EN 55011 class B (with external filter) EN 55032 class B (with external filter) External filter proposal: www.tracopower.com/overview/tep100 EMS Immunity EN 55024 (IT Equipment) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A Ext. input component: 2 x KY 220 µF - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A 1 s: EN 61000-4-8, 1000 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +75°C - Case Temperature +105°C max. - Storage Temperature –55°C to +125°C Power Derating - High Temperature Depending on model Depending on model (with Heat Sink) See application note: www.tracopower.com/overview/tep100 Over Temperature Protection Switch Off - Protection Mode 115°C typ. (Automatic recovery at 105°C typ.) - Measurement Point See application note: www.tracopower.com/overview/tep100 Cooling System Natural convection (20 LFM) Sense Function 10% max. of Vout nom. Remote Control - Voltage Controlled Remote On: 3.0 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin - Off Idle Input Current 3 mA typ. - Remote Pin Input Current -0.5 to 1.0 mA (Optional models with inverse logic available) Altitude During Operation 2'000 m max. (for basic insulation) 5'000 m max. (for functional insulation) Switching Frequency 270 - 330 kHz (PWM) 300 kHz typ. (PWM) Insulation System Basic Insulation Isolation Test Voltage - Input to Output, 60 s 3'000 VDC - Input to Case, 60 s 1'600 VDC - Output to Case, 60 s 1'600 VDC Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. General Specifications TEP 100 Series, 100 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 5

Isolation Capacitance - Input to Output, 100 kHz, 1 V 2'500 pF max. Reliability - Calculated MTBF 331'000 h (MIL-HDBK-217F, ground benign) Washing Process Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf Environment - Vibration MIL-STD-810F - Thermal Shock MIL-STD-810F Housing Material Metal Base Material Non-conductive FR4 (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) Pin Material Copper Pin Foundation Plating Nickel (2 - 3 µm) Pin Surface Plating Tin (3 - 5 µm), matte Housing Type Metal Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Footprint Type Half-Brick Weight 97 g Thermal Impedance - Case to Ambient 6.7 K/W typ. 4.7 K/W typ. (with Heat Sink) Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/tep100 TEP 100 Series, 100 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 4 / 5

TEP 100 Series, 100 Watt 5.1 12.7 0.6 61.0 50.80 7.62 17.78 25.4 48.26 4.8 57.9 (2.28) 1 2 34 5 6 8 9 7 Screw 1 4-M3 through hole (1.9) (0.19) (2.0) (2.4) (0.7) (0.5) (1.0) BOTTOM VIEW (0.3) (0.023) (0.2) Dimensions in mm (inch) Tolerances x.x±0.5 (x.xx±0.02) Tolerances x.xx±0.25 (x.xxx±0.01) Pin pich tolerances ±0.25 (±0.01) Pin dimension tolerances ±0.1 (±0.004) The Screw 1 locked torque: max. 5.0 kgfcm / 0.49 Nm Pinout Pin Single Pin Diameter 1 in (GND) 1.0 mm (0.04 inch) 2 Case 1.0 mm (0.04 inch) 3 Remote On/Off 1.0 mm (0.04 inch) 4 +Vin (Vcc) 1.0 mm (0.04 inch) 5 out 2.0 mm (0.08 inch) 6 ense 1.0 mm (0.04 inch) 7 Trim 1.0 mm (0.04 inch) 8 +Sense 1.0 mm (0.04 inch) 9 +Vout 2.0 mm (0.08 inch) © Copyright 2022 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 5 / 5