TEN40WIRH TRACOPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

DC/DC Railway Converter TEN 40WIRH Series, 40 Watt

  • Fully encapsulated 2”x1” package
  • 3000 VAC I/O isolation (reinforced)
  • 4:1 input voltage range: 36 – 160 VDC
  • EN 50155 and EN 61373 certified
  • Internal class A EMI filter
  • -40°C up to +70°C operating temperature
  • EN 45545-2 fire behavior
  • Remote on/off function
  • Undervoltage lockout (UVLO), short-circuit protection (SCP), overtemperature protection (OTP), and overvoltage protection (OVP)
  • 3-year product warranty IEC 62368-1UL 62368-1 The TEN 40WIRH is a series of 40 watt railway-certified DC/DC converters with reinforced I/O isolation for highest reliability in harsh environments. The proven and certified design guarantees highest resistance against thermal shocks, moisture, mechanical shocks, and vibration. The TEN 40WIRH comes with ad- ditional EN 62368-1 safety approvals for IT equipment and EN 45545-2 certifi- cation for fire behavior. Thanks to its favorable operating temperature range of -40°C up to +70°C (depending on the model), the TEN 40WIRH presents a first choice for demanding applications. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TEN 40-11011WIRH 36 - 160 VDC (110 VDC nom.)

5.1 VDC 8'000 mA 88 %

TEN 40-11012WIRH 12 VDC 3'330 mA 89 % TEN 40-11013WIRH 15 VDC 2'666 mA 90 % TEN 40-11015WIRH 24 VDC 1'666 mA 89 % TEN 40-11022WIRH +12 VDC 1.666 mA –12 VDC 1.666 mA 88 % TEN 40-11023WIRH +15 VDC 1.333 mA –15 VDC 1.333 mA 89 % Options on demand (backorder with MOQ non stocking item) - Optional models with inverse remote on/off function (passiv = off) www.tracopower.com November 30, 2022 Page 1 / 5

Input Current - At no load 10 mA typ. Surge Voltage 200 VDC max. (1 s max.) Input Inrush Current 55 A typ. Under Voltage Lockout 32 VDC min. / 34 VDC typ. / 35.8 VDC max. Recommended Input Fuse 3'150 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Input Specifications Output Voltage Adjustment ±10% (5.1, 12 Vout single models) -10% to +20% (15, 24 Vout single models) (By external trim resistor) See application note: www.tracopower.com/overview/ten40wirh Output power must not exceed rated power! Voltage Set Accuracy ±1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.2% max. dual output models: 0.5% max. - Load Variation (0 - 100%) single output models: 0.5% max. dual output models: 1% max. (Output 1) 1% max. (Output 2) - Voltage Balance (symmetrical load) dual output models: 2% max. - Cross Regulation (25% / 100% asym. load) dual output models: 5% max. Ripple and Noise (20 MHz Bandwidth) - single output 5.1 Vout models: 75 mVp-p typ. (w/ 1 µF, 50 V, X7R) 12 Vout models: 100 mVp-p typ. (w/ 1 µF, 50 V, X7R) 15 Vout models: 100 mVp-p typ. (w/ 1 µF, 50 V, X7R) 24 Vout models: 150 mVp-p typ. (w/ 1 µF, 50 V, X7R) - dual output 12 / -12 Vout models: 100 / 100 mVp-p typ. (w/ 1 µF, 50 V, X7R) 15 / -15 Vout models: 100 / 100 mVp-p typ. (w/ 1 µF, 50 V, X7R) Capacitive Load - single output 5.1 Vout models: 9'600 µF max. 12 Vout models: 1'667 µF max. 15 Vout models: 1'066 µF max. 24 Vout models: 417 µF max. - dual output 12 / -12 Vout models: 833 / 833 µF max. 15 / -15 Vout models: 533 / 533 µF max. Minimum Load Not required Temperature Coefficient ±0.02 %/K max. Start-up Time 30 ms typ. / 60 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 150% typ. of Iout max. Overvoltage Protection 126% typ. of Vout nom. (depending on model) 6.2 VDC typ. (5.1 Vout model) 15 VDC typ. (12 Vout model) 20 VDC typ. (15 Vout model) 30 VDC typ. (24 Vout model) (by Zener diode) Transient Response - Peak Variation 450 mV typ. / 650 mV max. (75% to 100% Load Step) - Response Time 250 µs typ. / 300 µs max. (75% to 100% Load Step) Output Specifications TEN 40WIRH Series, 40 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 5

Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Railway Applications EN 50155 - Certification Documents www.tracopower.com/overview/ten40wirh Pollution Degree PD 2 Over Voltage Category OVC II Safety Specifications EMI Emissions EN 50121-3-2 (EMC for Rolling Stock) - Conducted Emissions EN 55032 class A (internal filter) EN 55032 class B (with external filter) - Radiated Emissions EN 55032 class A (internal filter) EN 55032 class B (with external filter) External filter proposal: www.tracopower.com/overview/ten40wirh EMS Immunity EN 50155 (Railway Applications) EN 50121-3-2 (EMC for Rolling Stock) EN 55024 (IT Equipment) - Electrostatic Discharge Air: EN 61000-4-2, ±8 kV, perf. criteria A Contact: EN 61000-4-2, ±6 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 20 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A Ext. input component: 2x 220 μF, 200 V, KXJ // SMDJ170A - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A 1 s: EN 61000-4-8, 1000 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +70°C - Case Temperature +105°C max. - Storage Temperature –55°C to +125°C Power Derating - High Temperature Depending on model See application note: www.tracopower.com/overview/ten40wirh Over Temperature Protection Switch Off - Protection Mode 115°C min. (Automatic recovery) - Measurement Point Case Cooling System Natural convection (20 LFM) Remote Control - Voltage Controlled Remote On: 3.0 to 12 VDC or open circuit Off: 0 to 1.2 VDC or short circuit Refers to 'Remote' and '-Vin' Pin - Off Idle Input Current 3 mA typ. / 3.5 mA max. (Optional models with inverse logic (passiv = off) available) Altitude During Operation 5'000 m max. Switching Frequency 250 - 310 kHz (PWM) 275 kHz typ. (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 161 VAC Isolation Test Voltage - Input to Output, 60 s 3'000 VAC - Input to Case, 60 s 3'000 VAC - Output to Case, 60 s 2'000 VAC Creepage - Input to Output 4.5 mm min. Clearance - Input to Output 4.5 mm min. Isolation Resistance - Input to Output, 500 VDC 1'000 MΩ min. General Specifications TEN 40WIRH Series, 40 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 5

Isolation Capacitance - Input to Output, 100 kHz, 1 V 650 pF typ. 1'000 pF max. Reliability - Calculated MTBF 1'253'000 h (MIL-HDBK-217F, ground benign) Washing Process Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf Environment - Vibration MIL-STD-810F EN 61373 - Mechanical Shock MIL-STD-810F EN 61373 - Thermal Shock MIL-STD-810F EN 50155 Housing Material Non-conductive Plastic (UL 94 V-0 rated) Base Material Non-conductive Plastic (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) Pin Material Tinned Copper Pin Foundation Plating Nickel (2 - 3 µm) Pin Surface Plating Tin (3 - 5 µm), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Footprint Type 2" x 1" Soldering Profile Wave Soldering 260°C / 6 s max. Weight 32 g Thermal Impedance - Case to Ambient 11.3 K/W typ. Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) - Flammability (EN 45545-2) www.tracopower.com/info/en45545-declaration.pdf Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/ten40wirh TEN 40WIRH Series, 40 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 4 / 5

TEN 40WIRH Series, 40 Watt 25.4 (1.00) 50.8 (2.00) 45.72 (1.80) 17.78 (0.70) 2.54 (0.10) 15.24 (0.60) 5.1 (0.20) 10.2 (0.40) 5.6 (0.22) 5.08 (0.20) 6 5 4 3 2 1 7.62 (0.30) All dimension in mm (inch) Tolerance: X.X ±0.5 (X.XX ±0.02) X.XX ±0.25 (X.XXX ±0.010) Pin dimension tolerance ±0.10 (±0.004) Bottom View Ø 1.0 (0.04) Pinout Pin Single Dual 1 +Vin 2 in

3 Remote On/Off

6 Trim out

© Copyright 2022 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 5 / 5