Features
◆ Wide 2:1 input range ◆ High power density ◆ Operating temperature range –40°C to +85°C ◆ Indefinite short circuit protection ◆ I/O isolation 1500 VDC ◆ Input filter to meet EN 55022, Class A and FCC, level A without external components ◆ Industry standard pinout ◆ Shielded metal case with insulated baseplate ◆ High reliability, MTBF >1 Mio. h ◆ 3-year product warranty DC/DC Converters TEN 10 Series, 10 Watt The TEN 10 series is a family of high performance 10W DC/DC converters in a compact 2” x 1” low profile package with industry standard footprint. A high effici- ency allows a wide operating temperature range of –40°C to +85°C. A built-in EMI filter is built in to meet EN 55022, class A without any external components. Further standard features include over voltage protection and short-circuit protec - tion. Typical applications for these converters are battery operated equipment, in - strumentation, distributed power architectures in communication and industrial elec- tronics, everywhere where isolated, tightly regulated voltages are required. Order code Input voltage range Output voltage Output current max. Efficiency typ. TEN 10-1210 3.3 VDC 2’400 mA 72 % TEN 10-1211 5 VDC 2‘000 mA 77 % TEN 10-1212 12 VDC 830 mA 80 % TEN 10-1213 9 – 18 VDC 15 VDC 670 mA 80 % TEN 10-1215 (12 VDC nominal) 24 VDC 415 mA 81 % TEN 10-1221 ±5 VDC ±1‘000 mA 78 % TEN 10-1222 ±12 VDC ±415 mA 81 % TEN 10-1223 ±15 VDC ±330 mA 80 % TEN 10-2410 3.3 VDC 2’400 mA 76 % TEN 10-2411 5 VDC 2‘000 mA 78 % TEN 10-2412 12 VDC 830 mA 82 % TEN 10-2413 18 – 36 VDC 15 VDC 670 mA 82 % TEN 10-2415 (24 VDC nominal) 24 VDC 415 mA 83 % TEN 10-2421 ±5 VDC ±1‘000 mA 80 % TEN 10-2422 ±12 VDC ±415 mA 82 % TEN 10-2423 ±15 VDC ±330 mA 82 % TEN 10-4810 3.3 VDC 2‘400 mA 76 % TEN 10-4811 5 VDC 2‘000 mA 80 % TEN 10-4812 12 VDC 830 mA 82 % TEN 10-4813 36 – 75 VDC 15 VDC 670 mA 83 % TEN 10-4815 (48 VDC nomial) 24 VDC 415 mA 83 % TEN 10-4821 ±5 VDC ±1‘000 mA 81 % TEN 10-4822 ±12 VDC ±415 mA 83 % TEN 10-4823 ±15 VDC ±330 mA 83 % Models UL 60950-1 not recommended for new design in
http://www.tracopower.com Page 2 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. Input Specifications Input current at no load 12 Vin models: 30 mA typ. 24 Vin models: 20 mA typ. 48 Vin models: 10 mA typ. Input current at full load 12 Vin; 3.3 VDC models: 915 mA typ. 12 Vin; 5 & ±5 VDC models: 1080 mA typ. 12 Vin; other output models: 1045 mA typ. 24 Vin; 3.3 VDC models: 435 mA typ. 24 Vin; 5 & ±5 VDC models: 530 mA typ. 24 Vin; other output models: 510 mA typ. 48 Vin; 3.3 VDC models: 215 mA typ. 48 Vin; 5 & ±5 VDC models: 260 mA typ. 48 Vin; other output models: 250 mA typ. Start-up voltage / 12 Vin models: 8.5 VDC / 8 VDC under voltage shut down 24 Vin models: 16.5 VDC / 16 VDC 48 Vin models: 32.5 VDC / 32 VDC Surge voltage 12 Vin models: 25 V max. (1 sec. max.) 24 Vin models: 50 V max. 48 Vin models: 100 V max. Reserve voltage protection 1.0 A max. Conducted noise (input) EN 55022 level A, FCC part 15, level A Output Specifications Voltage set accuracy ±1 % Regulation – Input variation Vin min. to Vin max. 0.3 % max. – Load variation 10 % – 90 % single output models: 0.5 % max. dual output models: 1 % max. (balanced load) dual output models: 3 % max. (unbalanced load) Ripple and noise (20 MHz Bandwidth) single output models: 50 mVpk-pk max. dual output models: 75 mVpk-pk max. Temperature coefficient ±0.02 %/K Output current limitation >1 10 % of lout max., constant current Short circuit protection continuous (automatic recovery) Capacitive load single output models: 2200 µF max. dual output models: 470 µF max. General Specifications Temperature ranges – Operating –40°C to +85°C – Case temperature +100°C max. – Storage –40°C to +125°C Derating (convection cooling) 3.3 %/K above 70°C Humidity (non condensing) 95 % rel H max. Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) >1 Mio h Isolation Test Voltage (Input/Output, 60s) 1‘500 VDC Insulation System Functional Isolation Capacitance (Input/Output) 150 pF typ. Isolation Resistance (Input/Output) >1 G Ohm Switching Frequency single output models: 500 kHz typ. (pulse width modulation) dual output models: 300 kHz typ. (pulse width modulation) DC/DC Converters TEN 10 Series 10 Watt
http://www.tracopower.com Page 3 of 4 All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated. General Specifications EMC immunity – Electrostatic discharge ESD EN 61000-4-2 8 kV / 6 kV, criteria B – RF field susceptibility EN 61000-4-3 10 V/m, criteria A – Electrical fast transient / burst immunity input EN 61000-4-4 ±2 kV, criteria B – Surge immunity EN 61000-4-5 ±1 kV, criteria B – Immunity to conducted RF disturbances EN 61000-4-6 10 Vrms, criteria A Thermal shock, mechanical shock & vibration EN 61373, MIL-STD-810F Safety standards UL 60950-1, IEC/EN 60950-1 Safety approvals – UL/cUL www.ul.com -> certifications -> File e188913 Environmental compliance – Reach www.tracopower.com/overview/ten10 – RoHS directive 201 1/65/EU Physical Specifications Casing material Steel chrome-nickel plated Baseplate material Epoxy Potting material Epoxy (UL 94 V-0 rated) Weight 32 g (1.13 oz) Soldering temperature max. 265°C / 10 sec.Outline Dimensions Thermal Impedance 7 .0 K/W typ. 3.5 K/W typ. (with Heatsink) DC/DC Converters TEN 10 Series 10 Watt Outline Dimensions Pin Single Dual 1 +Vin (Vcc) +Vin (Vcc) 2 –Vin (GND) –Vin (GND) 3 +Vout +Vout
4 No pin Common
5 –Vout –Vout Pin-Out Dimensions in [mm], () = Inch Pin diameter: 1.0 ±0.05 (0.039 ±0.0019) Pin pitch tolerances: ±0.25 (±0.01) Casing tolerances: ±0.5 (±0.02) 5.08 10.16 25.4 10.2 6.0 50.8 15.2 20.32 Insulated baseplate (2.0) (0.8) (0.6) (0.2) (0.4) (0.4) (1.0) 2.5 (0.1) (0.4)(0.24) Bottom View 1 4 10.16 10.2 (0.4)
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com www .tracopower.com DC/DC Converters TEN 10 Series 10 Watt Rev. October 26, 2022 Note: Before attaching the heatsink, the product label on converter has to be removed for optimal performance. For volume orders we can supply the converters with heatsink already mounted. Please contact us for a relative quotation. Order code: TEN-HS4 (cont.: heat-sink, thermal pad, 2 clamps) Material: Aluminum Finish: Anodic treatment (black) Weight: 9 g (0.31oz) without converter 17.2 (0.68) max. Converter Heat-sink Thermal pad Clamp31.0 (1.22) max. 31.1 (1.22) Heat-sink TEN-HS4 (optional) Heat-Sink (Option)