STN-SF415-04-D2 ERAVANT | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
STN-SF415-04-D2 Rev. 1.0 www.sagemillimeter.com | 3043 Kashiwa Street, Torrance, CA 90505 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: sales@sagemillimeter.com Page | 1 SAGE Millimeter, Inc. V-Band Network Analyzer Extender Copyright © 2015 by SAGE Millimeter, Inc. Description: Model STN-SF415-04-D2 is a V-band scalar network analyzer extender that extends low frequency scalar network analyzers to 50 to 75 GHz. The extender offers a low cost means of producing V-band measurements while preserving the functionality and features of standard models. The extender is constructed with SAGE Millimeter’s high performance millimeterwave frequency extender (model STE-SF415-04-S1), direct reading attenuator (model STA-60-15-D1), directional coupler (model SWD-1040H-15-SB), and waveguide detectors (model STD-15SF-NI). Features: Full Waveguide Band Operation Moderate Dynamic Range Cost Effective Solution Applications: Test Lab Test Instrumentations Electrical Specifications: Parameter Minimum Typical Maximum Output Frequency Range 50.00 GHz 75.00 GHz Input Frequency Range 12.50 GHz 18.75 GHz Output Power +4 dBm Input Power +5 dBm +20 dBm Insertion Loss Dynamic Range 30 dB Return Loss Dynamic Range 20 dB DC Voltage +8 VDC +8 VDC +12 VDC DC Current 450 mA 750 mA Mechanical Specifications: Item Specification RF Input SMA (F) RF Output WR-15 Waveguide with UG-385/U Flange Detector Output SMA (F) Extender Bias Banana Jack Finish Black Anodized and Gold Plated Weight 6.8 lb Outline TN-DV2
STN-SF415-04-D2 Rev. 1.0 www.sagemillimeter.com | 3043 Kashiwa Street, Torrance, CA 90505 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: sales@sagemillimeter.com Page | 2 SAGE Millimeter, Inc. V-Band Network Analyzer Extender Copyright © 2015 by SAGE Millimeter, Inc. Mechanical Outline: (Unless otherwise specified, all dimensions are in inches) Note: All data are presented using a limited sample lot. Actual data may vary unit to unit. All testing was performed under +25˚C case temperature. SAGE Millimeter, Inc. reserves the right to change the information presented without notice. Caution: Exceeding absolute maximum ratings of the device will damage the device. torque wrench, model SCH-08008-S1, is highly recommended. Any foreign objects in the waveguide will cause performance degradation or damage the device. -20 -15 -10 50 55 60 65 70 75 Output Power (dBm) Frequency (GHz) Typical Performance vs. Frequency Pin: +0 dBm, Bias: +8 VDC/450 mA