STE-KF612-12-S1-C ERAVANT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 3

Technical content

www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2025 by Eravant Rev 1.1 E-Band ACCESS X6 Full Band Frequency Extender, 55 to 95 GHz, +12 dBm Pout STE-KF612-12-S1-C is an E-band compact X6 frequency extender. The extender delivers frequency of 55 to 95 GHz with a typical output power of +12 dBm for an input signal within 9.17 to 15.83 GHz range. The extender has a typical harmonic suppression of -20 dBc. The compact design offers a practical solution for microwave frequency extention of signal generators, such as Eravant synthesizer STL-SG-022203-S1.The input port configuration is a female K connector and the output is a WR- 12 waveguide with a UG-387/U anti-cocking flange. Calibration data stored in the device memory can be directly accessed via USB-C cable. An AC to DC Power adapter and a Proxi-Flange™ Contactless Flange (STQ-WG-12010-FB-CF) is also included. Electrical Specifications: Mechanical Specifications: Parameter Minimum Typical Maximum Output Frequency 55 GHz 95 GHz Input Frequency 9.17 GHz 15.83 GHz Output Power +12 dBm Input Power -3 dBm +0 dBm +5 dBm Return Loss 10 dB Harmonic Suppression -20 dBc Multiplication Factor 6 Power Supply 100 VAC 240 VAC Specification Temperature +25 °C Operating Temperature 0 °C +50 °C Item Specification Output Port WR-12 Waveguide with UG-387/U Anti-Cocking Flange Input Port K(F) DC Bias Port 2.5 mm DC Jack (AC-to-DC power converter included) Memory Port USB-C Socket DC Bias Switch On-Off Latching Switch with Indicator Light Enclosure Material Black Anodized Aluminum Weight 1.5 lbs. Outline TE-WG-A-C-2 ECCN 3A001.b.7

FEATURES

  • 55-95 GHz Extended Coverage
  • Low Harmonic Emission
  • Built-in Memory Cal Data
  • Compact Size
  • Forced Air Cooling
  • Input Voltage: 100 to 240 VAC

APPLICATIONS

  • Signal Generator Frequency Extension
  • Antenna Range RECOMMENDED PAIRINGS
  • Waveguide Quick Connects
  • Cable: SCW-SMSM040-F1-A
  • Coax Adapters
  • Waveguide to Coax Adapters RECOMMENDED RESOURCES
  • Contactless WG Flange & mmW Sub-THz Test Setup Applications
  • Proxi-Flange: Conference Papers

www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2025 by Eravant Rev 1.1 Components Included: Note: Connecting cables are not included. Eravant coaxial cable, model SCW-SMSM040-F1-A is highly recommended. Mechanical Outline: (Unless otherwise specified, all dimensions are in inches [millimeters]) Item Eravant Model Number Quantity Proxi-Flange™ Contactless Flange, 1.0” Long STQ-WG-12010-FB-CF 1 Waveguide Screws, 3/32 Hex Head SWH-332-SS-10 1 (10 Screws Total) Waveguide Screwdriver, 3/32 Hex Head SWH-332-DS 1 Waveguide Screw, 5/64 Hex Head SWH-564-SS-10 1 (10 Screws Total) Waveguide Screwdriver, 5/64 Hex Head SWH-564-DS 1 USB-C Cable PES-AEUSUS164-1 1 Coax Connector Torque Wrench SCH-08008-S1 1 AC-to-DC Power Adapter PEP-PJ2555-1 1

www.eravant.com | 424-757-0168 | support@eravant.com Copyright © 2025 by Eravant Rev 1.1 NOTE:

  • Performance plots shown above represent a sample lot performance. Actual data may show some unit-to-unit variation.
  • Eravant offers calibration services. It is recommended that calibration be performed every 12 months to ensure equipment compliance.
  • Connecting cables are not included. The use of Eravant coaxial cables (model SCW-SMSM040-F1-A) is highly recommended.
  • Coaxial adapters may be necessary, depending on the connector type of the signal source. Appropriate Eravant adapters are recommended.
  • To test a DUT with a coaxial interface, use suitable Eravant waveguide-to-coaxial adapters.
  • Operation outside the specified frequency range may result in degraded performance.
  • Eravant reserves the right to modify product information without prior notice. CAUTION:
  • Any foreign objects in the waveguide may cause performance degradation and damage the unit.
  • Exceeding the absolute maximum ratings of the device may cause permanent damage to the extenders. (0.90 ± 0.02 Nm). Torque wrench model SCH-08008-S1 is highly recommended.