SSR-1010N10-SE1 Advanced Rev 1.1 www.eravant.com | 501 Amapola Ave, Torrance, CA 90501 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: support@eravant.com WR-10 Receiver, 75 to 110 GHz, 10 dB Conversion Loss Page | 1 SAGE Millimeter, Inc. Copyright © 2023 by Eravant Description: Model SSR-1010N10-SE1 is a full WR-10 integrated receiver module. The receiver has a typical conversion loss of 10 dB with a typical Noise Figure of 10 dB in the frequency range of 75 to 110 GHz. The required LO power is +3 dBm between frequencies of 12.5 and 18.33 GHz. The RF receive port is WR-10 Waveguide with UG-387/U-M Anti-Cocking Flange while the LO and IF port is female SMA connectors. Other port configurations, are also available under different model numbers. Features:
- Built in x6 LO Multiplier
- Fully Integrated Module Applications:
- Communication Systems Electrical Specifications: Parameter Minimum Typical Maximum RF Input Frequency 75 GHz 110 GHz RF Input Power +10 dBm IF Output Frequency DC 1 GHz 12 GHz LO Frequency 12.5 GHz 18.33 GHz LO Input Power +3 dBm +20 dBm Conversion Loss 10 dB Noise Figure 10 dB Input P1dB 0 dBm Bias Voltage +6 VDC +8 VDC +15 VDC Bias Current 330 mA Specification Temperature +25 °C Operating Temperature 0 °C +50 °C Mechanical Specifications: Item Specification RF Port WR-10 Waveguide with UG-387/U-M Anti-Cocking Flange LO Port SMA (F) IF Port SMA (F) Bias Solder Pin Case Material Aluminum Finish Gold Plated Weight 2.0 Oz Outline SR-SW-A-5
SSR-1010N10-SE1 Advanced Rev 1.1 www.eravant.com | 501 Amapola Ave, Torrance, CA 90501 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: support@eravant.com WR-10 Receiver, 75 to 110 GHz, 10 dB Conversion Loss Page | 2 SAGE Millimeter, Inc. Copyright © 2023 by Eravant Mechanical Outline: (Unless otherwise specified, all dimensions are in inches [millimeters]) -20 -15 -10 75 80 85 90 95 100 105 110 Conversion Loss (dB) Frequency (GHz) Conversion Loss vs. Frequency RF: -20 dBm; IF: 1 GHz
SSR-1010N10-SE1 Advanced Rev 1.1 www.eravant.com | 501 Amapola Ave, Torrance, CA 90501 Phone: 424-757-0168 | Fax: 424-757-0188 | Email: support@eravant.com WR-10 Receiver, 75 to 110 GHz, 10 dB Conversion Loss Page | 3 SAGE Millimeter, Inc. Copyright © 2023 by Eravant Note:
- Eravant reserves the right to change the information presented without notice.
- Other mechanical configurations are available under different model numbers. Caution:
- Exceeding absolute maximum ratings shown will damage the device.
- The device is static sensitive. Always follow ESD rules when working with the device.
- The case temperature of the device shall never exceed +50 ˚C. Use proper heatsink or fan if necessary. wrench, model SCH-08008-S1, is highly recommended.