EXTERNAL AC/DC POWER SUPPLIES 40 W External AC/DC Power Supplies 1

2 YEAR WARRANTY

  • 4.21 x 1.77 x 0.98 inch enclosure
  • 40 W external power supply
  • Molded UL94V-0 plastic enclosure
  • Stand alone ‘listed’ equipment
  • Overvoltage and short circuit protection
  • EN55022, EN55011, FCC conducted and radiated emissions level B
  • UL, CSA and VDE safety approvals
  • Available RoHS compliant The SSL40 series is a 40 W universal input ac-dc external power supply in a 4.21 x 1.77 x 0.98 inch plastic enclosure. The SSL40 is a low cost series with six single output models in a very small package providing a pre-approved external power solution for a host of worldwide low power portable and desktop applications. The SSL40 provides 40 W of output power with free air convection cooling. Standard features include universal input, overvoltage, short circuit protection and EN55022 conducted emissions level B. The series, with full international safety approval and the CE mark, provides pre-approved SELV outputs without the need for further safety approval or mechanical integration into the application system. The SSL40 series is designed for use in low power, portable and desktop data networking, computer and industrial applications requiring low cost external power adapters in a small package. All specifications are typical at nominal input, full load at 25 °C unless otherwise stated GENERAL SPECIFICATIONS Hold-up time 110 Vac @ 40 W 5 ms

230 Vac @ 40 W 45 ms

Efficiency 110 Vac @ 40 W 83% typical Isolation voltage Input/output 3000 Vac Switching frequency Fixed 100 kHz ±10 kHz Approvals and Safety VDE0805, EN60950 standards IEC950, UL1950 CSA C22.2 No. 950 Case material General Electric Lexan, black Flammability rated UL94V-0 Weight 200 g (7.06 oz) MTBF MIL-HDBK-217F 150,000 hours min. ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating temperature 0 °C to +40 °C full load, no derating Non-operating –40 °C to +85 °C 0 °C to +40 °C ambient, Full load convection cooled Peak (See Note 1) Relative humidity Non-condensing 5% to 95% RH Altitude Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 6) 5-500 Hz 2.4 G rms Shock per MIL-STD-810E 516.4 Part IV OUTPUT SPECIFICATIONS Line regulation Single output ±0.5% Total regulation (See Note 3) ±2.0% Overshoot/undershoot At turn on 1.0% Transient response Main output ±5.0% max. dev., 50% to 100% 1ms recovery load step to 1.0% Temperature coefficient ±0.02%/°C, max. Overvoltage protection See table Output power limit 135% to 175% of max. output power Short circuit protection Continuous with auto-restart INPUT SPECIFICATIONS Input voltage range Universal input 90-264 Vac Input frequency range 47-440 Hz Input current 90 Vac 1.00 Arms max. 220 Vac 0.52 Arms max. EMC CHARACTERISTICS Radiated emissions EN55022/11, FCC part 15 Level B Conducted emissions EN55022/11, FCC part 15 Level B SPECIFICATIONS International Safety Standard Approvals VDE0805/EN60950/IEC950 License No. 104723G UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062 geprüfte Sicherhelt File Name: ssl40.pdf Rev (02): 07 Nov 2005

Datasheet © Artesyn Technologies® 2005 The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. For the most current data and application support visit www.artesyn.com/powergroup/products.htm Notes

1 Peak output current lasting less than 60 seconds with duty cycle less than

5.0%. During peak loading, output voltage may exceed total regulation limits. 2 20 MHz bandwidth, peak to peak, measured using a 12 inch twisted pair terminated with a 47 µF electrolytic capacitor.

3 Total regulation is defined as the static output regulation at 25 °C, including

initial tolerance, line voltage within stated limits, load currents within stated limits, and output voltages adjusted to their factory settings.

4 To help maintain the power supply safety approvals, the IEC320/C7 input

connector cable must be rated minimum 3.0 A and approved by an applicable safety agency for the intended country of use. National and international variations on mains plugs, adapters and customer preference to lead length prevents Artesyn from supplying an IEC320/C7 (or compatible) input connector cable. The IEC320/C7 input (or compatible) connector cable can be sourced locally, e.g. Newark, Qual Electronics, Radio Shack, etc. or other non affiliated distributors. SSL40 Series Single output EXTERNAL AC/DC POWER SUPPLIES 40 W External AC/DC Power Supplies 2 www.artesyn.com OUTPUT OUTPUT CURRENTS RIPPLE (2) OVP TOTAL MODEL VOLTAGE MIN MAX PEAK (1) THRESHOLD (5) REGULATION (3) NUMBER (8,9) 1.77 (45.00) 0.83 (21.00) 0.47 (12.00)0.55 (14.00) 2.09 (53.00) 4.21 (107.00) 36.00 ± 0.79 (914.00 ± 20) 20) 0.98 (25.00) ALL DIMENSIONS IN INCHES (mm) 0.098 (2.500) PHONE JACK PIN CONNECTIONS 2.5 MM JACK PLUG Inner V A SWITCHCRAFT Power Outer Return Jack, P/N 712A or equiv. File Name: ssl40.pdf Rev (02): 07 Nov 2005 Notes 5 Output voltage protected by Zener diode. 6 Three orthogonal axes random vibration, 10 minute test for each axis. 7 IEC320/C8 type input connector. 8 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request, please contact your local sales representative for details. 9 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative.