Technical content
The SMT40C Series is a new high density open frame non-isolated converter for space-sensitive applications. Each model has a wide input range of 10.2 Vdc to 13.8 Vdc and offers a wide 0.9 Vdc to 5.0 Vdc output voltage range with a 40 A load. An external resistor adjusts the output voltage from its pre-set value of 0.9 V to any value up to 5 V. Typical efficiencies are 92% at full load conditions. The SMT40C series offers remote ON/OFF and overcurrent protection as standard. With full international safety approval including EN60950 and UL/cUL60950, the SMT40C reduces compliance costs and time to market. Embedded Power for Business-Critical Continuity SMT40C Series
12 Vin single output
- 40 A current rating
- Input voltage range: 10.2 Vdc - 13.8 Vdc
- Output voltage range: 0.9 Vdc - 5.0 Vdc
- Industry leading value
- Cost optimized design
- Excellent transient response
- Output voltage adjustability
- Pathway for future upgrades
- Supports silicon voltage migration
- Resulting in reduced design-in and qualification time
- Designed in reliability: MTBF of >4 million hours per Telcordia SR-332
- Current share
- Available RoHS compliant
- 2 year warranty Total Power: 200W Input Voltage: 10.2-13.8 Vdc # of Outputs: Single Safety UL/cUL : UL/cUL CAN/CSA 22.2 No. 60950 UL 60950 File No. E139421 TÜV Product Service (EN60950:2000) Certificate No. B 04 08 19870 228 CB report and certificate to IEC60950-US/6415C/UL Rev.06.25.07 smt40c 1 of 4
Rev.06.25.07 smt40c 2 of 4 Embedded Power for Business-Critical Continuity All specifications are typical at nominal input Vin = 12V, full load at 25 °C unless otherwise stated. Specifications OUTPUT SPECIFICATIONS Voltage adjustability (See Note 5) 0.9-5.0 Vdc Output setpoint accuracy 1.0% trim resistors ±3.0% Line regulation Low line to high line ±0.2% max. Load regulation Full load to min. load ±1.5% max. Min/max load 0 A/40 A Overshoot At turn-on 1.0% max. Undershoot At turn-off 100 mV max. Ripple and noise (See Note 1) 50 mV pk-pk
5 Hz to 20 MHz 15 mV rms
Transient response 75 mV max. deviation (See Note 2) 50 μs recovery to within regulation band Current share Full load ±10% INPUT SPECIFICATIONS Input voltage range 10.2-13.8 Vdc Input current Minimum load 290 mA Remote OFF 30 mA Input current (max.) 22 A max @ lo max and Vin = 10.2 V Input reflected ripple (See Note 4) 150 mA pk-pk Remote ON/OFF Logic compatibility Positive logic ON >2.4 Vdc OFF <0.8 Vdc Start-up time Power up <30 ms (See Note 8) Remote ON/OFF <30 ms Turn ON threshold 9.0 Vdc typ. Turn OFF threshold 7.6 Vdc typ. GENERAL SPECIFICATIONS Efficiency 92% typ. Switching frequency Fixed 300 kHz typ. Approvals and (See Note 7) TÜV Product Services standards IEC60950, UL/cUL60950 Material flammability UL94V-0 Weight 28.3 g (1.0 oz) Coplanarity 150 μm MTBF Telcordia SR-332, 4,585,991 hours method II @ 40 ºC ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient, 0 °C to +80 °C (See Note 9) temperature Non-operating -40 °C to +125 °C PROTECTION Short-circuit Foldback, non-latching Over-temperature Hiccup, non-latching RECOMMENDED SYSTEM CAPACITANCE Input capacitance (See Note 10) 2 x 270 μF/20 mW ESR max. Output capacitance (See Note 10) 3 x 680 μF/10 mW ESR max.
Rev.06.25.07 smt40c 3 of 4 Embedded Power for Business-Critical Continuity All specifications are typical at nominal input, full load at 25 °C unless otherwise stated. Specifications Notes 1 Measured as per recommended set-up. 2 x Cin = 270 μF (20 mW ESR max, 3 x Cout = 680 μF (10 mW ESR max). 2 di/dt = 10 A/μs, Vin = Nom, Tc = 25 °C, load change = 0.50 lo max. to 0.75 lo 3 External input fusing is recommended. 4 Measured with external filter. See Application Note 170 for details. 5 Uses external resistor from trim pin to output ground. See Application Note 170 for details. 6 Signal line assumed <3 m in length.
7 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product. 8 Power-up is the time from application of dc input to Power Good enabled. Remote ON/OFF is from ON/OFF asserted high to power good enabled. 9 See Application Note 170 for operation above 50 °C. 10 See Application Note 170 for ripple current requirements. 11 These models have a wide trim output. The unit has an output of 0.9Vdc to 5 Vdc. An external resistor adjusts the output voltage.
12 For redundant current sharing applications that use ORing diodes to separate
the outputs, please add the suffix ‘-S’ to the part number, e.g. SMT40C- 12SADJ-SJ. Please refer to Application Note 170 for further details.
13 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details. 14 NOTICE: Some models do not support all options. Please contact your local Artesyn representative or use the on-line model number search tool at http://www.artesyn.com/powergroup/products.htm to find a suitable alternative. OUTPUT INPUT OVP OUTPUT OUTPUT OUTPUT EFFICIENCY REGULATION MODELPOWER VOLTAGE VOLTAGE (11) CURRENT CURRENT LINE LOAD NUMBER (13,14) (MAX.) (MIN.) (MAX.) SMT40C-12SADJ-SJ Part Number System with Options Rated Output Current 40 = 40Amps Number of Outputs SADJ = Single Adjustable Output Product Family SMT = Surface Mount Performance C = Cost Optimized Input Voltage 12 = 10.2 Vdc to 13.8 Vdc The ultra-wide output voltage trim range offers major advantages to users who select the SMT40C series. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 0.9 Vdc to 5.0 Vdc. When the SMT40C series converter leaves the factory the output has been adjusted to the default voltage of 0.9 V. Output Voltage Adjustment of the SMT40C Series Current Sharing (12) No Suffix = Non-isolated Suffix ‘-S’ = Isolated Packaging Options(13) J = Pb-free (RoHS 6/6 compliant)
Business-Critical Continuity Rev.06.25.07 smt40c 4 of 4 Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co. Emerson Network Power. The global leader in enabling business-critical continuity. EmersonNetworkPower. com AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services Americas
5810 Van Allen Way
Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com technicalsupport@powerconversion.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. All dimensions in inches (mm) All tolerance ±0.010in (±0.25mm) unless otherwise stated 2.280 (57.91) 1.450 (36.83) PCB REF 0.062 (1.57) 0.43 (10.8) 0.105 (2.67) 0.011 (0.27) Typ0.140 (3.56) 15 x 0.090 (2.29) 2.100 (53.34) 0.045 (1.13) 0.485 (12.33) 1.140 (28.96) PIN 1 PIN 16 PIN 17 PIN 18 1.345 (3417) 2 x SMT Pin Size (18 PL) PIN CONNECTIONS PIN NO. FUNCTION PIN NO. FUNCTION