SPX-2000 CYPRESS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
SUPREX® II Remote Unit Dip Switch Setting Switch #2 - On = Door Strike Relay does NOT follow LED status. Off = Door Strike Relay follows status of LED. Switch #6* - On = Bit mode (Noise filter off) for keypad applications. Off = Noise filter mode, standard reader applications (Default setting) SUPREX® II Central Unit Dip Switch Setting Switch #3 - On = Inverts idle on MagStripe version Off = Normal operation of MagStripe version Switch #4 - On = Inverts Aux 2 Relay Status Off = Normal operation *Not active on versions earlier than 2-1-2003 SUPREX® II Connection Diagram Part Numbers:
- SPX-2000 : Wiegand format (RS-485)
- SPX-2100 : MagStripe format (RS-485)
- SPX-2500 : Wiegand format (RS-232)
- SPX-2600 : MagStripe format (RS-232) Dip Switch SUPREX Remote Unit Cypress Computer Systems, Inc. • 1778 Imlay City Rd. • Lapeer, MI 48446-3206 TX(810)245-2300 • FX(810)245-2332 • www.cypresscom.com SUPREX Central Unit Dip Switch +8 to +24 Vdc @ 150 ma Ground +5 Vdc @ 100 ma Data 0 / Clock Data 1 / Data LED Normally Closed Normally Open Common Normally Closed Normally Open Common Door Strike Relay
125 Vac @ 1 Amp
+8 to +24 Vdc @ 150 ma Ground +5 Vdc @ 100 ma Data 0 / Clock Data 1 / Data LED Normally Closed Normally Open Common Normally Closed Normally Open Common Trouble / Output Relay 2 relay, short LED to Ground READER OUTPUT RELAYS ACCESS CONTROL PANEL OUTPUT RELAYS RS-232 Connector LED Off On Input 2 Input 1 +8 to +24 Vdc @ 150 ma Ground Program Resistor #2 Program Resistor #1 Aux Relay Control +8 to +24 Vdc @ 150 ma Ground RS-232 Connector LED Off On When wired and powered up corectly, LEDs on Remote and Centrol will blink 5 to 10 times per second. When there is a problem with communication between the Remote and Central, the LED on the Central will blink 2 times per second and the Remote LED will not light at all. Actual size of each circuit board is 4-1/2” x 2-5/8” CYPRESS INDUSTRY LEADERS DEPEND ON US ...FOR SOLUTIONS 1 2 3 4 5 6 7 8 Line - Line + Line - Line + RS-232 DB-9 Male 5 - Ground 3- Transmit 2 - Receive
Typical 2-Wire Communications Installation Remote Central Power Supply Power Supply 10,000 Ft Gnd Pwr Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446 TX(810)245-2300 FX(810)245-2332 www.cypresscom.com Gnd Pwr Line -
- The Controller's LED signal changes the state of the Door Strike relay.
- The Controller's Supervised Alarm Input monitors the state of the End-of-Line Device.
- If loss of power or communication occurs, the Supervised Trouble Input will activate.
- The Programming Resistor 1 is used to calibrate the Remote Unit's Alarm Input 1 Sensor. (Any End-of-Line value from 100 Ω to 20KΩ can be monitored by using the same value for the Programming Resistor.) Typical 4-Wire Communications Installation with Wiegand Reader Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446 TX(810)245-2300 FX(810)245-2332 www.cypresscom.com End of Line Device Gnd +5vDC Data 0 Data 1 LED Power Supply Door Strike Wiegand Reader Remote 10,000 Ft. Line+ Line- Pwr Gnd Programming Resistor Central 12vDC Gnd Data 0 Data 1 LED Supervised Trouble Input Supervised Alarm Input Weigand Controller
- The Controller's LED signal changes the state of the Door Strike relay.
- The Controller's Supervised Alarm Input monitors the state of the End-of-Line Device.
- If loss of power or communication occurs, the Supervised Trouble Input will activate.
- The Programming Resistor 1 is used to calibrate the Remote Unit's Alarm Input 1 Sensor. (Any End-of-Line value from 100 Ω to 20KΩ can be monitored by using the same value for the Programming Resistor.) Typical 4-Wire Communications Installation with MagStripe Reader SPX-2100 Series Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446 TX(810)245-2300 FX(810)245-2332 www.cypresscom.com End of Line Device Remote Line+ Line- Gnd Pwr Power Supply Programming Resistor Central Door Strike Gnd +5vDC Clock Data LED MagStripe Reader 10,000 Ft. 12vDC Gnd Clock Data LED Supervised Trouble Input Supervised Alarm Input MagStripe Controller
SUPERVISED Status Monitoring Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446 TX(810)245-2300 FX(810)245-2332 www.cypresscom.com End of Line Device Remote Programming Resistor Central Supervised Alarm Input Programming Resistor End of Line Device Central Remote Supervised Alarm Input
(ie: Request-To-Exit, Door 211128 GND LED Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446 TX(810)245-2300 FX(810)245-2332 www.cypresscom.com SW1 SW2 Remote Central Sending Unsupervised Status from Remote to C Sending Unsupervised Status from Central to Rem Normally Op Contacts wil status of sw SW2 SW1 Normally Open Contacts will follow status of switch SW2 SW1 Remote Central SW2 SW1 Switches or Relay Contacts UN-SUPERVISED Status Monitoring